Test Report: LPF‐60D‐15 60W Single Output Switching Power Supply DESIGN VERIFY TEST Output Function Test Input Function Test Protection Function Test Component Stress Test SAFETY & E.M.C. TEST Safety Test E.M.C. Test RELIABILITY TEST ENVIRONMENT TEST LPF-60D series DESIGN VERIFY TEST OUTPUT FUNCTION TEST NO 1 TEST ITEM SPECIFICATION TEST CONDITION RIPPLE & NOISE V1:150 I/P: 230VAC mVp-p (Max ) RESULT VERDICT V1: 15.4 mVp-p O/P:FULL LOAD (Max ) P Ta:25℃ 2 CONSTANT CURRENT V1= 9V~15V REGION I/P: 230VAC O/P= 9V: 4.21 A O/P:CV MODE O/P= 14V: 4.21 A P Ta:25℃ 3 OUTPUT VOLTAGE V1: 4 %~ -4 % (Max) I/P:100 VAC / 305 VAC O/P:FULL/ MIN TOLERANCE V1: 0.4 %~ -0.4 % LOAD P Ta:25℃ 4 LINE REGULATION V1: 0.5 %~ -0.5 % (Max) I/P:100 VAC ~ 305 VAC V1: 0.04 %~ -0.04 % O/P:FULL LOAD P Ta:25℃ 5 LOAD REGULATION V1:1.5 %~ -1.5 % (Max) I/P: 230 VAC V1: 0.4 %~ -0.4 % O/P:FULL ~MIN LOAD P Ta:25℃ 6 SET UP TIME 230VAC: 500 ms (Max) I/P: 230 VAC 230VAC/ 274 ms 115VAC: 1000 ms(Max) I/P: 115 VAC 115VAC/ 350 ms P O/P:FULL LOAD Ta:25℃ 7 RISE TIME 230VAC: 80 ms (Max) I/P: 230 VAC 230VAC/ 13 ms 115VAC: 80 ms (Max) I/P: 115 VAC 115VAC/ 13 ms P O/P:FULL LOAD Ta:25℃ 8 HOLD UP TIME 230VAC: 16 ms (TYP) I/P: 230 VAC 230VAC/ 61 ms 115VAC: 16 ms (TYP) I/P: 115 VAC 115VAC/ 34 ms P O/P:FULL LOAD Ta:25℃ 9 OVER/UNDERSHOOT I/P: 230 VAC < +5% TEST: <5 % P O/P:FULL LOAD TEST Ta:25℃ 10 DYNAMIC LOAD V1: 1500 mVp-p I/P: 230 VAC (1)378 mVp-p (1).O/P:FULL /Min LOAD 90%DUTY/ (2)422 mVp-p 1KHZ (2).O/P:FULL /Min LOAD 50%DUTY/ P 120HZ Ta:25℃ Model: LPF-60D-15 Test Report 2 / 8 LPF-60D series 11 DIMMER TEST SPEC: *Output constant current level can be adjusted through output cable by 1 ~ 10Vdc, PWM signal or resistor between ADJ1(+) and ADJ2(-). *Reference resistance value for output current adjustment (Typical) Resistance value Output current 10K 20K 30K 40K 50K 60K 70K 80K 90K 100K 10% 20% 30% 40% 50% 60% 70% 80% 90% 100% *1 ~ 10V dimming function for output current adjustment (Typical) Dimming value Output current 1V 2V 3V 4V 5V 6V 7V 8V 9V 10V 10% 20% 30% 40% 50% 60% 70% 80% 90% 100% *10V PWM signal for output current adjustment (Typical) Duty value 10% 20% 30% 40% 50% 60% 70% 80% 90% 100% Output current 10% 20% 30% 40% 50% 60% 70% 80% 90% 100% P TEST RESULT: I/P: 230 VAC ;Ta:25℃ 1 Resistance value Output current 10K 20K 30K 40K 50K 60K 70K 80K 90K 100K 0.448A 0.836A 1.232A 1.628A 2.017A 2.409A 2.786A 3.170A 3.597A 3.975A 11.20% 20.90% 30.80% 40.70% 50.43% 60.23% 69.65% 79.25% 89.93% 99.38% 1V 2V 3V 4V 5V 6V 7V 8V 9V 10V 0.463A 0.867A 1.278A 1.680A 2.091A 2.493A 2.896A 3.302A 3.705A 4.015A % 11.58% 21.68% 31.95% 42.00% 52.28% 62.33% 72.40% 82.55% 92.63% 100.38% Duty value 10% 20% 30% 40% 50% 60% 70% 80% 90% 100% Output current 0.367A 0.788A 1.207A 1.627A 2.047A 2.467A 2.889A 3.310A 3.732A 4.005A % 9.18% 19.70% 30.18% 40.68% 51.18% 61.68% 72.23% 82.75% 93.30% 100.13% % 2 3 Dimming value Output current Model: LPF-60D-15 Test Report 3 / 8 LPF-60D series INPUT FUNCTION TEST NO 1 TEST ITEM SPECIFICATION INPUT VOLTAGE RANGE TEST CONDITION 100VAC~305 VAC RESULT I/P:TESTING VERDICT 73 V~305V O/P:FULL LOAD Ta:25℃ I/P: TEST: OK LOW-LINE-3V=97 V P HIGH-LINE=305 V O/P:FULL/MIN LOAD ON: 30 Sec . OFF: 30 Sec 10MIN ( AC POWER ON/OFF NO DAMAGE ) 2 INPUT FREQUENCY RANGE I/P: 100 VAC ~ 305 VAC 47HZ ~63 HZ TEST: OK P O/P:FULL~MIN LOAD NO DAMAGE OSC Ta:25℃ 3 POWER FACTOR 0.95 / 230 VAC(TYP) I/P: 230 VAC PF= 0.972 / 100% 0.98 / 115 VAC(TYP) I/P: 115 VAC PF= 0.997 / 100% 0.92 / 277 VAC(TYP) I/P: 277 VAC PF= 0.93 /100% 89.29 % P O/P:FULL LOAD Ta:25℃ 4 EFFICIENCY I/P: 230 VAC 87% (TYP) P O/P:FULL LOAD Ta:25℃ 5 INPUT CURRENT 230V/ 115V/ 0.4 0.8 A (TYP) I/P: 230 VAC I= 0.29 A/ 230 VAC A (TYP) I/P: 115 VAC I= 0.59 A/ 115 VAC I= 45 A/ 230 VAC O/P:FULL LOAD P Ta:25℃ 6 INRUSH CURRENT 230V/ 55 A (TYP) LEAKAGE CURRENT < P O/P:FULL LOAD COLD START 7 I/P: 230 VAC Ta:25℃ 0.75 mA / 240 VAC I/P: 277 VAC L-CASE: 0.01 mA O/P:Min LOAD N-CASE: 0.01 mA P Ta:25℃ Model: LPF-60D-15 Test Report 4 / 8 LPF-60D series PROTECTION FUNCTION TEST NO 1 TEST ITEM SPECIFICATION TEST CONDITION OVER LOAD PROTECTION 95 % ~ 108 % I/P: 230 VAC I/P: 115 VAC RESULT VERDICT 105 %/ 230 VAC 105 %/ 115 VAC O/P:TESTING Constant Current Limiting ,recovers Ta:25℃ automatically after fault condition is P removed. 2 OVER VOLTAGE PROTECTION CH1: 17.5 V ~ 21 V I/P: 230 VAC I/P: 115 VAC 3 OVER TEMPERATURE PROTECTION SPEC: Shut down and latch off o/p voltage, Ta:25℃ re-power on to recover O/P:FULL LOAD NO DAMAGE 4 SHORT PROTECTION 19.35 V/ 115 VAC O/P:MIN LOAD I/P: 230 VAC RTH2: 90+ 10℃ O.T.P. 19.35 V/ 230 VAC P O.T.P. Active Shut down o/p voltage, re-power on P to recover SHORT EVERY OUTPUT I/P: 305 VAC NO DAMAGE 1 HOUR NO DAMAGE O/P:FULL LOAD Hiccup Ta:25℃ automatically after fault condition is mode, recovers P removed. COMPONENT STRESS TEST NO 1 TEST ITEM SPECIFICATION TEST CONDITION Power Transistor Q 3 Rated: I/P:High-Line +3V = 308 V (1) 664 V ( D to S) or (C to E) Peak Voltage 2SK3673-01MR 10A/700V O/P: (1)Full Load Turn on (2) 536 V (3) 652 V (2) Output Short RESULT VERDICT P (3)Fulll load continue Ta:25℃ 2 Diode Peak Voltage D101 Rated: I/P:High-Line +3V = 308 V (1) 71.2 V STPS30M100ST 30A/100V O/P: (1)Full Load Turn on (2) 72 V (3) 70.8 V (2)Output Short P (3)Fulll load continue Ta:25℃ 4 Input Capacitor Voltage C5 Rated: I/P:High-Line +3V = 308 V (1) 427.18 V 47u/450V 105℃ 16*25 KXJ O/P: (1)Full Load Turn on /Off (2) 421.30 V (2) Min load Turn on /Off (3) 422.83 V P (3)Full Load /Min load Change Ta:25℃ 5 Control IC Voltage Test U 1 Rated: I/P:High-Line +3V = 308 V (1) 22.246 V PFC FAN6921MR 17V~30V O/P: (1)Full Load Turn on /Off (2) 22.050 V (2) Min load Turn on /Off (3) 22.048 V P (3)Full Load /Min load Change Ta:25℃ 6 Power Transistor Q1 Rated: I/P:High-Line +3V = 308 V (1) 468 V ( D to S) or (C to E) Peak Voltage STP11NK50ZFP 10A/500V O/P: (1)Full Load Turn on (2) 418 V (3) 454 V (2) Output Short P (3)Fulll load continue Ta:25℃ Model: LPF-60D-15 Test Report 5 / 8 LPF-60D series SAFETY & E.M.C. TEST SAFETY TEST NO 1 TEST ITEM SPECIFICATION TEST CONDITION RESULT WITHSTAND VOLTAGE I/P-O/P: 3.75 KVAC/min I/P-O/P: 4 KVAC/min I/P-O/P: VERDICT 2.508 mA P Ta:25℃ NO DAMAGE 2 ISOLATION RESISTANCE I/P-O/P:500VDC>100MΩ I/P-O/P: 500 VDC I/P-O/P: 30 GΩ P Ta:25℃/70%RH NO DAMAGE 3 APPROVAL TUV: Certificate NO : N/A UL: File NO : E.M.C TEST NO 1 TEST ITEM SPECIFICATION TEST CONDITION RESULT HARMONIC EN61000-3-2 I/P:230VAC/240VAC/220VAC50HZ PASS CLASS C O/P:100%,75%,60%LOAD CLASS C ≧60% VERDICT P Ta:25℃ 2 3 4 5 CONDUCTION RADIATION E.S.D E.F.T EN55022 I/P: 230 VAC (50HZ)/115V[60HZ] PASS CLASS B O/P:FULL/60% LOAD Ta:25℃ Test by certified Lab EN55022 I/P: 230 VAC (50HZ)/115V[60HZ] PASS CLASS B O/P:FULL LOAD Ta:25℃ Test by certified Lab AIR:8KV / Contact:6KV I/P: 230 VAC/50HZ CRITERIA A INDUSTRY O/P:FULL LOAD Ta:25℃ EN61000-4-4 I/P: 230 VAC/50HZ INDUSTRY O/P:FULL LOAD Ta:25℃ INPUT: 2KV 6 SURGE IEC61000-4-5 I/P: 230 VAC/50HZ INDUSTRY O/P:FULL LOAD Ta:25℃ L-N :2KV 7 P P P CRITERIA A P CRITERIA A P Test by certified Lab & Test Report Prepare Model: LPF-60D-15 Test Report 6 / 8 LPF-60D series RELIABILITY TEST ENVIRONMENT TEST NO 1 TEST ITEM SPECIFICATION TEMPERATURE RISE TEST MODEL:LPF-60-12 TEST CONDITION RESULT VERDICT 1. ROOM AMBIENT BURN-IN:4 HRS I/P: 230VAC O/P:95%LOAD Ta=28.3℃ 2. HIGH AMBIENT BURN-IN: 2.5 HRS I/P: 230VAC O/P: 95% LOAD Ta=54.1℃ NO 1 2 3 4 5 6 7 8 9 RTH2 LOW TEMPERATURE TR853A 4A/800V SILICON UR4KB80 50.4 74.2 Q1 STP11NK50ZFP 10A/500V 56.9 80.2 D2 2A/800V GP20K 70.2 94.3 Q3 2SK3673-01MR 10A/700V 70.5 94.2 C16 22u/50V UL10Kh 5*11 YXM 61.2 84.7 U1 PFC FAN6921MR 62.2 86.1 C201 67.8 91.6 59.5 82.9 58.3 81.5 C105 47u/50V UL10Kh 6.3*11 YXM NTC 100KΩ 3Φ TTC3A104F4193EY 1% 47u/450V 105 16*25 KXJ 820u/25V UL10Kh 10*20 ZLH 72.4 96.9 D101 PFR30L60CT 30A/60V 75.7 100.7 C5 C111 330u/25V UL8Kh 8*11.5 ZLH 68.6 92.7 LF100 TR895-R2 68.4 92.8 D1 MUR460 4A/600V 58.8 82.0 LF1 TR732A-R1 40.3 64.1 T1 TF2222 53.6 77.5 TURN ON AFTER 2 HOUR I/P: 305VAC/100VAC Ta= HIGH VOLTAGE IN CHAMBER ON CONTROL 50 ℃ O/P:95% LOAD TURN ON TEST NO DAMAGE HUMIDITY= TEMPERATURE + 0.03 %(0~50℃) P TEST:OK P Ta= 50 ℃ 95 %R.H I/P: 230 VAC + 0.01 %(0~50℃) O/P:95% LOAD COEFFICIENT 5 TEST:OK ℃ I/P: 305 VAC HIGH TEMPERATURE 4 -30 AFTER 12 HOURS HIGH HUMIDITY P O/P: 95 ﹪LOAD TURN ON TEST 3 ROOM AMBIENT HIGH AMBIENT Ta=28.3 ℃ Ta= 54.1 ℃ 51.8 75.5 P/N L1 BD1 10 11 13 14 15 16 17 18 2 Position STORAGE TEMPERATURE 1. Thermal shock Temperature: -45℃~ +90℃ TEST 2. Temperature change rate :25℃ / MIN P OK 3. Dwell time low and high temperature : 30 MIN/EACH P 4. Total test cycle:5 CYCLE 5. Input/Output condition: STATIC 6 THERMAL SHOCK TEST 1. Thermal shock Temperature: -35℃~ +55℃ OK 2. Temperature change rate :25℃ / MIN 3. Dwell time low and high temperature : 30 MIN/EACH P 4. Total test cycle:10 CYCLE 5. Input/Output condition: 230VAC/Full Load AC ON/OFF TEST turn on 58sec;turn off 2sec Model: LPF-60D-15 Test Report 7 / 8 LPF-60D series 7 VIBRATION TEST TEST:OK 1 Carton & 1 Set (1) Waveform: Sine Wave (2) Frequency:10~500Hz (3) Sweep Time:12min/sweep cycle P (4) Acceleration:5G (5) Test Time:72min in each axis (X.Y.Z) (6) Ta:25℃ 8 CAPACITOR LIFE CYCLE 9 10 (1) 125577 HRS (2) I/P: 230VAC (2) 24302 HRS (3) 41094 HRS O/P:FULL LOAD Ta=50 ℃ (3) I/P: 230VAC O/P:75% LOAD Ta= 50 ℃ MIL-HDBK-217F NOTICES2 PARTS COUNT TOTAL FAILURE RATE:440.5 HRS MTBF DMTBF/Accelerated Life Test DATE LPF-60-12: SUPPOSE C105 IS THE MOST CRITICAL COMPONENT (1) I/P: 230VAC O/P:FULL LOAD Ta=25 ℃ LIFE TIME LIFE TIME LIFE TIME P P Demonstration Mean Time Between Failure(Expected Life) : 30,000 hours @ Tcase 80℃; 50,000 hours @ Tcase70℃ P SAMPLE TEST RESULT TESTER APPROVAL 2010/11/11 RD SAMPLE PASS SANFORD SU VINCENT TSENG 2010/11/25 PRODUCT SAMPLE PASS SANFORD SU VINCENT TSENG 2009/08/04 Model: LPF-60D-15 A50-F023 Test Report 8 / 8