G200EI Series High Isolation, 2W Compact MiniDIP DC/DC Converters Electrical Specifications Specifications typical @ +25°C, nominal input voltage & rated output current, unless otherwise noted. Specifications subject to change without notice. Key Features: Input • 2W Output Power • Compact Mini-DIP Case • EN60950 Approved • Single & Dual Outputs • 3,000 VDC Isolation • >3.5 MHour MTBF • 24 Standard Models • LOW COST Parameter Conditions Min. Typ. 5 VDC Input 4.5 5.0 12 VDC Input 10.8 12.0 24 VDC Input 21.6 24.0 Internal Capacitor Input Voltage Range Input Filter Max. 5.5 13.2 26.4 Units Max. Units % % % 150 ±0.03 mV P - P %/ºC Max. Units VDC M pF kHz VDC Output Parameter Output Voltage Accuracy Output Voltage Balance Line Regulation Load Regulation Ripple & Noise (20 MHz) Temperature Coefficient Output Short Circuit Conditions Min. Typ. ±2.5 Dual Output, Balanced Loads ±1.0 For VIN Change of 1% ±1.2 See Model Selection Guide 75 Momentary (1.0 Sec.) General Parameter Isolation Voltage Isolation Resistance Isolation Capacitance Switching Frequency EMI Characteristics, See Note 3 Parameter Conducted Emissions ESD Conditions 60 Seconds 500 VDC 100 kHz, 1V Conditions Min. 3,000 1,000 Typ. 100 70 Min. Typ. Max. Units Class B Criteria B; ±8 kV Contact Min. Typ. -40 -55 Free Air Convection RH, Non-condensing Max. +85 +125 Units ºC ºC 95 % EN 55022 EN 61000-4-2 Environmental MicroPower Direct 292 Page Street Suite D Stoughton, MA 02072 USA T: (781) 344-8226 F: (781) 344-8481 E: [email protected] W: www.micropowerdirect.com Parameter Operating Temperature Range Storage Temperature Range Cooling Humidity Physical Case Size Case Material Weight Conditions Ambient 0.787 x 0.394 x 0.323 Inches (20.0 x 10.0 x 8.2 mm) Non-Conductive Black Plastic (UL94-V0) 0.07 Oz (2.1g) Reliability Specifications Parameter MTBF Safety Standards Conditions Min. Typ. MIL HDBK 217F, 25ºC, Gnd Benign 3.5 UL 1950, EN 60950 Max. Units MHours Max. 9.0 18.0 30.0 300 Units Absolute Maximum Ratings Parameter Conditions Input Voltage Surge (1 Sec) Lead Temperature 5 VDC Input 12 VDC Input 24 VDC Input 1.5 mm From Case For 10 Sec Min. -0.7 -0.7 -0.7 Typ. Caution: Exceeding Absolute Maximum Ratings may damage the module. These are not continuous operating ratings. www.micropowerdirect.com VDC ºC www.micropowerdirect.com Model Selection Guide Model Number G201EI G202EI G203EI G204EI G205EI G207EI G208EI G211EI G212EI G213EI G214EI G215EI G217EI G218EI G221EI G222EI G223EI G224EI G225EI G227EI G228EI Input Voltage (VDC) Current (mA) Voltage Nominal Range Full-Load No-Load (VDC) 5 4.5 - 5.5 508 32 5.0 5 4.5 - 5.5 474 30 9.0 5 4.5 - 5.5 469 33 12.0 5 4.5 - 5.5 474 36 15.0 5 4.5 - 5.5 477 37 ±5.0 5 4.5 - 5.5 455 33 ±12.0 5 4.5 - 5.5 464 40 ±15.0 12 10.8 - 13.2 203 16 5.0 12 10.8 - 13.2 201 24 9.0 12 10.8 - 13.2 195 19 12.0 12 10.8 - 13.2 197 18 15.0 12 10.8 - 13.2 203 18 ±5.0 12 10.8 - 13.2 190 19 ±12.0 12 10.8 - 13.2 199 19 ±15.0 24 21.6 - 26.4 98 9 5.0 24 21.6 - 26.4 92 7 9.0 24 21.6 - 26.4 95 9 12.0 24 21.6 - 26.4 95 7 15.0 24 21.6 - 26.4 99 9 ±5.0 24 21.6 - 26.4 93 8 ±12.0 24 21.6 - 26.4 98 11 ±15.0 Output Current Current (mA, Max) (mA, Min) 400.0 222.0 167.0 133.0 ±200.0 ±83.0 ±67.0 400.0 222.0 167.0 133.0 ±200.0 ±83.0 ±67.0 400.0 222.0 167.0 133.0 ±200.0 ±83.0 ±67.0 Load Regulation % Typ. % Max. 10.0 8.3 6.8 6.3 ±10.0 ±6.8 ±6.3 10.0 8.3 6.8 6.3 ±10.0 ±6.8 ±6.3 10.0 8.3 6.8 6.3 ±10.0 ±6.8 ±6.3 15 15 15 15 15 15 15 15 15 15 15 15 15 15 15 15 15 15 15 15 15 40.0 23.0 17.0 14.0 ±20.0 ±9.0 ±7.0 40.0 23.0 17.0 14.0 ±20.0 ±9.0 ±7.0 40.0 23.0 17.0 14.0 ±20.0 ±9.0 ±7.0 Notes: 1. Output load regulation is specified for a load change of 10% to 100%. 2. Operation at no load will not damage the units, but they may not meet all specifications. Recommended minimum load is given in the Model Selection Table above. 3. These converters will operate without external components. However, to meet the specified EMI limits, a simple external circuit is required. See the typical connection note at right for more information. 4. Output power should be derated linearly from 100% at 85°C to 0% at 105°C. 5. It is recommended that a fuse be used on the input of a power supply for protection. See the Model Selection table above for the correct rating. Rating Efficiency Fuse Slow-Blow (%, Typ) (mA) 81 83 83 83 82 84 82 80 82 83 83 80 85 82 80 82 83 84 82 85 85 1,000 1,000 1,000 1,000 1,000 1,000 1,000 500 500 500 500 500 500 500 250 250 250 250 250 250 250 Typical Connection Pin Connections Pin Single Dual 1 -Vin -Vin 7 NC NC 8 -Vout Common Pin Single 9 +Vout 11 No Pin 14 +Vin Dual +Vout -Vout +Vin Mechanical Dimensions These converters will operate without external components. However, to further decrease input/output ripple, the simple circuit shown above is recommended. Input Vout Capacitor 5 VDC 4.7 µF 5 VDC 12 VDC 2.2 µF 9 VDC 24 VDC 1.0 µF 12 VDC 15 VDC Vin Output Capacitors Single Dual 10.0 µF 4.7 µF 4.7 µF 2.2 µF 2.2 µF 1.0 µF 1.0 µF 0.47 µF The table above gives the recommended values. Capacitors should be mounted as close to the converter as possible. For applications requiring very low output noise levels, a simple LC filter should be effective. Notes: • All dimensions are typical in inches (mm) • Tolerance x.xx = ±0.01 (±0.25) • Pin 1 is marked by a “dot” or indentation on the top of the unit MicroPower Direct We Power Your Success - For Less! 292 Page Street Ste D Stoughton, MA 02072 • TEL: (781) 344-8226 • FAX: (781) 344-8481 • E-Mail: [email protected]