Solitel BE51-140 - Magnetrol International

SOLITEL®
Vibrating rod
level switches
for solids
DESCRIPTION
SOLITEL®, vibrating rod level switches are integral units,
providing a low cost and reliable level detection of bulk solids
in tanks or silos. The SOLITEL® is ideally suited for level
control on powders, granulars or lump materials up to a
minimum density of 0,05 kg/dm3.
From 235 mm up to 20 m insertion length
(9.25" up to 65.62')
F E AT U R E S
• 2 position density adjustment
(media with SG < 0,1 and > 0,1)
• SG as low as 0,05 kg/dm3 – granular size 10 mm (0.39")
• Status LED – built into cover
• Electro polished 316 TI (1.4571) vibrating rod
• Self-cleaning sensor
• Output: 8A SPDT relay (1A @ 24 V DC)
• Process Temperature: -40 °C to 160 °C
(-40 °F to 320 °F)
• Max Pressure: 25 bar abs. (360 psia)
A P P L I C AT I O N S
•
•
•
•
•
•
Pulverised coal
Cement
Lime
Cereals
Synthetic granulates
Perlite
P R I N C I P L E O F O P E R AT I O N
An invasive rod vibrates at 350 Hz frequency.
When in contact with the medium, the vibration will be
dampened.
The attenuation of the vibration will be detected by the
integral mount electronics, thus changing the status of the
output.
A G E N C Y A P P R O VA L
Agency
DMT
Approval
ATEX II 1/2 D IP 65 (Dust Ex)
MOUNTING
A deflection plate is
required when the
probe is exposed to
falling material or, in
case of a low level
switch, when the drag
force of the emtying
material exceed the
specifications.
Avoid mounting the sensor in a recess where
build-up could dampen
the vibration.
Other approvals are available, consult factory for more details
Worldwide level and flow solutions
S E L E C T I O N D ATA
A complete sensor consists of one order code:
1. One order code for electronics and sensor
2. Optional: threaded mounting flanges – consult factory
1. One order code for electronics and sensor
BASIC MODEL NUMBER
Standard electronics - max process temperature 110 °C (230 °F) - 95 °C (200 °F) for flexible version
V S H
V S R
V S K
Solitel with STANDARD sensor
Solitel with EXTENDED RIGID sensor
Solitel with FLEXIBLE sensor
- 235 mm (9.2") insertion length
- selectable insertion length / 10 cm (3.9") increments
- selectable insertion length / 1 m (3.3') increments
V H H
V H R
Solitel with STANDARD sensor
Solitel with EXTENDED RIGID sensor
- 235 mm (9.2") insertion length
- selectable insertion length / 10 cm (3.9") increments
High temperature electronics - max process temperature 160 °C (320 °F)
HOUSING MATERIAL / CABLE ENTRY / APPROVAL – IP 67
S
A
Aluminium, 4 entries (2x M20 x 1,5 and 2 x 1/2" NPT - all plugged)
Aluminium, 4 entries (2x M20 x 1,5 and 2 x 1/2" NPT - all plugged)
OUTPUT
2 B
Weatherproof
ATEX II 1/2 D IP 65 (Dust Ex)
SPDT relay 8 A @ 250 V AC / 1 A @ 24 V DC
POWER SUPPLY
A
D
85 .. 265 V AC / 120 ..375 V DC
19 .. 55 V DC / 16 .. 40 V AC
INSERTION LENGTH
0
0
3
0
0
V
2 B
0
5
0
0
2
0
0
0
1
0
VSH/VHH:
VSR/VHR:
VSK:
235 mm (9.2")
min 50 cm (19.7")
max 300 cm (9.8'), Specify length in 10 cm (3.9") increments
min 1 m (3.3')
max 20 m (65.60'), Specify length in 1 m (3,3') increments
complete order code for SOLITEL electronics and sensor
X = product with a specific customer requirement
PERFORMANCE
Description
Response time
Electromagnetic compatibility
Specification
< 1,8 s (when covered) – 2 s (when free) or with time delay: 5 s + 1,5 s (field selectable)
Meets CE requirements (EN 61000-6-4, EN 61000-6-2)
P H Y S I C A L / F U N C T I O N A L S P E C I F I C AT I O N S
Description
Specification
Housing material
IP 67, Aluminium (2x M20 x 1,5 and 2 x 1/2" NPT - all plugged)
2 x M20 x 1,5 cable gland separately included
Input voltage
Power consumption
Output
Indication
85 ... 265 V AC / 120 ... 375 V DC or 19 ... 55 V DC / 16 ... 40 V AC
1.3 VA
8 A SPDT relay @ 250 V AC (1A @ 24 V DC)
Output status LED (green/red) – visual indication on cover
Min density
Max mechanical load on sensor
Weight of unit
ATEX II 1/2 D IP 65
All wetted parts of polished 316 Ti SST (1.4571) (except VSK)
PE coated cable (VSK)
Threaded: 11/2" BSP (G 11/2)
VSH/VHH: 235 mm (9.2")
VSR/VHR: from 500 mm up to 3000 mm (19.7" up to 9.8')
VSK: from 1 m up to 20 m (3.3' up to 65.6')
25 bar abs. (360 psia)
Flexible version VSK: 6 bar abs. (87 psia)
0,05 kg/dm3 - max granular size: 10 mm (0,39")
VSH/VHH: 85 Nm
2,5 kg (VSH/VHH) + 1,4 kg/m for VSR/VHR + 0,6 kg/m for VSK
Description
Process temp.
Approvals
Sensor material
Mounting
Actuation length
Max pressure
Max temperature
VSH/VSR
VHH/VHR
VSK
-30 °C to +110 °C
(-20 °F to +230 °F)
-30 °C to +160 °C
(-20 °F to +320 °F)
-35 °C to +95 °C
(-30 °F to +200 °F)
Ambient temp.
-30 °C to +50 °C
(-20 °F to +120 °F)
-30 °C to +35 °C
(-20 °F to +95 °F)
-30 °C to +60 °C
(-20 °F to +140 °F)
ELECTRICAL CONNECTION
SPDT Relay (8 A @ 250 V AC / 1 A @ 24 V DC)
85 ... 265 V AC / 120 ... 375 V DC or 19 ... 55 V DC / 16 ... 40 V AC
temp. at process conn.
max +90 °C (+195 °F)
max +135 °C (+275 °F)
max +85 °C (+185 °F)
DIMENSIONS in mm (inches)
VSH/VHH
VSR/VHR
100 (3.94)
89 (3.50)
100 (3.94)
89 (3.50)
120
(4.72)
M20 x 1,5
2 entries
NPT
2 entries
1/2"
120
(4.72)
Ø 44 (1.73)
161
(6.34)
M20 x 1,5
2 entries
1/2"
NPT
2 entries
100 (3.94)
89 (3.50)
120
(4.72)
1/2"
Ø 44 (1.73)
Insertion
length
500 - 3000
(19.68 - 118.11)
M20 x 1,5
2 entries
NPT
2 entries
1 1/2" BSP
process connection
1 1/2" BSP
process connection
1 1/2" BSP
process connection
Insertion
length
235 (9.25)
VSK
Insertion
length
1000 - 20000
(39.37 - 787.40)
161
(6.34)
Ø 44 (1.73)
161
(6.34)
QUALITY ASSURANCE - ISO 9001:2008
THE QUALITY ASSURANCE SYSTEM IN PLACE AT MAGNETROL GUARANTEES THE HIGHEST LEVEL OF QUALITY DURING THE DESIGN,
THE CONSTRUCTION AND THE SERVICE OF CONTROLS.
OUR QUALITY ASSURANCE SYSTEM IS APPROVED AND CERTIFIED TO ISO 9001:2008 AND OUR TOTAL COMPANY IS COMMITTED TO
PROVIDING FULL CUSTOMER SATISFACTION BOTH IN QUALITY PRODUCTS AND QUALITY SERVICE.
PRODUCT WARRANTY
:2008
ALL MAGNETROL ELECTRONIC AND ULTRASONIC LEVEL CONTROLS ARE WARRANTED FREE OF DEFECTS IN MATERIALS AND WORKMANSHIP FOR ONE FULL YEAR FROM THE DATE OF ORIGINAL FACTORY SHIPMENT. IF RETURNED WITHIN THE WARRANTY PERIOD; AND, UPON FACTORY INSPECTION OF THE CONTROL, THE CAUSE OF THE CLAIM IS DETERMINED TO BE COVERED UNDER THE WARRANTY; THEN, MAGNETROL INTERNATIONAL WILL REPAIR OR
REPLACE THE CONTROL AT NO COST TO THE PURCHASER (OR OWNER) OTHER THAN TRANSPORTATION.
MAGNETROL SHALL NOT BE LIABLE FOR MISAPPLICATION, LABOR CLAIMS, DIRECT OR CONSEQUENTIAL DAMAGE OR EXPENSE ARISING FROM THE INSTALLATION
OR USE OF THE EQUIPMENT. THERE ARE NO OTHER WARRANTIES EXPRESSED OR IMPLIED, EXCEPT, SPECIAL WRITTEN WARRANTIES COVERING SOME MAGNETROL
PRODUCTS.
BULLETIN N°:
EFFECTIVE:
SUPERSEDES:
UNDER RESERVE OF MODIFICATIONS
Heikensstraat 6, 9240 Zele, België -Belgique
Tel. +32 (0)52.45.11.11 • Fax. +32 (0)52.45.09.93 • E-Mail: [email protected]
DEUTSCHLAND
Alte Ziegelei 2-4, D-51491 Overath
Tel. +49 (0)2204 / 9536-0 • Fax. +49 (0)2204 / 9536-53 • E-Mail: [email protected]
ITALIA
Via Arese 12, I-20159 Milano
Tel. +39 02 607.22.98 (R.A.) • Fax. +39 02 668.66.52 • E-Mail: [email protected]
INDIA
U.A.E.
UNITED
KINGDOM
C-20 Community Centre, Janakpuri, New Delhi - 110 0058
Tel. +91 (11) 41661840 • Fax +91 (11) 41661843 • E-Mail: [email protected]
DAFZA Office 5EA 722 • PO Box 293671 • Dubai
Tel. +971-4-6091735 • Fax +971-4-6091736 • E-Mail: [email protected]
OUR NEAREST REPRESENTATIVE
www.magnetrol.com
BENELUX
FRANCE
Unit 1 Regent Business Centre, Jubilee Road Burgess Hill West Sussex RH 15 9TL
Tel. +44 (0)1444 871313 • Fax +44 (0)1444 871317 • E-Mail: [email protected]
BE 51-140.9