G200EI Datasheet - Micropower Direct

G200EI Series
High Isolation, 2W
Compact MiniDIP
DC/DC Converters
Electrical Specifications
Specifications typical @ +25°C, nominal input voltage & rated output current, unless otherwise noted. Specifications subject to change without notice.
Key Features:
Input
• 2W Output Power
• Compact Mini-DIP Case
• EN60950 Approved
• Single & Dual Outputs
• 3,000 VDC Isolation
• >3.5 MHour MTBF
• 24 Standard Models
• LOW COST
Parameter
Conditions
Min.
Typ.
5 VDC Input
4.5
5.0
12 VDC Input 10.8
12.0
24 VDC Input 21.6
24.0
Internal Capacitor
Input Voltage Range
Input Filter
Max.
5.5
13.2
26.4
Units
Max.
Units
%
%
%
150
±0.03
mV P - P
%/ºC
Max.
Units
VDC
M
pF
kHz
VDC
Output
Parameter
Output Voltage Accuracy
Output Voltage Balance
Line Regulation
Load Regulation
Ripple & Noise (20 MHz)
Temperature Coefficient
Output Short Circuit
Conditions
Min.
Typ.
±2.5
Dual Output, Balanced Loads
±1.0
For VIN Change of 1%
±1.2
See Model Selection Guide
75
Momentary (1.0 Sec.)
General
Parameter
Isolation Voltage
Isolation Resistance
Isolation Capacitance
Switching Frequency
EMI Characteristics, See Note 3
Parameter
Conducted Emissions
ESD
Conditions
60 Seconds
500 VDC
100 kHz, 1V
Conditions
Min.
3,000
1,000
Typ.
100
70
Min.
Typ.
Max.
Units
Class B
Criteria B; ±8 kV Contact
Min.
Typ.
-40
-55
Free Air Convection
RH, Non-condensing
Max.
+85
+125
Units
ºC
ºC
95
%
EN 55022
EN 61000-4-2
Environmental
MicroPower Direct
292 Page Street
Suite D
Stoughton, MA 02072
USA
T: (781) 344-8226
F: (781) 344-8481
E: [email protected]
W: www.micropowerdirect.com
Parameter
Operating Temperature Range
Storage Temperature Range
Cooling
Humidity
Physical
Case Size
Case Material
Weight
Conditions
Ambient
0.787 x 0.394 x 0.323 Inches (20.0 x 10.0 x 8.2 mm)
Non-Conductive Black Plastic (UL94-V0)
0.07 Oz (2.1g)
Reliability Specifications
Parameter
MTBF
Safety Standards
Conditions
Min.
Typ.
MIL HDBK 217F, 25ºC, Gnd Benign
3.5
UL 1950, EN 60950
Max.
Units
MHours
Max.
9.0
18.0
30.0
300
Units
Absolute Maximum Ratings
Parameter
Conditions
Input Voltage Surge (1 Sec)
Lead Temperature
5 VDC Input
12 VDC Input
24 VDC Input
1.5 mm From Case For 10 Sec
Min.
-0.7
-0.7
-0.7
Typ.
Caution: Exceeding Absolute Maximum Ratings may damage the module. These are not continuous operating ratings.
www.micropowerdirect.com
VDC
ºC
www.micropowerdirect.com
Model Selection Guide
Model
Number
G201EI
G202EI
G203EI
G204EI
G205EI
G207EI
G208EI
G211EI
G212EI
G213EI
G214EI
G215EI
G217EI
G218EI
G221EI
G222EI
G223EI
G224EI
G225EI
G227EI
G228EI
Input
Voltage (VDC)
Current (mA)
Voltage
Nominal
Range
Full-Load No-Load (VDC)
5
4.5 - 5.5
508
32
5.0
5
4.5 - 5.5
474
30
9.0
5
4.5 - 5.5
469
33
12.0
5
4.5 - 5.5
474
36
15.0
5
4.5 - 5.5
477
37
±5.0
5
4.5 - 5.5
455
33
±12.0
5
4.5 - 5.5
464
40
±15.0
12
10.8 - 13.2
203
16
5.0
12
10.8 - 13.2
201
24
9.0
12
10.8 - 13.2
195
19
12.0
12
10.8 - 13.2
197
18
15.0
12
10.8 - 13.2
203
18
±5.0
12
10.8 - 13.2
190
19
±12.0
12
10.8 - 13.2
199
19
±15.0
24
21.6 - 26.4
98
9
5.0
24
21.6 - 26.4
92
7
9.0
24
21.6 - 26.4
95
9
12.0
24
21.6 - 26.4
95
7
15.0
24
21.6 - 26.4
99
9
±5.0
24
21.6 - 26.4
93
8
±12.0
24
21.6 - 26.4
98
11
±15.0
Output
Current
Current
(mA, Max)
(mA, Min)
400.0
222.0
167.0
133.0
±200.0
±83.0
±67.0
400.0
222.0
167.0
133.0
±200.0
±83.0
±67.0
400.0
222.0
167.0
133.0
±200.0
±83.0
±67.0
Load Regulation
% Typ.
% Max.
10.0
8.3
6.8
6.3
±10.0
±6.8
±6.3
10.0
8.3
6.8
6.3
±10.0
±6.8
±6.3
10.0
8.3
6.8
6.3
±10.0
±6.8
±6.3
15
15
15
15
15
15
15
15
15
15
15
15
15
15
15
15
15
15
15
15
15
40.0
23.0
17.0
14.0
±20.0
±9.0
±7.0
40.0
23.0
17.0
14.0
±20.0
±9.0
±7.0
40.0
23.0
17.0
14.0
±20.0
±9.0
±7.0
Notes:
1. Output load regulation is specified for a load change of 10% to 100%.
2. Operation at no load will not damage the units, but they may not meet all specifications. Recommended minimum
load is given in the Model Selection Table above.
3. These converters will operate without external components. However, to meet the specified EMI limits, a simple
external circuit is required. See the typical connection note at right for more information.
4. Output power should be derated linearly from 100% at 85°C to 0% at 105°C.
5. It is recommended that a fuse be used on the input of a power supply for protection. See the Model Selection
table above for the correct rating.
Rating
Efficiency Fuse
Slow-Blow
(%, Typ)
(mA)
81
83
83
83
82
84
82
80
82
83
83
80
85
82
80
82
83
84
82
85
85
1,000
1,000
1,000
1,000
1,000
1,000
1,000
500
500
500
500
500
500
500
250
250
250
250
250
250
250
Typical Connection
Pin Connections
Pin Single
Dual
1
-Vin
-Vin
7
NC
NC
8
-Vout Common
Pin Single
9
+Vout
11 No Pin
14
+Vin
Dual
+Vout
-Vout
+Vin
Mechanical Dimensions
These converters will operate without external components. However,
to further decrease input/output ripple, the simple circuit shown above
is recommended.
Input
Vout
Capacitor
5 VDC
4.7 µF
5 VDC
12 VDC
2.2 µF
9 VDC
24 VDC
1.0 µF 12 VDC
15 VDC
Vin
Output Capacitors
Single
Dual
10.0 µF
4.7 µF
4.7 µF
2.2 µF
2.2 µF
1.0 µF
1.0 µF
0.47 µF
The table above gives the recommended values. Capacitors should be
mounted as close to the converter as possible. For applications requiring
very low output noise levels, a simple LC filter should be effective.
Notes:
• All dimensions are typical in inches (mm)
• Tolerance x.xx = ±0.01 (±0.25)
• Pin 1 is marked by a “dot” or indentation on the top of the unit
MicroPower Direct
We Power Your Success - For Less!
292 Page Street Ste D Stoughton, MA 02072
•
TEL: (781) 344-8226
•
FAX: (781) 344-8481
•
E-Mail: [email protected]