Harwin Test Report Summary HT02001 General Testing of Datamate Mix-Tek Special Contacts HT02001 Test Report for Datamate Mix-Tek General Testing 1. Introduction. 1.1. Description and Purpose. The Harwin Datamate (M80 Series) connector is manufactured to the requirements of BS9525F0033. The following tests were carried out to test the performance of the Datamate Mix-Tek series coaxial and power contacts, known collectively as Special contacts. 1.2. Conclusion. The following data has been collated from Harwin test report T70-07. The Mix-Tek contacts met the test requirements set out in section 2.3 of this test report summary all electrical, mechanical and environmental requirements were fulfilled. These results are representative of all the Datamate Mix-Tek series coaxial and power contacts. Current vs. temperature rise information and derate curves are available on request please contact [email protected]. 2. Test Method, Requirements and Results. 2.1. List of Test Samples. a) b) c) d) e) f) M80-4T110F1-03-301 M80-4C102F1-11-305 M80-5L110M4-03-313 M80-5T102M2-11-311 M80-4T100F1-66-321 M80-5T100M2-66-331 Female Vertical PC Tail with Coax Female Straight Crimp with Coax Male Horizontal PC Tail with Coax Male Vertical PC Tail with Coax Female Vertical PC Tail with Power Male Vertical PC Tail with Power 2.2. Testing Methods. Cable contacts were tested with the appropriate conductors crimped in place. PCB connectors were terminated to test boards, mated, and with a common buss wire across the cable connectors. Voltage and Current probes were attached to each end of the common buss, to minimize bulk resistance. Samples were allocated to the following test groups: Sample Preparation Group 1 Group 2 LLCR LLCR Mech. Shock Group 4 Group 5 Group 6 IR LLCR LLCR LLCR Thermal Shock DWV Bump Test Temp. Life Salt Spray LLCR LLCR Thermal Shock LLCR LLCR LLCR Sine Vibration Cyclic Humidity LLCR LLCR Every Week Group 3 Group 7 Group 8 Group 9 Impedance LLCR CCC VSWR Accel'n LLCR IR DWV Cyclic Humidity IR Key: LLCR = Low-Level Contact Resistance DWV = Dielectric Withstanding Voltage IR = Insulation Resistance VSWR = Voltage Standing Wave Ratio CCC = Current Carrying Capacity DWV Harwin North America T: +1 603 893 5376 F: +1 603 893 5396 E: [email protected] W: www.harwin.com Issue: 1 Date: 21/11/2011 C/Note: ----- Harwin Europe T: +44 (0) 23 9231 4545 F: +44 (0) 23 9231 4590 Harwin Asia T: +65 6 779 4909 F: +65 6 779 386 E: [email protected] W: www.harwin.com E: [email protected] W: www.harwinasia.com Page 2 of 10 HT02001 Test Report for Datamate Mix-Tek General Testing Group 7 Group 6 Group 5 Group 4 Group 3 Group 2 Group 1 Mated test samples remained with each other throughout the test group/sequences for which they were designated. Individual samples were allocated in the following groups: Part Number M80-4T110F1-03-301 M80-5L110M4-03-313 M80-4C102F1-11-305 M80-5T102M2-11-311 M80-4T100F1-66-321 M80-5T100M2-66-331 M80-4C100F1-66-327 M80-5T100M2-66-331 M80-4T110F1-03-301 M80-5L110M4-03-313 M80-4C102F1-11-305 M80-5T102M2-11-311 M80-4T100F1-66-321 M80-5T100M2-66-331 M80-4C100F1-66-327 M80-5T100M2-66-331 M80-4T110F1-03-301 M80-5L110M4-03-313 M80-4C102F1-11-305 M80-5T102M2-11-311 M80-4T110F1-03-301 M80-5L110M4-03-313 M80-4C102F1-11-305 M80-5T102M2-11-311 M80-4T100F1-66-321 M80-5T100M2-66-331 M80-4C100F1-66-327 M80-5T100M2-66-331 M80-4T110F1-03-301 M80-5L110M4-03-313 M80-4C102F1-11-305 MBO-5T102M2-11-311 M80-4T100F1-66-321 M80-5T100M2-66-331 M80-4C100F1-66-327 M80-5T100M2-66-331 M80-4T110F1-03-301 M80-5L110M4-03-313 M80-4C102F1-11-305 M80-5T102M2-11-311 M80-4T100F1-66-321 M80-5T100M2-66-331 M80-4C100F1-66-327 M80-5T100M2-66-331 M80-4T110F1-03-301 M80-5L110M4-03-313 M80-4C102F1-11-305 M80-5T102M2-11-311 Harwin North America T: +1 603 893 5376 F: +1 603 893 5396 E: [email protected] W: www.harwin.com Issue: 1 Date: 21/11/2011 C/Note: ----- Receptacle Plug Receptacle Plug Receptacle Plug Receptacle Plug Receptacle Plug Receptacle Plug Receptacle Plug Receptacle Plug Receptacle Plug Receptacle Plug Receptacle Plug Receptacle Plug Receptacle Plug Receptacle Plug Receptacle Plug Receptacle Plug Receptacle Plug Receptacle Plug Receptacle Plug Receptacle Plug Receptacle Plug Receptacle Plug Receptacle Plug Receptacle Plug Description vertical horizontal vertical vertical vertical horizontal vertical horizontal vertical horizontal vertical vertical vertical horizontal vertical horizontal vertical horizontal vertical vertical vertical horizontal vertical vertical vertical horizontal vertical horizontal vertical horizontal vertical vertical vertical horizontal vertical horizontal vertical horizontal vertical vertical vertical horizontal vertical vertical vertical horizontal vertical horizontal Group allocation PC-Tail PC-Tail crimp PC-Tail PC-Tail PC-Tail solder PC-Tail PC-Tail PC-Tail crimp PC-Tail PC-Tail PC-Tail solder PC-Tail PC-Tail PC-Tail crimp PC-Tail PC-Tail PC-Tail crimp PC-Tail PC-Tail PC-Tail solder PC-Tail PC-Tail PC-Tail crimp PC-Tail PC-Tail PC-Tail solder PC-Tail PC-Tail PC-Tail crimp PC-Tail PC-Tail PC-Tail crimp PC-Tail PC-Tail PC-Tail solder PC-Tail 1-1 thru 1-4 1-5 thru 1-8 1-9 thru 1-12 1-13 thru 1-16 2-1 thru 2-4 2-5 thru 2-8 2-9 thru 2-12 2-13 thru 2-16 3-1 thru 3-4 3-5 thru 3-8 4-1 thru 4-4 4-5 thru 4-8 4-9 thru 4-12 4-13 thru 4-16 5-1 thru 5-4 5-5 thru 5-8 5-9 thru 5-12 5-13 thru 5-16 6-1 thru 6-4 6-5 thru 6-8 6-9 thru 6-12 6-13 thru 6-16 7-1 thru 7-4 7-5 thru 7-8 Harwin Europe T: +44 (0) 23 9231 4545 F: +44 (0) 23 9231 4590 Harwin Asia T: +65 6 779 4909 F: +65 6 779 386 E: [email protected] W: www.harwin.com E: [email protected] W: www.harwinasia.com Page 3 of 10 HT02001 Test Report for Datamate Mix-Tek General Testing Group 9 Group 8 Sample group allocation continued: Part Number M80-4T110F1-03-301 M80-5L110M4-03-313 M80-4C102F1-11-305 M80-5T102M2-11-311 M80-4T100F1-66-321 M80-5T100M2-66-331 M80-4C100F1-66-327 M80-5T100M2-66-331 M80-4T100F1-66-321 M80-5T100M2-66-331 M80-4C100F1-66-327 M80-5T100M2-66-331 Receptacle Plug Receptacle Plug Receptacle Plug Receptacle Plug Receptacle Plug Receptacle Plug Description vertical horizontal vertical vertical vertical horizontal vertical horizontal vertical horizontal vertical vertical Group allocation PC-Tail PC-Tail crimp PC-Tail PC-Tail PC-Tail solder PC-Tail PC-Tail PC-Tail crimp PC-Tail 8-1 thru 8-4 8-5 thru 8-8 8-9 thru 8-12 8-13 thru 8-16 9-1 9-2 2.3. Test Requirements and Results. a) Group 1 Shock, Vibration Test Low-Level Contact Resistance M80-301/M80-313 Inner Contact M80-301/M80-313 Outer Contact M80-305/M80-311 Inner Contact M80-305/M80-311 Outer Contact M80-321/M80-331 M80-327/M80-331 Mechanical Shock M80-301/M80-313 M80-305/M80-311 M80-321/M80-331 M80-327/M80-331 Low-Level Contact Resistance M80-301/M80-313 Inner Contact M80-301/M80-313 Outer Contact M80-305/M80-311 Inner Contact M80-305/M80-311 Outer Contact M80-321/M80-331 M80-327/M80-331 Sine Vibration M80-301/M80-313 M80-305/M80-311 M80-321/M80-331 M80-327/M80-331 Low-Level Contact Resistance M80-301/M80-313 Inner Contact M80-301/M80-313 Outer Contact M80-305/M80-311 Inner Contact M80-305/M80-311 Outer Contact M80-321/M80-331 M80-327/M80-331 Harwin North America T: +1 603 893 5376 F: +1 603 893 5396 E: [email protected] W: www.harwin.com Issue: 1 Date: 21/11/2011 C/Note: ----- Requirement Result 6.0 Max. 6.0 m Max. 5.9 Max. 1.9 m Max. 5.6 m Max. Max. 0.8 m Max. 4.9 m Max. No Damage No Damage No Damage No Damage Passed Passed Passed Passed 6.0 m 6.0 m 6.0 m 6.0 m 6.0 m 6.0 m Max. Max. Max. Max. Max. Max. No Damage No Damage No Damage No Damage 6.0 m 6.0 m 6.0 m 6.0 m 6.0 m 6.0 m Max. Max. Max. Max. Max. Max. 5.8 m 1.9 m 4.9 m 4.0 m 0.9 m 5.0 m Max. Max. Max. Max. Max. Max. Passed Passed Passed Passed 5.6 m 1.8 m 5.6 m 4.3 m 0.8 m 5.2 m Max. Max. Max. Max. Max. Max. Harwin Europe T: +44 (0) 23 9231 4545 F: +44 (0) 23 9231 4590 Harwin Asia T: +65 6 779 4909 F: +65 6 779 386 E: [email protected] W: www.harwin.com E: [email protected] W: www.harwinasia.com Page 4 of 10 HT02001 Test Report for Datamate Mix-Tek General Testing b) Group 2 Thermal Shock, Humidity Test Low-Level Contact Resistance M80-301/M80-313 Inner Contact M80-301/M80-313 Outer Contact M80-305/M80-311 Inner Contact M80-305/M80-311 Outer Contact M80-321/M80-331 M80-327/M80-331 Thermal Shock M80-301/M80-313 M80-305/M80-311 M80-321/M80-331 M80-327/M80-331 Low-Level Contact Resistance M80-301/M80-313 Inner Contact M80-301/M80-313 Outer Contact M80-305/M80-311 Inner Contact M80-305/M80-311 Outer Contact M80-321/M80-331 M80-327/M80-331 Cyclic Humidity M80-301/M80-313 M80-305/M80-311 M80-321/M80-331 M80-327/M80-331 Low-Level Contact Resistance M80-301/M80-313 Inner Contact M80-301/M80-313 Outer Contact M80-305/M80-311 Inner Contact M80-305/M80-311 Outer Contact M80-321/M80-331 M80-327/M80-331 Low-Level Contact Resistance @ 336 hours M80-301/M80-313 Inner Contact M80-301/M80-313 Outer Contact M80-305/M80-311 Inner Contact M80-305/M80-311 Outer Contact M80-321/M80-331 M80-327/M80-331 Low-Level Contact Resistance @ 504 hours M80-301/M80-313 Inner Contact M80-301/M80-313 Outer Contact M80-305/M80-311 Inner Contact M80-305/M80-311 Outer Contact M80-321/M80-331 M80-327/M80-331 Low-Level Contact Resistance @ 672 hours M80-301/M80-313 Inner Contact M80-301/M80-313 Outer Contact M80-305/M80-311 Inner Contact M80-305/M80-311 Outer Contact M80-321/M80-331 M80-327/M80-331 Requirement 6.0 Max. 6.0 m Max. No Damage No Damage No Damage No Damage 6.0 m 6.0 m 6.0 m 6.0 m 6.0 m 6.0 m Max. Max. Max. Max. Max. Max. No Damage No Damage No Damage No Damage 6.0 m 6.0 m 6.0 m 6.0 m 6.0 m 6.0 m Max. Max. Max. Max. Max. Max. Result 4.7 1.6 m 5.9 m 2.2 0.9 m 3.3 m Max. Max. Max. Max. Max. Max. Passed Passed Passed Passed 4.5 m 1.7 m 5.8 m 2.1 m 0.8 m 3.9 m Max. Max. Max. Max. Max. Max. Passed Passed Passed Passed 5.2 m 1.7 m 5.8 m 2.2 m 0.7 m 4.8 m Max. Max. Max. Max. Max. Max. 6.0 Max. 6.0 m Max. 5.0 Max. 1.7 m Max. 6.0 m Max. Max. 0.8 m Max. 4.7 m Max. 6.0 Max. 6.0 m Max. 6.0 m 3.9 m 5.9 m 3.2 m 0.7 m 3.9 m Max. Max. Max. Max. Max. Max. 6.0 Max. 6.0 m Max. 4.8 m 2.6 m 5.9 m 2.0 m 0.7 m 4.4 m Max. Max. Max. Max. Max. Max. Group 2 test requirements and results continued on following page. Harwin North America T: +1 603 893 5376 F: +1 603 893 5396 E: [email protected] W: www.harwin.com Issue: 1 Date: 21/11/2011 C/Note: ----- Harwin Europe T: +44 (0) 23 9231 4545 F: +44 (0) 23 9231 4590 Harwin Asia T: +65 6 779 4909 F: +65 6 779 386 E: [email protected] W: www.harwin.com E: [email protected] W: www.harwinasia.com Page 5 of 10 HT02001 Test Report for Datamate Mix-Tek General Testing b) Group 2 Thermal Shock, Humidity (continued) Test Low-Level Contact Resistance @ 840 hours M80-301/M80-313 Inner Contact M80-301/M80-313 Outer Contact M80-305/M80-311 Inner Contact M80-305/M80-311 Outer Contact M80-321/M80-331 M80-327/M80-331 Low-Level Contact Resistance @ 1008 hours M80-301/M80-313 Inner Contact M80-301/M80-313 Outer Contact M80-305/M80-311 Inner Contact M80-305/M80-311 Outer Contact M80-321/M80-331 M80-327/M80-331 Low-Level Contact Resistance @ 1176 hours M80-301/M80-313 Inner Contact M80-301/M80-313 Outer Contact M80-305/M80-311 Inner Contact M80-305/M80-311 Outer Contact M80-321/M80-331 M80-327/M80-331 Low-Level Contact Resistance @ 1344 hours M80-301/M80-313 Inner Contact M80-301/M80-313 Outer Contact M80-305/M80-311 Inner Contact M80-305/M80-311 Outer Contact M80-321/M80-331 M80-327/M80-331 Harwin North America T: +1 603 893 5376 F: +1 603 893 5396 E: [email protected] W: www.harwin.com Issue: 1 Date: 21/11/2011 C/Note: ----- Requirement 6.0 m 6.0 m 6.0 m 6.0 m 6.0 m 6.0 m Max. Max. Max. Max. Max. Max. 6.0 Max. 6.0 m Max. Result 6.0 m 1.9 m 6.0 m 2.5 m 0.8 m 6.0 m Max. Max. Max. Max. Max. Max. 5.2 Max. 1.7 m Max. 5.9 m Max. Max. 0.7 m Max. 5.3 m Max. 6.0 Max. 6.0 m Max. Max. 1.8 m Max. 6.0 m Max. Max. 0.7 m Max. 5.4 m Max. 6.0 Max. 6.0 m Max. 5.6 m 2.0 m 6.0 m 2.2 m 0.9 m 5.4 m 6. Max. Max. Max. Max. Max. Max. Harwin Europe T: +44 (0) 23 9231 4545 F: +44 (0) 23 9231 4590 Harwin Asia T: +65 6 779 4909 F: +65 6 779 386 E: [email protected] W: www.harwin.com E: [email protected] W: www.harwinasia.com Page 6 of 10 HT02001 Test Report for Datamate Mix-Tek General Testing c) Group 3 Insulation Resistance, Dielectric Withstanding Voltage, Thermal Shock, Humidity Test Insulation Resistance M80-301/M80-313 M80-305/M80-311 Dielectric Withstanding Voltage M80-301/M80-313 M80-305/M80-311 Thermal Shock M80-301/M80-313 M80-305/M80-311 M80-321/M80-331 M80-327/M80-331 Insulation Resistance M80-301/M80-313 M80-305/M80-311 Dielectric Withstanding Voltage M80-301/M80-313 M80-305/M80-311 Cyclic Humidity M80-301/M80-313 M80-305/M80-311 M80-321/M80-331 M80-327/M80-331 Insulation Resistance M80-301/M80-313 M80-305/M80-311 Dielectric Withstanding Voltage M80-301/M80-313 M80-305/M80-311 d) Requirement Result >106 Megaohms >106 Megaohms Passed Passed No breakdown, Arc, ect. No breakdown, Arc, ect. Passed Passed No Damage No Damage No Damage No Damage Passed Passed Passed Passed >106 Megaohms >106 Megaohms Passed Passed No breakdown, Arc, ect. No breakdown, Arc, ect. Passed Passed No Damage No Damage No Damage No Damage Passed Passed Passed Passed >106 Megaohms >106 Megaohms Passed Passed No breakdown, Arc, ect. No breakdown, Arc, ect. Passed Passed Requirement Result Group 4 Bump Test Low-Level Contact Resistance M80-301/M80-313 Inner Contact M80-301/M80-313 Outer Contact M80-305/M80-311 Inner Contact M80-305/M80-311 Outer Contact M80-321/M80-331 M80-327/M80-331 Bump Test M80-301/M80-313 M80-305/M80-311 M80-321/M80-331 M80-327/M80-331 Low-Level Contact Resistance M80-301/M80-313 Inner Contact M80-301/M80-313 Outer Contact M80-305/M80-311 Inner Contact M80-305/M80-311 Outer Contact M80-321/M80-331 M80-327/M80-331 Harwin North America T: +1 603 893 5376 F: +1 603 893 5396 E: [email protected] W: www.harwin.com Issue: 1 Date: 21/11/2011 C/Note: ----- 6.0 m 6.0 Max. 6.0 m Max. No Damage No Damage No Damage No Damage 6.0 m 6.0 m 6.0 m 6.0 m 6.0 m 6.0 m Max. Max. Max. Max. Max. Max. 5.5 m 1.8 m 5.1 m 4.9 m 0.7 m 5.9 m Max. Max. Max. Max. Max. Max. Passed Passed Passed Passed 5.5 m 2.3 m 5.8 m 5.0 m 0.9 m 6.0 m Max. Max. Max. Max. Max. Max. Harwin Europe T: +44 (0) 23 9231 4545 F: +44 (0) 23 9231 4590 Harwin Asia T: +65 6 779 4909 F: +65 6 779 386 E: [email protected] W: www.harwin.com E: [email protected] W: www.harwinasia.com Page 7 of 10 HT02001 Test Report for Datamate Mix-Tek General Testing e) Group 5 Temperature Life Test Low-Level Contact Resistance M80-301/M80-313 Inner Contact M80-301/M80-313 Outer Contact M80-305/M80-311 Inner Contact M80-305/M80-311 Outer Contact M80-321/M80-331 M80-327/M80-331 Temperature Life M80-301/M80-313 M80-305/M80-311 M80-321/M80-331 M80-327/M80-331 Low-Level Contact Resistance M80-301/M80-313 Inner Contact M80-301/M80-313 Outer Contact M80-305/M80-311 Inner Contact M80-305/M80-311 Outer Contact M80-321/M80-331 M80-327/M80-331 f) Requirement Result 6.0 Max. 6.0 m Max. 5.7 Max. 2.0 m Max. 5.6 m Max. Max. 0.7 m Max. 5.9 m Max. No Damage No Damage No Damage No Damage Passed Passed Passed Passed 6.0 m 6.0 m 6.0 m 6.0 m 6.0 m 6.0 m Max. Max. Max. Max. Max. Max. 5.9 m 1.6 m 5.4 m 5.2 m 1.0 m 5.3 m Max. Max. Max. Max. Max. Max. Group 6 Salt Spray Test Low-Level Contact Resistance M80-301/M80-313 Inner Contact M80-301/M80-313 Outer Contact M80-305/M80-311 Inner Contact M80-305/M80-311 Outer Contact M80-321/M80-331 M80-327/M80-331 Salt Spray M80-301/M80-313 M80-305/M80-311 M80-321/M80-331 M80-327/M80-331 Low-Level Contact Resistance M80-301/M80-313 Inner Contact M80-301/M80-313 Outer Contact M80-305/M80-311 Inner Contact M80-305/M80-311 Outer Contact M80-321/M80-331 M80-327/M80-331 Harwin North America T: +1 603 893 5376 F: +1 603 893 5396 E: [email protected] W: www.harwin.com Issue: 1 Date: 21/11/2011 C/Note: ----- Requirement Result 6.0 Max. 6.0 m Max. 5.8 Max. 5.0 m Max. 5.9 m Max. Max. 0.8 m Max. 5.1 m Max. No Damage No Damage No Damage No Damage Passed Passed Passed Passed 6.0 m 6.0 m 6.0 m 6.0 m 6.0 m 6.0 m Max. Max. Max. Max. Max. Max. 6.0 m 1.8 m 5.9 m 5.8 m 0.9 m 5.9 m Max. Max. Max. Max. Max. Max. Harwin Europe T: +44 (0) 23 9231 4545 F: +44 (0) 23 9231 4590 Harwin Asia T: +65 6 779 4909 F: +65 6 779 386 E: [email protected] W: www.harwin.com E: [email protected] W: www.harwinasia.com Page 8 of 10 HT02001 Test Report for Datamate Mix-Tek General Testing g) Group 7 Impedance, Voltage Standing Wave Ratio (VSWR) Test Impedance M80-301/M80-313 @ 1.0 GHz M80-301/M80-313 @ 3.0 GHz M80-301/M80-313 @ 6.0 GHz M80-305/M80-311 @ 1.0 GHz M80-305/M80-311 @ 3.0 GHz M80-305/M80-311 @ 6.0 GHz Voltage Standing Wave Ratio M80-301/M80-313 @ 1.0 GHz M80-301/M80-313 @ 3.0 GHz M80-301/M80-313 @ 6.0 GHz M80-305/M80-311 @ 1.0 GHz M80-305/M80-311 @ 3.0 GHz M80-305/M80-311 @ 6.0 GHz h) Requirement Record Record Record Record Record Record Result 70.6 75.6 91.8 85.0 ax. Record Record Record Record Record Record 1.18 Max. 1.43 Max. 1.62 Max. 1.30 Max. 1.96 Max. 1.94 Max. Requirement Result 6.0 Max. 6.0 m Max. 6.0 Max. 2.0 m Max. 5.0 m Max. Max. 0.8 m Max. 5.1 m Max. No Damage No Damage No Damage No Damage Passed Passed Passed Passed Group 8 Acceleration Test Low-Level Contact Resistance M80-301/M80-313 Inner Contact M80-301/M80-313 Outer Contact M80-305/M80-311 Inner Contact M80-305/M80-311 Outer Contact M80-321/M80-331 M80-327/M80-331 Acceleration M80-301/M80-313 M80-305/M80-311 M80-321/M80-331 M80-327/M80-331 Low-Level Contact Resistance M80-301/M80-313 Inner Contact M80-301/M80-313 Outer Contact M80-305/M80-311 Inner Contact M80-305/M80-311 Outer Contact M80-321/M80-331 M80-327/M80-331 Harwin North America T: +1 603 893 5376 F: +1 603 893 5396 E: [email protected] W: www.harwin.com Issue: 1 Date: 21/11/2011 C/Note: ----- 6.0 m 6.0 m 6.0 m 6.0 m 6.0 m 6.0 m Max. Max. Max. Max. Max. Max. 5.4 m 1.7 m 5.5 m 5.8 m 0.7 m 5.0 m Max. Max. Max. Max. Max. Max. Harwin Europe T: +44 (0) 23 9231 4545 F: +44 (0) 23 9231 4590 Harwin Asia T: +65 6 779 4909 F: +65 6 779 386 E: [email protected] W: www.harwin.com E: [email protected] W: www.harwinasia.com Page 9 of 10 HT02001 Test Report for Datamate Mix-Tek General Testing i) Group 9 Current Test M80-327/M80-331 No. of contacts 1 Contact 2 Contacts 3 Contacts 4 Contacts 5 Contacts 6 Contacts 7 Contacts 8 Contacts 9 Contacts 10 Contacts 11 Contacts 12 Contacts M80-321/M80-331 No. of contacts 1 Contact 2 Contacts 3 Contacts 4 Contacts 5 Contacts 6 Contacts 7 Contacts 8 Contacts 9 Contacts 10 Contacts 11 Contacts 12 Contacts Harwin North America T: +1 603 893 5376 F: +1 603 893 5396 E: [email protected] W: www.harwin.com Issue: 1 Date: 21/11/2011 C/Note: ----- Requirement Result 20A or +30°C 20A or +30°C 20A or +30°C 20A or +30°C 20A or +30°C 20A or +30°C 20A or +30°C 20A or +30°C 20A or +30°C 20A or +30°C 20A or +30°C 20A or +30°C 25 amps / +24.7°C 20 amps / +29.6°C 20 amps / +40.8°C 20 amps / +32.1°C 20 amps / +31.3°C 20 amps / +35.1°C 20 amps / +50.2°C 20 amps / +49.1°C 20 amps / +62.2°C 20 amps / +71.5°C 20 amps / +79.5°C 20 amps / +87.3°C 20A or +30°C 20A or +30°C 20A or +30°C 20A or +30°C 20A or +30°C 20A or +30°C 20A or +30°C 20A or +30°C 20A or +30°C 20A or +30°C 20A or +30°C 20A or +30°C 25 amps / +39.0°C 20 amps / +29.7°C 20 amps / +34.6°C 20 amps / +53.4°C 20 amps / +59.2°C 20 amps / +66.6°C 20 amps / +67.5°C 20 amps / +80.7°C 20 amps / +72.1°C 20 amps / +93.7°C 20 amps / +100.6°C 20 amps / +104.1°C Harwin Europe T: +44 (0) 23 9231 4545 F: +44 (0) 23 9231 4590 Harwin Asia T: +65 6 779 4909 F: +65 6 779 386 E: [email protected] W: www.harwin.com E: [email protected] W: www.harwinasia.com Page 10 of 10