Kotron® Model 810 RF Point Level Switch D E S C R I P T I O N The Kotron Model 810 is a single point switch for alarm applications using RF Capacitance technology. A guarded probe and intrinsically safe probe circuit are provided. The alarm point is tip sensitive in conductive media and adjustable in non-conductive media. These units are integral systems with the sensing probe mounted with the electronics. F E A T U R E S • Sensitive and stable electronics detect even the most non-conductive hydrocarbons • Guard circuit and probe reject build-up of conductive media • Equipped with a 316 SS/Ryton probe available in 18" (450 mm) and 36" (920 mm) lengths • Probe is ideal for high pressure applications – rated to 3500 psig at +100° F (240 bar at +40° C), 1750 psig at +200° F (120 bar at +95° C) A P P L I C A T I O N S • Intrinsically safe probe circuitry allows safe use in hazardous media • 5A DPDT relay is usable in most standard alarm applications • LED shows the status of the relay and aids in calibration and troubleshooting • Clean or dirty liquids • Viscous liquids • Light slurries • High temperature/pressure liquids • Foods and beverages • Zero to 45 second time delay feature eliminates relay "chatter" due to turbulence • Powders and granulars • Field selectable high level/low level failsafe • Hydrocarbons and solvents • Acids and caustics T E C H N O L O G Y The amount of capacitance developed in any vessel is determined by the size (surface area) of the probe, the distance from the probe to its ground, and the dielectric of the medium being measured. Considering that the probe’s mounting position is fixed, and that the dielectric value of the medium is constant, then the amount of capacitance developed in any vessel becomes dependent upon the amount of the probe which is covered by the media. As media rises and falls in the tank, the amount of capacitance developed between the sensing probe and the ground also rises and falls. This change in capacitance is measured in the electronics. When the capacitance measurement is the same as the setpoint, an alarm occurs. S P E C I F I C A T I O N S Supply voltage 120 VAC, 50–60 Hz (+10%, -15%) 240 VAC, 50–60 Hz (+10%, -15%) 24 VDC (±10%) 12 VDC (±10%) Power consumption 120 or 240 VAC Less than 5 volt-amps 12 or 24 VDC 1 watt maximum Zero range 0 pF minimum to 500 pF maximum Fixed differential 0.5 pF Output relays ( reversible DPDT) AC 5 amp @ 250 VAC resistive DC 5 amp @ 30 VDC, 0.5 amp @ 125 VDC resistive Response time 100 milliseconds Repeatability Better than 1.0% Ambient temperature Electronics -40° to +160° F (-40° to +70° C) Operating process pressure/temperature 3500 psig @ +100° F (240 bar @ +40° C) 1750 psig @ +200° F (120 bar @ +95° C) Temperature coefficient of set point -40° to +160° F (-40° to +70° C) ±.01% per degree F of setpoint (±.018% per degree C of setpoint) A G E N C Y A P P R O V A L S Agency Approved Model Protection Method Area Classification FM All models Explosion Proof Explosion proof with intrinsically safe probe circuit Class I, Div. 1, Groups C & D Class II, Div. 1, Groups E, F, & G General purpose NEMA 4X CSA All models Explosion Proof Explosion proof with intrinsically safe probe circuit Class I, Div. 1, Groups C & D Class II, Div. 1, Groups E, F, & G General purpose TYPE 4X These units have been tested to EN 50081-2 and EN 50082-2 and are in compliance with the EMC Directive 89/336/EEC. 2 M O D E L N U M B E R Models available for quick shipment, usually within one week after factory receipt of a complete purchase order, through the Expedite Ship Plan (ESP). BASIC MODEL 810 Kotron RF Capacitance Level Switch INPUT POWER 0 120 VAC 1 240 VAC 2 3 24 VDC 12 VDC HOUSING D NEMA 4X/7/9 Groups C & D, aluminum, 3⁄4" NPT conduit Y NEMA 4X/7/9 Groups C & D, 316 SS, 3⁄4" NPT conduit PROBE 1 2 8 1 0 0 0 5 0 PROBE LENGTH vs. DIELECTRIC CONSTANT DIMENSIONAL SPECIFICATIONS I N C H E S ( m m ) If the geometry of your application requires a probe shorter than 12" (305 mm) of active length, consult the chart below Rotation clearance 3.44 (87) to determine the minimum dielectric constant in which it can 4.63 (118) Dia. 3/4" NPT be used. 2.75 (70) 4.11 (104) 6" (152) Guard length 18" (455) or 36" (915) 3/4" NPT Conduit connection Minimum probe length (inches) 3/4" NPT plugged 18" (455 mm) guarded probe 36" (915 mm) guarded probe 12 11 10 9 8 7 6 5 4 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 Minimum required dielectric constant of material 12" (305) or 30" (762) Active length 3 Q U A L I T Y The quality assurance system in place at Magnetrol guarantees the highest level of quality throughout the company. Magnetrol The Magnetrol quality assurance system is registered to ISO 9001 affirming its commitment to known international quality is committed to providing full customer satisfaction both in quality products and standards providing the strongest assurance of product and service quality available. quality service. E S P Expedite Ship Plan Several Kotron Model 810 RF Point Switches are available for quick shipment, usually within one week after factory receipt of a complete purchase order, through the Expedite Ship Plan (ESP). To take advantage of ESP, simply match the color coded model number codes (standard dimensions apply). ESP service may not apply to orders of ten units or more. Contact your local representative for lead times on larger volume orders, as well as other products and options. W A R R A N T Y All Magnetrol electronic level and flow controls are warranted free of defects in materials or workmanship for one full year from the date of original factory shipment. If returned within the warranty period; and, upon factory inspection of the control, the cause of the claim is determined to be covered under the warranty; then, Magnetrol will repair or replace the control at no cost to the purchaser (or owner) other than transportation. Magnetrol shall not be liable for misapplication, labor claims, direct or consequential damage or expense arising from the installation or use of equipment. There are no other warranties expressed or implied, except special written warranties covering some Magnetrol products. For additional information, see Instruction Manual 50-607. 5300 Belmont Road • Downers Grove, Illinois 60515-4499 • 630-969-4000 • Fax 630-969-9489 • www.magnetrol.com 145 Jardin Drive, Units 1 & 2 • Concord, Ontario Canada L4K 1X7 • 905-738-9600 • Fax 905-738-1306 Heikensstraat 6 • B 9240 Zele, Belgium • 052 45.11.11 • Fax 052 45.09.93 Regent Business Ctr., Jubilee Rd. • Burgess Hill, Sussex RH15 9TL U.K. • 01444-871313 • Fax 01444-871317 Copyright © 2011 Magnetrol International, Incorporated. All rights reserved. Printed in the USA. Performance specifications are effective with date of issue and are subject to change without notice. BULLETIN: 50-102.6 EFFECTIVE: January 2004 SUPERSEDES: February 2001