Test Report: LPF‐40D‐15 40W Single Output Switching Power Supply DESIGN VERIFY TEST Output Function Test Input Function Test Protection Function Test Component Stress Test SAFETY & E.M.C. TEST Safety Test E.M.C. Test RELIABILITY TEST ENVIRONMENT TEST LPF-40D series DESIGN VERIFY TEST OUTPUT FUNCTION TEST NO 1 TEST ITEM SPECIFICATION TEST CONDITION RIPPLE & NOISE V1:150 I/P: 230VAC mVp-p (Max ) RESULT VERDICT V1: 9.4 mVp-p (Max ) O/P:FULL LOAD P Ta:25℃ 2 CONSTANT CURRENT V1= 9V~15V REGION I/P: 230VAC O/P= 9V: 2.799 A O/P:CV MODE O/P= 14V: 2.8 A P Ta:25℃ 3 OUTPUT VOLTAGE V1: 4 %~ -4 % (Max) I/P:100 VAC / 305 VAC O/P:FULL/ MIN TOLERANCE V1: 0.3 %~ -0.3 % LOAD P Ta:25℃ 4 LINE REGULATION V1: 0.5 %~ -0.5 % (Max) I/P:100 VAC ~ 305 VAC V1: 0 %~ 0 % O/P:FULL LOAD P Ta:25℃ 5 LOAD REGULATION V1:1.5 %~ -1.5 % (Max) I/P: 230 VAC V1: 0.29 %~ -0.29 % O/P:FULL ~MIN LOAD P Ta:25℃ 6 SET UP TIME 230VAC: 500 ms (Max) I/P: 230 VAC 230VAC/ 274 ms 115VAC: 1000 ms(Max) I/P: 115 VAC 115VAC/ 350 ms P O/P:FULL LOAD Ta:25℃ 7 RISE TIME 230VAC: 80 ms (Max) I/P: 230 VAC 230VAC/ 13 ms 115VAC: 80 ms (Max) I/P: 115 VAC 115VAC/ 13 ms P O/P:FULL LOAD Ta:25℃ 8 HOLD UP TIME 230VAC: 16 ms (TYP) I/P: 230 VAC 230VAC/ 69 ms 115VAC: 16 ms (TYP) I/P: 115 VAC 115VAC/ 36 ms P O/P:FULL LOAD Ta:25℃ 9 OVER/UNDERSHOOT I/P: 230 VAC < +5% TEST: <5 % P O/P:FULL LOAD TEST Ta:25℃ 10 DYNAMIC LOAD V1: 1500 mVp-p I/P: 230 VAC (1)257 mVp-p (1).O/P:FULL /Min LOAD 90%DUTY/ (2)338 mVp-p 1KHZ (2).O/P:FULL /Min LOAD 50%DUTY/ P 120HZ Ta:25℃ Model: LPF-40D-15 Test Report 2 / 8 LPF-40D series 11 DIMMER TEST SPEC: *Output constant current level can be adjusted through output cable by 1 ~ 10Vdc, PWM signal or resistor between ADJ1(+) and ADJ2(-). *Reference resistance value for output current adjustment (Typical) Resistance value Output current 10K 20K 30K 40K 50K 60K 70K 80K 90K 100K 10% 20% 30% 40% 50% 60% 70% 80% 90% 100% *1 ~ 10V dimming function for output current adjustment (Typical) Dimming value Output current 1V 2V 3V 4V 5V 6V 7V 8V 9V 10V 10% 20% 30% 40% 50% 60% 70% 80% 90% 100% *10V PWM signal for output current adjustment (Typical) Duty value 10% 20% 30% 40% 50% 60% 70% 80% 90% 100% Output current 10% 20% 30% 40% 50% 60% 70% 80% 90% 100% P TEST RESULT: I/P: 230 VAC ;Ta:25℃ 1 Resistance value Output current 10K 20K 30K 40K 50K 60K 70K 80K 90K 100K 0.347A 0.603A 0.866A 1.131A 1.393A 1.659A 1.915A 2.178A 2.472A 2.678A 13.00% 22.58% 32.43% 42.36% 52.17% 62.13% 71.72% 81.57% 92.58% 100.30% 1V 2V 3V 4V 5V 6V 7V 8V 9V 10V 0.349A 0.611A 0.869A 1.131A 1.395A 1.654A 1.916A 2.174A 2.440A 2.674A % 13.07% 22.88% 32.55% 42.36% 52.25% 61.95% 71.76% 81.42% 91.39% 100.15% Duty value 10% 20% 30% 40% 50% 60% 70% 80% 90% 100% Output current 0.289A 0.559A 0.828A 1.098A 1.367A 1.638A 1.909A 2.179A 2.451A 2.670A % 10.82% 20.94% 31.01% 41.12% 51.20% 61.35% 71.50% 81.61% 91.80% 100.00% % 2 3 Dimming value Output current Model: LPF-40D-15 Test Report 3 / 8 LPF-40D series INPUT FUNCTION TEST NO 1 TEST ITEM SPECIFICATION INPUT VOLTAGE RANGE TEST CONDITION 100VAC~305 VAC RESULT I/P:TESTING VERDICT 70 V~305V O/P:FULL LOAD Ta:25℃ I/P: TEST: OK LOW-LINE-3V=97 V P HIGH-LINE=305 V O/P:FULL/MIN LOAD ON: 30 Sec . OFF: 30 Sec 10MIN ( AC POWER ON/OFF NO DAMAGE ) 2 INPUT FREQUENCY RANGE I/P: 100 VAC ~ 305 VAC 47HZ ~63 HZ TEST: OK P O/P:FULL~MIN LOAD NO DAMAGE OSC Ta:25℃ 3 POWER FACTOR 0.95 / 230 VAC(TYP) I/P: 230 VAC PF= 0.976 / 100% 0.98 / 115 VAC(TYP) I/P: 115 VAC PF= 0.998 / 100% 0.92 / 277 VAC(TYP) I/P: 277 VAC PF= 0.93 / 100% 86.60 % P O/P:FULL LOAD Ta:25℃ 4 EFFICIENCY I/P: 230 VAC 85% (TYP) P O/P:FULL LOAD Ta:25℃ 5 INPUT CURRENT 230V/ 115V/ 0.4 0.8 A (TYP) I/P: 230 VAC I= 0.2 A/ 230 VAC A (TYP) I/P: 115 VAC I= 0.39 A/ 115 VAC I= 45 A/ 230 VAC O/P:FULL LOAD P Ta:25℃ 6 INRUSH CURRENT 230V/ 50 A (TYP) LEAKAGE CURRENT < P O/P:FULL LOAD COLD START 7 I/P: 230 VAC Ta:25℃ 0.75 mA / 240 VAC I/P: 277 VAC L-CASE: 0.01 mA O/P:Min LOAD N-CASE: 0.01 mA P Ta:25℃ Model: LPF-40D-15 Test Report 4 / 8 LPF-40D series PROTECTION FUNCTION TEST NO 1 TEST ITEM SPECIFICATION TEST CONDITION OVER LOAD PROTECTION 95 % ~ 108 % I/P: 230 VAC I/P: 115 VAC RESULT VERDICT 104.8 %/ 230 VAC 104.8 %/ 115 VAC O/P:TESTING Constant Current Limiting ,recovers Ta:25℃ automatically after fault condition is P removed. 2 OVER VOLTAGE PROTECTION CH1: 17.5 V ~ 21 V I/P: 230 VAC I/P: 115 VAC 3 OVER TEMPERATURE PROTECTION SPEC: Shut down and latch off o/p voltage, Ta:25℃ re-power on to recover O/P:FULL LOAD NO DAMAGE 4 SHORT PROTECTION 19.22 V/ 115 VAC O/P:MIN LOAD I/P: 230 VAC RTH2: 90+ 10℃ O.T.P. 19.22 V/ 230 VAC P O.T.P. Active Shut down o/p voltage, re-power on P to recover SHORT EVERY OUTPUT I/P: 305 VAC NO DAMAGE 1 HOUR NO DAMAGE O/P:FULL LOAD Hiccup Ta:25℃ automatically after fault condition is mode, recovers P removed. COMPONENT STRESS TEST NO 1 TEST ITEM SPECIFICATION TEST CONDITION Power Transistor Q 3 Rated: I/P:High-Line +3V = 308 V (1) 642 V ( D to S) or (C to E) Peak Voltage STP9NK70ZFP 7.5A/700V O/P: (1)Full Load Turn on (2) 504 V (3) 640 V (2) Output Short RESULT VERDICT P (3)Fulll load continue Ta:25℃ 2 Diode Peak Voltage D101 Rated: I/P:High-Line +3V = 308 V (1) 68.4 V STPS20H100CT 20A/100V O/P: (1)Full Load Turn on (2) 62.8 V (3) 67.6 V (2)Output Short P (3)Fulll load continue Ta:25℃ 3 Input Capacitor Voltage C5 Rated: I/P:High-Line +3V = 308 V (1) 425.81 V 33u/450V 105℃ 16*20 KXJ O/P: (1)Full Load Turn on /Off (2) 421.87 V (2) Min load Turn on /Off (3) 422.88 V P (3)Full Load /Min load Change Ta:25℃ 4 Control IC Voltage Test U 1 Rated: I/P:High-Line +3V = 308 V (1) 22.245 V PFC FAN6921MR 17V~30V O/P: (1)Full Load Turn on /Off (2) 22.209 V (2) Min load Turn on /Off (3) 22.224 V P (3)Full Load /Min load Change Ta:25℃ 5 Power Transistor Q1 Rated: I/P:High-Line +3V = 308 V (1) 484 V ( D to S) or (C to E) Peak Voltage NDF10N60ZG 10A/600V O/P: (1)Full Load Turn on (2) 444 V (3) 452 V (2) Output Short P (3)Fulll load continue Ta:25℃ Model: LPF-40D-15 Test Report 5 / 8 LPF-40D series SAFETY & E.M.C. TEST SAFETY TEST NO 1 TEST ITEM SPECIFICATION TEST CONDITION RESULT WITHSTAND VOLTAGE I/P-O/P: 3.75 KVAC/min I/P-O/P: 4 I/P-O/P: KVAC/min VERDICT 2.515 mA P NO DAMAGE Ta:25℃ 2 ISOLATION RESISTANCE I/P-O/P:500VDC>100MΩ I/P-O/P: 500 VDC I/P-O/P: 8.47 GΩ Ta:25℃/70%RH p NO DAMAGE 3 APPROVAL TUV: Certificate NO : N/A UL: File NO : E.M.C TEST NO 1 TEST ITEM SPECIFICATION TEST CONDITION RESULT HARMONIC EN61000-3-2 I/P:230VAC/240VAC/220VAC50HZ PASS CLASS C O/P:100%,75%,60%LOAD CLASS C ≧60% VERDICT P Ta:25℃ 2 3 4 5 CONDUCTION RADIATION E.S.D E.F.T EN55022 I/P: 230 VAC (50HZ)/115V[60HZ] PASS CLASS B O/P:FULL/60% LOAD Ta:25℃ Test by certified Lab EN55022 I/P: 230 VAC (50HZ)/115V[60HZ] PASS CLASS B O/P:FULL LOAD Ta:25℃ Test by certified Lab AIR:8KV / Contact:6KV I/P: 230 VAC/50HZ CRITERIA A INDUSTRY O/P:FULL LOAD Ta:25℃ EN61000-4-4 I/P: 230 VAC/50HZ INDUSTRY O/P:FULL LOAD Ta:25℃ INPUT: 2KV 6 SURGE IEC61000-4-5 I/P: 230 VAC/50HZ INDUSTRY O/P:FULL LOAD Ta:25℃ L-N :2KV 7 P P P CRITERIA A P CRITERIA A P Test by certified Lab & Test Report Prepare Model: LPF-40D-15 Test Report 6 / 8 LPF-40D series RELIABILITY TEST ENVIRONMENT TEST NO 1 TEST ITEM SPECIFICATION TEMPERATURE RISE TEST MODEL:LPF-40-12 TEST CONDITION RESULT VERDICT 1. ROOM AMBIENT BURN-IN:2.5 HRS I/P: 230VAC O/P: 95% LOAD Ta=29 ℃ 2. HIGH AMBIENT BURN-IN:3.5 HRS I/P: 230VAC O/P: 95% LOAD Ta=50.4 ℃ 2 LOW TEMPERATURE ROOM AMBIENT HIGH AMBIENT Ta=29 ℃ Ta= 50.4 ℃ NO Position P/N 1 C11 474/450V 10% P=10 MEX 45.3 63.4 2 L3 TF2221 46.3 64.3 3 BD1 SILICON UR4KB80 43.8 62.0 4 L1 44.9 62.9 5 Q1 48.8 66.8 6 D2 59.3 77.4 7 Q3 57.6 75.5 8 C16 TR991 NDF10N60ZG 10A/600V TO220F 2A/800V GP20K T-52mm STP9NK70ZFP 7.5A/700V TO220F 22u/50V UL10Kh 5*11 YXM 53.6 71.1 9 U1 FAN6921MR SOP 56.7 74.8 10 C201 55.4 72.8 11 RTH2 50.5 68.3 4A/800V 12 C5 47u/50V UL10Kh 6.3*11 YXM NTC 100KΩ 3Φ TTC3A104F4193EY 1% 33u/450V 105 16*20 KXJ 50.6 68.2 13 C105 820u/25V UL10Kh 10*20 ZLH 57.2 74.9 14 D101 PFR30L60CT 30A/60V TO220 59.4 77.1 15 C111 330u/25V UL8Kh 8*11.5 ZLH 54.2 72.0 16 LF100 TR895-R2 53.8 71.9 17 D3 2A/800V GP20K T-52mm 50.1 67.9 18 LF1 TR732A-R1 35.7 54.5 19 T1 TF2203 58.2 75.2 TURN ON AFTER 2 HOUR I/P: 305VAC/100VAC P TEST:OK O/P: 95 ﹪LOAD TURN ON TEST P Ta= -40 ℃ 3 4 HIGH HUMIDITY AFTER 12 HOURS I/P: 305 VAC HIGH TEMPERATURE O/P:95 LOAD HIGH VOLTAGE IN CHAMBER ON CONTROL 50 ℃ TURN ON TEST NO DAMAGE HUMIDITY= TEMPERATURE + 0.03 %(0~50℃) STORAGE TEMPERATURE TEST P Ta= 50 ℃ 95 %R.H I/P: 230 VAC + 0 %(0~50℃) O/P:95 LOAD COEFFICIENT 5 TEST:OK 1. Thermal shock Temperature: -45℃~ +90℃ P OK 2. Temperature change rate :25℃ / MIN 3. Dwell time low and high temperature : 30 MIN/EACH P 4. Total test cycle:5 CYCLE 5. Input/Output condition: STATIC Model: LPF-40D-15 Test Report 7 / 8 LPF-40D series 6 THERMAL SHOCK TEST OK 1. Thermal shock Temperature: -35℃~ +55℃ 2. Temperature change rate :25℃ / MIN 3. Dwell time low and high temperature : 30 MIN/EACH P 4. Total test cycle:10 CYCLE 5. Input/Output condition: 230VAC/Full Load AC ON/OFF TEST turn on 58sec;turn off 2sec 7 VIBRATION TEST TEST:OK 1 Carton & 1 Set (1) Waveform: Sine Wave (2) Frequency:10~500Hz (3) Sweep Time:12min/sweep cycle P (4) Acceleration:5G (5) Test Time:72min in each axis (X.Y.Z) (6) Ta:25℃ 8 CAPACITOR LIFE CYCLE 9 10 (1) 414338 HRS (2) I/P: 230VAC (2) 94640 (3) 124930 HRS O/P:FULL LOAD Ta=50 ℃ LIFE TIME (3) I/P: 230VAC O/P:75% LOAD Ta= 50 ℃ MIL-HDBK-217F NOTICES2 PARTS COUNT TOTAL FAILURE RATE: 438.8 KHRS MTBF DMTBF/Accelerated Life Test DATE LPF-40-12:SUPPOSE C105 IS THE MOST CRITICAL COMPONENT (1) I/P: 230VAC O/P:FULL LOAD Ta=25 ℃ LIFE TIME LIFE TIME P HRS P Demonstration Mean Time Between Failure(Expected Life) : 30,000 hours @ Tcase 80℃; 50,000 hours @ Tcase70℃ P SAMPLE TEST RESULT TESTER APPROVAL 2010/11/11 RD SAMPLE PASS SANFORD SU VINCENT TSENG 2010/11/19 PRODUCT SAMPLE PASS SANFORD SU VINCENT TSENG 2009/08/04 A50-F023 Model: LPF-40D-15 Test Report 8 / 8