MAGNETROL 810-0205-Y02

Kotron® Model 810
RF Point Level Switch
D E S C R I P T I O N
The Kotron Model 810 is a single point switch for alarm
applications using RF Capacitance technology. A guarded
probe and intrinsically safe probe circuit are provided.
The alarm point is tip sensitive in conductive media and
adjustable in non-conductive media. These units are
integral systems with the sensing probe mounted with
the electronics.
F E A T U R E S
• Sensitive and stable electronics detect even the most
non-conductive hydrocarbons
• Guard circuit and probe reject build-up of conductive
media
• Equipped with a 316 SS/Ryton probe available in
18" (450 mm) and 36" (920 mm) lengths
• Probe is ideal for high pressure applications – rated to
3500 psig at +100° F (240 bar at +40° C), 1750 psig at
+200° F (120 bar at +95° C)
A P P L I C A T I O N S
• Intrinsically safe probe circuitry allows safe use in
hazardous media
• 5A DPDT relay is usable in most standard alarm
applications
• LED shows the status of the relay and aids in calibration and troubleshooting
• Clean or dirty liquids
• Viscous liquids
• Light slurries
• High temperature/pressure liquids
• Foods and beverages
• Zero to 45 second time delay feature eliminates relay
"chatter" due to turbulence
• Powders and granulars
• Field selectable high level/low level failsafe
• Hydrocarbons and solvents
• Acids and caustics
T E C H N O L O G Y
The amount of capacitance developed in any vessel is
determined by the size (surface area) of the probe, the
distance from the probe to its ground, and the dielectric
of the medium being measured. Considering that the
probe’s mounting position is fixed, and that the dielectric
value of the medium is constant, then the amount of
capacitance developed in any vessel becomes dependent
upon the amount of the probe which is covered by
the media.
As media rises and falls in the tank, the amount of capacitance developed between the sensing probe and the
ground also rises and falls. This change in capacitance is
measured in the electronics. When the capacitance measurement is the same as the setpoint, an alarm occurs.
S P E C I F I C A T I O N S
Supply voltage
120 VAC, 50–60 Hz (+10%, -15%)
240 VAC, 50–60 Hz (+10%, -15%)
24 VDC (±10%)
12 VDC (±10%)
Power consumption
120 or 240 VAC Less than 5 volt-amps
12 or 24 VDC 1 watt maximum
Zero range
0 pF minimum to 500 pF maximum
Fixed differential
0.5 pF
Output relays ( reversible DPDT)
AC 5 amp @ 250 VAC resistive
DC 5 amp @ 30 VDC, 0.5 amp @ 125 VDC resistive
Response time
100 milliseconds
Repeatability
Better than 1.0%
Ambient temperature
Electronics -40° to +160° F (-40° to +70° C)
Operating process pressure/temperature
3500 psig @ +100° F (240 bar @ +40° C)
1750 psig @ +200° F (120 bar @ +95° C)
Temperature coefficient of set point
-40° to +160° F (-40° to +70° C) ±.01% per degree F of setpoint
(±.018% per degree C of setpoint)
A G E N C Y
A P P R O V A L S
Agency
Approved Model
Protection Method
Area Classification
FM
All models
Explosion Proof
Explosion proof with intrinsically safe probe circuit
Class I, Div. 1, Groups C & D
Class II, Div. 1, Groups E, F, & G
General purpose NEMA 4X
CSA
All models
Explosion Proof
Explosion proof with intrinsically safe probe circuit
Class I, Div. 1, Groups C & D
Class II, Div. 1, Groups E, F, & G
General purpose TYPE 4X
These units have been tested to EN 50081-2
and EN 50082-2 and are in compliance with
the EMC Directive 89/336/EEC.
2
M O D E L
N U M B E R
Models available for quick shipment, usually within one week after factory
receipt of a complete purchase order, through the Expedite Ship Plan (ESP).
BASIC MODEL
810
Kotron RF Capacitance Level Switch
INPUT POWER
0
120 VAC
1
240 VAC
2
3
24 VDC
12 VDC
HOUSING
D
NEMA 4X/7/9 Groups C & D, aluminum, 3⁄4" NPT conduit
Y
NEMA 4X/7/9 Groups C & D, 316 SS, 3⁄4" NPT conduit
PROBE
1
2
8
1
0
0
0
5
0
PROBE LENGTH vs.
DIELECTRIC CONSTANT
DIMENSIONAL
SPECIFICATIONS
I N C H E S
( m m )
If the geometry of your application requires a probe shorter
than 12" (305 mm) of active length, consult the chart below
Rotation clearance 3.44 (87)
to determine the minimum dielectric constant in which it can
4.63
(118) Dia.
3/4" NPT
be used.
2.75
(70)
4.11
(104)
6" (152)
Guard length
18" (455)
or
36" (915)
3/4" NPT
Conduit
connection
Minimum probe length (inches)
3/4" NPT
plugged
18" (455 mm) guarded probe
36" (915 mm) guarded probe
12
11
10
9
8
7
6
5
4
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
Minimum required dielectric constant of material
12" (305)
or
30" (762)
Active length
3
Q U A L I T Y
The quality assurance system in place at
Magnetrol guarantees the highest level of
quality throughout the company. Magnetrol
The Magnetrol quality assurance system is
registered to ISO 9001 affirming its commitment to known international quality
is committed to providing full customer
satisfaction both in quality products and
standards providing the strongest assurance
of product and service quality available.
quality service.
E S P
Expedite
Ship
Plan
Several Kotron Model 810 RF Point Switches
are available for quick shipment, usually
within one week after factory receipt of a
complete purchase order, through the
Expedite Ship Plan (ESP).
To take advantage of ESP, simply match the
color coded model number codes (standard
dimensions apply).
ESP service may not apply to orders of ten
units or more. Contact your local representative for lead times on larger volume orders,
as well as other products and options.
W A R R A N T Y
All Magnetrol electronic level and flow
controls are warranted free of defects in
materials or workmanship for one full year
from the date of original factory shipment.
If returned within the warranty period; and,
upon factory inspection of the control, the
cause of the claim is determined to be covered under the warranty; then, Magnetrol
will repair or replace the control at no cost
to the purchaser (or owner) other than
transportation.
Magnetrol shall not be liable for misapplication, labor claims, direct or consequential
damage or expense arising from the installation or use of equipment. There are no other
warranties expressed or implied, except
special written warranties covering some
Magnetrol products.
For additional information, see Instruction Manual 50-607.
5300 Belmont Road • Downers Grove, Illinois 60515-4499 • 630-969-4000 • Fax 630-969-9489 • www.magnetrol.com
145 Jardin Drive, Units 1 & 2 • Concord, Ontario Canada L4K 1X7 • 905-738-9600 • Fax 905-738-1306
Heikensstraat 6 • B 9240 Zele, Belgium • 052 45.11.11 • Fax 052 45.09.93
Regent Business Ctr., Jubilee Rd. • Burgess Hill, Sussex RH15 9TL U.K. • 01444-871313 • Fax 01444-871317
Copyright © 2011 Magnetrol International, Incorporated. All rights reserved. Printed in the USA.
Performance specifications are effective with date of issue and are subject to change without notice.
BULLETIN: 50-102.6
EFFECTIVE: January 2004
SUPERSEDES: February 2001