Renewable Energy Circuit Breakers and Disconnects HARNESS THE POWER About Carling Technologies Founded in 1920, Carling Technologies is a leading manufacturer of electrical and electronic switches and assemblies, hydraulic magnetic and thermal circuit breakers, electronic controls, power distribution units, digital switching systems, and multiplexed power distribution systems. With five ISO certified manufacturing facilities and corporate offices worldwide, Carling Technologies does much more than manufacture electrical components, it engineers powerful solutions! By applying its “Quality by Design” product development and manufacturing principles, Carling manufactures products that are not only highly efficient and cost effective but that also contribute to the ever-growing quest of harnessing clean energy. Renewable Energy Circuit Breakers & Disconnects When you integrate Carling Technologies circuit breakers into your renewable energy generating systems, you are guaranteed maximum protection against harmful overcurrent. Further, Carling’s circuit breakers utilize the hydraulic/magnetic principal offering many advantages over other thermal, thermal magnetic circuit breakers and fuses currently available. In other words, using Carling Technologies circuit breakers protects not only the power system itself, but it also safeguards the structure where these systems are installed by eliminating the fire hazard that can be caused by overcurrent. Table of Contents Selector Guide 2 CX-Series3 C-Series12 G-Series19 E-Series23 F-Series 30 Typical Photovoltaic System Selector Guide CX–SERIES C–SERIES G–SERIES E–SERIES F–SERIES NUMBER OF POLES 1- 2, + Auxiliary Switch Pole 1-6 (handle); 1-3 (rocker) 1-4 1-6 1-3 ACTUATOR STYLE Handle, 1 per pole Sealed Metal Toggle Handle, Rocker Handle Handle Handle AVAILABLE DELAYS DC: Instantaneous, Ultrashort, Short, Medium & Long Instantaneous, Ultrashort, Short, Medium & Long, AC, DC, AC/DC High Inrush - Short, Medium & Long AC and DC Instantaneous,Ultrashort, Short, Medium & Long, AC, DC High Inrush - Short, Medium & Long AC and DC Instant, Short, Medium & Long - AC, DC, and AC/DC High Inrush Short, Medium & LongAC, DC, and AC/DC Short, Medium & Long DC, AC MAXIMUM CURRENT & VOLTAGE RATINGS UL Recognized .2 -125A, 600VDC UL Listed .2-15A, 250/500VDC UL Listed 0.02-250A@80VDC 0.02-60A@125VDC 0.02-70A@120VAC 0.02-20A@240VAC ULRecognized 0.02-30A@480WYE /277VAC2-pole, 1Ø, 3-pole, 3Ø 0.02-50A@277VAC 0.02-100A@250VAC,80VDC 0.02-100A@120/240VAC, 65VDC UL Recognized 0.02-63A@80VDC 0.02-63A@240VAC 0.02-63A@480YVAC UL Listed 0.02-100A@240VAC, 65VDC, 125VDC ULRecognized 0.02-100A@277VAC, 160VDC, 1-pole 0.02-100A@600VAC, 2-pole 1Ø, 3 pole 3Ø 0.02-120A@125VDC, 1-pole UL489 Listed: 50-250A@125VDC 100-250A@120/240VAC 100-250A@277VAC 100-250A@208Y/120 3Ø UL489A Listed 250-700A@125VDC MAXIMUM INTERRUPTING CAPACITY Up to 10,000 UL Listed and UL recognized UL Listed 50000A@80VDC, 10,000A@120VAC, 5000A@125VDC, 240VAC ULRecognized 7500A@80VDC 3000A@125/250VAC, ULonly 5000A@250VAC 5000A@480WYE/277V AC w/fuse backup ULRecognized 3000A@80VDC 3000A@240VAC 1500A@480VAC UL Listed 25000A@65VDC 5000A@125VDC& 240VAC ULRecognized 5000A@125VDC 5000A@600VAC,without fuse backup 10000A@600VAC, w/fuse backup 50000A@125VDC 10000A, 120/240, 277, 208Y/120 AUXILIARY SWITCH RATING 20A, 80VDC (GO circuit) 10.1A@250VAC 0.1A@125VAC (gold contacts) 0.5A@65VDC 5A@125VAC 3A@32VDC 10.1A@250VAC 1.0A@65VDC 0.1A@80VDC 10.1A@250VAC 0.5A@65VDC 0.1A@80VDC AVAILABLE CIRCUITS Series Trip Series, Shunt,Relay, Switch Only, Series w/Remote Shutdown, Relay & Shunt Trip Dual Coil, Mid-Trip with Alarm Switch Series, Switch Only Series, Shunt, Relay, Switch Only, Series w/Remote Shutdown Series & Switch Only with or without Metering Shunt TERMINAL OPTIONS 10-32 or M5 Screw Terminals 1/4-20 or M6 Threaded Stud 10-32 Stud, 1/4-20 Stud, 0-32 Screw w/ saddle clamp, Clip Terminal, 1/4 & 7/16 Push-In Recessed Wire-ready, Pressure Plate Type Screw Terminals 10-32 Stud, 1/4-20 Stud 0-32 Screw, 1/4-20 Screw, Box Wire Connector 3/8-16 Stud, 3/8-16 Screw& Box Wire Connector MOUNTING METHOD Threaded insert: #6-32 UNC-2B, or M3X0.5-6H B ISO (2 per pole) Threaded inserts Rear Mounted on DIN Rail Rear or Front Panel Rear or Front Panel AGENCY APPROVALS UL489, UL1077, TUV (EN60934-2) UL, CSA, VDE, TUV, UL1500, UL489, UL489A UL1077, CUL UL, CSA, VDE, UL1500, UL489 CUL,TUV, UL489, UL489A ENVIRONMENTAL PROTECTION MIL-PRF-55629 & MIL-STD-202 Method 213, MIL-PRF-39019F when mounted in panel MIL-PRF-55629 & MIL-STD-202 Method 213, MIL-PRF-39019F when mounted in panel MIL-PRF-55629 & MIL-STD-202 MIL-PRF-55629 & MIL-STD-202F Method 213 MIL-PRF-55629 & MIL-STD-202F Method 213 OPERATING TEMPERATURE -40° C to +85° C -40° C to +85° C -40° C to +85° C -40° C to +85° C -40° C to +85° C 2www.carlingtech.com CX-Series Circuit Breaker The CX-Series circuit breaker features a unique and innovative arc-quenching configuration that allows the breaker to safely handle high amperage and high DC voltage applications in a compact package. By using a patent pending magnetic flux boosting terminal configuration, a strong magnetic field is created thus motivating the arc into an enhanced arc chamber improving the breaker’s overall performance and reliability. The permanent magnets located at the entrance of the arc chamber combined with the upper and lower arc runner increase the magnetic blow out force and aid in motivating the arc off of the contacts and into the arc chamber. An enhanced arc chamber features arc splitter retainers with integrated pressurizing walls, which facilitates heat transfer from the arc thereby providing additional cooling and quick transition into the magnetically induced splitter plates. In turn, the twelve (12) splitter plates attract, segment and cool the arc for full extinction. Combined, these innovative features make the CX-Series breaker the best in class, providing stable performance even in the most demanding applications. Applications: The CX-Series is UL 489B approved and ideal for integration into the combiner box or main disconnect of photovoltaic renewable energy systems. Additional Features: UL 489B approved Temperature stable hydraulic/magnetic overcurrent sensing technology. Optional relay trip circuit permitting remote operator system shut down. Choice of 6-32 or M3 mounting inserts providing secure panel mount installation. Choice of handle colors and legends, consult factory for details. www.carlingtech.com3 CX-Series Circuit Breaker - Design Features UPPER ARC RUNNER Aids in motivating arc off of movable contact and into arc chamber MAGNETS ARC SPLITTER RETAINER w/ integrated pressurizing walls (12) ARC DEIONIZING SPLITTER PLATES HYDRAULIC/MAGNETIC SENSING COIL PATENT PENDING MAGNETIC FLUX BOOSTING TERMINAL CONFIGURATION Design enhances motivation of arc into arc chamber LOWER ARC RUNNER Aids in motivating arc off of stationary contact and into arc chamber LARGE ARC GAP To generate high arc voltages 4www.carlingtech.com CX-Series Circuit Breaker - General Specifications Electrical Tables Table A: Lists UL Listed (UL489) configuration and performance capabilities as a Molded Case Circuit Breaker CX SERIES TABLE A : UL489 LISTED BRANCH CIRCUIT BREAKERS CIRCUIT CONFIGURATION VOLTAGE MAX. RATING FREQUENCY SERIES MAX CURRENT INTERRUPTING NUMBER RATING AMPS CAPACITY (AMPS) OF POLES 250 D.C. 15 5,000 1 250 / 500 D.C. 15 10,000 2 Table B: Lists UL Recognized configurations and performance capabilities as a Component Supplementary Protector CX SERIES TABLE B : UL1077 COMPONENT SUPPLEMENTARY PROTECTOR VOLTAGE CIRCUIT CONFIGURATION MAX. RATING SERIES SWITCH ONLY1 MAX INTERRUPTING CURRENT CAPACITY (AMPS) FREQUENCY RATING AMPS NUMBER APPLICATION OF POLES CODE 300 D.C. 1 - 75 5,000 1 TC1, OL0, U3 300 D.C. 76 - 125 3,000 1 TC1, OL0, U3 440 D.C. 1 -30 10,000 2 TC1, OL0, U3 440 D.C. 31 - 63 5,000 2 TC1, OL0, U3 600 D.C. 1 - 75 3,000 2 TC1, OL0, U3 600 D.C. 76 - 100 5,000 2 TC1, OL0, U3 600 D.C. 1 - 100 3,000 2 or 3 --- Notes: 1 Requires inclusion of a relay trip voltage coil Table C: Lists UL Listed (UL489B) configuration and performance capabilities as a Molded Case Switch CX SERIES TABLE C : UL489B LISTED PHOTOVATIC MOLDED CASE SWITCH VOLTAGE CIRCUIT CURRENT RATING INTERRUPTING CONFIGURATION MAX RATING FREQUENCY POLES (AMPS) RATING (AMPS) CONSTRUCTION NOTES 600 DC 21 50 - 100 600 May have a third pole that is a voltage trip pole 600 DC 42 110 - 175 600 May have a fifth pole that is a voltage trip pole SERIES Notes: 1 Two poles in series. 2 Two poles in series in parallel with 2 poles in series. Table D: TUV Certified Configuration to IEC / EN 60947-2. Low Voltage Switchgear and Controlgear - Circuit Breakers CX-SERIES TABLE D : TUV IEC/EN 60947-2 LOW VOLTAGE SWITCH GEAR & CONTROL GEAR / CIRCUIT BREAKER CIRCUIT CONFIGURATION SERIES VOLTAGE MAX. RATING FREQUENCY POLES 440 DC 2 CURRENT RATING (AMPS) 1-63 INTERRUPTING CAPACITY ICS / ICU (AMPS) 4,000 www.carlingtech.com5 CX-Series Circuit Breaker - General Specifications Electrical Mechanical Maximum Voltage Overload 600 VDC 50 operations at 600% of rated current for UL489, and at 150% of rated current for UL1077. RESISTANCEIMPEDANCE PER POLE VALUES RESISTANCE, VALUES fromfrom LineLine to Load Terminals to Load Terminals (ValuesBased Based on on Series Trip (Values Trip Circuit CircuitBreaker) Breaker) 1000 100 10 O H M S Current (amps) 0.1 -5.0 Tolerance (%) 15% 5.1-20.0 25% 20.1-125 35% Environmental 1 0.1 0.01 0.001 0.01 Endurance Max 10,000 ON-OFF operations @ 6 per minute; 6000 with rated current & voltage, and 4,000 cycles mechanical. Trip Free Trips on overload even when actuator is forcibly held in the “On” position. Trip Indication The operating handle moves positively to the “Off” position when an overload causes the breaker to trip. 0.1 1 10 AMPERE RATING 100-125 100 Physical Number of Poles Termination Termination Barrier Mounting Actuator Internal Circuit Config. Materials Weight Standard Color 1- 2 poles, + Auxiliary Switch Pole. 10-32 or M5 Screw Terminals 1/4-20 or M6 Threaded Stud Terminals Standard with multi-pole constructions Threaded insert: #6-32 UNC-2B, or M3X0.5-6H B ISO (2 per pole) Handle, 1 per pole. Series Trip Housing - Glass filled Polyester Handle - Glass filled Polyester Line/Load Terminals - Copper Alloy. ~150 Grams (~5.3 Ounces). ~150 Grams (~5.3 Ounces). Housing - Gray. Handle - White, Black, Red, Green, Blue, Yellow, Gray, Shock Vibration Moisture Resistance Salt Spray Thermal Shock Operating Temperature Withstands 100 Gs, 6ms saw tooth while carrying rated current per MILPRF-55629 and MIL-STD- 202G, Method 213G, Test Condition “I”. Instantaneous and ultra short curves tested at 90% of rated current Withstands 0.060” excursion from 10-55 Hz & 10 Gs 55-500 Hz, at rated current per MIL-PRF-55629 and MILSTD-202G, Method 240D, Test Cond. A. Instantaneous & ultrashort curves tested at 90% of rated current. MIL-PRF-55629 and MIL-STD- 202G, Method 106G, i.e., Ten 24- hour cycles at +25°C to +65°C, 80- 98% RH. Method 101, Condition A (90-95% RH at 5% NaCl Solution, 96 hrs). MIL-PRF-55629 and MIL-STD- 202G, Method 107G, Condition A (5-cycles at -55°C to +25°C to +85°C to +25°C). -40°C to +85°C. 6www.carlingtech.com CX-Series Circuit Breaker UL489B – Ordering Scheme C X 2 1 Series 2 Actuator S 0 4 Circuit 3 Poles 5 Relay Trip 1 SERIES C 4 5 Four Five 4 CIRCUIT S Switch Only 5 RELAY TRIP VOLTAGE COIL RATING1,2 0 w/o Relay Trip Voltage Coil A 12 VDC B 24 VDC C 32 VDC D 48 VDC 6 FREQUENCY & DELAY 03 DC Switch Only 7 CURRENT RATING (AMPERES) 1,3 2-Pole Section 4-Pole Section 650 50.00811 110.00 810 100.00 810 7 Current Rating 3 2 A 8 Terminal 9 Actuator Color & Legend 06 14 10 Mounting Inserts 11 Rating 12 Agency Approval 8 TERMINAL4,5 3 Stud, 1/4-20 6 Stud, M6 A Stud, 1/4-20, w/ 10-32 Screw Terminals on Voltage Pole B Stud, M6, w/ M5 Screw Terminals on Voltage Pole 2 ACTUATOR X Handle, one per pole 3 POLES1,2 2 Two 3 Three 03 6 Frequency & Delay 917 175.00 9 HANDLE COLOR & LEGEND Actuator Color I-O ON-OFF White AB Black CD Red FG Green HJ Blue KL Yellow MN Gray PQ Orange RS 10 MOUNTING INSERTS A 6-32 Thread B Dual Legend Color 1Black 2White 3White 4White 5White 6Black 7Black 8Black M3 Thread 11 MAX. APPLICATION RATING 06 600VDC 12 AGENCY APPROVAL A Without approvals 14 UL489B Listed Notes: 1 2 Pole Unit is required for ratings between 50A - 100A. 4 Pole Unit is required for ratings between 110A - 175A. 2 A Relay Trip Voltage Coil Pole may be added to either the 2 or 4 Pole construction. The addition of this extra pole dictates a change in the designation for the number of poles in selection 3. 3 For Current Ratings between 50A - 100A select current code 810 (100A). For Current Ratings between 101A - 175A select current code 917 (175A). 4 Voltage Pole must have screw terminals. Switch Pole must have stud terminals. 5 On 3 Pole Unit, Voltage Pole to be located at P1 as standard. On 5 Pole Unit, Voltage Pole to be located at P3 as standard. www.carlingtech.com7 CX-Series Circuit Breaker UL489B – Form & Fit Drawings OPTIONAL VOLTAGE POLE SEE NOTE 1 POLE 1 CX3 POLE 2 CX2 POLE 3 CX3 - 2 POLE SWITCH (CX2)SHOWN WITH OPTIONAL VOLTAGE POLE 50A-100A DEVICE, 600VDC POLE 1 OPTIONAL VOLTAGE POLE SEE NOTE 2 POLE 2 SEE NOTE 3 POLE 3 POLE 4 POLE 5 CX5 - 4 POLE SWITCH (CX4)SHOWN WITH OPTIONAL VOLTAGE POLE 101A-175A DEVICE, 600VDC Notes: 1 3 pole configuration supplied with voltage coil on pole 1. Optional location pole 3. Consult factory. 2 5 pole configuration supplied with voltage coil in center pole. (Pole 3) 3 Line & Load connections requires bus connection as shown. Minimum cross selection .127 in2 (81.94 mm2) 8www.carlingtech.com CX-Series Circuit Breaker - Delay Curves Instantaneous - DC 10 Ultrashort - DC 11 Short - DC 12 Medium - DC 14 Long - DC 16 www.carlingtech.com9 C-Series Circuit Breaker The C-Series hydraulic/magnetic circuit breakers are ideal for applications that require higher amperage and voltage handling capability in a smaller package. They are available in 1-6 poles, 0.02100amps, UL Recognized up to 480VAC or 150VDC, UL489 Listed up to 240VAC or 125VDC, with choice of time delays, terminal options, actuator styles and colors. Product Highlights: The UL489 C-Series employs a unique arc chute design which allows for higher interrupting capacities of up to 10,000 amps. New thermoset glass filled polyester half shell construction provides for increased mechanical and electrical strength. The wiping contacts, mechanical linkage with two step actuation, clean contacts providing high, positive contact pressure and longer contact life. Available with American Standard or Metric Threaded Stud terminals, or Saddle Clamp screw terminals. Optional mid-trip handle style actuator allows visual indication of electrical overload with or without alarm feature. Agency Certifications: UL Recognized UL Standard 1077 | UL Standard 508 UL Standard 1500 UL Listed UL Standard 489 | UL Standard 489A CSA Accepted | CSA Certified TUV Certified | VDE Certified 10www.carlingtech.com C-Series – General Specifications Electrical Table Lists UL Listed (489), CSA Certified (C22.2 No. 5.1-M) configuration and performance capabilities as a Molded Case Circuit Breaker. C SERIES TABLE D : UL489 LISTED BRANCH CIRCUIT BREAKERS CIRCUIT CONFIGURATION SERIES DUAL COIL INTERRUPTING CAPACITY (AMPS) WITHOUT FULL LOAD BACKUP FUSE AMPS CURRENT RATING VOLTAGE MAX. RATING FREQUENCY PHASE 80 DC --- 0.10 - 100 CONSTRUCTION NOTES 50,000 1 Limited to 2 Poles Max from 71 - 100 Amps. 10,000 Limited to 2 Poles Max from 71 - 100 Amps. 125 DC --- 0.10 - 100 5,000 1 - 3 Poles 125 / 250 DC --- 0.10 - 50 5,000 1 or 2 Poles (2 Poles Required for 250 Volts) 120 50 / 60 1 0.10 - 50 10,000 1 - 3 Poles 51 - 70 5,000 1 - 3 Poles 120 / 240 50 / 60 1 0.10 - 50 5,000 2 or 3 Poles. 1 Pole of a 3 Pole Unit is Neutral 0.10 - 50 10000 1 2 or 3 Poles. 1 Pole of a 3 Pole Unit is Neutral 240 50 / 60 1 0.10 - 30 5,000 1Pole 240 50 / 60 1 0.10 - 20 5,000 2 Pole 277 50 / 60 1 0.10 - 20 10,000 1Pole 120 50 / 60 1 0.10 - 30 10,000 --- Notes from Table D: 1 Special catalog number required. Consult factory. Agency Certifications: CSA Accepted UL Recognized UL Standard 1077 Component Recognition Program as Protectors, Supplementary Component Supplementary Protector under Class 3215 30, File 047848 0 000 (Guide CCN/QVNU2, File E75596) CSA Standard C22.2 No. 235 UL Standard 508 Motor Controllers, Manual CSA Certified Circuit Breaker Model Case (Guide CCN/NLRV2, File E135367) (Class 1432 01, File 093910), CSA Standard C22.2 No. 5.1 - M Marine Electrical & Fuel Systems TUV Certified EN60934, under License No. (Guide PEQZ2, File E75596) R72041016 Ignition Protection UL Standard 1500 Protectors, Supplementary for UL Listed UL Standard 489 Circuit Breakers, Molded Case, (Guide DIVQ, File E129899) UL Standard 489A Communications Equipment (Guide CCN/DITT, File E189195) VDE Certified EN60934, VDE 0642 under File No. 10537 www.carlingtech.com11 C-Series – General Specifications Mechanical Electrical Maximum Voltage AC, 480 WYE/277 VAC, 50/60 Hz (see Table A.) UL489: AC,240 VAC. (See Table D), 50/60 Hz, 125 VDC Current Rating Standard current coils: 0.100, 0.250, 0.500, 0.750, 1.00, 2.50, 5.00, 7.50, 10.0, 15.0, 25.0, 30.0, 35.0, 40.0, 50.0, 60.0, 70.0, 80.0, 90.0 and 100 amps. Other ratings available, see Ordering Scheme. Standard Voltage Coils DC - 6V, 12V; AC - 120V; other ratings available, see Ordering Scheme. Auxiliary Switch Rating SPDT; 10.1 amps-250VAC, DC Aux. Switch 1.0A, 65 VDC. 0.5A, 80VDC,1/4 HP, 125VAC,VDE & TUV 1.0 125 VAC. Insulation Resistance Minimum of 100 Megohms at 500 VDC. Dielectric Strength UL, CSA: 1960 V 50/60 Hz for one minute between all electrically isolated terminals. C-Series Circuit Breakers comply with the 8mm spacing and 3750V 50/60 Hz dielectric requirements from hazardous voltage to operator accessible surfaces, between adjacent poles and from main circuits to auxiliary circuits per Publications EN 60950 and VDE 0805. Resistance, Impedance Values from Line to Load Terminal based on Series Trip Circuit Breaker. RESISTANCE, IMPEDANCE VALUES from Line to Load Terminals (Values Based on Series Trip Circuit Breaker ) 1000 CURRENT (AMPS) TOLERANCE (%) 0.10 - 5.0 15% 20.1 - 100.0 35% 100 5.1 - 20.0 10 O H M S 1 0.1 60 Hz 1/2 Cycle Inrush Pulse Tolerance Time Delay Curves 42, 44 & 46 (50 Amps Max.) Multiple of Rated Current Ir 25x 0.01 Time Delay Curves 22, 24 (100 Amps Max.) 26 (70 Amps Max.) 12x 0.001 0.01 1 0.1 10 25% 100 t AMPERE RATING 4.165 8.33 16.67 Pulse Tolerance Curves TOLERANCE (%) 15% 25% 35% 25x Ir 1 Multiple of Rated Current FIGURE Time Delay Curves 42, 44 & 46 (50 Amps Max.) Multiple of Rated Current Ir CURRENT (AMPS) 0.100 - 5.0 - 20.0 60 Hz 1/25.1 Cycle - 100 Inrush Pulse20.1 Tolerance Time Delay Curves 22, 24 (100 Amps Max.) 26 (70 Amps Max.) 12x Time Delay Curves 42, 44 & 46 (50 Amps Max.) Time Delay Curves 22, 24 (100 Amps Max.) 26 (70 Amps Max.) 10x t t 4.165 Ir Multiple of Rated Current 50 Hz 1/2 Cycle Inrush Pulse Tolerance 22x 8.33 5.0 16.67 Time Delay Curves 42, 44 & 46 (50 Amps Max.) Time Delay Curves 22, 24 (100 Amps Max.) 26 (70 Amps Max.) 10x 20.0 Time in Milliseconds 50 Hz 1/2 Cycle Inrush Pulse Tolerance 22x 10.0 Endurance 10,000 ON-OFF operations @ 6 per minute; with rated current & voltage. Trip Free All C-Series circuit breakers will trip on overload, even when actuator is forcibly held in the ON position. Trip Indication The operating actuator moves positively to the OFF position when an overload causes the breaker to trip. With mid-trip, handle moves to the mid position on electrical trip of the circuit breaker. With mid trip handle with alarm switch, handle moves to the mid position and the alarm switch actuates when the circuit breaker is electrically tripped. Physical Number of Poles Internal Circuit Config. Weight Standard Colors 1-6 poles ≤ 50A; 1-4 poles @ 5170A; 1-2 poles 71-100A. UL489 Handle: 1 pole ≤ 100A, 2 pole ≤ 50A; Rocker: 1 pole ≤ 100A. Series (with or without auxiliary switch, mid trip & mid trip with alarm switch) Shunt & Relay with current or voltage trip coils, Dual Coil, Switch Only (with or without aux. switch). UL489: Series (with or without auxiliary switch, mid-trip & midtrip with alarm switch). Approx.112 grams/pole ( 3.95 oz). Housing: Black Environmental Designed and tested in accordance with requirements of specification MIL-PRF-55629 & MIL-STD-202 as follows: Shock Vibration Moisture Resistance Salt Spray Thermal Shock Operating Temperature Withstands 100 Gs, 6ms sawtooth while carrying rated current per Method 213, Test Condition “I”. Instantaneous and ultrashort curves tested @ 90% of rated current. Withstands 0.060” excursion from 10-55 Hz & 10 Gs 55-500 Hz, @ rated current per Method 204C, Test Cond. A. Instantaneous & ultrashort curves tested @ 90% of rated current. Method 106D, i.e., ten 24-hour cycles @ +25°C to +65°C, 80-98% RH. Method 101, Condition A (90-95% RH @ 5% NaCl Solution, 96 hrs). Method 107D, Condition A (five cycles @ -55°C to +25°C to +85°C to +25°C). -40°C to +85°C t 5.0 10.0 20.0 Time in Milliseconds 12www.carlingtech.com C-Series Handle UL489 Listed – Ordering Scheme C A 3 1 Series 2 Actuator B 0 4 Circuit 3 Poles 14 5 Aux/Alarm Switch 6 Frequency & Delay CODE 2 ACTUATOR1 Handle, one per pole Handle, one per multipole unit Mid-Trip Handle, one per pole Mid-Trip, one per pole & Alarm Switch 3 POLES2 1 One 2 3 Two Three 4 CIRCUIT B Series Trip (current) 5 AUXILIARY/ALARM SWITCH3 0 2 3 4 without Aux Switch S.P.D.T., 0.110 Q.C. Term. S.P.D.T., 0.139 Solder Lug S.P.D.T., 0.110 Q.C. Term. (Gold Contacts) 6 FREQUENCY & DELAY 11 12 14 16 21 22 24 DC Ultra Short DC Short DC Medium DC Long 50/60Hz Ultra Short 50/60Hz Short 50/60Hz Medium 1 2 1 8 Terminal 9 Actuator Color 10 Mounting/ Barriers K G 11 Max. App. Rating 12 Agency Approval 7 CURRENT RATING (AMPERES) 5 1 SERIES C A B S T 450 7 Current Rating 6 8 9 S.P.S.T., 0.139 Solder Lug S.P.S.T., 0.187 Q.C. Term. S.P.D.T., 0.187 Q.C. Term. 26 424 444 464 524 544 564 50/60Hz Long 50/60Hz Short, Hi-Inrush 50/60Hz Medium, Hi-Inrush 50/60Hz Long, Hi-Inrush DC Short, Hi-Inrush DC Medium, Hi-Inrush DC Long, Hi-Inrush Notes: 1 Actuator Code: A: Handle tie pin spacer(s) and retainers provided assembled with multi-pole units. B: Handle located, as viewed from front of breaker in left pole. 2 pole maximum. S: Handle moves to mid-position only upon electrical trip of the breaker. T: Handle moves to mid-position and alarm switch activates only upon electrical trip of the breaker. 2 Standard multipole units have all poles identical except when specifying auxiliary switch and/or mixed poles. 2 & 3 pole circuit breakers required for 120/240 VAC (Maximum application rating code C) applications, have all poles identical except when specifying auxiliary / alarm switch which is normally supplied in extreme right pole per figure B. Terminal barriers are required on all multipole breakers. Third pole is for 120/240 VAC applications requiring neutral disconnect. The 3rd pole has the same construction as poles 1 & 2. 3 On multi-pole breakers, one auxiliary. switch is supplied, mounted in the extreme right pole. VDE approval on auxiliary switch codes 2, 3 & 4 only. Auxiliary / Alarm Switch with Independent Circuit ie: separate from breaker circuit, only available with circuit breakers rated 50 amp maximum at 80 VDC, 125 VDC, and 120 VAC. Auxiliary / Alarm Switch with Dependent Circuit ie: same as circuit breaker, is supplied from factory with common terminal of auxiliary / alarm switch connected to line terminal on 120/240 and 240 VAC ratings. Circuit breakers rated 120 VAC 50 amp maximum can be supplied with Auxiliary/Alarm switch common terminal connected to breaker line terminal. Consult factory for special catalog number. 4 Available up to 50 amps maximum. 5 Current ratings 71 - 100 with VDE approvals are available up to two poles maximum. 6 Terminal Codes 8, 9 & C are not VDE approved. 7 Terminal Code 1 available to 60 amps maximum. 8 Terminal Codes 2, 4, 5 & C available to 50 amps maximum. 9 Terminal Codes 3, 6 & 9 available to 100 amps maximum. 10 Terminal Code A available to 100 amps maximum. 11 VDE and TUV approvals require Dual (I-O, ON-OFF) markings on all handles. 12 Barriers supplied on multi-pole units only. AMPERES 210 0.100 2150.150 220 0.200 2250.250 230 0.300 235 0.350 240 0.400 245 0.450 250 0.500 2550.550 2600.600 265 0.650 2700.700 2750.750 2800.800 2850.850 290 0.900 295 0.950 410 1.000 512 1.250 415 1.500 5171.750 420 2.000 522 2.250 4252.500 5272.750 4303.000 4353.500 440 4.000 445 4.500 4505.000 4555.500 4606.000 4656.500 4707.000 475 7.500 4808.000 4858.500 4909.000 4959.500 61010.000 71010.500 61111.000 71111.500 61212.000 71212.500 61313.000 61414.000 615 15.000 61616.000 61717.000 8 TERMINAL6 1 7 2 8 3 9 4 8 5 8 6 9 8 9 9 A10 C Stud 10-32, threaded Screw 10-32 Stud 1/4-20, threaded Stud M5 x 0.8, threaded Screw M5 x 0.8 618 18.000 62020.000 62222.000 624 24.000 62525.000 63030.000 63535.000 64040.000 660 60.000 670 70.000 680 80.000 685 85.000 690 90.000 695 95.000 810 100.000 Screw M6, threaded 1/4” Clip Terminal 7/16” Clip Terminal Plug-In Stud 5/16” Clip Terminal 9 ACTUATOR COLOR & LEGEND11 Actuator Color White Black Red Green Blue Yellow Gray Orange ON-OFF Dual Legend Color B1 Black D2 White G3 White J 4 White L 5 White N 6 Black Q 7 Black S 8 Black 10 MOUNTING/BARRIERS 1 2 MOUNTING STYLE Threaded Insert 6-32 x 0.195 inches ISO M3 x 5mm BARRIERS12 yes yes 11 MAXIMUM APPLICATION RATING A B C D K F M 65 DC 125 DC 120/240 AC2 240 AC 120 AC 277 AC 80 DC 12 AGENCY APPROVAL11 A F G J w/o approvals UL489 Listed, CSA Certified & VDE Certified UL489 Listed & CSA Certified UL489 Listed, CSA Certified & TUV Certified www.carlingtech.com13 C-Series Handle – Circuit & Terminal Diagrams .960 [24.38] .311 DIA [Ø7.90] .558 [14.17] Notes: 1 2 3 All dimensions are in inches [millimeters]. Tolerance ±.020 [.51] unless otherwise specified. Available on Series Trip and Switch Only Circuits when called for on multi-pole units. Only one aux. switch is normally supplied, as viewed in mulit-pole identification scheme. 14www.carlingtech.com C-Series Handle – Circuit & Terminal Diagrams LINE LOAD Notes: 1 2 3 4 All dimensions are in inches [millimeters]. Tolerance ±.020 [.51] unless otherwise specified. Schematic shown represents current trip circuits. Available only as special catalog number. www.carlingtech.com15 C-Series Handle – Form & Fit Drawings LINE LOAD Notes: 1 2 All dimensions are in inches [millimeters]. Tolerance ±.020 [.51] unless otherwise specified. 16www.carlingtech.com G-Series Circuit Breaker Carling Technologies’ G-Series hydraulic/ magnetic circuit breakers offer the highest quality solution to your circuit protection requirements. The G-Series is designed to sense over-current conditions and protect an electrical system’s wires and equipment. When left unchecked overcurrent conditions will result in fires and costly damage. Hydraulic/magnetic circuit breakers are considered to be temperature stable and not adversely affected by temperature changes in their operating environment. As such, derating considerations due to temperature variations are not required, and heatinduced nuisance tripping is avoided. Key Features: 1-4 poles 0.02 - 63 Amps 80 VDC, 240 VAC, 480 VAC Mid-trip actuator indication Precise temperature independent operation Wiping contacts – mechanical linkage with two-step actuation – cleans contacts and ensures longer contact life Wide choice of trip time delay curves Optional integrated auxiliary contacts Unique terminal bus connection system DIN rail mounting Finger safe terminals Suitable for reverse feed Common trip linkage between poles – ensures that an overload in one pole will trip all adjacent poles www.carlingtech.com17 G–Series DIN Rail – General Specifications Electrical Tables Table A: Lists UL Recognized, CSA Accepted and TUV Certified configurations and performance capabilities as a Component Supplementary Protector. CIRCUIT VOLTAGE CONFIGURATION G SERIES - COMPONENT SUPPLEMENTARY PROTECTOR CURRENT SHORT CIRCUIT CAPACITY (AMPS) MAX SERIES RATING FREQ. PHASE 80 DC -- 240 50/60 1 240 50/60 1 480 50/60 3 FULL LOAD 63 63 63 63 MINIMUM POLES UL WITHOUT BACKUP FUSE CSA WITHOUT BACKUP FUSE TUV WITHOUT BACKUP FUSE UL CSA 1 3000 3000 1500 TC1, OL1, U1 TC1, OL1, U1 1 3000 3000 1500 TC1, OL1, U1 TC1, OL1, U1 2 3000 3000 1500 TC1, OL1, U1 TC1, OL1, U1 3 1500 1500 415V, 1000 TC1, OL1, U1 TC1, OL1, U1 Electrical Mechanical Maximum Voltage AC: 240VAC (single pole), 440VAC (3 poles, additional pole shall be dedicated for neutral break) DC: 110VDC (single pole and multipole) Current Rating 0.2 – 63A. Other ratings available, see Ordering Scheme. Auxiliary Switch Rating (optional) Integrated, load side. SPST, 3A – 125Vac, 2A – 30Vdc. Auxiliary switch senses the on & off position of circuit breaker handle, as well as contact arm position. Switch connections are screw terminals. Insulation Resistance Minimum of 100 Megohms at 500 VDC. Dielectric Strength UL, CSA: 1960 V 50/60 Hz for one minute between all electrically isolated terminals. G-Series Circuit Breakers comply with the 8mm spacing and 3750V 50/60 Hz dielectric requirements from hazardous voltage to operator accessible surfaces, between adjacent poles and from main circuits to auxiliary circuits per Publications EN 60950 and VDE 0805. Resistance, Impedance Values from Line to Load Terminal - based on Series Trip Circuit Breaker. Endurance RESISTANCE, IMPEDANCE VALUES from Line to Load Terminals (Values Based on Series Trip Circuit Breaker) 1000 100 10 O H M S 6 1 0.1 0.01 0.001 0.01 0.1 1 10 AMPERE RATING Trip Free Trip Indication Fire and smoke Physical Number of Poles Weight Standard Colors APPLICATION CODES 10,000 ON-OFF operations @ 6 per minute; with rated current & voltage. All G-Series circuit breakers will trip on overload, even when actuator is forcibly held in the ON position. The operating actuator moves positively to the OFF position when an overload causes the breaker to trip. With mid-trip, the handle moves to the mid position on electrical trip of the circuit breaker. With mid trip handle with alarm switch, handle moves to the mid position and the alarm switch actuates when the circuit breaker is electrically tripped. NF F16-101/102, DIN5510 & BS6853 fire and smoke material selection & application for electrical equipment. 1 pole ≤ 63A, 2 poles ≤ 63A per pole Approx.172 grams/pole ( 4.13 oz). Housing: Black Environmental Designed in accordance with requirements of specification MIL-PRF-55629 & MIL-STD-202 as follows: Withstands 100 Gs, 6ms sawtooth Shock while carrying rated current per Method 213, Test Condition “I”. Instantaneous and ultrashort curves tested @ 90% of rated current. Withstands 0.060” excursion from Vibration 10-55 Hz & 10 Gs 55-500 Hz, @ rated current per Method 204C, Test Cond. A. Instantaneous & ultrashort curves tested @ 90% of rated current. Method 106D, i.e., ten 24-hour cycles Moisture Resistance @ +25°C to +65°C, 80-98% RH. Method 101, Condition A (90-95% RH Salt Spray @ 5% NaCl Solution, 96 hrs). Method 107D, Condition A (five cycles Thermal Shock @ -55°C to +25°C to +85°C to +25°C). Operating Temperature -40°C to +85°C 100 *Manufacturer reserves the right to change product specification without prior notice. 18www.carlingtech.com G–Series DIN Rail – Ordering Scheme & Dimensional Specifications G A 1 1 Series 2 Actuator 3 Poles B 0 4 Circuit 24 5 Aux/Alarm Switch 6 Frequency & Delay 1 2 ACTUATOR1 1 S Handle, one per pole 3 POLE One 2 Two 4 CIRCUIT A2 Switch Only (no coil) 5 AUXILIARY/ALARM SWITCH3 0 1 w/o Aux Switch S.P.D.T., screw terminal 6 FREQUENCY & DELAY 032 10 11 12 14 16 20 21 22 DC 50/60Hz, Switch Only DC Instantaneous DC Ultra Short DC Short DC Medium DC Long 50/60Hz Instantaneous 50/60Hz Ultra Short 50/60Hz Short 3 Mid-Trip Handle, one per pole Three 4 Four1 B Series Trip (current) 3 S.P.D.T. screw terminal/ Gold contacts 24 26 424 444 464 524 544 564 50/60Hz Medium 50/60Hz Long 50/60Hz Short, Hi-Inrush 50/60Hz Medium, Hi-Inrush 50/60Hz Long, Hi-Inrush DC Short, Hi-Inrush DC Medium, Hi-Inrush DC Long, Hi-Inrush 7 CURRENT RATING (AMPERES) CODE AMPERES 220 225 230 235 240 245 250 255 260 265 270 275 280 285 290 0.200 0.250 0.300 0.350 0.400 0.450 0.500 0.550 0.600 0.650 0.700 0.750 0.800 0.850 0.900 7 Current Rating 1 1 8 Terminal D C 9 Actuator Color & Legend 10 Rating 11 Agency Approval 8 TERMINAL 1 SERIES G A 620 295 410 512 415 517 420 522 425 527 430 435 440 445 450 455 0.950 1.00 1.25 1.50 1.75 2.00 2.25 2.50 2.75 3.00 3.50 4.00 4.50 5.00 5.50 460 465 470 475 480 485 490 495 610 710 611 711 612 712 613 6.00 6.50 7.00 7.50 8.00 8.50 9.00 9.50 10.00 10.50 11.00 11.50 12.00 12.50 13.00 614 615 616 617 618 620 622 624 625 630 635 640 650 660 663 Screw Terminal 9 ACTUATOR COLOR & LEGEND Actuator Color I-O ON-OFF White A B Black C D Red F G Green H J Blue K L Yellow M N Gray P Q Orange R S 10 MAX. APPLICATION RATING M 80VDC D 240VAC Dual 1 2 3 4 5 6 7 8 Legend Color Black White White White White Black Black Black H 480VAC 5 11 AGENCY APPROVAL A Without approvals C UL Recognized, CUL E UL Recognized, CUL, TUV Notes: 1 4th pole for neutral break only. 2 Switch only construction currently only available on multipole units when at least one pole is a protected pole. 3 On multipole breakers, one auxiliary switch is supplied, mounted in the extreme right pole. (when viewed from back.) 4 High Inrush delays limited to 50A max. 5 480V only available as three or four pole. Two pole is not available. 14.00 15.00 16.00 17.00 18.00 20.00 22.00 24.00 25.00 30.00 35.00 40.00 50.00 60.00 63.00 Time Delay Values PERCENT OF RATED CURRENT Notes: Delay Curves 11,12,14,16,21,22,24,26,42,44,46,52,54,56: Breakers to hold 100% and must trip at 125% of rated current and greater within the time limit shown in this curve. Delay Curves 10,20: Breakers to hold 100% and must trip at 150% of rated current and greater within the time limit shown in this curve. All Curves: Curve data shown represents breaker response at ambient temperature of 77°F (25°C) with no preloading. Breakers are mounted in standard wall-mount position. On 50 amp and less current ratings, the minimum inrush pulse tolerance handling capability is 12 times the rated current on standard delays and 25 times the rated current on high inrush delays. These values are based on a 60 Hz 1/2 cycle, 8.33 ms pulse. High inrush delays should be specified for applications with high initial surge currents of short duration such as switching power supplies, highly capacitive loads and transformer loads. www.carlingtech.com19 G-Series DIN Rail Circuit Breaker - Delay Curves PERCENT OF RATED CURRENT Medium - DC 14 Long - DC 16 D.C. LONG DELAY CURVE NO. 16 Instantaneous - AC 20 Ultrashort - AC 21 50/60 Hz ULTRASHORT DELAY CURVE NO. 21 PERCENT OF RATED CURRENT PERCENT OF RATED CURRENT Medium - AC 24 Long - AC 26 50/60 Hz MEDIUM DELAY CURVE NO. 24 Medium - High Inrush AC 44 50/60 Hz - HI-INRUSH MEDIUM DELAY CURVE NO. 44 PERCENT OF RATED CURRENT PERCENT OF RATED CURRENT Short - High Inrush DC 52 Medium - High Inrush DC 54 PERCENT OF RATED CURRENT TRIP TIME IN SECONDS TRIP TIME IN SECONDS TRIP TIME IN SECONDS Short - High Inrush AC 42 TRIP TIME IN SECONDS PERCENT OF RATED CURRENT D.C. - HI-INRUSH SHORT DELAY CURVE NO. 52 50/60 Hz SHORT DELAY CURVE NO. 22 PERCENT OF RATED CURRENT 50/60 HZ LONG DELAY CURVE NO. 26 PERCENT OF RATED CURRENT 50/60 Hz - HI-INRUSH SHORT DELAY CURVE NO. 42 Short - AC 22 TRIP TIME IN SECONDS PERCENT OF RATED CURRENT TRIP TIME IN SECONDS PERCENT OF RATED CURRENT 50/60 Hz INSTANTANEOUS CURVE NO. 20 D.C. SHORT DELAY CURVE NO. 12 PERCENT OF RATED CURRENT D.C. - HI-INRUSH MEDIUM DELAY CURVE NO. 54 PERCENT OF RATED CURRENT Long - High Inrush AC 46 TRIP TIME IN SECONDS D.C. MEDIUM DELAY CURVE NO. 14 TRIP TIME IN SECONDS PERCENT OF RATED CURRENT TRIP TIME IN SECONDS D.C. ULTRASHORT DELAY CURVE NO. 11 50/60 Hz - HI-INRUSH LONG DELAY CURVE NO. 46 PERCENT OF RATED CURRENT Long - High Inrush DC 56 TRIP TIME IN SECONDS TRIP TIME IN SECONDS D.C. INSTANTANEOUS CURVE NO. 10 Short - DC 12 Ultrashort - DC 11 TRIP TIME IN SECONDS TRIP TIME IN SECONDS TRIP TIME IN SECONDS TRIP TIME IN SECONDS TRIP TIME IN SECONDS Instantaneous - DC 10 D.C. - HI-INRUSH LONG DELAY CURVE NO. 56 PERCENT OF RATED CURRENT 20www.carlingtech.com E-Series Circuit Breaker The E-Series hydraulic/magnetic circuit breaker is ideally suited for higher current and voltage applications. It is UL listed and CSA certified for branch circuit protection, which does not require a fuse back up. It is also UL recognized and CSA certified as a supplementary protector and as a manual motor controller. Its physical features include front and back mounting, screw and stud terminals and heavy duty box wire connectors for solid wire or a pressure plate connector for standard wire. The E-series is available with handle actuators and can be configure as .1100 amps, up to 600VAC or 125VDC, with choice of time delays, actuator colors and 1 to 6 poles configuration. Additionally, a Power Selector device is also available. Product Highlights: UL listed and CSA certified Certified for circuit branch protection Certified as a supplementary protector and as a manual motor controller Optional Power Selector Device www.carlingtech.com21 E-Series Circuit Breaker - General Specification Electrical Mechanical Maximum Voltage 600VAC 50/60 Hz, 125VDC (See Table A) Current Ratings Standard current coils: 0.100, 0.250, 0.500, 1.00, 2.50, 5.00, 7.50, 10.0, 15.0, 20.0, 25.0, 30.0, 50.0, 60.0, 70.0 & 100 Amp. Auxiliary Switch Rating SPDT; 10.1A 250VAC, 1.0A 65VDC; 0.5A 80VDC, 0.1A 125VAC (with gold contacts). Insulation Resistance Minimum of 100 Megohms at 500 VDC. Dielectric Strength UL, CSA: 2200 V 50/60 Hz for one minute between all electrically isolated terminals. E-Series Circuit Breakers comply with the 8mm spacing and 3750V 50/60 Hz dielectric requirements from hazardous voltage to operator accessible surfaces, between adjacent poles and from main circuits to auxiliary circuits per Publications EN 60950 and VDE 0805. Resistance, Impedance Values from Line to Load Terminal - based on Series Trip Circuit Breaker. Endurance 10,000 ON-OFF operations @ 6 per minute; with rated Current and Voltage. Trip Free All E-Series Circuit Breakers will trip on overload, even when Handle is forcibly held in the ON position. Trip Indication The operating Handle moves positively to the OFF position when an overload causes the breaker to trip. Physical Number of Poles Mounting Connectors, Box Type Internal Circuit Configuration Weight Standard Colors 1-6 A 3” minimum spacing must be provided between the circuit breaker arc venting area on back connected E-Series circuit breakers and grounded obstructions. E-Series circuit breakers must be mounted on a vertical surface. Front connected E-Series circuit breakers are supplied with box type pressure connectors that accept copper or aluminum conductors as follows: 1/0-14 Copper, 1/0-12 Aluminum. Series and Switch Only, (with or without auxiliary switch). Shunt with current coils. Approximately 252 grams/pole (Approximately 9 ounces/pole) Housing-Black; Actuator - See Ordering Scheme. Environmental Designed in accordance with requirements of specification MIL PRF-55629 & MIL-STD-202G as follows: Pulse Tolerance Curves Time Delay Curves 62, 64 & 66 (100 Amps Max.) Time Delay Curves 22, 24 & 26 (100 Amps Max.) Shock Withstands 100 Gs, 6ms, sawtooth while carrying rated current per Method 213, Test Condition “I”. Vibration Withstands 0.060” excursion from 10-55 Hz, and 10 Gs 55-500 Hz, at rated current per Method 204C, Test Condition A. Moisture Resistance Method 106D, i.e., ten 24-hour cycles @ + 25°C to +65°C, 80-98% RH. Salt Spray Method 101, Condition A (90-95% RH @ 5% NaCl Solution, 96 hrs). Thermal Shock Method 107D, Condition A (Five cycles @ -55°C to +25°C to +85°C to +25°C). Operating Temperature -40° C to +85° C *Manufacturer reserves the right to change product specification without prior notice. 22www.carlingtech.com E-Series Circuit Breaker - General Specification Electrical Table Lists UL Listed (489) & CSA Certified (C22.2 No. 5) configurations & performance capabilities as a Molded Case Circuit Breaker. E SERIES TABLE A : UL489 LISTED BRANCH CIRCUIT BREAKERS VOLTAGE CIRCUIT CONFIGURATION CURRENT RATING INTERRUPTING CAPACITY (AMPS) HIGH INTERRUPTING CAPACITY WITHOUT BACKUP (AMPS) FUSE MAX. RATING FREQUENCY PHASE 80 125 DC DC ----- 0.10 - 100 0.10 - 100 5,000 5,000 50,000 10,000 125 120 240 DC 50 / 60 50 / 60 --1 1 101 - 125 101 - 125 0.10 - 30 10,000 10,000 5,000 ----10,000 240 120 / 240 120 / 240 120 / 240 240 50 / 60 50 / 60 50 / 60 50 / 60 50 / 60 1 1 1 1 3 31 - 100 0.10 - 30 31 - 100 101 - 125 0.10 - 100 5,000 5,000 5,000 10,000 5,000 10,000 ------- SERIES FULL LOAD AMPS Agency Certifications UL Recognized UL Standard 1077 Component Recognition Program as Protectors, Supplementary (Guide QVNU2, File E75596) CSA Accepted Component Supplementary Protector (Class 3215 30, File 047848 0 000) CSA Standard C22.2 No. 235 CUL Standard C22.2 Component Recognition Program as Manual Motor Controls (Guide NLRV2, File E135367) CSA Certified Circuit Breaker Molded Case (Class 1432 01, File 093910), CSA Standard C22.2 No. 5.1 - M UL Standard 1500 Protectors, Supplementary for Marine Electrical & Fuel Systems (Guide PEQZ2, File E75596) Ignition Protection TUV Certified EN60934 under License No. R72031056 VDE Certified EN60934, VDE 0642 under File No. 10537 UL Listed UL Standard 489 Circuit Breakers, Molded Case (Guide DIVQ, File E129899) www.carlingtech.com23 E-Series Handle Circuit Breaker UL Listed- Ordering Scheme E A 2 1 Series 2 Actuator B 0 4 Circuit 3 Poles 5 Auxiliary Switch 24 6 Frequency & Delay 2 ACTUATOR Handle, one per pole 3 POLES1 1 One 2Two 3Three 4Four 4 CIRCUIT2 B Series Trip (current) 5 AUXILIARY SWITCH4 0 2 3 4 without Auxiliary Switch S.P.D.T. 0.110 Q.C. Terminals S.P.D.T. 0.139 Solder Lug S.P.D.T. 0.110 Q.C. Terminals (Gold Contacts) 6 FREQUENCY & DELAY 105 12 14 16 205 22 24 26 30 32 34 DC Instantaneous DC Short DC Medium DC Long 50/60Hz Instantaneous 50/60Hz Short 50/60Hz Medium 50/60Hz Long DC, 50/60Hz Instantaneous DC, 50/60Hz Short DC, 50/60Hz Medium 5Five 6Six C3 6 7 8 9 Series Trip (voltage) S.P.D.T. 0.110 Q.C. Terminals S.P.D.T. 0.110 Q.C. Terminals (Gold Contacts) S.P.D.T. 0.187 Q.C. Terminals S.P.D.T. 0.187 Q.C. Terminals 36 DC, 50/60Hz Long 62 50/60Hz Short, Hi-Inrush 64 50/60Hz Medium, Hi-Inrush 66 50/60Hz Long, Hi-Inrush 72 DC, Short,Hi-Inrush 74 DC,Medium, Hi-Inrush 76 DC, Long, Hi-Inrush DC, 50/60Hz Short, Hi-Inrush 926 6 DC, 50/60Hz Medium, 94 Hi-Inrush DC, 50/60Hz Long, Hi-Inrush 966 7 CURRENT RATING (AMPERES) 7 CODE 7 Current Rating 1 2 A 8 Terminal 9 Actuator Color 10 Mounting/ Barriers C C 11 Maximum Application Rating 12 Agency Approval 8 TERMINAL7 1 SERIES E A 450 AMPERES 020 0.020 235 0.350 430 3.000 614 14.000 025 0.025 240 0.400 435 3.500 615 15.000 030 0.030 245 0.450 440 4.000 616 16.000 035 0.035 250 0.500 445 4.500 617 17.000 040 0.040 255 0.550 450 5.000 618 18.000 045 0.045 260 0.600 455 5.500 620 20.000 050 0.050 265 0.650 460 6.000 622 22.000 055 0.055 270 0.700 465 6.500 624 24.000 060 0.060 275 0.750 470 7.000 625 25.000 065 0.065 280 0.800 475 7.500 630 30.000 070 0.070 285 0.850 480 8.000 635 35.000 075 0.075 290 0.900 485 8.500 640 40.000 080 0.080 295 0.950 490 9.000 650 50.000 085 0.085 410 1.000 495 9.500 660 60.000 090 0.090 512 1.250 610 10.000 670 70.000 090 0.095 415 1.500 710 10.500 680 80.000 210 0.100 517 1.750 611 11.000 690 90.000 215 0.150 420 2.000 711 11.500 810 100.000 220 0.200 522 2.250 612 12.000 811 110.000 225 0.250 425 2.500 712 12.500 812 120.000 230 0.300 527 2.750 613 13.000 9128 125.000 OR VOLTAGE COIL (MIN. TRIP RATING, VOLTS)5 A06 6 DC, 5 DC A65 65 DC, 55 DC J48 48 AC, 40 AC A12 12 DC, 10 DC B25 125 DC, 100 DC J65 65 AC, 55 AC A18 18 DC, 15 DC J06 6 AC, 5 AC K20 120 AC, 65 AC A24 24 DC, 20 DC J12 12 AC, 10 AC L40 240 AC, 130 AC A32 32 DC, 25 DC J18 18 AC, 15 AC A48 48 DC, 40 DC J24 24 AC, 20 AC BACK CONNECTED (FRONT MOUNTED ONLY) MAX. RATING 1 8 10-32 Stud (All Terminals) 50 A 8 2 1/4-20 Stud (All Terminals) 125 A FRONT CONNECTED (BACK MOUNTED ONLY) MAX. RATING 3 9 Box Wire Connector (Line & Load) 100 A C10 Box Wire Connector w/ Pressure Plate (Line & Load) 100 A 4 10-32 Screw (Line & Load) 50 A 5 10-32 “Bus-Type” Screw (Line), 10-32 Screw (Load) 50 A 6 9 10-32 “Bus-Type” Screw (Line), Box Wire Connector (Load) 100 A 10 10-32 “Bus-Type” Screw (Line), Box Wire Connector F w/ Pressure Plate (Load) 100 A 7 1/4-20 Screw (Line & Load) 125 A 8 1/4-20 “Bus-Type” Screw (Line), 1/4-20 Screw (Load) 100 A 9 9 1/4-20 “Bus-Type” Screw (Line), Box Wire Connector (Load) 100 A 10 1/4-20 “Bus-Type” Screw (Line), Box Wire Connector J w/ Pressure Plate (Load) 100 A 9 ACTUATOR COLOR & LEGEND12 Actuator Color Dual ON-OFF White 1 B Black 2 D Red 3 G Green 4 J Blue 5 L Yellow 6 N Gray 7 Q Orange 8 S Legend Color Black White White White White Black Black Black 10 MOUNTING/BARRIERS BACK CONNECTED (FRONT MOUNTED ONLY) Mounting Inserts A 6-32 B ISO M3 FRONT CONNECTED (BACK MOUNTED ONLY)11 Back Mounting Foot Type Front Mounting Inserts (Optional Use) CShort 6-32 D Short ISO M3 ELong 6-32 F Long ISO M3 11 MAXIMUM APPLICATION RATING 1 120 VAC B 125 VDC, 120 A 13 C 120/240 VAC, 100 A D 240 VAC, 100 A 12 AGENCY APPROVAL UL 489 Listed & CSA Certified C UL 489 Listed, CSA Certified, & VDE Certified F Notes: 1 Standard multi-pole units identical poles except when specifying auxiliary switch (see Note 4). For mixed ratings, consult factory. VDE Certification on 1-5 poles only. 2 Series Trip construction available w/either front or back connected terminals. 3 Series Trip construction with a voltage coil is not available as a single pole unit and must be tied to a protected pole. 4 On multi-pole units, only one auxiliary switch is normally supplied mounted in the extreme right pole per Figure A. Back mounted units require special mounting provisions when auxiliary switch is specified. VDE Certification on auxilary switch codes 0, 2, 3 & 4 only. 5 Voltage Trip Coils are not rated for continuous duty. Available only with Frequency & Delay Codes 10 & 20. 6 Frequency & Delay Codes 92, 94 & 96 are not VDE Certified. 7 Current Ratings under 0.100 amps are not VDE Certified . 8 An Anti-Flash Over Barrier is supplied between poles on multi-pole units with 10-32 Stud (Terminal Code 1) or 1/4-20 Stud (Code 2) terminals per UL requirement. 9 Box Wire Connector will accept #14 through 0 AWG. copper wire or #12 through 0 AWG. aluminum wire. 10 Box Wire Connector with Pressure Plate for stranded wire, consult factory for details. 11 Back Mounted breakers can also be front mounted by utilizing the proper front panel mouning inserts normally supplied. However, terminal connections must be made prior to mounting. 12 VDE Certification requires dual (I-O , ON-OFF) markings on all handles. 13 Not available with VDE Certification. 24www.carlingtech.com E-Series Handle Circuit Breaker - Circuit & Terminal Diagrams Notes: 1 All dimensions are in inches [millimeters]. 2 Tolerance ±.020 [.51] unless otherwise specified. 3 0-50 amps: 10-32 & M5 Studs .625±.062/15.88±1.574 long. 4 51-120 amps: 1/4-20 & M6 Studs .750±.062/19.05±1.574 long. www.carlingtech.com25 E-Series Handle (Back Connected) Circuit Breaker - Form & Fit Drawings Notes: 1 1/4 -20 stud terminal in Series Trip circuit configuration shown. 2 A 3” min spacing must be provided between the circuit breaker arc venting area of back connected E-Series circuit breaker and grounded obstructions. 3 All dimensions are in inches [millimeters]. 4 Tolerance ±.020 [.51] unless otherwise specified. 5 Circuit breakers must be mounted on vertical surface. 26www.carlingtech.com E-Series Handle (Front Connected) Circuit Breaker - Form & Fit Drawings Notes: 1 All dimensions are in inches [millimeters]. 2 Tolerance ±.020 [.51] unless otherwise specified. 3 Box wire connector terminal in Series Trip circuit configuration shown. 4 Circuit breakers must be mounted on vertical surface. www.carlingtech.com27 F-Series Circuit Breaker The F-Series hydraulic/magnetic high amperage circuit breakers are designed to handle high current applications in extremely hot and/or cold locations. Due to its time-proven hydraulic/magnetic design, the F-Series load sensing mechanism is insensitive to changes in ambient or enclosure temperature, providing a consistent trip point over temperatures ranging from -40°C to +85°C. Additionally, the F-Series circuit breakers come with a choice of overload time delays, making them ideal for critical applications having inductive loads. Further, the F-Series breakers are available up to 700A and an optional 25 millivolt metering shunt construction provides a safe method for monitoring current flowing through the breaker by simply connecting a meter with light gauge wire to the appropriate terminals located on the shunt housing at the rear of the breaker. Applications can be customized by measuring and displaying percentage of current, watts or safe/danger zones. Features: AC ratings to UL 489 DC voltage ratings up to 700A with metering shunt section Consistent trip point over temperatures ranging from -40°C to +85°C Optional 25 millivolt metering shunt construction 28www.carlingtech.com F-Series Circuit Breaker - General Specification Electrical Mechanical Maximum Voltage 125VDC Current Ratings Standard current coils: 100, 125, 150, 175, 225, 250 amps. 300, 350, 400, 500, 600, 700 amps available as parallel pole construction. Auxiliary Switch Rating SPDT; 10.1 Amps @ 250VAC, 1.0 Amps @ 65VDC, 0.5 Amps @ 80VDC 0.1 Amps @ 125VAC (with gold contacts). Insulation Resistance Minimum: 100 Megohms at 500 VDC Dielectric Strength 1960 VAC, 50/60 Hz for one minute between all electrically isolated terminals, except 2500 VAC for one minute between alarm/aux. switch and main terminals with contacts in open and closed position. F-Series circuit breakers comply with the 8mm spacing & 3750VAC 50/60 Hz dielectric requirements from hazardous voltage to operator accessible surfaces, between adjacent poles and from main circuits to auxilary circuits per Publications EN 60950 and VDE 0805. Resistance, Impedance Values from Line to Load Terminal - based on Series Trip Circuit Breaker. Endurance 4000 ON-OFF operations with rated Current & Voltage & 4000 operations with no load (8000 operations total) @ 5 per minute. Parallel Pole construction: 1000 operations with rated Current and Voltage @ 5 per minute. Trip Free All F-Series Circuit Breakers will trip on overload, even when the actuator is forcibly held in the ON position. Trip Indication The operating actuator moves positively to the OFF position when an overload causes the circuit breaker to trip. RESISTANCE PER POLE VALUES from Line to Load Terminals (Values Based on Series Trip Circuit Breaker) Physical Number of Poles 1 - 3 Poles Note: Ratings over 250 Amps only available with parallel pole. Internal Circuit Config. Series (with or without auxiliary switch), Switch Only (with or without auxiliary switch). Available Accessories Factory installed: DC Current Metering Shunt (25 mV @lr) Weight Varies depending on construction. Consult factory. Standard Colors Housing - Black; Actuator- Black or White with contrasting ON-OFF legend. Environmental Designed and tested in accordance with requirements of specification MIL-PRF-55629 & MIL-STD-202 as follows: Shock Withstands 100 Gs, 6ms, sawtooth while carrying rated current per Method 213, Test Condition “I”. Instantaneous and ultra-short curves tested @ 90% of rated current. Vibration Withstands 0.060” excursion from 10-55 Hz, and 10 Gs 55-500 Hz, at rated current per Method 204C, Test Condition A. Instantaneous and ultrashort curves tested at 90% of rated current. Moisture Resistance Method 106D; ten 24-hour cycles @ + 25°C to +65°C, 80-98% RH.56 days @ +85°C, 85% RH. Salt Spray Method 101, Condition A (90-95% RH @ 5% NaCl Solution, 96 hrs). Thermal Shock Method 107D, Condition A (Five cycles @ -55°C to +25°C to +85°C to +25°C). Operating Temperature -40° C to +85° C *Manufacturer reserves the right to change product specification without prior notice. www.carlingtech.com29 F-Series Circuit Breaker - General Specification Table A: Lists UL Tables Listed (489)and CSA Certified (C22.2 N0. 5.1-M) configurations and performance Electrical capabilities as a Molded Case Circuit Brekaer Table A: Lists UL Listed (489)and CSA Certified (C22.2 N0. 5.1-M) configurations and performance capabilities as a Molded Case Circuit Breaker F SERIES TABLE A : UL489 LISTED BRANCH CIRCUIT BREAKERS VOLTAGE CIRCUIT CONFIGURATION MAX RATING FREQUENCY PHASE 125 SERIES CURRENT RATING INTERRUPTING CAPACITY (AMPS) FULL LOAD AMPS UL / CSA 1 - 3 POLES TUV 2 1 or 2 POLES DC --- 50 - 250 50,000 25,000 1 50 / 60 50 / 60 1 1 100 - 250 100 - 250 10,000 10,000 ----- 208Y / 120 50 / 60 3 100 - 250 10,000 --- 120 / 240 277 Notes: NOTES: 1 120/240V rating available in 2 or 3 poles. In a 3 pole construction the center pole is Neutral. 1.2 120/240V ratingareavailable 2AC orratings. 3 poles. In a 3 pole construction the center pole is Neutral. TUV constructions not availablein with 2. TUV constructions are not available with AC ratings. Table B: Lists UL Listed configurations and performance capabilities as Circuit Breakers for use in Communications Equipment (Guide DITT, File E189195), under UL489A Agency Certifications UL Listed UL 489 UL 489A Circuit Breakers , Molded Case (Guide DIVQ, File E129899) Complies with the requirements of the CSA Standard for Molded Case Circuit Breakers, CANCSA- C22.2 No. 5.1 –M Circuit Breakers for Use in Communications Equipment (Guide DITT, File E189195) TUV Certified IEC 60947-2 Low Voltage Switch gear and Control Gear under TUV License No. R72031058 30www.carlingtech.com F-Series Handle Circuit Breaker - Ordering Scheme F A 2 1 Series 2 Actuator B 0 4 Circuit 3 Poles 14 5 Aux/Alarm Switch 6 Frequency & Delay 1 SERIES F Actuator Color White Black Handle, one per pole Mid-Trip Handle, one per pole Mid-Trip Handle, one per pole & Alarm Switch 3 POLES 1 2 One 3 810 912 815 917 Switch Only (no coil) Series Trip (current) Series Trip (voltage) 5 w/o Aux Switch S.P.D.T., 0.110 Q.C. Term. S.P.D.T., 0.139 Solder Lug S.P.D.T., 0.110 Q.C. Term. (Gold Contacts) S.P.S.T., 0.093 Q.C. Term. (Gold Contacts) S.P.S.T., 0.139 Solder Lug S.P.S.T., 0.110 Q.C. Term. (Gold Contacts) DC 50/60Hz, Switch Only DC Instantaneous DC Ultra Short DC Short AMPERES 100.00 125.00 150.00 175.00 8 S.P.S.T., 0.187 Q.C. Terminals 9 S.P.D.T., 0.187 Q.C. Terminals. 6 A S.P.S.T., 0.093 Round QC Terminals. B6 S.P.D.T., 0.093 Round Q.C. Terminals. 14 16 22 24 26 DC Medium DC Long AC Short AC Medium AC Long 820 200.00 922225.00 825 250.00 8308 300.00 8358350.00 8408 400.00 8458 450.00 8508 500.00 8608 600.00 8708 700.00 OR VOLTAGE COIL (VOLTS, MIN. TRIP RATING)7 CODE AMPERES A06 6 DC, 5 DC A12 12 DC, 10 DC A18 18 DC, 15 DC 8 TERMINAL 12 Agency Approval Dual Marking Color 1Black 2White Back Mounting Inserts 10-32 screw clearance holes 10-32 screw clearance holes Three 7 CURRENT RATING (AMPERES) CODE B G 11 Max. App. Rating 11 MAXIMUM APPLICATION RATING 6 FREQUENCY & DELAY 03 107 11 12 10 Mounting I-O ON-OFF AB CD Front Mounting Inserts A 10-32 B ISO M5 Parallel Pole Construction: M3,4 Series Trip (Current) with Metering Shunt N3,4 Switch Only with Metering Shunt Series Trip (Current) P3 Switch Only Q3 5 AUXILIARY/ALARM SWITCH 0 2 3 4 5 6 7 9 Actuator Color 10 MOUNTING Two 4 CIRCUIT A 1 B C2 1 2 A 8 Terminal 9 ACTUATOR COLOR & LEGEND12,13 2 ACTUATOR A S T 820 7 Current Rating A24 24 DC, 20 DC A32 32 DC, 25 DC A48 48 DC, 40 DC Back Connected (Front Mounted Only) 19 3/8-16 Stud 214 3/8-16 Screw, Line & Load 14 5 3/8-16 Short Stud Front Connected (Back Mounted Only)11 3 Box Wire Connector, Line & Load 414 3/8-16 Screw, Line & Load A65 65 DC, 55 DC B25 125 DC, 100 DC J06 6 AC, 5 AC VOLTAGECURRENT B 125 VDC 700A C15 120/240250A F 277 VAC 250A 716 120/208 VAC 250A 12 AGENCY APPROVAL A G J T No approvals UL 489 Listed & CUL Certified UL 489 Listed, CUL Certified & TUV Certified UL489A (Telecom) Listed Notes: 1 For 100 to 250 amps, select Current Code 825. For 300-400 amps, select Current Code 840. For 450-700 amps, select Current Code 870. 2 Available with Frequency and Delay code 10 or 20 only, and are not rated for continuous duty. Delay 10 and 20 are only available with voltage coils. 3 3 Codes M, N, P & Q (Parallel Poles) are supplied with factory installed Bus Bar on Line and Load. 4 4 Metering terminals are female pin type, ref. Molex part number 02-09-1101, model 1189-T. 5 Auxiliary Switch breakers are only available with Series Trip and Switch Only circuits. On multi-pole breakers, one Auxiliary Switch is supplied, mounted in the extreme right pole per figure A. Back-Mounted breakers require special mounting provisions when an Auxiliary Switch is specified. 6 Available with parallel pole construction (circuit codes P and Q, and breakers with circuit codes M and N). 7 Frequency and delay code 10 is only available with Voltage Coils. Voltage Coils are not rated for continuous duty. 8 Ratings over 250 amps are only available with Agency Approval code T (UL489A) and are Parallel Pole configuration (circuit codes M, N, P and Q.) 300-450 amp ratings are available on two pole breakers. 500-700 amp ratings are available on three pole breakers. 9 Per UL requirement, an “Anti-Flash Over Barrier” is supplied between poles on multipole breakers with 3/8 - 16 stud terminals (Terminal Code 1) 10 Front connected breakers can also be front mounted by utilizing the supplied front panel mounting inserts. Terminal connections must be made before mounting. 11 Box Wire connector will accept #6 through 250 MCM copper wire. 12 Agency codes G & T must have ON-OFF or dual legends. Agency code J must have dual legend. 13 Other colors available. Consult factory. 14 Terminals 2,4 & 5 are shipped without terminal hardware. 15 2 or 3 Pole Circuit Breaker Required for 120/240 VAC Rating. 16 3 Pole Circuit Breaker Required for 120/208 VAC Rating. Max Rating 250A 700A 250A Max Rating 700A 700A www.carlingtech.com31 F-Series Handle Circuit Breaker - Circuit & Terminal Diagrams Notes: 1 All dimensions are in inches [millimeters]. 2 Tolerance ±.020 [.51] unless otherwise specified. 32www.carlingtech.com F-Series Handle Circuit Breaker - Circuit & Terminal Diagrams Notes: 1 All dimensions are in inches [millimeters]. 2 Tolerance ±.020 [.51] unless otherwise specified. www.carlingtech.com33 F-Series Handle Circuit Breaker - Circuit & Terminal Diagrams Notes: 1 All dimensions are in inches [millimeters]. 2 Tolerance ±.020 [.51] unless otherwise specified. 34www.carlingtech.com F-Series Handle Circuit Breaker - Form & Fit Diagrams Notes: 1 All dimensions are in inches [millimeters]. 2 Tolerance ±.020 [.51] unless otherwise specified. www.carlingtech.com35 F-Series Handle Circuit Breaker - Form & Fit Diagrams Notes: 1 All dimensions are in inches [millimeters]. 2 Tolerance ±.020 [.51] unless otherwise specified. 36www.carlingtech.com F-Series Handle Circuit Breaker - Form & Fit Diagrams F-Series breakers are available up to 700A, and are also available with a 25 millivolt metering shunt construction. This optional construction provides a safe method for monitoring current flowing through the breaker by simply connecting a meter with light gauge wire to the appropriate terminals located on the shunt housing at the rear of the breaker. You can customize the application by measuring and displaying percentage of current, watts or safe/danger zones. Notes: 1 All dimensions are in inches [millimeters]. 2 Tolerance ±.020 [.51] unless otherwise specified. www.carlingtech.com37 F-Series Circuit Breaker - Delay Curves 11 12 14 16 22 24 26 Short - AC 22 No Trip No Trip No Trip No Trip No Trip No Trip No Trip .013 - .125 .475 - 10.0 10.0 - 110 110 - 1000 .700 - 12.0 10.0 - 160 50.0 - 700 AC .010 - .070 .008 - .032 .275 - 2.80 .140 - .850 6.00 - 40.0 60.0 - 400 .350 - 4.00 6.00 - 60.0 32.0 - 350 2.50 - 15.0 22.0 - 150 .130 - 1.30 .220 - 20.0 10.0 - 90.0 .005 - .020 .004 - .020 .030 - .190 .015 - .125 .004 - .020 .010 - .050 .008 - .038 .500 - 3.00 4.00 - 25.0 .027 - .220 .300 - 3.00 1.50 - 15.0 .180 - 1.00 1.00 - 5.50 .008 - .130 .050 - 1.30 .500 - 7.00 .010 - .280 .008 - .080 .008 - .390 .004 - .045 .005 - .060 .006 - 2.00 .006 - .020 Ultrashort - DC .010 - 1.80 .004 - .090 .007 - .500 .020 - 3.00 DC TRIP TIME IN SECONDS TRIP TIME IN SECONDS F SERIES 50/60 HZ SHORT CURVE NO. 22 Short - DC PERCENT OF RATED CURRENT PERCENT OF RATED CURRENT TRIP TIME IN SECONDS F SERIES 50/60 HZ MEDIUM CURVE NO. 24 TRIP TIME IN SECONDS Medium - AC 24 Medium - DC PERCENT OF RATED CURRENT Long - AC 26 Long - DC PERCENT OF RATED CURRENT TRIP TIME IN SECONDS TRIP TIME IN SECONDS F SERIES 50/60 HZ LONG CURVE NO. 26 TRIP TIME IN SECONDS PERCENT OF RATED CURRENT 38www.carlingtech.com Literature Carling also offers several catalogs, covering all our circuit protection and control lines. This complete line of catalog information, which includes general specs, circuit and terminal drawings, form & fit drawings and complete ordering information, is available in printed form, as a downloadable PDF documents from our website. Please visit our website at www.carlingtech.com, scan the QR codes below or contact any one of our locations to request the following literature: Switches & Controls Switches and Controls Rocker, Toggle, Pushbutton & Rotary Hydraulic Magnetic Circuit Protection Hydraulic/Magnetic Circuit Breakers This Catalog details the complete line of Switches and Controls including Rocker, Toggle, Pushbutton, and Rotary style switches. This Catalog highlights the full line of Hydraulic Magnetic Circuit Breakers. Breakers from .02 to 700 amps with UL, CSA, VDE, TUV, UL489, UL489A, UL1500 certifications. Thermal’s GFCI’s Thermal Circuit Breaker Ground Fault Circuit Protection Reliable, Cost-effective Circuit Protection This Catalog focuses on the whole line of Thermal Circuit Breakers. Carling offers a variety of 3 to 60 amp, lighted and nonlighted, rocker actuator and push-to-reset push button thermal circuit breakers with UL, CUL, CE, UL1500/ISO 8846 certifications This Catalog features the entire line of Ground Fault Circuit Breakers. GFCI breakers range from .10 to 50 amps, and are well suited for Marine industries use. www.carlingtech.com39 Literature On-Off Highway ON–OFF Highway Switches & Controls CATALOG Marine Marine Switches, Circuit Breakers & ELCI/GFCIs The On-Off Highway Catalog details the list of applicable products for the transportation industry. These include the Carling’s V, W, L, S and N-Series Switches. The Marine Catalog highlights the list of applicable products for the marine industry including switches, circuit breakers, GFCI’s, and the OctoPlex system. Military Renewable Energy Military Grade Renewable Energy Circuit Breakers and Disconnects COTS SWITCHES & CIRCUIT BREAKERS The Military Catalog focuses on the list of applicable products for military uses. These comprise of sealed rocker, toggle and miniature switches as well as circuit breakers The Renewable Energy Catalog features the list of applicable products for eco-friendly sources of energy. These are the Carling’s CX, C, G, E, and F-Series circuit breakers. Telecom/Datacom Carlingtech.com Telecom/Datacom Circuit Protection CATALOG This catalog focuses on the list of applicable products for the Telecom-Datacom industry. This features Carling’s L, CX, A, B, C, F and M-Series circuit breakers. Visit us online for complete products and company information. 40www.carlingtech.com Worldwide Headquarters Carling Technologies, Inc. 60 Johnson Avenue Plainville, CT 06062 (860) 793-9281, fax: (860) 793-9231 e-mail: [email protected] www.carlingtech.com East Region Sales Office, CT [email protected] Midwest Region Sales Office, IL [email protected] West Region Sales Office, CA [email protected] Europe/Middle East/Africa Headquarters Carling Technologies LTD 4 Airport Business Park, Exeter Airport, Clyst Honiton, Exeter, Devon, EX5 2UL, UK Int + 44 1392-364422 • Fax: Int + 44 1392-364477 Email: [email protected] GmbH, Germany • [email protected] SAS, France • [email protected] Asia-Pacific Headquarters Carling Technologies, Asia-Pacific Ltd. Kowloon, Hong Kong Int + 852-2737-2277, fax: Int + 852-2736-9332 e-mail: [email protected] Asia-Pacific Ltd., Shanghai, China [email protected] Asia-Pacific Ltd., Japan [email protected] Pune, India [email protected] Kaohsiung, Taiwan [email protected] RE_C_06_2013