Test Report - Datamate Mix-Tek Special Contact Testing

Harwin Test Report Summary
HT02001
General Testing of
Datamate Mix-Tek Special Contacts
HT02001
Test Report for Datamate Mix-Tek General Testing
1. Introduction.
1.1.
Description and Purpose.
The Harwin Datamate (M80 Series) connector is manufactured to the requirements of BS9525F0033. The following tests were carried out to test the performance of the Datamate Mix-Tek
series coaxial and power contacts, known collectively as Special contacts.
1.2. Conclusion.
The following data has been collated from Harwin test report T70-07. The Mix-Tek contacts
met the test requirements set out in section 2.3 of this test report summary all electrical,
mechanical and environmental requirements were fulfilled. These results are representative
of all the Datamate Mix-Tek series coaxial and power contacts. Current vs. temperature rise
information and derate curves are available on request please contact
[email protected].
2. Test Method, Requirements and Results.
2.1. List of Test Samples.
a)
b)
c)
d)
e)
f)
M80-4T110F1-03-301
M80-4C102F1-11-305
M80-5L110M4-03-313
M80-5T102M2-11-311
M80-4T100F1-66-321
M80-5T100M2-66-331
Female Vertical PC Tail with Coax
Female Straight Crimp with Coax
Male Horizontal PC Tail with Coax
Male Vertical PC Tail with Coax
Female Vertical PC Tail with Power
Male Vertical PC Tail with Power
2.2. Testing Methods.
Cable contacts were tested with the appropriate conductors crimped in place. PCB connectors
were terminated to test boards, mated, and with a common buss wire across the cable
connectors. Voltage and Current probes were attached to each end of the common buss, to
minimize bulk resistance. Samples were allocated to the following test groups:
Sample Preparation
Group 1
Group 2
LLCR
LLCR
Mech.
Shock
Group 4
Group 5
Group 6
IR
LLCR
LLCR
LLCR
Thermal
Shock
DWV
Bump
Test
Temp.
Life
Salt
Spray
LLCR
LLCR
Thermal
Shock
LLCR
LLCR
LLCR
Sine
Vibration
Cyclic
Humidity
LLCR
LLCR
Every
Week
Group 3
Group 7
Group 8
Group 9
Impedance
LLCR
CCC
VSWR
Accel'n
LLCR
IR
DWV
Cyclic
Humidity
IR
Key:
LLCR = Low-Level Contact Resistance
DWV = Dielectric Withstanding Voltage
IR = Insulation Resistance
VSWR = Voltage Standing Wave Ratio
CCC = Current Carrying Capacity
DWV
Harwin North America
T: +1 603 893 5376 F: +1 603 893 5396
E: [email protected] W: www.harwin.com
Issue: 1 Date: 21/11/2011 C/Note: -----
Harwin Europe
T: +44 (0) 23 9231 4545 F: +44 (0) 23 9231 4590
Harwin Asia
T: +65 6 779 4909 F: +65 6 779 386
E: [email protected] W: www.harwin.com
E: [email protected] W: www.harwinasia.com
Page 2 of 10
HT02001
Test Report for Datamate Mix-Tek General Testing
Group 7
Group 6
Group 5
Group 4
Group 3
Group 2
Group 1
Mated test samples remained with each other throughout the test group/sequences for which
they were designated. Individual samples were allocated in the following groups:
Part Number
M80-4T110F1-03-301
M80-5L110M4-03-313
M80-4C102F1-11-305
M80-5T102M2-11-311
M80-4T100F1-66-321
M80-5T100M2-66-331
M80-4C100F1-66-327
M80-5T100M2-66-331
M80-4T110F1-03-301
M80-5L110M4-03-313
M80-4C102F1-11-305
M80-5T102M2-11-311
M80-4T100F1-66-321
M80-5T100M2-66-331
M80-4C100F1-66-327
M80-5T100M2-66-331
M80-4T110F1-03-301
M80-5L110M4-03-313
M80-4C102F1-11-305
M80-5T102M2-11-311
M80-4T110F1-03-301
M80-5L110M4-03-313
M80-4C102F1-11-305
M80-5T102M2-11-311
M80-4T100F1-66-321
M80-5T100M2-66-331
M80-4C100F1-66-327
M80-5T100M2-66-331
M80-4T110F1-03-301
M80-5L110M4-03-313
M80-4C102F1-11-305
MBO-5T102M2-11-311
M80-4T100F1-66-321
M80-5T100M2-66-331
M80-4C100F1-66-327
M80-5T100M2-66-331
M80-4T110F1-03-301
M80-5L110M4-03-313
M80-4C102F1-11-305
M80-5T102M2-11-311
M80-4T100F1-66-321
M80-5T100M2-66-331
M80-4C100F1-66-327
M80-5T100M2-66-331
M80-4T110F1-03-301
M80-5L110M4-03-313
M80-4C102F1-11-305
M80-5T102M2-11-311
Harwin North America
T: +1 603 893 5376 F: +1 603 893 5396
E: [email protected] W: www.harwin.com
Issue: 1 Date: 21/11/2011 C/Note: -----
Receptacle
Plug
Receptacle
Plug
Receptacle
Plug
Receptacle
Plug
Receptacle
Plug
Receptacle
Plug
Receptacle
Plug
Receptacle
Plug
Receptacle
Plug
Receptacle
Plug
Receptacle
Plug
Receptacle
Plug
Receptacle
Plug
Receptacle
Plug
Receptacle
Plug
Receptacle
Plug
Receptacle
Plug
Receptacle
Plug
Receptacle
Plug
Receptacle
Plug
Receptacle
Plug
Receptacle
Plug
Receptacle
Plug
Receptacle
Plug
Description
vertical
horizontal
vertical
vertical
vertical
horizontal
vertical
horizontal
vertical
horizontal
vertical
vertical
vertical
horizontal
vertical
horizontal
vertical
horizontal
vertical
vertical
vertical
horizontal
vertical
vertical
vertical
horizontal
vertical
horizontal
vertical
horizontal
vertical
vertical
vertical
horizontal
vertical
horizontal
vertical
horizontal
vertical
vertical
vertical
horizontal
vertical
vertical
vertical
horizontal
vertical
horizontal
Group allocation
PC-Tail
PC-Tail
crimp
PC-Tail
PC-Tail
PC-Tail
solder
PC-Tail
PC-Tail
PC-Tail
crimp
PC-Tail
PC-Tail
PC-Tail
solder
PC-Tail
PC-Tail
PC-Tail
crimp
PC-Tail
PC-Tail
PC-Tail
crimp
PC-Tail
PC-Tail
PC-Tail
solder
PC-Tail
PC-Tail
PC-Tail
crimp
PC-Tail
PC-Tail
PC-Tail
solder
PC-Tail
PC-Tail
PC-Tail
crimp
PC-Tail
PC-Tail
PC-Tail
crimp
PC-Tail
PC-Tail
PC-Tail
solder
PC-Tail
1-1
thru
1-4
1-5
thru
1-8
1-9
thru
1-12
1-13
thru
1-16
2-1
thru
2-4
2-5
thru
2-8
2-9
thru
2-12
2-13
thru
2-16
3-1
thru
3-4
3-5
thru
3-8
4-1
thru
4-4
4-5
thru
4-8
4-9
thru
4-12
4-13
thru
4-16
5-1
thru
5-4
5-5
thru
5-8
5-9
thru
5-12
5-13
thru
5-16
6-1
thru
6-4
6-5
thru
6-8
6-9
thru
6-12
6-13
thru
6-16
7-1
thru
7-4
7-5
thru
7-8
Harwin Europe
T: +44 (0) 23 9231 4545 F: +44 (0) 23 9231 4590
Harwin Asia
T: +65 6 779 4909 F: +65 6 779 386
E: [email protected] W: www.harwin.com
E: [email protected] W: www.harwinasia.com
Page 3 of 10
HT02001
Test Report for Datamate Mix-Tek General Testing
Group 9
Group 8
Sample group allocation continued:
Part Number
M80-4T110F1-03-301
M80-5L110M4-03-313
M80-4C102F1-11-305
M80-5T102M2-11-311
M80-4T100F1-66-321
M80-5T100M2-66-331
M80-4C100F1-66-327
M80-5T100M2-66-331
M80-4T100F1-66-321
M80-5T100M2-66-331
M80-4C100F1-66-327
M80-5T100M2-66-331
Receptacle
Plug
Receptacle
Plug
Receptacle
Plug
Receptacle
Plug
Receptacle
Plug
Receptacle
Plug
Description
vertical
horizontal
vertical
vertical
vertical
horizontal
vertical
horizontal
vertical
horizontal
vertical
vertical
Group allocation
PC-Tail
PC-Tail
crimp
PC-Tail
PC-Tail
PC-Tail
solder
PC-Tail
PC-Tail
PC-Tail
crimp
PC-Tail
8-1
thru
8-4
8-5
thru
8-8
8-9
thru
8-12
8-13
thru
8-16
9-1
9-2
2.3. Test Requirements and Results.
a)
Group 1 Shock, Vibration
Test
Low-Level Contact Resistance
M80-301/M80-313 Inner Contact
M80-301/M80-313 Outer Contact
M80-305/M80-311 Inner Contact
M80-305/M80-311 Outer Contact
M80-321/M80-331
M80-327/M80-331
Mechanical Shock
M80-301/M80-313
M80-305/M80-311
M80-321/M80-331
M80-327/M80-331
Low-Level Contact Resistance
M80-301/M80-313 Inner Contact
M80-301/M80-313 Outer Contact
M80-305/M80-311 Inner Contact
M80-305/M80-311 Outer Contact
M80-321/M80-331
M80-327/M80-331
Sine Vibration
M80-301/M80-313
M80-305/M80-311
M80-321/M80-331
M80-327/M80-331
Low-Level Contact Resistance
M80-301/M80-313 Inner Contact
M80-301/M80-313 Outer Contact
M80-305/M80-311 Inner Contact
M80-305/M80-311 Outer Contact
M80-321/M80-331
M80-327/M80-331
Harwin North America
T: +1 603 893 5376 F: +1 603 893 5396
E: [email protected] W: www.harwin.com
Issue: 1 Date: 21/11/2011 C/Note: -----
Requirement
Result
6.0
Max.
6.0 m Max.
5.9
Max.
1.9 m Max.
5.6 m Max.
Max.
0.8 m Max.
4.9 m Max.
No Damage
No Damage
No Damage
No Damage
Passed
Passed
Passed
Passed
6.0 m
6.0 m
6.0 m
6.0 m
6.0 m
6.0 m
Max.
Max.
Max.
Max.
Max.
Max.
No Damage
No Damage
No Damage
No Damage
6.0 m
6.0 m
6.0 m
6.0 m
6.0 m
6.0 m
Max.
Max.
Max.
Max.
Max.
Max.
5.8 m
1.9 m
4.9 m
4.0 m
0.9 m
5.0 m
Max.
Max.
Max.
Max.
Max.
Max.
Passed
Passed
Passed
Passed
5.6 m
1.8 m
5.6 m
4.3 m
0.8 m
5.2 m
Max.
Max.
Max.
Max.
Max.
Max.
Harwin Europe
T: +44 (0) 23 9231 4545 F: +44 (0) 23 9231 4590
Harwin Asia
T: +65 6 779 4909 F: +65 6 779 386
E: [email protected] W: www.harwin.com
E: [email protected] W: www.harwinasia.com
Page 4 of 10
HT02001
Test Report for Datamate Mix-Tek General Testing
b)
Group 2 Thermal Shock, Humidity
Test
Low-Level Contact Resistance
M80-301/M80-313 Inner Contact
M80-301/M80-313 Outer Contact
M80-305/M80-311 Inner Contact
M80-305/M80-311 Outer Contact
M80-321/M80-331
M80-327/M80-331
Thermal Shock
M80-301/M80-313
M80-305/M80-311
M80-321/M80-331
M80-327/M80-331
Low-Level Contact Resistance
M80-301/M80-313 Inner Contact
M80-301/M80-313 Outer Contact
M80-305/M80-311 Inner Contact
M80-305/M80-311 Outer Contact
M80-321/M80-331
M80-327/M80-331
Cyclic Humidity
M80-301/M80-313
M80-305/M80-311
M80-321/M80-331
M80-327/M80-331
Low-Level Contact Resistance
M80-301/M80-313 Inner Contact
M80-301/M80-313 Outer Contact
M80-305/M80-311 Inner Contact
M80-305/M80-311 Outer Contact
M80-321/M80-331
M80-327/M80-331
Low-Level Contact Resistance @ 336 hours
M80-301/M80-313 Inner Contact
M80-301/M80-313 Outer Contact
M80-305/M80-311 Inner Contact
M80-305/M80-311 Outer Contact
M80-321/M80-331
M80-327/M80-331
Low-Level Contact Resistance @ 504 hours
M80-301/M80-313 Inner Contact
M80-301/M80-313 Outer Contact
M80-305/M80-311 Inner Contact
M80-305/M80-311 Outer Contact
M80-321/M80-331
M80-327/M80-331
Low-Level Contact Resistance @ 672 hours
M80-301/M80-313 Inner Contact
M80-301/M80-313 Outer Contact
M80-305/M80-311 Inner Contact
M80-305/M80-311 Outer Contact
M80-321/M80-331
M80-327/M80-331
Requirement
6.0
Max.
6.0 m Max.
No Damage
No Damage
No Damage
No Damage
6.0 m
6.0 m
6.0 m
6.0 m
6.0 m
6.0 m
Max.
Max.
Max.
Max.
Max.
Max.
No Damage
No Damage
No Damage
No Damage
6.0 m
6.0 m
6.0 m
6.0 m
6.0 m
6.0 m
Max.
Max.
Max.
Max.
Max.
Max.
Result
4.7
1.6 m
5.9 m
2.2
0.9 m
3.3 m
Max.
Max.
Max.
Max.
Max.
Max.
Passed
Passed
Passed
Passed
4.5 m
1.7 m
5.8 m
2.1 m
0.8 m
3.9 m
Max.
Max.
Max.
Max.
Max.
Max.
Passed
Passed
Passed
Passed
5.2 m
1.7 m
5.8 m
2.2 m
0.7 m
4.8 m
Max.
Max.
Max.
Max.
Max.
Max.
6.0
Max.
6.0 m Max.
5.0
Max.
1.7 m Max.
6.0 m Max.
Max.
0.8 m Max.
4.7 m Max.
6.0
Max.
6.0 m Max.
6.0 m
3.9 m
5.9 m
3.2 m
0.7 m
3.9 m
Max.
Max.
Max.
Max.
Max.
Max.
6.0
Max.
6.0 m Max.
4.8 m
2.6 m
5.9 m
2.0 m
0.7 m
4.4 m
Max.
Max.
Max.
Max.
Max.
Max.
Group 2 test requirements and results continued on following page.
Harwin North America
T: +1 603 893 5376 F: +1 603 893 5396
E: [email protected] W: www.harwin.com
Issue: 1 Date: 21/11/2011 C/Note: -----
Harwin Europe
T: +44 (0) 23 9231 4545 F: +44 (0) 23 9231 4590
Harwin Asia
T: +65 6 779 4909 F: +65 6 779 386
E: [email protected] W: www.harwin.com
E: [email protected] W: www.harwinasia.com
Page 5 of 10
HT02001
Test Report for Datamate Mix-Tek General Testing
b)
Group 2 Thermal Shock, Humidity (continued)
Test
Low-Level Contact Resistance @ 840 hours
M80-301/M80-313 Inner Contact
M80-301/M80-313 Outer Contact
M80-305/M80-311 Inner Contact
M80-305/M80-311 Outer Contact
M80-321/M80-331
M80-327/M80-331
Low-Level Contact Resistance @ 1008 hours
M80-301/M80-313 Inner Contact
M80-301/M80-313 Outer Contact
M80-305/M80-311 Inner Contact
M80-305/M80-311 Outer Contact
M80-321/M80-331
M80-327/M80-331
Low-Level Contact Resistance @ 1176 hours
M80-301/M80-313 Inner Contact
M80-301/M80-313 Outer Contact
M80-305/M80-311 Inner Contact
M80-305/M80-311 Outer Contact
M80-321/M80-331
M80-327/M80-331
Low-Level Contact Resistance @ 1344 hours
M80-301/M80-313 Inner Contact
M80-301/M80-313 Outer Contact
M80-305/M80-311 Inner Contact
M80-305/M80-311 Outer Contact
M80-321/M80-331
M80-327/M80-331
Harwin North America
T: +1 603 893 5376 F: +1 603 893 5396
E: [email protected] W: www.harwin.com
Issue: 1 Date: 21/11/2011 C/Note: -----
Requirement
6.0 m
6.0 m
6.0 m
6.0 m
6.0 m
6.0 m
Max.
Max.
Max.
Max.
Max.
Max.
6.0
Max.
6.0 m Max.
Result
6.0 m
1.9 m
6.0 m
2.5 m
0.8 m
6.0 m
Max.
Max.
Max.
Max.
Max.
Max.
5.2
Max.
1.7 m Max.
5.9 m Max.
Max.
0.7 m Max.
5.3 m Max.
6.0
Max.
6.0 m Max.
Max.
1.8 m Max.
6.0 m Max.
Max.
0.7 m Max.
5.4 m Max.
6.0
Max.
6.0 m Max.
5.6 m
2.0 m
6.0 m
2.2 m
0.9 m
5.4 m
6.
Max.
Max.
Max.
Max.
Max.
Max.
Harwin Europe
T: +44 (0) 23 9231 4545 F: +44 (0) 23 9231 4590
Harwin Asia
T: +65 6 779 4909 F: +65 6 779 386
E: [email protected] W: www.harwin.com
E: [email protected] W: www.harwinasia.com
Page 6 of 10
HT02001
Test Report for Datamate Mix-Tek General Testing
c)
Group 3 Insulation Resistance, Dielectric Withstanding Voltage, Thermal Shock, Humidity
Test
Insulation Resistance
M80-301/M80-313
M80-305/M80-311
Dielectric Withstanding Voltage
M80-301/M80-313
M80-305/M80-311
Thermal Shock
M80-301/M80-313
M80-305/M80-311
M80-321/M80-331
M80-327/M80-331
Insulation Resistance
M80-301/M80-313
M80-305/M80-311
Dielectric Withstanding Voltage
M80-301/M80-313
M80-305/M80-311
Cyclic Humidity
M80-301/M80-313
M80-305/M80-311
M80-321/M80-331
M80-327/M80-331
Insulation Resistance
M80-301/M80-313
M80-305/M80-311
Dielectric Withstanding Voltage
M80-301/M80-313
M80-305/M80-311
d)
Requirement
Result
>106 Megaohms
>106 Megaohms
Passed
Passed
No breakdown, Arc, ect.
No breakdown, Arc, ect.
Passed
Passed
No Damage
No Damage
No Damage
No Damage
Passed
Passed
Passed
Passed
>106 Megaohms
>106 Megaohms
Passed
Passed
No breakdown, Arc, ect.
No breakdown, Arc, ect.
Passed
Passed
No Damage
No Damage
No Damage
No Damage
Passed
Passed
Passed
Passed
>106 Megaohms
>106 Megaohms
Passed
Passed
No breakdown, Arc, ect.
No breakdown, Arc, ect.
Passed
Passed
Requirement
Result
Group 4 Bump
Test
Low-Level Contact Resistance
M80-301/M80-313 Inner Contact
M80-301/M80-313 Outer Contact
M80-305/M80-311 Inner Contact
M80-305/M80-311 Outer Contact
M80-321/M80-331
M80-327/M80-331
Bump Test
M80-301/M80-313
M80-305/M80-311
M80-321/M80-331
M80-327/M80-331
Low-Level Contact Resistance
M80-301/M80-313 Inner Contact
M80-301/M80-313 Outer Contact
M80-305/M80-311 Inner Contact
M80-305/M80-311 Outer Contact
M80-321/M80-331
M80-327/M80-331
Harwin North America
T: +1 603 893 5376 F: +1 603 893 5396
E: [email protected] W: www.harwin.com
Issue: 1 Date: 21/11/2011 C/Note: -----
6.0 m
6.0
Max.
6.0 m Max.
No Damage
No Damage
No Damage
No Damage
6.0 m
6.0 m
6.0 m
6.0 m
6.0 m
6.0 m
Max.
Max.
Max.
Max.
Max.
Max.
5.5 m
1.8 m
5.1 m
4.9 m
0.7 m
5.9 m
Max.
Max.
Max.
Max.
Max.
Max.
Passed
Passed
Passed
Passed
5.5 m
2.3 m
5.8 m
5.0 m
0.9 m
6.0 m
Max.
Max.
Max.
Max.
Max.
Max.
Harwin Europe
T: +44 (0) 23 9231 4545 F: +44 (0) 23 9231 4590
Harwin Asia
T: +65 6 779 4909 F: +65 6 779 386
E: [email protected] W: www.harwin.com
E: [email protected] W: www.harwinasia.com
Page 7 of 10
HT02001
Test Report for Datamate Mix-Tek General Testing
e)
Group 5 Temperature Life
Test
Low-Level Contact Resistance
M80-301/M80-313 Inner Contact
M80-301/M80-313 Outer Contact
M80-305/M80-311 Inner Contact
M80-305/M80-311 Outer Contact
M80-321/M80-331
M80-327/M80-331
Temperature Life
M80-301/M80-313
M80-305/M80-311
M80-321/M80-331
M80-327/M80-331
Low-Level Contact Resistance
M80-301/M80-313 Inner Contact
M80-301/M80-313 Outer Contact
M80-305/M80-311 Inner Contact
M80-305/M80-311 Outer Contact
M80-321/M80-331
M80-327/M80-331
f)
Requirement
Result
6.0
Max.
6.0 m Max.
5.7
Max.
2.0 m Max.
5.6 m Max.
Max.
0.7 m Max.
5.9 m Max.
No Damage
No Damage
No Damage
No Damage
Passed
Passed
Passed
Passed
6.0 m
6.0 m
6.0 m
6.0 m
6.0 m
6.0 m
Max.
Max.
Max.
Max.
Max.
Max.
5.9 m
1.6 m
5.4 m
5.2 m
1.0 m
5.3 m
Max.
Max.
Max.
Max.
Max.
Max.
Group 6 Salt Spray
Test
Low-Level Contact Resistance
M80-301/M80-313 Inner Contact
M80-301/M80-313 Outer Contact
M80-305/M80-311 Inner Contact
M80-305/M80-311 Outer Contact
M80-321/M80-331
M80-327/M80-331
Salt Spray
M80-301/M80-313
M80-305/M80-311
M80-321/M80-331
M80-327/M80-331
Low-Level Contact Resistance
M80-301/M80-313 Inner Contact
M80-301/M80-313 Outer Contact
M80-305/M80-311 Inner Contact
M80-305/M80-311 Outer Contact
M80-321/M80-331
M80-327/M80-331
Harwin North America
T: +1 603 893 5376 F: +1 603 893 5396
E: [email protected] W: www.harwin.com
Issue: 1 Date: 21/11/2011 C/Note: -----
Requirement
Result
6.0
Max.
6.0 m Max.
5.8
Max.
5.0 m Max.
5.9 m Max.
Max.
0.8 m Max.
5.1 m Max.
No Damage
No Damage
No Damage
No Damage
Passed
Passed
Passed
Passed
6.0 m
6.0 m
6.0 m
6.0 m
6.0 m
6.0 m
Max.
Max.
Max.
Max.
Max.
Max.
6.0 m
1.8 m
5.9 m
5.8 m
0.9 m
5.9 m
Max.
Max.
Max.
Max.
Max.
Max.
Harwin Europe
T: +44 (0) 23 9231 4545 F: +44 (0) 23 9231 4590
Harwin Asia
T: +65 6 779 4909 F: +65 6 779 386
E: [email protected] W: www.harwin.com
E: [email protected] W: www.harwinasia.com
Page 8 of 10
HT02001
Test Report for Datamate Mix-Tek General Testing
g)
Group 7 Impedance, Voltage Standing Wave Ratio (VSWR)
Test
Impedance
M80-301/M80-313 @ 1.0 GHz
M80-301/M80-313 @ 3.0 GHz
M80-301/M80-313 @ 6.0 GHz
M80-305/M80-311 @ 1.0 GHz
M80-305/M80-311 @ 3.0 GHz
M80-305/M80-311 @ 6.0 GHz
Voltage Standing Wave Ratio
M80-301/M80-313 @ 1.0 GHz
M80-301/M80-313 @ 3.0 GHz
M80-301/M80-313 @ 6.0 GHz
M80-305/M80-311 @ 1.0 GHz
M80-305/M80-311 @ 3.0 GHz
M80-305/M80-311 @ 6.0 GHz
h)
Requirement
Record
Record
Record
Record
Record
Record
Result
70.6
75.6
91.8
85.0
ax.
Record
Record
Record
Record
Record
Record
1.18 Max.
1.43 Max.
1.62 Max.
1.30 Max.
1.96 Max.
1.94 Max.
Requirement
Result
6.0
Max.
6.0 m Max.
6.0
Max.
2.0 m Max.
5.0 m Max.
Max.
0.8 m Max.
5.1 m Max.
No Damage
No Damage
No Damage
No Damage
Passed
Passed
Passed
Passed
Group 8 Acceleration
Test
Low-Level Contact Resistance
M80-301/M80-313 Inner Contact
M80-301/M80-313 Outer Contact
M80-305/M80-311 Inner Contact
M80-305/M80-311 Outer Contact
M80-321/M80-331
M80-327/M80-331
Acceleration
M80-301/M80-313
M80-305/M80-311
M80-321/M80-331
M80-327/M80-331
Low-Level Contact Resistance
M80-301/M80-313 Inner Contact
M80-301/M80-313 Outer Contact
M80-305/M80-311 Inner Contact
M80-305/M80-311 Outer Contact
M80-321/M80-331
M80-327/M80-331
Harwin North America
T: +1 603 893 5376 F: +1 603 893 5396
E: [email protected] W: www.harwin.com
Issue: 1 Date: 21/11/2011 C/Note: -----
6.0 m
6.0 m
6.0 m
6.0 m
6.0 m
6.0 m
Max.
Max.
Max.
Max.
Max.
Max.
5.4 m
1.7 m
5.5 m
5.8 m
0.7 m
5.0 m
Max.
Max.
Max.
Max.
Max.
Max.
Harwin Europe
T: +44 (0) 23 9231 4545 F: +44 (0) 23 9231 4590
Harwin Asia
T: +65 6 779 4909 F: +65 6 779 386
E: [email protected] W: www.harwin.com
E: [email protected] W: www.harwinasia.com
Page 9 of 10
HT02001
Test Report for Datamate Mix-Tek General Testing
i)
Group 9 Current
Test
M80-327/M80-331 No. of contacts
1 Contact
2 Contacts
3 Contacts
4 Contacts
5 Contacts
6 Contacts
7 Contacts
8 Contacts
9 Contacts
10 Contacts
11 Contacts
12 Contacts
M80-321/M80-331 No. of contacts
1 Contact
2 Contacts
3 Contacts
4 Contacts
5 Contacts
6 Contacts
7 Contacts
8 Contacts
9 Contacts
10 Contacts
11 Contacts
12 Contacts
Harwin North America
T: +1 603 893 5376 F: +1 603 893 5396
E: [email protected] W: www.harwin.com
Issue: 1 Date: 21/11/2011 C/Note: -----
Requirement
Result
20A or +30°C
20A or +30°C
20A or +30°C
20A or +30°C
20A or +30°C
20A or +30°C
20A or +30°C
20A or +30°C
20A or +30°C
20A or +30°C
20A or +30°C
20A or +30°C
25 amps / +24.7°C
20 amps / +29.6°C
20 amps / +40.8°C
20 amps / +32.1°C
20 amps / +31.3°C
20 amps / +35.1°C
20 amps / +50.2°C
20 amps / +49.1°C
20 amps / +62.2°C
20 amps / +71.5°C
20 amps / +79.5°C
20 amps / +87.3°C
20A or +30°C
20A or +30°C
20A or +30°C
20A or +30°C
20A or +30°C
20A or +30°C
20A or +30°C
20A or +30°C
20A or +30°C
20A or +30°C
20A or +30°C
20A or +30°C
25 amps / +39.0°C
20 amps / +29.7°C
20 amps / +34.6°C
20 amps / +53.4°C
20 amps / +59.2°C
20 amps / +66.6°C
20 amps / +67.5°C
20 amps / +80.7°C
20 amps / +72.1°C
20 amps / +93.7°C
20 amps / +100.6°C
20 amps / +104.1°C
Harwin Europe
T: +44 (0) 23 9231 4545 F: +44 (0) 23 9231 4590
Harwin Asia
T: +65 6 779 4909 F: +65 6 779 386
E: [email protected] W: www.harwin.com
E: [email protected] W: www.harwinasia.com