Test Report: LPF-60D-36

 Test Report: LPF‐60D‐36 60W Single Output Switching Power Supply  DESIGN VERIFY TEST
Output Function Test
Input Function Test
Protection Function Test
Component Stress Test
 SAFETY & E.M.C. TEST
Safety Test
E.M.C. Test
 RELIABILITY TEST
ENVIRONMENT TEST
LPF-60D series
 DESIGN VERIFY TEST
OUTPUT FUNCTION TEST
NO
1
TEST ITEM
SPECIFICATION
TEST CONDITION
RIPPLE & NOISE
V1:250
I/P: 230VAC
mVp-p (Max )
RESULT
VERDICT
V1:
21.2
mVp-p (Max )
O/P:FULL LOAD
P
Ta:25℃
2
CONSTANT
CURRENT
V1= 21.6V~36V
REGION
I/P: 230VAC
O/P=
21V:
1.76
A
O/P:CV MODE
O/P=
35V:
1.76
A
P
Ta:25℃
3
OUTPUT VOLTAGE
V1: 4
%~ -4
% (Max)
I/P:100 VAC / 305 VAC
O/P:FULL/ MIN
TOLERANCE
V1:
0.07
%~
-0.07
%
LOAD
P
Ta:25℃
4
LINE REGULATION
V1: 0.5 %~ -0.5 % (Max)
I/P:100 VAC ~ 305 VAC
V1:
0.02
%~
-0.02
%
O/P:FULL LOAD
P
Ta:25℃
5
LOAD REGULATION
V1:0.5 %~
-0.5 % (Max)
I/P: 230 VAC
V1:
0.07
%~
-0.07
%
O/P:FULL ~MIN LOAD
P
Ta:25℃
6
SET UP TIME
230VAC:
500
ms (Max)
I/P: 230 VAC
230VAC/
274
ms
115VAC:
1000
ms(Max)
I/P: 115 VAC
115VAC/
350
ms
P
O/P:FULL LOAD
Ta:25℃
7
RISE TIME
230VAC:
80
ms (Max)
I/P: 230 VAC
230VAC/
18
ms
115VAC:
80
ms (Max)
I/P: 115 VAC
115VAC/
19
ms
P
O/P:FULL LOAD
Ta:25℃
8
HOLD UP TIME
230VAC:
16
ms (TYP)
I/P: 230 VAC
230VAC/
68
ms
115VAC:
16
ms (TYP)
I/P: 115 VAC
115VAC/
34
ms
P
O/P:FULL LOAD
Ta:25℃
9
OVER/UNDERSHOOT
I/P: 230 VAC
< +5%
TEST:
<5
%
P
O/P:FULL LOAD
TEST
Ta:25℃
10
DYNAMIC LOAD
V1:
3600
mVp-p
I/P: 230 VAC
(1)268
mVp-p
(1).O/P:FULL /Min LOAD 90%DUTY/
(2)326
mVp-p
1KHZ
(2).O/P:FULL /Min LOAD 50%DUTY/
P
120HZ
Ta:25℃
Model: LPF-60D-36
Test Report
2 / 8
LPF-60D series
11
DIMMER TEST
SPEC:
*Output constant current level can be adjusted through output cable by 1 ~ 10Vdc, PWM signal or
resistor between ADJ1(+) and ADJ2(-).
*Reference resistance value for output current adjustment (Typical)
Resistance
value
Output
current
10K 20K 30K 40K 50K 60K 70K 80K 90K 100K 10% 20% 30% 40% 50% 60% 70% 80% 90% 100% *1 ~ 10V dimming function for output current adjustment (Typical)
Dimming
value
Output
current
1V 2V 3V 4V 5V 6V 7V 8V 9V 10V 10% 20% 30% 40% 50% 60% 70% 80% 90% 100% *10V PWM signal for output current adjustment (Typical)
Duty value
10% 20% 30% 40% 50% 60% 70% 80% 90% 100% Output
current
10% 20% 30% 40% 50% 60% 70% 80% 90% 100% P
TEST RESULT: I/P: 230 VAC ;Ta:25℃
1
Resistance
value
Output
current
10K 20K 30K 40K 50K 60K 70K 80K 90K 100K 0.205A 0.365A
0.528A
0.692A
0.854A
1.014A
1.170A
1.328A 1.503A 1.663A 12.26% 21.86%
31.61%
41.41%
51.13%
60.73%
70.04%
79.53% 90.00% 99.56% 1V 2V 3V 4V 5V 6V 7V 8V 9V 10V 0.206A 0.369A
0.532A
0.696A
0.859A
1.020A
1.183A
1.346A 1.507A 1.673A %
12.35% 22.10%
31.86%
41.69%
51.44%
61.09%
70.83%
80.60% 90.24% 100.16%
Duty value
10% 20% 30% 40% 50% 60% 70% 80% 90% 100% Output
current
0.168A 0.337A
0.506A
0.676A
0.845A
1.014A
1.184A
1.355A 1.525A 1.674A %
10.06% 20.18%
30.30%
40.48%
50.60%
60.72%
70.90%
81.14% 91.32% 100.24%
%
2
3
Dimming
value
Output
current
INPUT FUNCTION TEST
NO
1
TEST ITEM
INPUT VOLTAGE RANGE
SPECIFICATION
100VAC~305 VAC
TEST CONDITION
I/P:TESTING
RESULT
VERDICT
74 V~305V
O/P:FULL LOAD
Ta:25℃
I/P:
TEST: OK
LOW-LINE-3V=97 V
P
HIGH-LINE=305 V
O/P:FULL/MIN LOAD
ON: 30 Sec . OFF: 30 Sec 10MIN
( AC POWER ON/OFF NO DAMAGE )
2
INPUT FREQUENCY
RANGE
47HZ ~63 HZ
NO DAMAGE OSC
I/P: 100 VAC ~ 305 VAC
TEST: OK
P
O/P:FULL~MIN LOAD
Ta:25℃
Model: LPF-60D-36
Test Report
3 / 8
LPF-60D series
3
POWER FACTOR
0.95
/ 230 VAC(TYP)
I/P: 230 VAC
PF=
0.974
/ 100%
0.98
/ 115 VAC(TYP)
I/P: 115 VAC
PF=
0.998
/ 100%
0.92
/ 277 VAC(TYP)
I/P: 277VAC
PF=
0.93
/ 100%
91.34
%
P
O/P:FULL LOAD
Ta:25℃
4
EFFICIENCY
I/P: 230 VAC
90% (TYP)
P
O/P:FULL LOAD
Ta:25℃
5
INPUT CURRENT
230V/
0.4
A (TYP)
I/P: 230 VAC
I=
0.29
A/ 230 VAC
115V/
0.8
A (TYP)
I/P: 115 VAC
I=
0.58
A/ 115 VAC
I=
52
A/ 230 VAC
O/P:FULL LOAD
P
Ta:25℃
6
INRUSH CURRENT
230V/
55
A (TYP)
LEAKAGE CURRENT
<
P
O/P:FULL LOAD
COLD START
7
I/P: 230 VAC
Ta:25℃
0.75
mA / 240 VAC
I/P: 277 VAC
L-CASE:
0.01
mA
O/P:Min LOAD
N-CASE:
0.01
mA
P
Ta:25℃
Model: LPF-60D-36
Test Report
4 / 8
LPF-60D series
PROTECTION FUNCTION TEST
NO
1
TEST ITEM
SPECIFICATION
TEST CONDITION
OVER LOAD PROTECTION
95 % ~ 108 %
I/P: 230 VAC
I/P: 115 VAC
RESULT
VERDICT
105 %/ 230 VAC
105 %/ 115 VAC
O/P:TESTING
Constant Current Limiting ,recovers
Ta:25℃
automatically after fault condition is
P
removed.
2
OVER VOLTAGE PROTECTION
CH1: 41
V ~ 49
V
I/P: 230 VAC
I/P: 115 VAC
3
OVER TEMPERATURE PROTECTION
SPEC:
Shut down and latch off o/p voltage,
Ta:25℃
re-power on to recover
O/P:FULL LOAD
NO DAMAGE
4
SHORT PROTECTION
44.1 V/ 115 VAC
O/P:MIN LOAD
I/P: 230 VAC
RTH2: 90+ 10℃ O.T.P.
44.1 V/ 230 VAC
P
O.T.P. Active
Shut down o/p voltage, re-power on
P
to recover
SHORT EVERY OUTPUT
I/P: 305 VAC
NO DAMAGE
1 HOUR NO DAMAGE
O/P:FULL LOAD
Hiccup
Ta:25℃
automatically after fault condition is
mode,
recovers
P
removed.
COMPONENT STRESS TEST
NO
1
TEST ITEM
SPECIFICATION
TEST CONDITION
Power Transistor
Q 3 Rated:
I/P:High-Line +3V = 308 V
(1)
632
V
( D to S) or (C to E) Peak Voltage
2SK3673-01MR 10A/700V
O/P: (1)Full Load Turn on
(2)
552
V
(3)
628
V
(2) Output Short
RESULT
VERDICT
P
(3)Fulll load continue
Ta:25℃
2
Diode Peak Voltage
D101 Rated:
I/P:High-Line +3V = 308 V
(1)
173
V
V20200C 20A/200V
O/P: (1)Full Load Turn on
(2)
189
V
(3)
163
V
(2)Output Short
P
(3)Fulll load continue
Ta:25℃
4
Input Capacitor Voltage
C5 Rated:
I/P:High-Line +3V = 308 V
(1)
425.07
V
47u/450V 105℃ 16*25 KXJ
O/P: (1)Full Load Turn on /Off
(2)
420.47
V
(2) Min load Turn on /Off
(3)
420.97
V
P
(3)Full Load /Min load
Change
Ta:25℃
5
Control IC Voltage Test
U 1 Rated:
I/P:High-Line +3V = 308 V
(1)
21.994
V
PFC FAN6921MR 17V~30V
O/P: (1)Full Load Turn on /Off
(2)
22.024
V
(2) Min load Turn on /Off
(3)
22.022
V
P
(3)Full Load /Min load
Change
Ta:25℃
6
Power Transistor
Q1 Rated:
I/P:High-Line +3V = 308 V
(1)
460
V
( D to S) or (C to E) Peak Voltage
STP11NK50ZFP 10A/500V
O/P: (1)Full Load Turn on
(2)
440
V
(3)
450
V
(2) Output Short
P
(3)Fulll load continue
Ta:25℃
Model: LPF-60D-36
Test Report
5 / 8
LPF-60D series
 SAFETY & E.M.C. TEST
SAFETY TEST
NO
1
TEST ITEM
SPECIFICATION
TEST CONDITION
RESULT
WITHSTAND VOLTAGE
I/P-O/P: 3.75 KVAC/min
I/P-O/P: 4 KVAC/min
I/P-O/P:
VERDICT
2.488
mA
P
Ta:25℃
NO DAMAGE
2
ISOLATION RESISTANCE
I/P-O/P:500VDC>100MΩ
I/P-O/P: 500
VDC
I/P-O/P:
30
GΩ
P
Ta:25℃/70%RH
NO DAMAGE
3
APPROVAL
TUV: Certificate NO :
N/A
UL: File NO :
E.M.C TEST
NO
1
TEST ITEM
SPECIFICATION
TEST CONDITION
RESULT
HARMONIC
EN61000-3-2
I/P:230VAC/240VAC/220VAC50HZ
PASS
CLASS C
O/P:100%,75%,60%LOAD
CLASS C ≧60%
VERDICT
P
Ta:25℃
2
3
4
5
CONDUCTION
RADIATION
E.S.D
E.F.T
EN55022
I/P: 230 VAC (50HZ)/115V[60HZ]
PASS
CLASS B
O/P:FULL/60% LOAD
Ta:25℃
Test by certified Lab
EN55022
I/P: 230 VAC (50HZ)/115V[60HZ]
PASS
CLASS B
O/P:FULL LOAD
Ta:25℃
Test by certified Lab
AIR:8KV / Contact:6KV
I/P: 230 VAC/50HZ
CRITERIA A
INDUSTRY
O/P:FULL LOAD
Ta:25℃
EN61000-4-4
I/P: 230 VAC/50HZ
INDUSTRY
O/P:FULL LOAD
Ta:25℃
INPUT: 2KV
6
SURGE
IEC61000-4-5
I/P: 230 VAC/50HZ
INDUSTRY
O/P:FULL LOAD
Ta:25℃
L-N :2KV
7
P
P
P
CRITERIA A
P
CRITERIA A
P
Test by certified Lab & Test Report Prepare
Model: LPF-60D-36
Test Report
6 / 8
LPF-60D series
 RELIABILITY TEST
ENVIRONMENT TEST
NO
1
TEST ITEM
SPECIFICATION
TEMPERATURE RISE TEST
MODEL:LPF-60-24
TEST CONDITION
RESULT
VERDICT
1. ROOM AMBIENT BURN-IN:4 HRS
I/P: 230VAC O/P:95% LOAD Ta=28.3
2. HIGH AMBIENT BURN-IN:2.5HRS
I/P: 230VAC O/P: 95% LOAD Ta=54.1
2
LOW TEMPERATURE
ROOM AMBIENT HIGH AMBIENT
NO
Position
P/N
1
L1
TR853A
2
BD1
50.2
73.5
3
Q1
STP11NK50ZFP 10A/500V
56.8
79.4
4
D2
2A/800V GP20K
67.2
91.3
5
Q3
2SK3673-01MR 10A/700V
66.8
90.5
6
C16
22u/50V UL10Kh 5*11 YXM
60.4
83.0
7
U1
PFC FAN6921MR
61.7
84.4
8
C201
62.2
84.7
9
RTH2
57.8
80.6
4A/800V
Ta=28.3
51.7
SILICON UR4KB80
Ta=54.1
74.7
10
C5
47u/50V UL10Kh 6.3*11 YXM
NTC 100KΩ 3Φ
TTC3A104F4193EY 1%
47u/450V 105℃ 16*25 KXJ
57.8
80.7
11
C105
820u/25V UL10Kh 10*20 ZLH
63.6
86.3
12
D101
YA868C15RSC 30A/150V
66.5
89.2
13
C111
220u/35V UL8Kh 8*11.5 ZLH
60.2
83.0
14
LF100
TR895-R2
59.1
82.0
15
D1
MUR460 4A/600V
58.4
81.1
16
LF1
TR732A-R1
41.3
64.6
17
T1
TF2200-R1
53.1
76.5
TURN ON AFTER
2 HOUR
I/P: 305VAC/100VAC
P
TEST:OK
O/P: 95 ﹪LOAD
TURN ON TEST
P
Ta=-30.0
3
AFTER 12 HOURS
I/P: 305 VAC
HIGH VOLTAGE
IN CHAMBER ON
CONTROL 50 ℃
O/P:95 ﹪LOAD
TURN ON TEST
NO DAMAGE
HUMIDITY=
HIGH HUMIDITY
HIGH TEMPERATURE
4
TEMPERATURE
+
0.03%(0~50℃)
P
Ta= 50 ℃
95 %R.H
I/P: 230 VAC
+ 0.004%(0~50℃)
O/P:95 LOAD
COEFFICIENT
5
TEST:OK
STORAGE TEMPERATURE
1. Thermal shock Temperature: -45℃~ +90℃
TEST
2. Temperature change rate :25℃ / MIN
P
OK
3. Dwell time low and high temperature : 30 MIN/EACH
P
4. Total test cycle:5 CYCLE
5. Input/Output condition: STATIC
6
THERMAL SHOCK TEST
1. Thermal shock Temperature: -35℃~ +55℃
OK
2. Temperature change rate :25℃ / MIN
3. Dwell time low and high temperature : 30 MIN/EACH
P
4. Total test cycle:10 CYCLE
5. Input/Output condition: 230VAC/Full Load AC ON/OFF TEST
turn on 58sec;turn off 2sec
Model: LPF-60D-36
Test Report
7 / 8
LPF-60D series
7
VIBRATION TEST
TEST:OK
1 Carton & 1 Set
(1) Waveform: Sine Wave
(2) Frequency:10~500Hz
(3) Sweep Time:12min/sweep cycle
P
(4) Acceleration:5G
(5) Test Time:72min in each axis (X.Y.Z)
(6) Ta:25℃
8
CAPACITOR
LIFE CYCLE
9
10

(1)
251516HRS
(2) I/P: 230VAC
(2)
55161HRS
(3)
78996HRS
O/P:FULL LOAD Ta=50 ℃ LIFE TIME
(3) I/P: 230VAC O/P:75% LOAD Ta=50 ℃
MIL-HDBK-217F NOTICES2 PARTS COUNT
TOTAL FAILURE RATE:440.5KHRS
MTBF
DMTBF/Accelerated Life Test
DATE
LPF-60-24 : SUPPOSE C105 IS THE MOST CRITICAL COMPONENT
(1) I/P: 230VAC O/P:FULL LOAD Ta=25 ℃ LIFE TIME
LIFE TIME
P
P
Demonstration Mean Time Between Failure(Expected Life) :
30,000 hours @ Tcase 80℃; 50,000 hours @ Tcase70℃
P
SAMPLE
TEST RESULT
TESTER
APPROVAL
2010/11/11
RD SAMPLE
PASS
SANFORD SU
VINCENT TSENG
2010/11/25
PRODUCT SAMPLE
PASS
SANFORD SU
VINCENT TSENG
2009/08/04
Model: LPF-60D-36
A50-F023
Test Report
8 / 8