GFCI/ELCI Circuit Protection Transforming Customer Needs into Customer Solutions Carling Technologies Sales, Service and Engineering teams do much more than manufacture electrical components, they engineer powerful solutions! By working closely with a customer’s product team and understanding the requirements of the specific application, Carling’s product experts can tailor switching and circuit protection solutions to meet any customer’s needs—cost effectively. Since the company was founded in 1920, there are few products that Carling Technologies hasn’t turned “ON” and fewer industries that haven’t turned to Carling for solutions. With four ISO registered manufacturing facilities and technical sales offices worldwide, Carling now ranks among the world’s largest, privately owned manufacturers of hydraulic magnetic circuit breakers, thermal circuit breakers, electrical switches, electronic switches, miniature switches, power distribution centers, digital switching systems and electronic controls. Globally, there are over 2,000 employees working for Carling, providing solutions to customers’ application needs with innovation, value, and world-class service for both standard and custom products. Carling’s breadth and depth of standard product offerings gives customers literally millions of configuration choices to meet the demands of its Strategic Markets: Marine M ilitary Renewable Energy Telecom/Datacom Transportation Additional markets served by Carling products include: Audio Visual, Commercial Food Equipment, Commercial HVAC, Floor Care, Generators, Industrial Control, Kitchen & Small Appliances, Security Systems, Test & Measurement equipment, among others. If the standard product does not meet the application requirements, the engineering team at Carling has the expertise to customize solutions faster and more creatively thanks in measure to over ninety years of experience as an innovative company that manufactures a diverse range of products. The Carling Sales, Service and Engineering teams work closely with the customer’s engineering team to advance a custom project from initial concept to final design and product release, respecting both quality and cost through out the process. With extensive field knowledge and resources available, Carling Technologies can ensure that the products created for the customer are of superior quality from the start, thus avoiding costly secondary operations or modifications. Carling’s commitment to excellence consistently delivers “Quality by Design,” the company mission. Carling has an extensive network of Sales Representatives and Distributors to assist with Carling products, or contact a Carling Technologies’ Technical Sales Representative to design innovative, cost-effective, quality engineered solutions that exceed the tough demands of today’s applications. ii www.carlingtech.com Table of Contents 2 3 GFCI Circuit Breaker - Selector Guide PB–Series General Specifications 12 22 Dimensional Specifications Ordering Scheme Wiring Diagrams Panel Seal Ordering Scheme Panel Seal Drawings PC–Series General Specifications Dimensional Specifications Ordering Scheme Wiring Diagrams Dimensions Panel Seal Ordering Scheme Panel Seal Drawings Time Delay Curves PD–Series General Specifications Ordering Scheme Circuit & Terminal Diagrams GFCI/ELCI This catalog features Carling Technologies’ current line of GFCIs/ELCIs products, which offer maximum equipment protection against overload and short circuits. Carling’s Equipment leakage circuit breakers function as hydraulic/magnetic circuit breakers, offering customized overload and short circuit protection. In addition, they sense and guard against faults to ground using innovative electronics technologies. With the exception of small amounts of leakage, the current returning to the power supply will be equal to the current leaving the power supply. If the difference between the current leaving and returning through the earth leakage circuit breaker exceeds the leakage sensitivity setting, the breaker trips and its LED illuminates. The LED gives a clear indication that the trip occurred as a result of leakage to ground. This protection helps prevent serious equipment damage and fire. Typical Applications: Marine www.carlingtech.com 1 GFCI Circuit Breaker Selector Guide PB-SERIES 2 PC-SERIES PD-SERIES 1-3 poles, 3rd pole switched neutral 1-poles (1 Circuit Breaker + 1 GFCI Sensor Module), 120V 2-pole (2 Circuit Breakers + 1 GFCI Sensor Module), 120/240V or 120V with Neutral Break. 2-pole (2 Circuit Breakers + 1 GFCI Sensor Module), 240VAC 3-pole 120/240V with Neutral Break (Sensor module has 2 pole width) 1-3 poles, with switched or unswitched neutral options Handle, Rocker, Flat Rocker actuators Handle, Rocker, Flat Rocker, Push-to-reset Handle, with handle guard option 30mA & 6mA 30mA & 6mA 7-100 milliamps LEAKAGE CURRENT TRIP LEVEL For 30mA leakage trip: ≤ 22.2mA, shall not trip 30mA, shall trip within .10 seconds, complying with UL-1053 & ABYC E11. For 6mA leakage trip: ≤25ms, complying with UL-943. For 30mA leakage trip: ≤ 22.2mA, shall not trip 30mA, shall trip within .10 seconds, complying with UL-1053 & ABYC E11. For 6mA leakage trip: ≤25ms, complying with UL-943. 300 ms Max. @ 100%, 40ms Max. @ 500% of must trip leakage current LEAKAGE CURRENT TRIP TIME 0.10 - 30 amps @ 120/240VAC 0.10 - 50 amps @ 120/240VAC - 240VAC 120VAC, Single Phase 120/208VAC, Single Phase 120/240VAC, Single Phase 208/240VAC, Three Phase 480Y/277VAC, Three Phase 5,000 amps 5,000 amps 5,000A @ 120/208 VAC; 120/240VAC, Single phase 2,000A @ 208/240, Three phase 2,000A @ 480Y/277VAC, Three phase Series Trip Series Trip Series Trip .250 Quick Connect Tabs 8-32, 10-32, M4,M5 screw with upturned lugs 8-32, 10-32, M4,M5 screw, Bus Type 10-32 Threaded Stud Front Connected Box Lug w/ pressure plate TERMINAL OPTIONS Front Panel Front Panel Front Mounted or Din Rail Mounted MOUNTING METHOD -35° C to +65° C -35° C to +65° C -10°C to 60°C UL489, CSA, UL1077, UL1500 UL943, UL1053, UL1500 UL Recognized, CSA, TUV NUMBER OF POLES ACTUATOR STYLE MAXIMUM CURRENT & VOLTAGE RATINGS MAXIMUM INTERRUPTING CAPACITY AVAILABLE CIRCUITS OPERATING TEMPERATURE AGENCY APPROVALS www.carlingtech.com PB-Series - Introduction PB-Series GFCI/ELCI & Panel Seal The PB-Series utilizes the hydraulic magnetic principle which provides precise operation and performance even when exposed to extremely hot and/or cold application environments. The new PB-Series, AC Residual Current Circuit Breaker with Overcurrent Protection (RCBO), combines the ground fault protection of a GFCI with the familiar overcurrent tripping characteristics of a normal circuit breaker. These precision mechanisms are temperature stable and are not adversely affected by temperature changes in their operating environment. As such, derating considerations due to temperature variations are not normally required, and heat-induced nuisance tripping is avoided. Features: Overload, short circuit and ground fault protection in a single package Handle or rocker style actuators Wiping Contacts - Mechanical linkage with two-step actuation – cleans contacts, provides high, positive Benefits: Increases safety around boats and marinas contact pressure & longer contact life. A trip-free mechanism, a safety feature which makes it Protects against electrical shock hazards in areas near water impossible to manually hold the contacts closed during Protects against defects in wires & conductors Reduces fire and shock hazards from defects in permanently overload or fault conditions. A common trip linkage between all poles, another safety installed appliances such as water heaters, battery chargers, feature, ensures that an overload in one pole will trip all lighting fixtures, etc. Detects lower level ground faults which do not trip ordinary adjacent poles. Front panel mounting circuit breakers, but can lead to fires, and shock hazards for Integral push-to-test button boating occupants www.carlingtech.com 3 PB-Series Circuit Breaker - General Specifications Electrical Tables Mechanical RESISTANCE, IMPEDANCE VALUES Table A: UL Listed configurations and performance capabilities Endurance from Line to Load Terminals as Circuit Breakers. (Values Based on Series Trip Circuit Breaker) Trip Free 1000 (AMPS) HERTZ VOLTS 100 Electrical Maximum Voltage 120/240VAC 60 Hz 10 Current Ratings Standard current coils: 0.100, 0.250, 0.500, 0.750, 1.00, 2.50, 5.00, 7.50, 10.0, 15.0, 20.0, 25.0 O & 30.0 amps. Other ratings 1 H available, see ordering scheme. M Insulation Resistance Minimum of 100 Megohms at 500 S VDC. Dielectric Strength 0.1 UL, CUL - 1500 V 60 Hz for one minute between all electrically isolated terminals. PB-Series circuit breakers comply with the 0.01 8mm spacing and 3750V 60 Hz dielectric requirements from hazardous voltage to operator accessible surfaces and between 0.001 adjacent 0.01 0.1 poles 1 10 RESISTANCE, IMPEDANCE VALUES Impedance from Line to Load Terminals Values from Line to Load Terminal. (Values Based on Series Trip Circuit Breaker) 1000 100 Ampere Rating CURRENT (AMPS) TOLERANCE (%) 0.100 - 5.0 ± 15% 20.1 - 30.0 ± 35% 5.1 - 20.0 10 ± 25% FIGURE 1 Pulse Tolerance Curve 1 Ir 0.1 60 Hz 1/2 Cycle Inrush Pulse Tolerance Multiple of Rated Current O H M S AMPERE RATING 0.01 Time Delay Curves 22, 24, 26 12x t 0.001 0.01 0.1 1 10 100 AMPERE RATING 4.165 8.33 16.67 Time in Milliseconds Leakage To Ground CURRENT (AMPS) TOLERANCE (%) 0.100 - 5.0 ± 15% 5.1 - 20.0 ± 25% Standard Must Trip 120/240VAC 60 Hz FIGURE 1 Leakage Current Ratings 5 & 30 milliamps. 5± 1mA for UL943, other leakage ratings test to UL1053. For other ratings, consult factory. Trip Time 300 ms Max. @ 100%, 40ms Max. @ 500% of must trip leakage current. Test Button On unit face along side of actuator. 20.1 - 30.0 ± 35% 10,000 ON-OFF operations @ 6 per minute; with rated Current & Voltage. All PB-Series Circuit Breakers will trip on overload or ground fault, even when Handle is forcibly held in the ON position. Trip Indication The operating Handle moves positively to the OFF position when an overload or ground fault causes the breaker to trip. Physical Number of Poles 1 - 3 poles, where the third pole is neutral Internal Circuit Config. Series Trip Weight Approximately 65 grams/pole. (2.32 ounces/pole.) Standard Colors Housing- Black; Actuator - See Ordering Scheme. Environmental Designed and tested in accordance with requirements of specification MIL-PRF- 55629 and MIL-STD-202 as follows: Shock Withstands 100 Gs, 6ms, sawtooth while carrying rated current per Method 213, Test Condition “I”. Ultra- 100 short curves tested @ 90% of rated current. Vibration Withstands 0.060” excursion from 10-55 Hz, and 10 Gs 55-500 Hz, at rated current per Method 204C, Test Condition A. Instantaneous and ultrashort curves tested at 90% of rated current. Moisture Resistance Method 106D, i.e., ten 24-hour cycles @ + 25°C to +65°C, 80-98% RH. Salt Spray Method 101, Condition A (90-95% RH @ 5% NaCl Solution, 96 hrs). Thermal Shock Method 107D, Condition A (Five cycles @ -55°C to +25°C to +85°C to +25°C). Operating Temperature -35° C to +65° C Corrosion Tested per UL943 FMG Test. 3 weeks @ 30°C 75% RH, 100ppb H2S, 20ppb CI2, 200ppb NO2 Agency Certifications UL Listed UL Standard 489 Circuit Breakers, Molded Case, (Guide DIVQ, File E129899) UL Standard 1077 Supplementary Protectors UL Standard 943 Class A Ground Fault Circuit Interrupters UL Standard 1053 Ground Fault Sensing and Relaying Equipment *Manufacturer reserves the right to change product specification without prior notice. 4 www.carlingtech.com PB-Series – Ordering Scheme PB A 1 Series B A 3 Circuit 2 System Voltage/Poles 4 Actuator 24 5 Frequency & Delay 1 SERIES PB 2 SYSTEM VOLTAGE / POLES A 120 VAC single phase, one pole B 120/240 VAC single phase, two pole C 120/240 VAC single phase with switched neutral, three pole D 120 VAC two pole with switched neutral 3 CIRCUIT B Series Trip (Current) 4 ACTUATOR1 Handle A one per pole B one per multipole unit Two Color Curved Visi-Rocker C Indicate ON, vertical legend D Indicate ON, horizontal legend F Indicate OFF, vertical legend G Indicate OFF, horizontal legend Single Color Curved Rocker J Vertical legend K Horizontal legend Two Color Flat Visi-Rocker 1 Indicate OFF, vertical legend 2 Indicate OFF, horizontal legend Single Color Flat Rocker 3 Vertical legend 4 Horizontal legend 620 6 Current Rating 2 B A 7 Terminal 8 Actuator Color 7 TERMINAL2 13 Push-On 0.250 Tab (Q.C.) 2 Screw 8-32 w/upturned lugs 3 Screw 8-32 (Bus Type) 4 Screw 10-32 w/upturned lugs 5 Screw 10-32 (Bus Type) A G 9 Mounting/ Barriers B C E H 10 Trip Level 11 Agency Approval Screw M5 w/upturned lugs Screw M4 w/upturned lugs Screw M4 (Bus Type) Screw M5 (Bus Type) 8 ACTUATOR COLOR & LEGEND HandleRocker Actuator Color Actuator Color I-O ON-OFF Dual Single Visi-Rocker White A B 1Black White Black C D 2White N/A Red F G 3White Red Green H J 4White Green Blue K L 5White Blue Yellow M N 6Black Yellow Gray P Q 7Black Gray Orange R S 8Black Orange 9 MOUNTING/BARRIERS MOUNTING STYLE Threaded Insert, 2 per pole A 6-32 X 0.195 inches B ISO M3 x 5mm BARRIERS yes yes 10 LEAKAGE CURRENT TRIP LEVEL - MAX. TRIP CURRENT A 5 MA (CLASS A GFCI)3,4,5 E 30 MA (ELCI) 11 AGENCY APPROVAL G UL489 Listed, CSA Certified C UL1077 I UL1077/UL1500 Ignition Protected, CSA Certified6 5 FREQUENCY & DELAY 22 60Hz Short 24 60Hz Medium 26 60Hz Long 6 CURRENT RATING (AMPERES) CODE AMPERES 210 0.100 215 0.150 220 0.200 225 0.250 230 0.300 235 0.350 240 0.400 2450.450 250 0.500 255 0.550 260 0.600 265 0.650 270 0.700 275 0.750 280 0.800 285 290 295 410 512 415 517 420 522 425 527 430 435 440 445 0.850 0.900 0.950 1.000 1.250 1.500 1.750 2.000 2.250 2.500 2.750 3.000 3.500 4.000 4.500 www.carlingtech.com 450 455 460 465 470 475 480 485 490 495 610 710 611 711 612 5.000 5.500 6.000 6.500 7.000 7.500 8.000 8.500 9.000 9.500 10.000 10.500 11.000 11.500 12.000 712 613 614 615 616 617 618 620 622 624 625 630 12.500 13.000 14.000 15.000 16.000 17.000 18.000 20.000 22.000 24.000 25.000 30.000 Notes: 1 Actuator Code: A: Handle tie pin spacer(s) and retainers provided unassembled with multi-pole units. B: Handle location as viewed from front of breaker: 2 pole - left pole 3 pole - center pole 2 Screw Terminals are recommended on ratings greater than 20 amps. 3 Available with leakage current trip level - Max trip current code E, and agency approval C. 4 6mA per UL943, available with agency approval code G. 5 30mA per UL1053, available with agency approval codes C & G. 6 UL1500 only available with 30MA trip level. 5 PB-Series – Dimensional Specifications INDICATE "ON" 1.515 MAX [38.48] 3.03 [76.9] INDICATE "OFF" AND SINGLE COLOR LINE .21 [5.3] 1.25 [31.6] TEST LOAD 2.17 [55.0] LOAD 1-POLE 120 VAC VERSION TEST LINE SCALE 0.500 #6-32/M3 MOUNTING INSERTS 1.88 [47.8] LINE TERMINAL 2.265 MAX [57.53] 1.660 [42.16] 2.58 [65.6] TEST 2.37 [60.2] +.020 1.500 -.000 +.50 38.10 -.00 [ .375 [9.53] .39 [9.9] CURRENT TRANSFORMERS LOAD TERMINAL 1.260 [32.00] GFCI NEUTRAL WIRE 2-POLE 120/240 VAC VERSION .20 [5.1] ] .750 TYP [19.05] 1.660 [42.16] SCALE 0.500 +.020 2.250 -.000 +.50 57.15 -.00 [ Ø .156 TYP [3.96] ] PANEL CUTOUT NEUTRAL BREAK POLE 3.015 MAX [76.58] .750 TYP [19.05] TEST 2-POLE 120/240 VAC WITH NEUTRAL BREAK Notes: 1 All dimensions are in inches [millimeters]. 2 Tolerance ±.020 [.51] unless otherwise specified. 6 www.carlingtech.com PB-Series – Dimensional Specifications Notes: 1 All dimensions are in inches [millimeters]. 2 Tolerance ±.020 [.51] unless otherwise specified. www.carlingtech.com 7 PB-Series – Wiring Diagrams 120VAC without Switched Neutral 120VAC with Switched Neutral SYSTEM NEUTRAL SYSTEM NEUTRAL GFCI MODULE PIGTAIL GFCI MODULE PIGTAIL LOAD HOT LOAD NEUTRAL LOAD HOT LINE/SOURCE (HOT) LINE/SYSTEM NEUTRAL LINE/SOURCE (HOT) 120 VAC LOAD 120 VAC LOAD AC SOURCE AC SOURCE 120 VAC WITH SWITCHED NEUTRAL 120 VAC WITHOUT SWITCHED NEUTRAL 120 VAC WITH SWITCHED NEUTRAL 120 VAC WITHOUT SWITCHED NEUTRAL 120/240VAC with Switched Neutral 120/240VAC without Switched Neutral SYSTEM NEUTRAL SYSTEM NEUTRAL GFCI MODULE PIGTAIL GFCI MODULE PIGTAIL LOAD HOT 1 LINE/SOURCE 1 120 VAC LOAD 120 VAC LOAD LOAD HOT 2 LINE/ SOURCE 2 LOAD HOT 1 LOAD NEUTRAL LINE/SYSTEM NEUTRAL 120 VAC LOAD 120 VAC LOAD LOAD HOT (2) LINE/ SOURCE (2) LINE/SOURCE (1) 240 VAC LOAD 240 VAC LOAD AC SOURCE 120 VAC WITH SWITCHED NEUTRAL 120/240 VAC WITH SWITCHED NEUTRAL 8 AC SOURCE 120 VAC WITHOUT SWITCHED NEUTRAL 120/240 VAC WITHOUT SWITCHED NEUTRAL www.carlingtech.com PB-Series – Panel Seal Ordering Scheme 8 PB 1 Type Number 2 Series 1 TYPE NUMBER 8 Circuit Breaker Assembly 2 SERIES PB 3 ACTUATOR TYPE 1 Handle, one per pole 2 Handle, one per multipole unit ARocker2 B Rocker (Full Cutout for Breaker)2,3 4 POLES PER UNIT - INCLUDING ELECTRONIC MODULE 2Two 3Three 4Four 1 4 1 3 Actuator 4 Poles 5 Mounting 5 MOUNTING SCREWS / PLATE MATERIAL1 1 6-32 Thread Phillips Head 2 M-3 Thread Phillips Head 3 6-32 Thread Slotted Head 4 M-3 Thread Slotted Head 5 6-32 Thread Phillips Head w/ Stainless Steel Plate 6 M-3 Thread Phillips Head w/ Stainless Steel Plate 7 6-32 Thread Slotted Head w/ Stainless Steel Plate 8 M-3 Thread Slotted Head w/ Stainless Steel Plate Notes: 1 Screws supplied to accommodate mounting panel thickness of 1/8” ± 1/32”. Consult Factory for additional options 2 Available for Flat and Curved Rocker options - No Rockerguard Bracket 3 Code B available for use with Special CAT sheet Product only Handle Style Panel Seal Rocker Style Panel Seal www.carlingtech.com 9 PB-Series – Panel Seal Configuration - Drawings Handle Actuator Rocker Actuator 10 www.carlingtech.com PB-Series –Time Delay Curves Time Delay Curves Instantaneous Medium Short Long www.carlingtech.com 11 PC-Series - Introduction PC-Series GFCI/ELCI & Panel Seal The PC-Series, AC Residual Current Circuit Breaker with Overcurrent Protection (RCBO), combines the ground fault protection of a GFCI with the familiar overcurrent tripping characteristics of a normal circuit breaker. The PC-series utilizes the hydraulic magnetic principle which provides precise operation and performance even when exposed to extremely hot and/or cold application environments. Features: Overload, short circuit and ground fault protection in a single package Handle style actuators and rocker style “acuguard” Wiping Contacts - Mechanical linkage with two-step actuation – cleans contacts, provides high, positive contact pressure & longer contact life A trip-free mechanism, a safety feature which makes it impossible to manually hold the contacts closed during overload or fault conditions. A common trip linkage between all poles, another safety feature, ensures that an overload in one pole will trip all adjacent poles. Front panel mounting Integral push-to-test button Two integrated LED indicators distinguish if a breaker is closed with Line Voltage present, or has opened due to leakage current, or has opened due to over current, or is closed with no Line Voltage present. Optional Hot/Neutral reversal detection and protection 12 Benefits: Increases safety around boats and marinas Protects against electrical shock hazards in areas near water Protects against defects in the wires & conductors Reduces fire and shock hazards from defects in permanently installed appliances such as water heaters, battery chargers, lighting fixtures, etc. Detects low level ground faults, which do not trip ordinary circuit breakers, that can lead to fires and shock hazards for boating occupants www.carlingtech.com PC-Series Circuit Breaker - General Specifications Electrical Tables Table A: Lists UL Listed configurations as a Ground Fault Circuit Interruptor TABLE A : LISTS UL LISTED CONFIGURATIONS AS A GROUND FAULT CIRCUIT INTERRUPTOR CURRENT SHORT CIRCUIT RATING CAPACITY VOLTAGE CIRCUIT CONFIGURATION SERIES MAX. RATING FREQUENCY PHASE AMPS AMPS GROUND FAULT TRIP LEVEL MILLIAMPS NOTES 120 50 / 60 1 1 - 50 5000 6 1 or 2 Poles. One pole of a two pole unit must be Neutral 120/240 50 / 60 1 1 - 50 5000 6 2 or 3 Poles. One pole of a three pole unit must be Neutral Table B: Lists UL Listed and Recognized as an Earth Leakage Circuit Interruptor - 120 and 120/240V TABLE B : LISTS UL LISTED AND RECOGNIZED CONFIGURATIONS AS AN EARTH LEAKAGE CIRCUIT INTERRUPTOR - 120 and 120/240V GROUND CURRENT SHORT CIRCUIT VOLTAGE FAULT TRIP RATING CAPACITY LEVEL CIRCUIT MAX. FREQUENCY PHASE AMPS MILLIAMPS NOTES AMPS CONFIGURATION RATING SERIES 120 50 / 60 1 1 - 50 5000 30 1 or 2 Poles. One pole of a two pole unit must be Neutral 120/240 50 / 60 1 1 - 50 5000 30 2 or 3 Poles. One pole of a three pole unit must be Neutral SERIES 120 50 / 60 1 1 - 50 3000 30 1 or 2 Poles. One pole of a two pole unit must be Neutral IGNITION PROTECTED 120/240 50 / 60 1 1 - 50 5000 30 2 or 3 Poles. One pole of a three pole unit must be Neutral Table C: Lists UL Listed and Recognized as an Earth Leakage Circuit Interruptor - 240V TABLE C : LISTS UL LISTED AND RECOGNIZED CONFIGURATIONS AS AN EARTH LEAKAGE CIRCUIT INTERRUPTOR - 240V GROUND CURRENT SHORT CIRCUIT FAULT TRIP VOLTAGE RATING CAPACITY LEVEL CIRCUIT MAX. MILLIAMPS NOTES FREQUENCY PHASE AMPS AMPS CONFIGURATION RATING SERIES 240 50 / 60 1 1 - 30 5000 30 2 or 3 Poles. One pole of a three pole unit must be Neutral. Suffix 11 SERIES IGNITION PROTECTED 240 50 / 60 1 1 - 50 3000 30 2 or 3 Poles. One pole of a three pole unit must be Neutral. Suffix 12 www.carlingtech.com 13 PC-Series Circuit Breaker - General Specifications Electrical Mechanical Current Ratings Voltage Rating Current Trip Level Current Trip Time Operating Frequency Interrupt Capacity Impedance 1 - 50 Amps maximum 120VAC, 120/240VAC, 240VAC 30mA & 6mA For 30mA leakage trip: ≤ 22.2mA, shall not trip 30mA, shall trip within .10 seconds The above complies with UL-1053 & ABYC E11. For 6mA leakage trip: ≤25ms The above complies with UL-943. 50/60 Hz for 30mA leakage trip 60 Hz for 6mA leakage trip 5,000 Amps RESISTANCE, IMPEDANCE VALUES from Line to Load Terminals (Values Based on Series Trip Circuit Breaker) 1000 20.1 - 50.0 100 10 O H M S 1 0.1 10,000 ON-OFF operations @ 6 per minute; with rated Current & Voltage. Trips on short circuit, overload or leakage to ground, even when actuator is forcibly held in the “On” position Physical Number of Poles 1-pole (1 Circuit Breaker + 1 (Breakers only) GFCI Sensor Module), 120V 2-pole (2 Circuit Breakers + 1 GFCI Sensor Module), 120/240V or 120V with Neutral Break. 240VAC two pole. 3-pole 120/240V with Neutral Break (Sensor module has 2 pole width) Circuit Breaker Line Side: #10-32, Threaded stud. Termination GFCI Sensor Module Load Side: #10-32 threaded stud. Neutral pigtail. Mounting Front Panel, #6-32 and M3 threaded inserts. Actuator Handle, Flat Rocker, Curved Rocker (with or without rocker guard), Push-to-Reset Rocker Environmental 0.01 0.001 0.01 Endurance Trip Free 0.1 1 10 Designed and tested in accordance with requirements of specification MIL-PRF- 55629 and MIL-STD-202G as follows: 100 AMPERE RATING Innovative Features CURRENT (AMPS) TOLERANCE (%) 0.100 - 5.0 ± 15% 5.1 - 20.0 ± 25% Indicator Neutral Protection Test Button 20.1 - 30.0 ± 35% FIGURE 1 Two integrated LEDs, Red & Green Green LED On, Red LED Off Line Voltage is present, the breaker is closed, and the device is protecting the circuits against over current and leakage current. Green LED Off, Red LED On The device has detected leakage current and has opened the circuit breaker. Green LED Flashing, Red LED Off The circuit breaker has opened due to over current or has been turned off manually Green LED Off, Red LED Off Line Voltage is not present Green LED Flashing, Red LED Off, Amber LED ON Indicates Hot & Neutral are reversed and the circuit breaker is open When neutral is grounded on load side of circuit Located on Ground Fault Module Shock Withstands 100 G, 6ms, sawtooth at rated current per Method 213, Test Condition “I”. Vibration Withstands 0.06” excursion from 10-55 Hz, and 10 G 55-500 Hz, a rated current per Method 204C, Test Condition A. Instantaneous & ultrashort curves tested at 90% of rated current. Moisture Resistance 93% RH at 30°C for 168 Hours. Operating Temperature -35°C to +66°C Corrosion UL-943-6.21, 3 weeks Humidity: 30±2°C, 70±2% relative humidity Mixed Flowing Gases: 100 ppb H2S, 20 ppb CI2, 200±50 ppb NO2 Agency Certifications UL Listed UL Standard 489 Circuit Breakers, Molded Case, (Guide DIVQ, File E129899) UL Standard 1077 Supplementary Protectors UL Standard 943 Class A Ground Fault Circuit Interrupters UL Standard 1053 Ground Fault Sensing and Relaying Equipment UL Standard 1500 Ignition Protection *Manufacturer reserves the right to change product specification without prior notice. 14 www.carlingtech.com PC-Series – Ordering Scheme PC B 1 Series 2 System Voltage/Poles B A 3 Circuit 4 Actuator 24 5 Frequency & Delay 1 SERIES PC 1 B A 7 Terminal 8 Actuator Color 9 Mounting/ Barriers A 10 10 Trip Level 11 Agency Approval 6 CURRENT RATING (AMPERES) 3 CIRCUIT B Series Trip (Current) Single Color Curved Rocker Push-to-Reset R Vertical legend U Horizontal legend Two Color Flat Visi-Rocker 1 Indicate OFF, vertical legend 2 Indicate OFF, horizontal legend Single Color Flat Rocker 3 Vertical legend 4 Horizontal legend Two Color Flat Visi-Rocker Push-to-Reset 5 Indicate OFF, vertical legend 6 Indicate OFF, horizontal legend Single Color Flat Rocker Push-to-Reset 7 Vertical legend 8 Horizontal legend 5 FREQUENCY & DELAY 20 50/60Hz Instantaneous 21 50/60Hz Ultra Short 22 50/60Hz Short 24 50/60Hz Medium 26 50/60Hz Long Notes: 1 This device meets the requirements of ABCY E11. 2 6mA per UL943, available with agency approval code 10. 3 30mA per UL1053, available with agency approval codes 11 & 12. 4 AIC Rating at 120 VAC 3kA, at 120/240 VAC 5kA www.carlingtech.com 6 Current Rating CODE 2 SYSTEM VOLTAGE / POLES A 120 VAC single phase, one pole B 120/240 VAC single phase, two pole C 120/240 VAC single phase with switched neutral, three pole D 120 VAC single phase with switched neutral, two pole E 120 VAC single phase with reversed polarity indicator, two pole F 120/240 VAC single phase with reversed polarity indicator, three pole G 240 VAC single phase, two pole 4 ACTUATOR Handle A one per pole B one per multipole unit Two Color Curved Visi-Rocker C Indicate ON, vertical legend D Indicate ON, horizontal legend F Indicate OFF, vertical legend G Indicate OFF, horizontal legend Single Color Curved Rocker J Vertical legend K Horizontal legend Two Color Curved Visi-Rocker Push-to-Reset N Vertical legend O Horizontal legend 620 210 215 220 225 230 235 240 245 250 255 260 265 270 275 280 AMPERES 0.100 0.150 0.200 0.250 0.300 0.350 0.400 0.450 0.500 0.550 0.600 0.650 0.700 0.750 0.800 285 290 295 410 512 415 517 420 522 425 527 430 435 440 445 0.850 0.900 0.950 1.000 1.250 1.500 1.750 2.000 2.250 2.500 2.750 3.000 3.500 4.000 4.500 450 455 460 465 470 475 480 485 490 495 610 710 611 711 612 5.000 5.500 6.000 6.500 7.000 7.500 8.000 8.500 9.000 9.500 10.000 10.500 11.000 11.500 12.000 712 613 614 615 616 617 618 620 622 624 625 630 635 640 650 12.500 13.000 14.000 15.000 16.000 17.000 18.000 20.000 22.000 24.000 25.000 30.000 35.000 40.000 50.000 7 TERMINAL 1 Stud, 10-32 threaded 8 ACTUATOR COLOR & LEGEND HandleRocker Actuator Color Actuator Color I-O ON-OFF Dual Single Visi-Rocker White A B 1Black White Black C D 2White N/A Red F G 3White Red Green H J 4White Green Blue K L 5White Blue Yellow M N 6Black Yellow Gray P Q 7Black Gray Orange R S 8Black Orange 9 MOUNTING/BARRIERS MOUNTING STYLE BARRIERS Threaded Insert, 2 per pole A 6-32 X 0.195 inches yes B ISO M3 x 5mm yes Rockerguard Bezel Threaded Insert, 2 per pole C 6-32 X 0.195 inches yes D ISO M3 x 5mm yes Standard Bezel with Recessed Off-Side Flat Rocker Threaded Insert, 2 per pole E 6-32 X 0.195 inches yes F ISO M3 x 5mm yes Push-to-Reset Bezel Threaded Insert, 2 per pole G 6-32 X 0.195 inches yes H ISO M3 x 5mm yes 10 LEAKAGE CURRENT TRIP LEVEL - MAX. TRIP CURRENT A 5 MA (CLASS A GFCI)2 E 30 MA (ELCI)1,3 11 AGENCY APPROVAL AA W/O Approvals UL 9432 10 UL 10531,3 11 UL 1053 & UL 15001,3,4 12 15 PC-Series – Wiring Diagrams INDICATE OFF / SINGLE COLOR ROCKER ACTUATOR HANDLE / INDICATE ON ROCKER ACTUATOR TERMINAL LOCATIONS PC 120 VAC V W/ REVERSE INDICA PCA 120 VAC VERSION PCF 120/240 VAC V W/ REVERSE P INDICAT PCB 120/240 VAC VERSION 3.015 [76.58] MAX. PCC 120/240 VAC VERSION W/ NEUTRAL BREAK 3.775 [95.88] MAX. PCD 120 VAC VERSION W/NEUTRAL BREAK 16 www.carlingtech.com PC-Series – Wiring Diagrams & Panel Cut Out INDICATE OFF / SINGLE COLOR ROCKER ACTUATOR PCE 120 VAC VERSION W/ REVERSE POLARITY INDICATOR PCF 120/240 VAC VERSION W/ REVERSE POLARITY INDICATOR NOTE: NEUTRAL & GROUND PIGTAIL WIRES - SUPPLIED 12" LONG MIN. (CIRCUIT CODES A,B,E & F) LOAD NEUTRAL E1 TERMINAL LOCATIONS HANDLE / INDICATE ON ROCKER ACTUATOR 3.790 [96.27] PANEL CUTOUT ROCKER 3.040 [77.22] 2.280 [57.91] SOURCE NEUTRAL LINE 2 LINE 1 PANEL CUTOUT HANDLE 3.040 [77.22] 2.280 [57.91] .156 DIA. [Ø3.96] 2 PLC'S. TYP. PER POLE LINE 2 1.453 [36.91] 1.660 [42.16] 1.260 [32.00] 2.062 [52.37] SOURCE NEUTRAL LINE 2 LINE 1 240 VAC witching LOAD HOT 2 OR 230V NEUTRAL .432 [10.97] LOAD HOT 1 LINE 2 OR 230V NEUTRAL .750 [19.05] LINE 1 TYP. .200 [5.08] PCA, PCB PCD & PCE PCC & PCF PCA 1-Phase 240VAC PCB, PCD & PCE PCC & PCF www.carlingtech.com HANDLE ACTUATOR ROCKER ACTUATOR 17 PC-Series – Dimensions 2.265 [57.53] MAX. 1.510 [38.35] 2.975 [75.57] 0.430 [10.92] 0.275 [6.99] 0.750 TYP. [19.05] 2.518 [63.96] 3.800 [96.52] 2.062 [52.37] 1.453 [36.91] 0.429 [10.91] 0.350 [8.89] NEUTRAL PIGTAIL (CIRCUIT CODE A+B ONLY) #6/32 / M3 MOUNTING INSERTS 0.125 [3.18] 1.245 1.660 [31.62] [42.16] 0.208 [5.28] 0.100 [2.54] Notes: For additional circuit breaker dimensions, reference the C-Series Breakers in the Carling Circuit Protection catalog 18 www.carlingtech.com PC-Series – Panel Seal Ordering Scheme 8 PC 1 Type Number 2 Series 1 4 1 3 Actuator 4 Poles 5 Mounting 5 MOUNTING SCREWS / PLATE MATERIAL1 1 6-32 Thread Phillips Head 2 M-3 Thread Phillips Head 3 6-32 Thread Slotted Head 4 M-3 Thread Slotted Head 5 6-32 Thread Phillips Head w/ Stainless Steel Plate 6 M-3 Thread Phillips Head w/ Stainless Steel Plate 7 6-32 Thread Slotted Head w/ Stainless Steel Plate 8 M-3 Thread Slotted Head w/ Stainless Steel Plate 1 TYPE NUMBER 8 Circuit Breaker Assembly 2 SERIES PC 3 ACTUATOR TYPE 1 Handle, one per pole 2 Handle, one per multipole unit ARocker2 B Rocker (Full Cutout for Breaker)2,3 4 POLES PER UNIT - INCLUDING ELECTRONIC MODULE 2Two 3Three 4Four 5Five Notes: 1 Screws supplied to accommodate mounting panel thickness of 1/8” ± 1/32”. Consult Factory for additional options 2 Available for Flat and Curved Rocker options - No Rockerguard Bracket 3 Code B available for use with Special CAT sheet Product only Handle Style Panel Seal Rocker Style Panel Seal www.carlingtech.com 19 PC-Series – Panel Seal Configuration - Drawings Handle Actuator Rocker Actuator 20 www.carlingtech.com PC-Series –Time Delay Curves Time Delay Curves Instantaneous Medium Ultra Short Long Short Notes: Other time delay values available, consult factory. Delay Curves 21,22,24,26: Breakers to hold 100% and must trip at 125% of rated current and greater within the time limit shown in this curve. Delay Curve 20: Breakers to hold 100% and must trip at 150% of rated current and greater within the time limit shown in this curve. All Curves: Curve data shown represents breaker response at ambient temperature of 77°F (25°C) with no preloading. Breakers are mounted in standard wall-mount position. The minimum inrush pulse tolerance handling capability is 12 times the rated current. These values are based on a 60 Hz 1/2 cycle, 8.33 ms pulse. www.carlingtech.com 21 PD-Series - Introduction PD-Series Ground Fault Circuit Protection SmartGuard is an equipment ground fault protection device that functions as a standard high-quality Carling hydraulic/magnetic circuit breaker, offering customized overload and short circuit protection. In addition, this breaker senses and guards against faults to ground using a state of the art integrated circuit developed by Carling. This new technology detects faults and when a fault occurs, the breaker trips and an LED illuminates. The LED gives a clear indication that the trip occurred as a result of leakage. This protection helps prevent serious equipment damage and fire. Features: Overload, short circuit and ground fault protection in a single package Handle style actuators with optional “handleguard” Wiping Contacts - Mechanical linkage with twostep actuation – cleans contacts, provides high, positive contact pressure & longer contact life A trip-free mechanism, a safety feature which makes it impossible to manually hold the contacts closed during overload or fault conditions. A common trip linkage between all poles, another safety feature, ensures that an overload in one pole will trip all adjacent poles. Front panel or DIN rail mounting options “State of the art” integrated circuit developed by Carling Equipment leakage sensitivity from 10 to 100 milliamps Integral push-to-test button and LED “tripped” indicator Immediate reset after fault has been cleared 22 Agency Certifications: UL Standard 1077 Component Recognition Program as Equipment Leakage Circuit Interrupter and, Protectors, Supplementary (FTTJ2, File E177510). UL Standard 943 Tested as Ground Fault Circuit Interrupters for Equipment Protection. CSA Certified Component Equipment Leakage Current Interrupter with Supplementary Protector, under Class C22.2,No. 144-M91, File LR47848-50 TUV Certified IEC 947-2 and appendix B: Circuit Breakers incorporating Residual Current Protection. Complies with waveform requirements of IEC 1008-1, Type A. www.carlingtech.com PD-Series Circuit Breaker - General Specifications Electrical Tables Table A: Lists UL Recognized & CSA Certified configurations and performance capabilities as a Component Supplementary Protector. Table B: Lists TUV Certified configurations and performance capabilities as a Circuit breaker incorporating residual current protection. TABLE A: COMPONENT SUPPLEMENTARY PROTECTOR & EARTH LEAKAGE CURRENT INTERRUPTER VOLTAGE CIRCUIT CONFIGURATION SERIES INTERRUPTING CURRENT RATING FULL GENERAL LEAKAGE CAPACITY (AMPS) CURRENT UL / CSA MUST - TRIP MAX RATING FREQUENCY LOAD PURPOSE WITHOUT RATING VOLTS HERTZ PHASE AMPS AMPS BACKUP FUSE (MILLIAMPS) 120/208 50/60 1 1-50 --- 5000 7-100 120/208 50/60 31 1-50 --- 5000 7-100 208-240 50/60 3 1-50 --- 2000 7-100 480Y 50/60 3 1-30 30.1-50 2000 7-100 Electrical Maximum Voltage AC, 480 WYE/277 VAC, 50/60 Hz Standard Current Ratings 1.00, 2.50, 5.00, 7.50, 10.0, 15.0, 20.0, 25.0, 30.0, 35.0, 40.0 & 50.0 amps. For other ratings, consult factory. Insulation Resistance Minimum - 100 Megohms @ 500 VDC. Dielectric Strength 1960 VAC, 60 Hz for one minute between all electrically isolated terminals. Resistance, Impedance From Line to Load Terminal (Values Based on Series Trip RESISTANCE, IMPEDANCE VALUES Circuit Breaker) from Line to Load Terminals Ampere Rating Mechanical Endurance 10,000 ON-OFF operations @ 6 per minute; with rated current and voltage. Trip Free All SmartGuard equipment leakage circuit breakers will trip on overload or leakage to ground, even when actuator is forcibly held in the ON position. Trip Indication The actuator moves to the OFF position when an overload or earth leakage ground fault causes the breaker to trip. The LED is illuminated when leakage to ground causes the circuit breaker to trip. Physical 20.1 - 50.0 Pulse Tolerance Curve 60 Hz 1/2 Cycle Inrush Pulse Tolerance Multiple of Rated Current Ir Time Delay Curves 22, 24, 26 12x t 4.165 8.33 16.67 Time in Milliseconds Leakage To Ground Standard Must Trip Leakage Current Ratings 7, 10, 15, 30, 50 & 100 milliamps. For other ratings, consult factory. Trip Time 300 ms Max. @ 100%, 40ms Max. @ 500% of must trip leakage current. Test Button On breaker face above actuator. Leakage Trip Indicator Red LED on breaker face above actuator. Number of Poles Length (included switched or unswitched neutral) Width Depth Weight: 2-pole Standard Colors Mounting Termination 2, 3 & 4 4.2 inches ( 106.7 mm) 2-pole: 3.0 inches (76.2 mm) 3-pole: 3.75 inches (95.3 mm) 4-pole: 4.5 inches (114.3 mm) 2.5inches (63.5mm). 16.0 oz. (453.6 gm) 3-pole: 21.4 oz. (606.7 gm) 4-pole: 26.9 oz. (762.6 gm) Housing - gray; Actuator - black, red, or white Front Panel or Standard 35mm Symmetrical DIN Rail (35 x 7.5 or 35 x 15mm per DIN EN5002). Box Lug Environmental Operating Temperature +10°C to +50°C *Manufacturer reserves the right to change product specification without prior notice. www.carlingtech.com 23 PD-Series – Ordering Scheme PD R 1 Series 2 System Voltage/Poles B 3 Circuit 24 4 Frequency & Delay 650 5 Current Rating 2 SYSTEM VOLTAGE / POLES1 System Voltage 120VAC 1Ø A 120/240 VAC 1Ø B 120/208 VAC 1Ø, C 120/240 VAC 1Ø 120/208 VAC 1Ø, D 120/240 VAC 1Ø 208/240 VAC 3Ø E 208/240 VAC 3Ø F 208/240 VAC 3Ø G 480Y VAC 3Ø P 480Y VAC 3Ø Q 480Y VAC 3Ø R Poles One plus unswitched neutral Two Two plus unswitched neutral Two plus switched neutral Three Three plus unswitched neutral Three plus switched neutral Three Three plus unswitched neutral Three plus switched neutral 3 CIRCUIT Series Trip (Current) 4 FREQUENCY & DELAY 20 22 410 512 415 517 420 522 425 527 430 435 440 50/60Hz Instantaneous 50/60Hz Short 24 26 50/60Hz Medium 50/60Hz Long 8 Actuator 9 Actuator Color 10 Mounting C 11 Agency Approval AMPERES 1.000 1.250 1.500 1.750 2.000 2.250 2.500 2.750 3.000 3.500 4.000 445 450 455 460 465 470 475 480 485 490 495 4.500 5.000 5.500 6.000 6.500 7.000 7.500 8.000 8.500 9.000 9.500 7 TERMINAL 2 Front Connected Box Lug 8 ACTUATOR A Handle B Handle w/ handleguard 9 ACTUATOR COLOR & LEGEND4 Actuator Color I-O ON-OFF White A B Black C D Red E F Dual 1 2 3 Legend Color Black White White 11 AGENCY APPROVAL UL Recognized & CSA Certified C TUV Certified U 610 710 611 711 612 712 613 614 615 616 617 10.000 10.500 11.000 11.500 12.000 12.500 13.000 14.000 15.000 16.000 17.000 Time Delay Curves 24 7 Terminal 1 10 MOUNTING3 1 Threaded Insert 6-32 x 0.195 inches 2 Threaded Insert ISO M3 x 6.5 mm 5 CURRENT RATING (AMPERES) CODE 6 Equipment Leakage Trip Current 2 A 1 6 EQUIPMENT LEAKAGE - TRIP CURRENT (MILLIAMPS)2 B 7 D 15 F 50 C 10 E 30 G 100 1 SERIES PD B B 618 620 622 624 625 630 635 640 650 18.000 20.000 22.000 24.000 25.000 30.000 35.000 40.000 50.000 Notes: 1 Units with a switched or unswitched neutral connection are the same size as a unit with an additional breaker pole (e.g. a 2-pole unit with a switched or unswitched neutral is the same physical size as a 3-pole unit.) Switched neutral poles contain the same overcurrent protection as the other poles. 2 The leakage currents shown will cause the breaker to trip (must-trip current). The must- hold current is 67% of the must-trip current. 3 All breakers are front panel mountable using screw size shown. Breakers may also be mounted on either 35mm x 7.5mm or 35mm x 15mm symmetrical DIN rail. 4 TUV certifed units must have I-O or Dual legends Instantaneous Medium Short Long www.carlingtech.com PD-Series – Circuit & Terminal Diagrams Notes: 1 All dimensions are in inches [millimeters]. 2 Tolerance ±.020 [.51] unless otherwise specified. Notes: Other time delay values available, consult factory. Delay Curves 21,22,24,26: Breakers to hold 100% and must trip at 125% of rated current and greater within the time limit shown in this curve. Delay Curve 20: Breakers to hold 100% and must trip at 150% of rated current and greater within the time limit shown in this curve. All Curves: Curve data shown represents breaker response at ambient temperature of 77°F (25°C) with no preloading. Breakers are mounted in standard wall-mount position. The minimum inrush pulse tolerance handling capability is 12 times the rated current. These values are based on a 60 Hz 1/2 cycle, 8.33 ms pulse. www.carlingtech.com 25 PD-Series – Circuit & Terminal Diagrams Notes: 1 All dimensions are in inches [millimeters]. 2 Tolerance ±.020 [.51] unless otherwise specified. 26 www.carlingtech.com Literature Carling also offers several catalogs, covering all our circuit protection and control lines. This complete line of catalog information, which includes general specs, circuit and terminal drawings, form & fit drawings and complete ordering information, is available in printed form, as a downloadable PDF documents from our website. Please visit our website at www.carlingtech.com, scan the QR codes below or contact any one of our locations to request the following literature: Switches & Controls Switches and Controls Rocker, Toggle, Pushbutton & Rotary Hydraulic Magnetic Circuit Protection Hydraulic/Magnetic Circuit Breakers This Catalog details the complete line of Switches and Controls including Rocker, Toggle, Pushbutton, and Rotary style switches. This Catalog highlights the full line of Hydraulic Magnetic Circuit Breakers. Breakers from .02 to 700 amps with UL, CSA, VDE, TUV, UL489, UL489A, UL1500 certifications. Thermal’s GFCI’s Thermal Circuit Breaker Ground Fault Circuit Protection Reliable, Cost-effective Circuit Protection This Catalog focuses on the whole line of Thermal Circuit Breakers. Carling offers a variety of 3 to 60 amp, lighted and nonlighted, rocker actuator and push-to-reset push button thermal circuit breakers with UL, CUL, CE, UL1500/ISO 8846 certifications www.carlingtech.com This Catalog features the entire line of Ground Fault Circuit Breakers. GFCI breakers range from .10 to 50 amps, and are well suited for Marine industries use. 27 Literature On-Off Highway ON–OFF Highway Switches & Controls CATALOG Marine Marine Switches, Circuit Breakers & ELCI/GFCIs The On-Off Highway Catalog details the list of applicable products for the transportation industry. These include the Carling’s V, W, L, S and N-Series Switches. The Marine Catalog highlights the list of applicable products for the marine industry including switches, circuit breakers, GFCI’s, and the OctoPlex system. Military Renewable Energy Military Grade Renewable Energy Circuit Breakers and Disconnects COTS SWITCHES & CIRCUIT BREAKERS The Military Catalog focuses on the list of applicable products for military uses. These comprise of sealed rocker, toggle and miniature switches as well as circuit breakers The Renewable Energy Catalog features the list of applicable products for eco-friendly sources of energy. These are the Carling’s CX, C, G, E, and F-Series circuit breakers. Telecom/Datacom Carlingtech.com Telecom/Datacom Circuit Protection CATALOG This catalog focuses on the list of applicable products for the Telecom-Datacom industry. This features Carling’s L, CX, A, B, C, F and M-Series circuit breakers. 28 Visit us online for complete products and company information. www.carlingtech.com Notes www.carlingtech.com 29 Worldwide Headquarters Carling Technologies, Inc. 60 Johnson Avenue • Plainville, CT 06062 Phone: (860) 793-9281 • Fax: (860) 793-9231 Email: [email protected] • www.carlingtech.com East Region Sales Office, CT • [email protected] Midwest Region Sales Office, IL • [email protected] West Region Sales Office, CA • [email protected] Asia-Pacific Headquarters Carling Technologies, Asia-Pacific Ltd., Kowloon, Hong Kong Int + 852-2737-2277 • Fax: Int + 852-2736-9332 Email: [email protected] Shenzhen, China • [email protected] Shanghai, China • [email protected] Pune, India • [email protected] Kaohsiung, Taiwan • [email protected] Yokohama, Japan • [email protected] Europe / Middle East/Africa Headquarters Carling Technologies, Ltd., Devon, England Int + 44 1392-364422 • Fax: Int + 44 1392-364477 Email: [email protected] GmbH, Germany • [email protected] SAS, France • [email protected] GFCI-C_06_2013