KOTRON ® 805 SMART R.F. Level Transmitter ® The Kotron series 805 is a budget minded but “full function” 24 V DC, 2-wire loop powered smart RF transmitter. The microprocessor based electronics allow the user to calibrate the 805 with only one small level change. The electronics are housed in an ergonomical dual compartment housing which is directly mounted on top of the probe. The Kotron 805 comes in 2 versions: - blind transmitter - transmitter with local Magnecal™ system (LCD and keypad). Smart and budget minded Level solution FEATURES Blind Transmitter • Password protected Calibration using HART® communication. • One small level change needed for initial calibration. • Full diagnostics using HART® communication. • Analog output: 3.8mA to 20.5 per Namur NE 43. I VE Transmitter with local keypad/LCD • Calibration using HART®, or locally via a 2-line x 8 character LCD display and 3 pushbuttons. • Continuous local display of Level, % and loop signal. • Fault identification via FAULT message on LCD. GOT ABI LITY Other Features • Ergonomical - 45° angle, dual compartment housing isolates terminal board from electronics. • Transmitter head can be removed from probe without depressurizing the vessel. • Compatible with over 50 application oriented KOTRON® probes (see bulletin BE 50-125). Transmitter with LCD / keypad AGENCY APPROVALS APPLICATIONS • • • • Hydrocarbons & Solvents. Corrosives, Acids and Caustics. Powders & Granulars. High Temperature/Pressure Liquids. ATEX FM/CSA II 1G EEx ia IIC T4 (ambient -40 °C to +80 °C) II 1G EEx ia IIC T6 (ambient -40 °C to +40 °C) Intrinsically safe Non Incendive (Consult factory for proper partnumber) Worldwide level and flow solutions SELECTION DATA A complete measuring system consists of a: 1. Smart R.F. KOTRON® 805 amplifier. 2. KOTRON® Probe; a full range of rigid and flexible probes for conductive and non-conductive media is available (see bulletin BE 50-125). Rigid probes: from 150 mm (6") to 6000 mm (20') insertion length Flexible probes: from 1 m (3,28') to 45 m (150') insertion length 3. OPTION: HART communicator Magnetrol P/N : 089 - 5213 - 012 (Euro Plug) 089 -5213 - 013 (UK Plug) 1. Order code for SMART R.F. KOTRON® 805 amplifier BASIC MODEL NUMBER 8 0 5 Smart R.F. KOTRON® 805 amplifier SIGNAL OUTPUT 0 1 4 - 20 mA analog output 4 - 20 mA analog output with HART® communication MENU LANGUAGE 0 1 2 3 4 None, for use with blind transmitter (requires HART® communication) English for use with transmitter with LCD display and keypad Spanish for use with transmitter with LCD display and keypad French for use with transmitter with LCD display and keypad German for use with transmitter with LCD display and keypad TRANSMITTER TYPE 0 A Blind transmitter (requires HART® communication) Transmitter with 2 line x 8 character LCD display and keypad APPROVALS 1 A General Purpose (FM/CSA intrinsically safe) Intrinsically safe, ATEX II 1G EEx ia II C T6 HOUSING 1 2 Cast aluminium, dual compartiment housing – IP 65 Stainless steel, dual compartiment housing – IP 65 CABLE ENTRY 0 3/4" NPT (2 entries - one plugged) 1 M20 x 1.5 (2 entries - one plugged) 2 PG 13.5 (2 entries - one plugged) 8 0 5 5 complete order code for SMART R.F. KOTRON® 805 amplifier 2. Order code for KOTRON® Probe (see bulletin BE 50-125) A complete line of rigid and flexible probes are available for the Kotron 805 Transmitter. Types of probes to choose from include: • Rigid insulated rod probes in Teflon® (TFE), Halar® (ECTFE), and Kynar® (PVDF) • Rigid bare probes in 316 SS (1.4401) and Hastelloy C (2.4816) • Rigid all plastic probes in Halar® (ECTFE), and Kynar® (PVDF) • Bent, ground wire, and inactive sheath probes in many of the above materials • Stilling well probes • Sanitary probes • Reference rod probes • Flexible probes FUNCTIONAL/PHYSICAL Description Specification Power (at terminals) General Purpose: 11 to 36 V DC ATEX Intrinsically Safe: 11 to 28.6 V DC Signal Output 4-20 mA or 4-20 mA with HART® 3.8 to 20.5 mA useable (meets NAMUR NE 43) Span minimum 5 pF - maximum 10.000 pF Zero and Range 0 mm to 45 m (0' to 150') Resolution Analog: 0.01 mA Digital display: 0,1 cm (0.1") Loop Resistance ATEX Intrinsically Safe/General Purpose: 650 Ω @ 24 V DC Damping Adjustable 1-45 s Diagnostic Alarm Adjustable 3.6 mA, 22 mA, HOLD (3.6 mA is not valid if unit includes HART®) Digital Communication (HART®) compatible with software version 5.x User Interface 3-button keypad and/or HART communicator Display 2-line x 8-character LCD Approvals ATEX II 1 G EEx ia IIC T4/T6 or FM/CSA intrinsically safe / non incendive Electrical Data Ui = 28,6 V, li = 140 mA, Pi = 1 W Equivalent Data Ci = 2,2 nF; Li = 0,037 mH Menu Language English/Spanish/French or German Housing Material Aluminium A356T6 (< 0.25% copper) or 316 SST (1.4401)/IP 65 Net and Gross Weight 2.70 kg net; 3.20 kg gross Overall Dimensions H 214 mm (8.43") x W 111 mm (4.38") x D 188 mm (7.40") PROCESS CONDITIONS Description Specification Maximum Process Temperature 540 °C @ 35 bar (1000 °F @ 500 PSIG) - depending probe selection Maximum Process Pressure 345 bar @ 40 °C (5000 PSIG @ 100 °F) - depending probe selection Ambient temperature electronics -40 °C to +80 °C (-40 °F to +175 °F) – blind transmitter -20 °C to +70 °C (-5 °F to +160 °F) – with LCD display and keypad Storage temperature -40 °C to +80 °C (-40 °F to +175 °F) Humidity 0-99 %, non-condensing Electromagnetic Compatibility Meets CE requirements (EN-50081-2, EN 50082-2) / NAMUR NE 21 (EMV) PERFORMANCE Description Specification Reference conditions 20 °C (70 °F) Accuracy +/- 0.5% of span or 2.5 mm whichever is greater Resolution 0.1 pF Repeatability +/- 0.1% of span Linearity +/- 0.25% of span Response time less than 1 s (adjustable via damping) Ambient temperature effect approximately +0.03% per °C Warm up time less than 5 s 1200 20 mA 1000 23 mA 800 Ω 650 600 620 400 200 24 V DC 0 11 0 10 20 30 OUTPUT TABLE 40 V DC DIMENSIONS in mm (Inches) 105 (4.12) 83 (3.28) 45° View 200 (7.88) 214 (8.43) 126 (4.94) 98 (3.85) 111 (4.38) 45° Kotron 805 Housing front View 2 cable entries Mounting Flange 220 (8.66) 220 (8.66) Optional Mounting Flange Probe Insertion Length Optional Mounting Flange 3/4" NPT 3/4" NPT 1" NPT 1G (1" BSP) Optional Anchor Assembly Insertion Length 5 (0.1875) 6 (0.2500) 124 (4.87) 75 (2.95) 127 (5.00) 34 (1.32) 13 (0.50) - bare probe 16 (0.625) - insulated probe Kotron 805 Housing side view Rigid probe Optional Weight Flexible probe QUALITY ASSURANCE - ISO 9001 THE QUALITY ASSURANCE SYSTEM IN PLACE AT MAGNETROL GUARANTEES THE HIGHEST LEVEL OF QUALITY DURING THE DESIGN, THE CONSTRUCTION AND THE SERVICE OF CONTROLS. OUR QUALITY ASSURANCE SYSTEM IS APPROVED AND CERTIFIED TO ISO 9001 AND OUR TOTAL COMPANY IS COMMITTED TO PROVIDING FULL CUSTOMER SATISFACTION BOTH IN QUALITY PRODUCTS AND QUALITY SERVICE. PRODUCT WARRANTY ALL MAGNETROL ELECTRONIC AND ULTRASONIC LEVEL CONTROLS ARE WARRANTED FREE OF DEFECTS IN MATERIALS AND WORKMANSHIP FOR ONE FULL YEAR FROM THE DATE OF ORIGINAL FACTORY SHIPMENT. IF RETURNED WITHIN THE WARRANTY PERIOD; AND, UPON FACTORY INSPECTION OF THE CONTROL, THE CAUSE OF THE CLAIM IS DETERMINED TO BE COVERED UNDER THE WARRANTY; THEN, MAGNETROL INTERNATIONAL WILL REPAIR OR REPLACE THE CONTROL AT NO COST TO THE PURCHASER (OR OWNER) OTHER THAN TRANSPORTATION. MAGNETROL SHALL NOT BE LIABLE FOR MISAPPLICATION, LABOR CLAIMS, DIRECT OR CONSEQUENTIAL DAMAGE OR EXPENSE ARISING FROM THE INSTALLATION OR USE OF THE EQUIPMENT. THERE ARE NO OTHER WARRANTIES EXPRESSED OR IMPLIED, EXCEPT, SPECIAL WRITTEN WARRANTIES COVERING SOME MAGNETROL PRODUCTS. BULLETIN N°: EFFECTIVE: SUPERSEDES: UNDER RESERVE OF MODIFICATIONS Heikensstraat 6, 9240 Zele, België Tel. +32 (0)52.45.11.11 • Fax. +32 (0)52.45.09.93 • E-Mail: [email protected] DEUTSCHLAND Schloßstraße 76, D-51429 Bergisch Gladbach-Bensberg Tel. 02204 / 9536-0 • Fax. 02204 / 9536-53 • E-Mail: [email protected] FRANCE Le Vinci 6 - Parc d’activités de Mitry Compans, 1, rue Becquerel, 77290 Mitry Mory Tél. 01.60.93.99.50 • Fax. 01.60.93.99.51 • E-Mail: [email protected] ITALIA Via Arese 12, I-20159 Milano Tel. (02) 607.22.98 (R.A.) • Fax. (02) 668.66.52 • E-Mail: [email protected] UNITED KINGDOM Unit 1 Regent Business Centre, Jubilee Road Burgess Hill West Sussex RH 15 9TL Tel. (01444) 871313 • Fax (01444) 871317 • E-Mail: [email protected] INDIA B4/115 Safdurjung Enclave, New Delhi 110 029 Tel. 91 (11) 6186211 • Fax 91 (11) 6186418 • E-Mail: [email protected] www.magnetrol.com BENELUX OUR NEAREST REPRESENTATIVE BE 50-160.2 SEPTEMBER 2001 October 1999