60W Multiple-Stage Output Current LED Power Supply LCM-60 series ■ Features : Output current level selectable by DIP S.W. 180~295VAC input only Built-in active PFC function Protections: Short circuit / Over voltage / Over temperature Cooling by free air convection Fully isolated plastic case Class Ⅱ power unit, no FG Built-in 0~10Vdc or PWM signal or resistance dimming function(NTC is not used) Built-in 12V/50mA auxiliary output Temperature compensation function by external NTC No load power consumption <1W(Note.7) Power supplies synchronization function up to 10 units Suitable for indoor LED lighting applications 3 years warranty F SPECIFICATION MODEL OUTPUT 110 M M SELV LCM-60 SELECTABLE CURRENT Note.3 500mA 600mA 700mA 900mA 1050mA 1400mA DC VOLTAGE RANGE 2 ~ 90V 2 ~ 90V 2 ~ 86V 2 ~ 67V 2 ~ 57V 2 ~ 42V RATED POWER 60.3W RIPPLE CURRENT ±5% RIPPLE & NOISE (max.) Note.2 700mVp-p NO LOAD OUTPUT VOLTAGE (max.) 95V SETUP, RISE TIME Note.5 500ms, 80ms / 230VAC at rated power HOLD UP TIME (Typ.) VOLTAGE RANGE INPUT 16ms/230VAC at rated power Note.4 180 ~ 295VAC 47 ~ 63Hz POWER FACTOR (Typ.) PF≧0.975/230VAC, PF≧0.96/277VAC at rated power (Please refer to "Power Factor Characteristic" curve) TOTAL HARMONIC DISTORTION Total harmonic distortion will be lower than 20% when output loading is 75% or higher EFFICIENCY (Typ.) Note.6 92% AC CURRENT (Typ.) INRUSH CURRENT(Typ.) 0.32A/230VAC 0.27A/277VAC COLD START 20A(twidth=270μs measured at 50% Ipeak) at 230VAC MAX. No. of PSUs on 16A CIRCUIT BREAKER 25 units (circuit breaker of type B) / 32 units (circuit breaker of type C) at 230VAC LEAKAGE CURRENT <0.5mA / 240VAC SHORT CIRCUIT Constant current limiting, recovers automatically after fault condition is removed 105 ~ 125V Protection type : Shutdown o/p voltage, re-power on to recover OVER TEMPERATURE Shut down o/p voltage, re-power on to recover AUXILIARY POWER TEMP. COMPENSATION 12V @ 50mA for driving fan; Tolerance±5% By external NTC(not provide with the power supply), please see "Temperature Compensation Operation" DIMMING Please see "Dimming Operation" SYNCHRONIZATION Please see "Synchronization Operation" WORKING TEMP. -30 ~ +60℃ (Refer to "Derating Curve") WORKING HUMIDITY ENVIRONMENT STORAGE TEMP., HUMIDITY TEMP. COEFFICIENT SAFETY & EMC -40 ~ +80℃, 10 ~ 95% RH ±0.03%/℃ (0 ~ 50℃) 10 ~ 500Hz, 2G 10min./1cycle, period for 60min. each along X, Y, Z axes SAFETY STANDARDS UL8750, ENEC EN61347-1, EN61347-2-13, EN62384 independent, GB19510.14,GB19510.1 approved WITHSTAND VOLTAGE I/P-O/P:3.75KVAC ISOLATION RESISTANCE I/P-O/P:>100M Ohms / 500VDC / 25℃/ 70% RH Compliance to EN55015, EN61000-3-2 Class C(≧40% rated power) ; EN61000-3-3; GB17625.1,GB17743 EMC EMISSION EMC IMMUNITY DIMENSION PACKING NOTE 20 ~ 90% RH non-condensing VIBRATION MTBF OTHERS 254 ~ 417VDC FREQUENCY RANGE PROTECTION OVER VOLTAGE FUNCTION 73V ±5.0% CURRENT ACCURACY Compliance to EN61000-4-2,3,4,5,6,8,11, EN55024, EN61547 light industry level (surge 2KV), criteria A 260.6K hrs min. MIL-HDBK-217F (25℃) 123.5*81.5*23mm (L*W*H) 0.24Kg ; 54pcs/15Kg/1.12CUFT 1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25℃ of ambient temperature. 2. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1uf parallel capacitor. 3. Please see "DIP switch table". 4. Derating may be needed under low input voltage. Please check the static characteristics for more details. 5. Length of set up time is measured at first cold start. Turning ON/OFF the power supply may lead to increase of the set up time. 6. Efficiency is measured at 900mA/67V output set by DIP switch. 7. No load power consumption<1W is measured at 180~277VAC, with lighting fixture connected and output current dimmed to 0%. 8. The power supply is considered as a component that will be operated in combination with final equipment. Since EMC performance will be affected by the complete installation, the final equipment manufacturers must re-qualify EMC Directive on the complete installation again. 9. To fulfill requirements of the latest ErP regulation for lighting fixtures, this LED power supply can only be used behind a switch without permanently connected to the mains. File Name:LCM-60-SPEC 2015-07-15 LCM-60 60W Multiple-Stage Output Current LED Power Supply Mechanical Specification Case No.LCM-60A series Unit:mm 123.5 6.75 110 6.75 ※ T case: Max. Case Temperature. 15 6.75 1 2 6.75 40 4.2 TB1 2- T case 68 SYN. 1 CN101 2 3 CN100 4 1 2 TB5 ON 1 2 3 4 5 6 Bottom View Terminal Pin No. Assignment(TB3) 39.3 Pin No. 1 2 3 65.5 7.8 2-M3 Assignment +FAN -FAN +NTC Pin No. 4 5 6 Assignment -NTC DIM+ DIM- 4 7.8 Terminal Pin No. Assignment(TB5) Assignment +Vo -Vo 23 Pin No. 1 2 SYN. Connector(CN101/CN100):JST B2B-XH or equivalent Terminal Pin No. Assignment(TB1) Pin No. 1,3 2,4 Assignment AC/L AC/N Pin No. 1 2 Assignment + - Mating Housing Terminal JST XHP or equivalent JST SXH-001T-P0.6 or equivalent PFC fosc : 60KHz PWM fosc : 80KHz Block Diagram EMI FILTER & RECTIFIERS I/P POWER SWITCHING PFC CIRCUIT RECTIFIERS +12Vaux RECTIFIERS & FILTER +V -V DIM+ DIM- PWM CONTROL O.T.P. CURRENT LIMIT DETECTION CIRCUIT O.L.P. PFC CONTROL O.V.P. Derating Curve Static Characteristics 100 100 Others 90 80 80 70 40 LOAD (%) 60 LOAD (%) 81.5 TB3 1 2 3 4 5 6 1050mA / 1400mA 20 -30 -15 0 15 30 40 50 AMBIENT TEMPERATURE (℃) 60 70 (HORIZONTAL) 60 50 40 180 190 200 210 220 230 240 250 260 270 280 295 INPUT VOLTAGE (V) 60Hz File Name:LCM-60-SPEC 2015-07-15 LCM-60 60W Multiple-Stage Output Current LED Power Supply series DIP Switch Table LCM-60 is a multiple-stage output current supply, selection of output current through DIP switch as table below. DIP S.W. 1 2 3 4 5 6 500mA ---- ---- ---- ---- ---- ---- 600mA ON ---- ---- ---- ---- ---- 700mA(Factory Setting) ON ON ---- ---- ---- ---- 900mA ON ON ON ---- ---- ON 1050mA ON ON ON ON ---- ON 1400mA ON ON ON ON ON ON Io Power Factor Characteristic Constant Current Mode Constant Current Mode 1.00 0.97 0.94 500 0.88 600 0.85 700 0.82 900 0.79 1050 PF PF 0.91 1400 0.76 0.73 0.70 10% 20% 30% 40% 50% 60% 70% 80% 90% 100% (60W) 1.00 0.97 0.94 0.91 0.88 0.85 0.82 0.79 0.76 0.73 0.70 0.67 0.64 0.61 0.58 0.55 0.52 0.49 500 600 700 900 1050 1400 10% 20% 30% 40% 50% 60% 70% 80% 90% 100% (60W) LOAD (230Vac Input) LOAD (277Vac Input) EFFICIENCY vs LOAD 95.0% 95.0% 90.0% 90.0% 85.0% 85.0% 80.0% 500 75.0% 600 700 70.0% 900 65.0% 1050 60.0% 1400 55.0% EFFICIENCY (%) EFFICIENCY (%) LCM-60 series possess superior working efficiency that up to 92% can be reached in field applications. 80.0% 500 75.0% 600 70.0% 700 65.0% 900 60.0% 1050 55.0% 1400 50.0% 45.0% 40.0% 50.0% 10% 20% 30% 40% 50% 60% 70% 80% 90% 100% LOAD (230Vac Input) 10% 20% 30% 40% 50% 60% 70% 80% 90% 100% LOAD (277Vac Input) File Name:LCM-60-SPEC 2015-07-15 LCM-60 60W Multiple-Stage Output Current LED Power Supply series DIMMING OPERATION ※ Built-in 3 in 1 dimming function, output constant current level can be adjusted through output terminal by connecting a resistance or 0 ~ 10Vdc or 10V PWM signal between DIM+ and DIM-. ※ Please DO NOT connect "DIM-" to "-Vo". ※ Reference resistance value for output current adjustment (Typical) Short 10KΩ 20KΩ 30KΩ 40KΩ 50KΩ 60KΩ 70KΩ 80KΩ 90KΩ 100KΩ Single driver Resistance Multiple drivers value (N=driver quantity for synchronized Short 10KΩ/N 20KΩ/N 30KΩ/N 40KΩ/N 50KΩ/N 60KΩ/N 70KΩ/N 80KΩ/N 90KΩ/N 100KΩ/N OPEN ----- dimming operation) Percentage of rated current 0% 10% 20% 30% 40% 50% 60% 70% 80% 90% 100% 100%~108% ※ 0 ~ 10V dimming function for output current adjustment (Typical) Dimming value 0V 1V 2V 3V 4V 5V 6V 7V 8V 9V 10V OPEN Output current 0% 10% 20% 30% 40% 50% 60% 70% 80% 90% 100% 100%~108% ※ 10V PWM signal for output current adjustment (Typical): Frequency range :100Hz ~ 3KHz Duty value 0% 10% 20% 30% 40% 50% 60% 70% 80% 90% 100% OPEN Output current 0% 10% 20% 30% 40% 50% 60% 70% 80% 90% 100% 100%~108% ◎ Dimming Characteristic 100 Output Current Percentage of rated current(%) 90 Note 80 70 60 50 40 30 20 10 0 0V 1V 2V 3V 4V 5V 6V 7V 8V 9V 10V 0% 10% 20% 30% 40% 50% 60% 70% 80% 90% 100% Short 10K 20K 30K 40K 50K 60K 70K 80K 90K 100K Dimming input 0~10V Duty cycle of 10V PWM (frequency range = 100~3KHz) Short~100KΩresistance ※ Note : The output current drops down to 0% when the dimming input is about 6KΩor 0.6Vdc, or 10V PWM signal with 6% duty cycle. File Name:LCM-60-SPEC 2015-07-15 LCM-60 60W Multiple-Stage Output Current LED Power Supply series SYNCHRONIZATION OPERATION 10 drivers(max.) synchronization (1 master + 9 slaves) Maximum cable length between each units : 20 meter. SYN. - - LCM-60 (Slave 1) + + + + LCM-60 (Master) 20m SYN. - - + + SYN. - - LCM-60 (Slave 2) 20m TEMPERATURE COMPENSATION OPERATION NTC derating curve 105 100 220KO 220KΩ Output Io (%) 95 330KO 330KΩ 470KO 470KΩ 90 85 80 75 70 65 55 60 65 70 75 80 85 90 95 Sensed Temperature(degree) LCM-60 have the built-in temperature compensation function (T↑,Io↓). By connecting a temperature sensor (NTC resistor) between the NTC +/terminal of LCM-60 and the detecting point on the lighting system or the surrounding environment, output current of LCM-60 could be correspondingly changed to ensure the long life of LED. 1.LCM-60 can still be operated well when the NTC resistor is not connected and the value of output current will be the current level that you set through the DIP switch. 2. NTC resistance Output Current 220K < 60℃, 100% of the rated current (corresponds to the setting current level) > 60℃, output current begin to reduce, details please refer to the curve. 330K < 70℃, 100% of the rated current (corresponds to the setting current level) > 70℃, output current begin to reduce, details please refer to the curve. 470K < 80℃, 100% of the rated current (corresponds to the setting current level) > 80℃, output current begin to reduce, details please refer to the curve. Notes: 1. MW does not offer the NTC resistor and all the data above are measured by using THINKING TTC03 series. 2. If other brands of NTC resistor is applied,please check the temperature curve first. File Name:LCM-60-SPEC 2015-07-15