GFCI/ELCI Circuit Protection

GFCI/ELCI
Circuit Protection
Transforming Customer Needs into Customer Solutions
Carling Technologies Sales, Service and Engineering teams do much more than manufacture electrical
components, they engineer powerful solutions! By working closely with a customer’s product team and
understanding the requirements of the specific application, Carling’s product experts can tailor switching
and circuit protection solutions to meet any customer’s needs—cost effectively.
Since the company was founded in 1920, there are few products that Carling Technologies hasn’t
turned “ON” and fewer industries that haven’t turned to Carling for solutions. With four ISO registered
manufacturing facilities and technical sales offices worldwide, Carling now ranks among the world’s largest,
privately owned manufacturers of hydraulic magnetic circuit breakers, thermal circuit breakers, electrical
switches, electronic switches, miniature switches, power distribution centers, digital switching systems and
electronic controls.
Globally, there are over 2,000 employees working for Carling, providing solutions to customers’ application
needs with innovation, value, and world-class service for both standard and custom products. Carling’s
breadth and depth of standard product offerings gives customers literally millions of configuration choices
to meet the demands of its Strategic Markets:
ŠŠ Marine
ŠŠ M ilitary
ŠŠ Renewable Energy
ŠŠ Telecom/Datacom
ŠŠ Transportation
Additional markets served by Carling products include: Audio Visual, Commercial Food Equipment,
Commercial HVAC, Floor Care, Generators, Industrial Control, Kitchen & Small Appliances, Security Systems,
Test & Measurement equipment, among others.
If the standard product does not meet the application requirements, the engineering team at Carling has
the expertise to customize solutions faster and more creatively thanks in measure to over ninety years of
experience as an innovative company that manufactures a diverse range of products. The Carling Sales,
Service and Engineering teams work closely with the customer’s engineering team to advance a custom
project from initial concept to final design and product release, respecting both quality and cost through
out the process. With extensive field knowledge and resources available, Carling Technologies can ensure
that the products created for the customer are of superior quality from the start, thus avoiding costly
secondary operations or modifications. Carling’s commitment to excellence consistently delivers “Quality
by Design,” the company mission.
Carling has an extensive network of Sales Representatives and Distributors to assist with Carling products,
or contact a Carling Technologies’ Technical Sales Representative to design innovative, cost-effective,
quality engineered solutions that exceed the tough demands of today’s applications.
ii
www.carlingtech.com
Table of Contents
2
3
GFCI Circuit Breaker - Selector Guide
PB–Series
General Specifications
12
22
Dimensional Specifications
Ordering Scheme
Wiring Diagrams
Panel Seal Ordering Scheme
Panel Seal Drawings
PC–Series
General Specifications
Dimensional Specifications
Ordering Scheme
Wiring Diagrams
Dimensions
Panel Seal Ordering Scheme
Panel Seal Drawings
Time Delay Curves
PD–Series
General Specifications
Ordering Scheme
Circuit & Terminal Diagrams
GFCI/ELCI
This catalog features Carling Technologies’ current line of GFCIs/ELCIs products, which offer
maximum equipment protection against overload and short circuits.
Carling’s Equipment leakage circuit breakers function as hydraulic/magnetic circuit breakers,
offering customized overload and short circuit protection. In addition, they sense and guard
against faults to ground using innovative electronics technologies. With the exception of small
amounts of leakage, the current returning to the power supply will be equal to the current
leaving the power supply. If the difference between the current leaving and returning through
the earth leakage circuit breaker exceeds the leakage sensitivity setting, the breaker trips and
its LED illuminates. The LED gives a clear indication that the trip occurred as a result of leakage
to ground. This protection helps prevent serious equipment damage and fire.
Typical Applications:
ŠŠ Marine
www.carlingtech.com
1
GFCI Circuit Breaker Selector Guide
PB-SERIES
2
PC-SERIES
PD-SERIES
1-3 poles, 3rd pole switched neutral
1-poles (1 Circuit Breaker + 1 GFCI Sensor
Module), 120V
2-pole (2 Circuit Breakers + 1 GFCI Sensor
Module), 120/240V or 120V with Neutral Break.
2-pole (2 Circuit Breakers + 1 GFCI Sensor
Module), 240VAC
3-pole 120/240V with Neutral Break (Sensor
module has 2 pole width)
1-3 poles, with switched or
unswitched neutral options
Handle, Rocker, Flat Rocker actuators
Handle, Rocker, Flat Rocker, Push-to-reset
Handle, with handle guard option
30mA & 6mA
30mA & 6mA
7-100 milliamps
LEAKAGE CURRENT
TRIP LEVEL
For 30mA leakage trip:
≤ 22.2mA, shall not trip
30mA, shall trip within .10 seconds,
complying with UL-1053
& ABYC E11. For 6mA leakage
trip: ≤25ms, complying with UL-943.
For 30mA leakage trip:
≤ 22.2mA, shall not trip
30mA, shall trip within .10 seconds,
complying with UL-1053
& ABYC E11. For 6mA leakage
trip: ≤25ms, complying with UL-943.
300 ms Max. @ 100%, 40ms
Max. @ 500% of must trip leakage current
LEAKAGE CURRENT
TRIP TIME
0.10 - 30 amps @ 120/240VAC
0.10 - 50 amps @ 120/240VAC - 240VAC
120VAC, Single Phase
120/208VAC, Single Phase
120/240VAC, Single Phase
208/240VAC, Three Phase
480Y/277VAC, Three Phase
5,000 amps
5,000 amps
5,000A @ 120/208 VAC;
120/240VAC, Single phase
2,000A @ 208/240, Three phase
2,000A @ 480Y/277VAC,
Three phase
Series Trip
Series Trip
Series Trip
.250 Quick Connect Tabs
8-32, 10-32, M4,M5 screw with upturned lugs
8-32, 10-32, M4,M5 screw, Bus Type
10-32 Threaded Stud
Front Connected Box Lug
w/ pressure plate
TERMINAL
OPTIONS
Front Panel
Front Panel
Front Mounted or Din Rail
Mounted
MOUNTING METHOD
-35° C to +65° C
-35° C to +65° C
-10°C to 60°C
UL489, CSA, UL1077, UL1500
UL943, UL1053, UL1500
UL Recognized, CSA, TUV
NUMBER OF POLES
ACTUATOR STYLE
MAXIMUM CURRENT &
VOLTAGE RATINGS
MAXIMUM
INTERRUPTING
CAPACITY
AVAILABLE
CIRCUITS
OPERATING
TEMPERATURE
AGENCY
APPROVALS
www.carlingtech.com
PB-Series - Introduction
PB-Series
GFCI/ELCI & Panel Seal
The PB-Series utilizes the hydraulic magnetic principle
which provides precise operation and performance even
when exposed to extremely hot and/or cold application
environments.
The new PB-Series, AC Residual Current Circuit Breaker with
Overcurrent Protection (RCBO), combines the ground fault
protection of a GFCI with the familiar overcurrent tripping
characteristics of a normal circuit breaker.
These precision mechanisms are temperature stable and
are not adversely affected by temperature changes in their
operating environment. As such, derating considerations
due to temperature variations are not normally required,
and heat-induced nuisance tripping is avoided.
Features:
ŠŠ Overload, short circuit and ground fault protection in a
single package
ŠŠ Handle or rocker style actuators
ŠŠ Wiping Contacts - Mechanical linkage with two-step
actuation – cleans contacts, provides high, positive
Benefits:
ŠŠ Increases safety around boats and marinas
contact pressure & longer contact life.
ŠŠ A trip-free mechanism, a safety feature which makes it ŠŠ Protects against electrical shock hazards in areas near water
impossible to manually hold the contacts closed during ŠŠ Protects against defects in wires & conductors
ŠŠ Reduces fire and shock hazards from defects in permanently
overload or fault conditions.
ŠŠ A common trip linkage between all poles, another safety
installed appliances such as water heaters, battery chargers,
feature, ensures that an overload in one pole will trip all lighting fixtures, etc.
ŠŠ Detects lower level ground faults which do not trip ordinary
adjacent poles.
ŠŠ Front panel mounting
circuit breakers, but can lead to fires, and shock hazards for
ŠŠ Integral push-to-test button
boating occupants
www.carlingtech.com
3
PB-Series Circuit Breaker - General Specifications
Electrical Tables
Mechanical
RESISTANCE, IMPEDANCE VALUES
Table A: UL Listed configurations and performance capabilities
Endurance
from Line to Load Terminals as Circuit Breakers.
(Values Based on Series Trip Circuit Breaker)
Trip Free
1000
(AMPS)
HERTZ
VOLTS
100
Electrical
Maximum Voltage
120/240VAC 60 Hz
10
Current Ratings
Standard current coils: 0.100, 0.250, 0.500, 0.750, 1.00, 2.50, 5.00, 7.50, 10.0, 15.0, 20.0, 25.0 O
& 30.0 amps. Other ratings 1
H
available, see ordering scheme.
M
Insulation Resistance
Minimum of 100 Megohms at 500 S
VDC.
Dielectric Strength 0.1
UL, CUL - 1500 V 60 Hz for one minute between all electrically isolated terminals. PB-Series circuit breakers comply with the 0.01
8mm spacing and 3750V 60 Hz
dielectric requirements from
hazardous voltage to operator
accessible surfaces and between
0.001
adjacent
0.01
0.1 poles 1
10
RESISTANCE, IMPEDANCE VALUES
Impedance
from Line to Load Terminals Values from Line to Load Terminal.
(Values Based on Series Trip Circuit Breaker)
1000
100
Ampere Rating
CURRENT
(AMPS)
TOLERANCE
(%)
0.100 - 5.0
± 15%
20.1 - 30.0
± 35%
5.1 - 20.0
10
± 25%
FIGURE 1
Pulse Tolerance Curve
1
Ir
0.1
60 Hz 1/2 Cycle
Inrush Pulse Tolerance
Multiple of
Rated Current
O
H
M
S
AMPERE RATING
0.01
Time Delay Curves
22, 24, 26
12x
t
0.001
0.01
0.1
1
10
100
AMPERE RATING
4.165
8.33
16.67
Time in
Milliseconds
Leakage To Ground
CURRENT
(AMPS)
TOLERANCE
(%)
0.100 - 5.0
± 15%
5.1 - 20.0
± 25%
Standard Must Trip
120/240VAC 60 Hz
FIGURE 1
Leakage Current Ratings 5 & 30 milliamps. 5± 1mA for UL943, other leakage ratings test to UL1053.
For other ratings, consult factory.
Trip Time
300 ms Max. @ 100%, 40ms Max. @ 500% of must trip leakage current.
Test Button
On unit face along side of actuator.
20.1 - 30.0
± 35%
10,000 ON-OFF operations @ 6 per minute; with rated Current & Voltage.
All PB-Series Circuit Breakers will trip on overload or ground fault, even
when Handle is forcibly held in the ON position.
Trip Indication
The operating Handle moves positively to the OFF position when an overload
or ground fault causes the breaker to trip.
Physical
Number of Poles
1 - 3 poles, where the third pole is neutral
Internal Circuit Config. Series Trip
Weight
Approximately 65 grams/pole. (2.32 ounces/pole.)
Standard Colors
Housing- Black; Actuator - See Ordering Scheme.
Environmental
Designed and tested in accordance with requirements of
specification MIL-PRF- 55629 and MIL-STD-202 as follows:
Shock
Withstands 100 Gs, 6ms, sawtooth while carrying rated current per Method 213, Test Condition “I”. Ultra-
100
short curves tested @ 90% of rated current.
Vibration
Withstands 0.060” excursion from
10-55 Hz, and 10 Gs 55-500
Hz, at rated current per Method
204C, Test Condition A. Instantaneous and ultrashort curves tested at 90% of rated current.
Moisture Resistance
Method 106D, i.e., ten 24-hour cycles @ + 25°C to +65°C, 80-98% RH.
Salt Spray
Method 101, Condition A (90-95% RH @ 5% NaCl Solution, 96 hrs).
Thermal Shock
Method 107D, Condition A (Five cycles @ -55°C to +25°C to +85°C to +25°C).
Operating Temperature -35° C to +65° C
Corrosion Tested per UL943 FMG Test. 3 weeks @ 30°C 75% RH, 100ppb H2S, 20ppb CI2, 200ppb NO2
Agency Certifications
UL Listed
UL Standard 489
Circuit Breakers, Molded Case,
(Guide DIVQ, File E129899)
UL Standard 1077
Supplementary Protectors
UL Standard 943
Class A Ground Fault Circuit Interrupters
UL Standard 1053
Ground Fault Sensing and Relaying Equipment
*Manufacturer reserves the right to change product specification without prior notice.
4
www.carlingtech.com
PB-Series – Ordering Scheme
PB A
1
Series
B A
3
Circuit
2
System
Voltage/Poles
4
Actuator
24
5
Frequency
& Delay
1 SERIES
PB
2 SYSTEM VOLTAGE / POLES
A
120 VAC single phase, one pole
B
120/240 VAC single phase, two pole
C
120/240 VAC single phase with switched neutral, three pole
D
120 VAC two pole with switched neutral
3 CIRCUIT
B
Series Trip (Current)
4 ACTUATOR1
Handle
A one per pole
B one per multipole unit
Two Color Curved Visi-Rocker
C Indicate ON,
vertical legend
D Indicate ON,
horizontal legend
F
Indicate OFF,
vertical legend
G Indicate OFF,
horizontal legend
Single Color Curved Rocker
J
Vertical legend
K Horizontal legend
Two Color Flat Visi-Rocker
1
Indicate OFF,
vertical legend
2
Indicate OFF,
horizontal legend
Single Color Flat Rocker
3
Vertical legend
4
Horizontal legend
620
6
Current Rating
2 B A
7
Terminal
8
Actuator
Color
7 TERMINAL2
13 Push-On 0.250 Tab (Q.C.)
2 Screw 8-32 w/upturned lugs
3 Screw 8-32 (Bus Type)
4 Screw 10-32 w/upturned lugs
5 Screw 10-32 (Bus Type)
A G
9
Mounting/
Barriers
B
C
E
H
10
Trip Level
11
Agency
Approval
Screw M5 w/upturned lugs
Screw M4 w/upturned lugs
Screw M4 (Bus Type)
Screw M5 (Bus Type)
8 ACTUATOR COLOR & LEGEND
HandleRocker Actuator Color
Actuator Color I-O ON-OFF Dual
Single
Visi-Rocker
White
A B 1Black
White
Black
C D 2White
N/A
Red
F G 3White
Red
Green
H J 4White Green
Blue
K L 5White
Blue
Yellow
M N 6Black Yellow
Gray
P Q 7Black
Gray
Orange
R S 8Black Orange
9 MOUNTING/BARRIERS
MOUNTING STYLE
Threaded Insert, 2 per pole
A 6-32 X 0.195 inches
B ISO M3 x 5mm
BARRIERS
yes
yes
10 LEAKAGE CURRENT TRIP LEVEL - MAX. TRIP CURRENT
A 5 MA (CLASS A GFCI)3,4,5
E 30 MA (ELCI)
11 AGENCY APPROVAL
G
UL489 Listed, CSA Certified
C
UL1077
I
UL1077/UL1500 Ignition Protected, CSA Certified6
5 FREQUENCY & DELAY
22
60Hz Short
24
60Hz Medium
26
60Hz Long
6 CURRENT RATING (AMPERES)
CODE
AMPERES
210 0.100
215 0.150
220 0.200
225 0.250
230 0.300
235 0.350
240 0.400
2450.450
250 0.500
255 0.550
260 0.600
265 0.650
270 0.700
275 0.750
280 0.800
285
290
295
410
512
415
517
420
522
425
527
430
435
440
445
0.850
0.900
0.950
1.000
1.250
1.500
1.750
2.000
2.250
2.500
2.750
3.000
3.500
4.000
4.500
www.carlingtech.com
450
455
460
465
470
475
480
485
490
495
610
710
611
711
612
5.000
5.500
6.000
6.500
7.000
7.500
8.000
8.500
9.000
9.500
10.000
10.500
11.000
11.500
12.000
712
613
614
615
616
617
618
620
622
624
625
630
12.500
13.000
14.000
15.000
16.000
17.000
18.000
20.000
22.000
24.000
25.000
30.000
Notes:
1 Actuator Code:
A: Handle tie pin spacer(s) and retainers provided unassembled with multi-pole units.
B: Handle location as viewed from front of breaker:
2 pole - left pole 3 pole - center pole
2 Screw Terminals are recommended on ratings greater than 20 amps.
3 Available with leakage current trip level - Max trip current code E, and agency
approval C.
4 6mA per UL943, available with agency approval code G.
5 30mA per UL1053, available with agency approval codes C & G.
6 UL1500 only available with 30MA trip level.
5
PB-Series – Dimensional Specifications
INDICATE "ON"
1.515 MAX
[38.48]
3.03
[76.9]
INDICATE
"OFF"
AND
SINGLE
COLOR
LINE
.21
[5.3]
1.25
[31.6]
TEST
LOAD
2.17
[55.0]
LOAD
1-POLE 120 VAC VERSION
TEST
LINE
SCALE
0.500
#6-32/M3 MOUNTING INSERTS
1.88
[47.8]
LINE TERMINAL
2.265 MAX
[57.53]
1.660
[42.16]
2.58
[65.6]
TEST
2.37
[60.2]
+.020
1.500
-.000
+.50
38.10
-.00
[
.375
[9.53]
.39
[9.9]
CURRENT TRANSFORMERS
LOAD TERMINAL
1.260
[32.00]
GFCI NEUTRAL WIRE
2-POLE 120/240 VAC VERSION
.20
[5.1]
]
.750 TYP
[19.05]
1.660
[42.16]
SCALE 0.500
+.020
2.250
-.000
+.50
57.15
-.00
[
Ø .156 TYP
[3.96]
]
PANEL CUTOUT
NEUTRAL BREAK POLE
3.015 MAX
[76.58]
.750 TYP
[19.05]
TEST
2-POLE 120/240 VAC WITH NEUTRAL BREAK
Notes:
1 All dimensions are in inches [millimeters].
2 Tolerance ±.020 [.51] unless otherwise specified.
6
www.carlingtech.com
PB-Series – Dimensional Specifications
Notes:
1 All dimensions are in inches [millimeters].
2 Tolerance ±.020 [.51] unless otherwise specified.
www.carlingtech.com
7
PB-Series – Wiring Diagrams
120VAC without Switched Neutral
120VAC with Switched Neutral
SYSTEM NEUTRAL
SYSTEM NEUTRAL
GFCI
MODULE
PIGTAIL
GFCI
MODULE
PIGTAIL
LOAD
HOT
LOAD
NEUTRAL
LOAD
HOT
LINE/SOURCE
(HOT)
LINE/SYSTEM
NEUTRAL
LINE/SOURCE
(HOT)
120 VAC
LOAD
120 VAC
LOAD
AC SOURCE
AC SOURCE
120 VAC WITH SWITCHED NEUTRAL
120 VAC WITHOUT SWITCHED NEUTRAL
120 VAC WITH SWITCHED NEUTRAL
120 VAC WITHOUT SWITCHED
NEUTRAL
120/240VAC with Switched Neutral
120/240VAC without Switched Neutral
SYSTEM
NEUTRAL
SYSTEM
NEUTRAL
GFCI
MODULE
PIGTAIL
GFCI
MODULE
PIGTAIL
LOAD
HOT
1
LINE/SOURCE 1
120 VAC
LOAD
120 VAC
LOAD
LOAD
HOT
2
LINE/
SOURCE
2
LOAD
HOT
1
LOAD
NEUTRAL
LINE/SYSTEM
NEUTRAL
120 VAC
LOAD
120 VAC
LOAD
LOAD
HOT
(2)
LINE/
SOURCE
(2)
LINE/SOURCE
(1)
240 VAC LOAD
240 VAC LOAD
AC SOURCE
120 VAC WITH SWITCHED NEUTRAL
120/240 VAC WITH SWITCHED NEUTRAL
8
AC SOURCE
120 VAC WITHOUT SWITCHED NEUTRAL
120/240 VAC WITHOUT SWITCHED NEUTRAL
www.carlingtech.com
PB-Series – Panel Seal Ordering Scheme
8 PB
1
Type
Number
2
Series
1 TYPE NUMBER
8
Circuit Breaker Assembly
2 SERIES
PB
3 ACTUATOR TYPE
1
Handle, one per pole
2
Handle, one per multipole unit
ARocker2
B Rocker (Full Cutout for Breaker)2,3
4 POLES PER UNIT - INCLUDING ELECTRONIC MODULE
2Two
3Three
4Four
1 4 1
3
Actuator
4
Poles
5
Mounting
5 MOUNTING SCREWS / PLATE MATERIAL1
1 6-32 Thread Phillips Head
2 M-3 Thread Phillips Head
3 6-32 Thread Slotted Head
4 M-3 Thread Slotted Head
5 6-32 Thread Phillips Head w/ Stainless Steel Plate
6 M-3 Thread Phillips Head w/ Stainless Steel Plate
7 6-32 Thread Slotted Head w/ Stainless Steel Plate
8
M-3 Thread Slotted Head w/ Stainless Steel Plate
Notes:
1 Screws supplied to accommodate mounting panel thickness of 1/8” ± 1/32”.
Consult Factory for additional options
2 Available for Flat and Curved Rocker options - No Rockerguard Bracket
3 Code B available for use with Special CAT sheet Product only
Handle Style Panel Seal
Rocker Style Panel Seal
www.carlingtech.com
9
PB-Series – Panel Seal Configuration - Drawings
Handle Actuator
Rocker Actuator
10
www.carlingtech.com
PB-Series –Time Delay Curves
Time Delay Curves
Instantaneous
Medium
Short
Long
www.carlingtech.com
11
PC-Series - Introduction
PC-Series
GFCI/ELCI & Panel Seal
The PC-Series, AC Residual Current Circuit Breaker with
Overcurrent Protection (RCBO), combines the ground fault
protection of a GFCI with the familiar overcurrent tripping
characteristics of a normal circuit breaker.
The PC-series utilizes the hydraulic magnetic principle
which provides precise operation and performance even
when exposed to extremely hot and/or cold application
environments.
Features:
ŠŠ Overload, short circuit and ground fault protection in a single package
ŠŠ Handle style actuators and rocker style “acuguard”
ŠŠ Wiping Contacts - Mechanical linkage with two-step actuation – cleans contacts, provides high, positive contact pressure & longer contact life
ŠŠ A trip-free mechanism, a safety feature which makes it impossible to manually hold the contacts closed during overload or fault conditions.
ŠŠ A common trip linkage between all poles, another safety
feature, ensures that an overload in one pole will trip all adjacent poles.
ŠŠ Front panel mounting
ŠŠ Integral push-to-test button
ŠŠ Two integrated LED indicators distinguish if a breaker is closed with Line Voltage present, or has opened due to leakage current, or has opened due to over current, or is closed with no Line Voltage present.
ŠŠ Optional Hot/Neutral reversal detection and protection
12
Benefits:
ŠŠ Increases safety around boats and marinas
ŠŠ Protects against electrical shock hazards in areas near water
ŠŠ Protects against defects in the wires & conductors
ŠŠ Reduces fire and shock hazards from defects in permanently
installed appliances such as water heaters, battery chargers,
lighting fixtures, etc.
ŠŠ Detects low level ground faults, which do not trip ordinary
circuit breakers, that can lead to fires and shock hazards for
boating occupants
www.carlingtech.com
PC-Series Circuit Breaker - General Specifications
Electrical Tables
Table A: Lists UL Listed configurations as a Ground Fault Circuit
Interruptor
TABLE A : LISTS UL LISTED CONFIGURATIONS AS A GROUND FAULT CIRCUIT INTERRUPTOR
CURRENT SHORT CIRCUIT
RATING
CAPACITY
VOLTAGE
CIRCUIT
CONFIGURATION
SERIES
MAX.
RATING
FREQUENCY
PHASE
AMPS
AMPS
GROUND
FAULT TRIP
LEVEL
MILLIAMPS
NOTES
120
50 / 60
1
1 - 50
5000
6
1 or 2 Poles. One pole of a two pole unit must be Neutral
120/240
50 / 60
1
1 - 50
5000
6
2 or 3 Poles. One pole of a three pole unit must be Neutral
Table B: Lists UL Listed and Recognized as an Earth Leakage
Circuit Interruptor - 120 and 120/240V
TABLE B : LISTS UL LISTED AND RECOGNIZED CONFIGURATIONS AS AN EARTH LEAKAGE CIRCUIT INTERRUPTOR - 120 and 120/240V
GROUND
CURRENT SHORT CIRCUIT
VOLTAGE
FAULT TRIP
RATING
CAPACITY
LEVEL
CIRCUIT
MAX.
FREQUENCY PHASE
AMPS
MILLIAMPS
NOTES
AMPS
CONFIGURATION
RATING
SERIES
120
50 / 60
1
1 - 50
5000
30
1 or 2 Poles. One pole of a two pole unit must be Neutral
120/240
50 / 60
1
1 - 50
5000
30
2 or 3 Poles. One pole of a three pole unit must be Neutral
SERIES
120
50 / 60
1
1 - 50
3000
30
1 or 2 Poles. One pole of a two pole unit must be Neutral
IGNITION PROTECTED
120/240
50 / 60
1
1 - 50
5000
30
2 or 3 Poles. One pole of a three pole unit must be Neutral
Table C: Lists UL Listed and Recognized as an Earth Leakage
Circuit Interruptor - 240V
TABLE C : LISTS UL LISTED AND RECOGNIZED CONFIGURATIONS AS AN EARTH LEAKAGE CIRCUIT INTERRUPTOR - 240V
GROUND
CURRENT SHORT CIRCUIT
FAULT TRIP
VOLTAGE
RATING
CAPACITY
LEVEL
CIRCUIT
MAX.
MILLIAMPS
NOTES
FREQUENCY PHASE
AMPS
AMPS
CONFIGURATION
RATING
SERIES
240
50 / 60
1
1 - 30
5000
30
2 or 3 Poles. One pole of a three pole unit must be Neutral. Suffix 11
SERIES IGNITION PROTECTED
240
50 / 60
1
1 - 50
3000
30
2 or 3 Poles. One pole of a three pole unit must be Neutral. Suffix 12
www.carlingtech.com
13
PC-Series Circuit Breaker - General Specifications
Electrical
Mechanical
Current Ratings
Voltage Rating
Current Trip Level
Current Trip Time
Operating Frequency
Interrupt Capacity
Impedance
1 - 50 Amps maximum
120VAC, 120/240VAC, 240VAC
30mA & 6mA
For 30mA leakage trip:
≤ 22.2mA, shall not trip
30mA, shall trip within .10 seconds
The above complies with UL-1053
& ABYC E11. For 6mA leakage trip: ≤25ms
The above complies with UL-943.
50/60 Hz for 30mA leakage trip
60 Hz for 6mA leakage trip
5,000 Amps
RESISTANCE, IMPEDANCE VALUES
from Line to Load Terminals
(Values Based on Series Trip Circuit Breaker)
1000
20.1 - 50.0
100
10
O
H
M
S
1
0.1
10,000 ON-OFF operations @ 6 per minute; with rated Current & Voltage.
Trips on short circuit, overload or leakage to ground, even when
actuator is forcibly held in the “On” position
Physical
Number of Poles
1-pole (1 Circuit Breaker + 1
(Breakers only) GFCI Sensor Module), 120V
2-pole (2 Circuit Breakers + 1 GFCI Sensor Module), 120/240V or 120V with Neutral Break. 240VAC two pole. 3-pole 120/240V with Neutral Break (Sensor module has 2
pole width) Circuit Breaker Line
Side: #10-32, Threaded stud.
Termination
GFCI Sensor Module Load Side: #10-32 threaded stud. Neutral pigtail.
Mounting
Front Panel, #6-32 and M3 threaded inserts.
Actuator
Handle, Flat Rocker, Curved Rocker (with or without rocker guard),
Push-to-Reset Rocker
Environmental
0.01
0.001
0.01
Endurance
Trip Free
0.1
1
10
Designed and tested in accordance with requirements of
specification MIL-PRF- 55629 and MIL-STD-202G as follows:
100
AMPERE RATING
Innovative Features
CURRENT
(AMPS)
TOLERANCE
(%)
0.100 - 5.0
± 15%
5.1 - 20.0
± 25%
Indicator
Neutral Protection
Test Button
20.1 - 30.0
± 35%
FIGURE 1
Two integrated LEDs, Red & Green
 Green LED On, Red LED Off
Line Voltage is present, the breaker is closed, and the device is protecting the circuits against over current and leakage current.
 Green LED Off, Red LED On
The device has detected leakage current and has opened the circuit breaker.
 Green LED Flashing, Red LED Off
The circuit breaker has opened due to over current or has been turned off manually
 Green LED Off, Red LED Off
Line Voltage is not present
 Green LED Flashing, Red LED Off, Amber LED ON
Indicates Hot & Neutral are reversed and the circuit breaker
is open
When neutral is grounded on load side of circuit
Located on Ground Fault Module
Shock
Withstands 100 G, 6ms, sawtooth at rated current per Method 213, Test Condition “I”.
Vibration
Withstands 0.06” excursion from
10-55 Hz, and 10 G 55-500 Hz, a
rated current per Method 204C, Test
Condition A. Instantaneous & ultrashort curves tested at 90% of rated current.
Moisture Resistance
93% RH at 30°C for 168 Hours.
Operating Temperature
-35°C to +66°C
Corrosion
UL-943-6.21, 3 weeks
Humidity:
30±2°C, 70±2% relative humidity
Mixed Flowing Gases:
100 ppb H2S, 20 ppb CI2,
200±50 ppb NO2
Agency Certifications
UL Listed
UL Standard 489
Circuit Breakers, Molded Case,
(Guide DIVQ, File E129899)
UL Standard 1077
Supplementary Protectors
UL Standard 943
Class A Ground Fault Circuit Interrupters
UL Standard 1053
Ground Fault Sensing and Relaying Equipment
UL Standard 1500
Ignition Protection
*Manufacturer reserves the right to change product specification without prior notice.
14
www.carlingtech.com
PC-Series – Ordering Scheme
PC B
1
Series
2
System
Voltage/Poles
B A
3
Circuit
4
Actuator
24
5
Frequency
& Delay
1 SERIES
PC
1 B A
7
Terminal
8
Actuator
Color
9
Mounting/
Barriers
A 10
10
Trip Level
11
Agency
Approval
6 CURRENT RATING (AMPERES)
3 CIRCUIT
B
Series Trip (Current)
Single Color Curved Rocker
Push-to-Reset
R Vertical legend
U Horizontal legend
Two Color Flat Visi-Rocker
1 Indicate OFF,
vertical legend
2 Indicate OFF,
horizontal legend
Single Color Flat Rocker
3 Vertical legend
4 Horizontal legend
Two Color Flat Visi-Rocker
Push-to-Reset
5 Indicate OFF,
vertical legend
6 Indicate OFF,
horizontal legend
Single Color Flat Rocker
Push-to-Reset
7 Vertical legend
8 Horizontal legend
5 FREQUENCY & DELAY
20
50/60Hz Instantaneous
21
50/60Hz Ultra Short
22
50/60Hz Short
24
50/60Hz Medium
26
50/60Hz Long
Notes:
1 This device meets the requirements of ABCY E11.
2 6mA per UL943, available with agency approval code 10.
3 30mA per UL1053, available with agency approval codes 11 & 12.
4 AIC Rating at 120 VAC 3kA, at 120/240 VAC 5kA
www.carlingtech.com
6
Current Rating
CODE
2 SYSTEM VOLTAGE / POLES
A
120 VAC single phase, one pole
B
120/240 VAC single phase, two pole
C
120/240 VAC single phase with switched neutral, three pole
D
120 VAC single phase with switched neutral, two pole
E
120 VAC single phase with reversed polarity indicator, two pole
F
120/240 VAC single phase with reversed polarity indicator, three pole
G
240 VAC single phase, two pole
4 ACTUATOR
Handle
A one per pole
B one per multipole unit
Two Color Curved Visi-Rocker
C Indicate ON,
vertical legend
D Indicate ON,
horizontal legend
F Indicate OFF,
vertical legend
G Indicate OFF,
horizontal legend
Single Color Curved Rocker
J Vertical legend
K Horizontal legend
Two Color Curved Visi-Rocker
Push-to-Reset
N Vertical legend
O Horizontal legend
620
210
215
220
225
230
235
240
245
250
255
260
265
270
275
280
AMPERES
0.100
0.150
0.200
0.250
0.300
0.350
0.400
0.450
0.500
0.550
0.600
0.650
0.700
0.750
0.800
285
290
295
410
512
415
517
420
522
425
527
430
435
440
445
0.850
0.900
0.950
1.000
1.250
1.500
1.750
2.000
2.250
2.500
2.750
3.000
3.500
4.000
4.500
450
455
460
465
470
475
480
485
490
495
610
710
611
711
612
5.000
5.500
6.000
6.500
7.000
7.500
8.000
8.500
9.000
9.500
10.000
10.500
11.000
11.500
12.000
712
613
614
615
616
617
618
620
622
624
625
630
635
640
650
12.500
13.000
14.000
15.000
16.000
17.000
18.000
20.000
22.000
24.000
25.000
30.000
35.000
40.000
50.000
7 TERMINAL
1
Stud, 10-32 threaded
8 ACTUATOR COLOR & LEGEND
HandleRocker Actuator Color
Actuator Color I-O ON-OFF Dual
Single
Visi-Rocker
White
A B 1Black
White
Black
C D 2White
N/A
Red
F G 3White
Red
Green
H J 4White Green
Blue
K L 5White
Blue
Yellow
M N 6Black Yellow
Gray
P Q 7Black
Gray
Orange
R S 8Black Orange
9 MOUNTING/BARRIERS
MOUNTING STYLE
BARRIERS
Threaded Insert, 2 per pole
A 6-32 X 0.195 inches
yes
B ISO M3 x 5mm
yes
Rockerguard Bezel
Threaded Insert, 2 per pole
C 6-32 X 0.195 inches yes
D ISO M3 x 5mm
yes
Standard Bezel with Recessed Off-Side Flat Rocker
Threaded Insert, 2 per pole
E 6-32 X 0.195 inches yes
F ISO M3 x 5mm yes
Push-to-Reset Bezel
Threaded Insert, 2 per pole
G 6-32 X 0.195 inches yes
H ISO M3 x 5mm yes
10 LEAKAGE CURRENT TRIP LEVEL - MAX. TRIP CURRENT
A 5 MA (CLASS A GFCI)2
E 30 MA (ELCI)1,3
11 AGENCY APPROVAL
AA W/O Approvals
UL 9432
10
UL 10531,3
11
UL 1053 & UL 15001,3,4
12
15
PC-Series – Wiring Diagrams
INDICATE OFF / SINGLE COLOR
ROCKER ACTUATOR
HANDLE / INDICATE ON
ROCKER ACTUATOR
TERMINAL
LOCATIONS
PC
120 VAC V
W/ REVERSE
INDICA
PCA
120 VAC
VERSION
PCF
120/240 VAC V
W/ REVERSE P
INDICAT
PCB
120/240 VAC
VERSION
3.015
[76.58]
MAX.
PCC
120/240 VAC
VERSION
W/ NEUTRAL BREAK
3.775
[95.88]
MAX.
PCD
120 VAC
VERSION
W/NEUTRAL BREAK
16
www.carlingtech.com
PC-Series – Wiring Diagrams & Panel Cut Out
INDICATE OFF / SINGLE COLOR
ROCKER ACTUATOR
PCE
120 VAC VERSION
W/ REVERSE POLARITY
INDICATOR
PCF
120/240 VAC VERSION
W/ REVERSE POLARITY
INDICATOR
NOTE: NEUTRAL & GROUND PIGTAIL WIRES - SUPPLIED 12" LONG MIN. (CIRCUIT CODES A,B,E & F)
LOAD NEUTRAL
E1
TERMINAL
LOCATIONS
HANDLE / INDICATE ON
ROCKER ACTUATOR
3.790 [96.27]
PANEL CUTOUT ROCKER
3.040 [77.22]
2.280 [57.91]
SOURCE
NEUTRAL
LINE 2
LINE 1
PANEL CUTOUT HANDLE
3.040 [77.22]
2.280 [57.91]
.156 DIA. [Ø3.96]
2 PLC'S. TYP.
PER POLE
LINE 2
1.453 [36.91]
1.660 [42.16]
1.260 [32.00]
2.062 [52.37]
SOURCE
NEUTRAL
LINE 2
LINE 1
240 VAC
witching
LOAD HOT 2
OR 230V NEUTRAL
.432 [10.97]
LOAD HOT 1
LINE 2
OR 230V NEUTRAL
.750 [19.05] LINE 1
TYP.
.200 [5.08]
PCA, PCB
PCD & PCE
PCC & PCF
PCA
1-Phase 240VAC
PCB, PCD & PCE
PCC & PCF
www.carlingtech.com
HANDLE ACTUATOR
ROCKER ACTUATOR
17
PC-Series – Dimensions
2.265
[57.53]
MAX.
1.510
[38.35]
2.975
[75.57]
0.430
[10.92]
0.275
[6.99]
0.750
TYP.
[19.05]
2.518
[63.96]
3.800
[96.52]
2.062
[52.37]
1.453
[36.91]
0.429
[10.91]
0.350
[8.89]
NEUTRAL PIGTAIL (CIRCUIT
CODE A+B ONLY)
#6/32 / M3 MOUNTING INSERTS
0.125
[3.18]
1.245
1.660 [31.62]
[42.16]
0.208
[5.28]
0.100
[2.54]
Notes:
For additional circuit breaker dimensions, reference the C-Series Breakers in the
Carling Circuit Protection catalog
18
www.carlingtech.com
PC-Series – Panel Seal Ordering Scheme
8 PC
1
Type
Number
2
Series
1 4 1
3
Actuator
4
Poles
5
Mounting
5 MOUNTING SCREWS / PLATE MATERIAL1
1 6-32 Thread Phillips Head
2 M-3 Thread Phillips Head
3 6-32 Thread Slotted Head
4 M-3 Thread Slotted Head
5 6-32 Thread Phillips Head w/ Stainless Steel Plate
6 M-3 Thread Phillips Head w/ Stainless Steel Plate
7 6-32 Thread Slotted Head w/ Stainless Steel Plate
8
M-3 Thread Slotted Head w/ Stainless Steel Plate
1 TYPE NUMBER
8
Circuit Breaker Assembly
2 SERIES
PC
3 ACTUATOR TYPE
1
Handle, one per pole
2
Handle, one per multipole unit
ARocker2
B Rocker (Full Cutout for Breaker)2,3
4 POLES PER UNIT - INCLUDING ELECTRONIC MODULE
2Two
3Three
4Four
5Five
Notes:
1 Screws supplied to accommodate mounting panel thickness of 1/8” ± 1/32”.
Consult Factory for additional options
2 Available for Flat and Curved Rocker options - No Rockerguard Bracket
3 Code B available for use with Special CAT sheet Product only
Handle Style Panel Seal
Rocker Style Panel Seal
www.carlingtech.com
19
PC-Series – Panel Seal Configuration - Drawings
Handle Actuator
Rocker Actuator
20
www.carlingtech.com
PC-Series –Time Delay Curves
Time Delay Curves
Instantaneous
Medium
Ultra Short
Long
Short
Notes:
Other time delay values available, consult factory.
Delay Curves 21,22,24,26: Breakers to hold 100% and must trip at 125% of rated
current and greater within the time limit shown in this curve.
Delay Curve 20: Breakers to hold 100% and must trip at 150% of rated current
and greater within the time limit shown in this curve.
All Curves: Curve data shown represents breaker response at ambient temperature of 77°F (25°C) with no preloading. Breakers are mounted in standard
wall-mount position.
The minimum inrush pulse tolerance handling capability is 12 times the rated current. These values are based on a 60 Hz 1/2 cycle, 8.33 ms pulse.
www.carlingtech.com
21
PD-Series - Introduction
PD-Series
Ground Fault Circuit Protection
SmartGuard is an equipment ground fault protection
device that functions as a standard high-quality
Carling hydraulic/magnetic circuit breaker, offering
customized overload and short circuit protection.
In addition, this breaker senses and guards against
faults to ground using a state of the art integrated
circuit developed by Carling. This new technology
detects faults and when a fault occurs, the breaker
trips and an LED illuminates. The LED gives a clear
indication that the trip occurred as a result of leakage.
This protection helps prevent serious equipment
damage and fire.
Features:
ŠŠ Overload, short circuit and ground fault protection
in a single package
ŠŠ Handle style actuators with optional
“handleguard”
ŠŠ Wiping Contacts - Mechanical linkage with twostep actuation – cleans contacts, provides high,
positive contact pressure & longer contact life
ŠŠ A trip-free mechanism, a safety feature which
makes it impossible to manually hold the contacts
closed during overload or fault conditions.
ŠŠ A common trip linkage between all poles, another
safety feature, ensures that an overload in one
pole will trip all adjacent poles.
ŠŠ Front panel or DIN rail mounting options
ŠŠ “State of the art” integrated circuit developed by
Carling
ŠŠ Equipment leakage sensitivity from 10 to 100
milliamps
ŠŠ Integral push-to-test button and LED “tripped”
indicator
ŠŠ Immediate reset after fault has been cleared
22
Agency Certifications:
UL Standard 1077 Component Recognition
Program as Equipment
Leakage Circuit Interrupter
and, Protectors, Supplementary
(FTTJ2, File E177510).
UL Standard 943 Tested as Ground Fault Circuit
Interrupters for Equipment
Protection.
CSA Certified
Component Equipment Leakage
Current Interrupter with
Supplementary Protector, under
Class C22.2,No. 144-M91, File
LR47848-50
TUV Certified
IEC 947-2 and appendix B: Circuit
Breakers incorporating Residual
Current Protection. Complies
with waveform requirements of
IEC 1008-1, Type A.
www.carlingtech.com
PD-Series Circuit Breaker - General Specifications
Electrical Tables
Table A: Lists UL Recognized & CSA Certified configurations
and performance capabilities as a Component Supplementary
Protector.
Table B: Lists TUV Certified configurations and performance
capabilities as a Circuit breaker incorporating residual current
protection.
TABLE A: COMPONENT SUPPLEMENTARY PROTECTOR & EARTH LEAKAGE CURRENT INTERRUPTER
VOLTAGE
CIRCUIT
CONFIGURATION
SERIES
INTERRUPTING
CURRENT RATING
FULL
GENERAL
LEAKAGE
CAPACITY (AMPS)
CURRENT
UL / CSA
MUST - TRIP
MAX RATING
FREQUENCY
LOAD
PURPOSE
WITHOUT
RATING
VOLTS
HERTZ
PHASE
AMPS
AMPS
BACKUP FUSE
(MILLIAMPS)
120/208
50/60
1
1-50
---
5000
7-100
120/208
50/60
31
1-50
---
5000
7-100
208-240
50/60
3
1-50
---
2000
7-100
480Y
50/60
3
1-30
30.1-50
2000
7-100
Electrical
Maximum Voltage AC, 480 WYE/277 VAC, 50/60 Hz
Standard Current Ratings 1.00, 2.50, 5.00, 7.50, 10.0, 15.0,
20.0, 25.0, 30.0, 35.0, 40.0 & 50.0 amps. For other ratings, consult factory.
Insulation Resistance
Minimum - 100 Megohms @ 500 VDC.
Dielectric Strength
1960 VAC, 60 Hz for one minute between all electrically isolated terminals.
Resistance, Impedance From Line to Load Terminal
(Values Based on Series Trip RESISTANCE, IMPEDANCE VALUES
Circuit Breaker)
from Line to Load Terminals
Ampere Rating
Mechanical
Endurance
10,000 ON-OFF operations @ 6 per minute; with rated current and voltage.
Trip Free
All SmartGuard equipment leakage circuit breakers will trip on overload or leakage to ground, even when actuator is forcibly held in the ON position.
Trip Indication
The actuator moves to the OFF position when an overload or earth leakage ground fault causes
the breaker to trip. The LED is illuminated when leakage to ground causes the circuit breaker to trip.
Physical
20.1 - 50.0
Pulse Tolerance Curve
60 Hz 1/2 Cycle
Inrush Pulse Tolerance
Multiple of
Rated Current
Ir
Time Delay Curves
22, 24, 26
12x
t
4.165
8.33
16.67
Time in
Milliseconds
Leakage To Ground
Standard Must Trip Leakage Current Ratings 7, 10, 15, 30, 50 & 100 milliamps. For other ratings, consult factory.
Trip Time
300 ms Max. @ 100%, 40ms Max. @ 500% of must trip leakage current.
Test Button
On breaker face above actuator.
Leakage Trip Indicator
Red LED on breaker face above actuator.
Number of Poles
Length (included switched
or unswitched neutral)
Width
Depth
Weight: 2-pole
Standard Colors Mounting
Termination
2, 3 & 4
4.2 inches ( 106.7 mm)
2-pole: 3.0 inches (76.2 mm)
3-pole: 3.75 inches (95.3 mm)
4-pole: 4.5 inches (114.3 mm)
2.5inches (63.5mm).
16.0 oz. (453.6 gm)
3-pole: 21.4 oz. (606.7 gm)
4-pole: 26.9 oz. (762.6 gm)
Housing - gray;
Actuator - black, red, or white
Front Panel or Standard 35mm Symmetrical DIN Rail (35 x 7.5 or
35 x 15mm per DIN EN5002).
Box Lug
Environmental
Operating Temperature
+10°C to +50°C
*Manufacturer reserves the right to change product specification without prior notice.
www.carlingtech.com
23
PD-Series – Ordering Scheme
PD R
1
Series
2
System
Voltage/Poles
B
3
Circuit
24
4
Frequency
& Delay
650
5
Current Rating
2 SYSTEM VOLTAGE / POLES1
System Voltage
120VAC 1Ø
A
120/240 VAC 1Ø
B
120/208 VAC 1Ø,
C
120/240 VAC 1Ø
120/208 VAC 1Ø,
D
120/240 VAC 1Ø
208/240 VAC 3Ø
E
208/240 VAC 3Ø
F
208/240 VAC 3Ø
G
480Y VAC 3Ø
P
480Y VAC 3Ø
Q
480Y VAC 3Ø
R
Poles
One plus unswitched neutral
Two
Two plus unswitched neutral
Two plus switched neutral
Three
Three plus unswitched neutral
Three plus switched neutral
Three
Three plus unswitched neutral
Three plus switched neutral
3 CIRCUIT
Series Trip (Current)
4 FREQUENCY & DELAY
20
22
410
512
415
517
420
522
425
527
430
435
440
50/60Hz Instantaneous
50/60Hz Short
24
26
50/60Hz Medium
50/60Hz Long
8
Actuator
9
Actuator
Color
10
Mounting
C
11
Agency
Approval
AMPERES
1.000
1.250
1.500
1.750
2.000
2.250
2.500
2.750
3.000
3.500
4.000
445
450
455
460
465
470
475
480
485
490
495
4.500
5.000
5.500
6.000
6.500
7.000
7.500
8.000
8.500
9.000
9.500
7 TERMINAL
2
Front Connected Box Lug
8 ACTUATOR
A
Handle
B
Handle w/ handleguard
9 ACTUATOR COLOR & LEGEND4
Actuator Color
I-O
ON-OFF
White
A
B
Black
C
D
Red
E
F
Dual
1
2
3
Legend Color
Black
White
White
11 AGENCY APPROVAL
UL Recognized & CSA Certified
C
TUV Certified
U
610
710
611
711
612
712
613
614
615
616
617
10.000
10.500
11.000
11.500
12.000
12.500
13.000
14.000
15.000
16.000
17.000
Time Delay Curves
24
7
Terminal
1
10 MOUNTING3
1 Threaded Insert 6-32 x 0.195 inches
2 Threaded Insert ISO M3 x 6.5 mm
5 CURRENT RATING (AMPERES)
CODE
6
Equipment
Leakage Trip Current
2 A 1
6 EQUIPMENT LEAKAGE - TRIP CURRENT (MILLIAMPS)2
B
7
D
15
F
50
C
10
E
30
G
100
1 SERIES
PD
B
B
618
620
622
624
625
630
635
640
650
18.000
20.000
22.000
24.000
25.000
30.000
35.000
40.000
50.000
Notes:
1 Units with a switched or unswitched neutral connection are the same size as a unit with an additional breaker pole (e.g. a 2-pole unit with a switched or unswitched neutral is the same physical size as a 3-pole unit.)
Switched neutral poles contain the same overcurrent protection as the other poles.
2 The leakage currents shown will cause the breaker to trip (must-trip current). The must-
hold current is 67% of the must-trip current.
3 All breakers are front panel mountable using screw size shown. Breakers may also be mounted on either 35mm x 7.5mm or 35mm x 15mm symmetrical DIN rail.
4 TUV certifed units must have I-O or Dual legends
Instantaneous
Medium
Short
Long
www.carlingtech.com
PD-Series – Circuit & Terminal Diagrams
Notes:
1 All dimensions are in inches [millimeters].
2 Tolerance ±.020 [.51] unless otherwise specified.
Notes:
Other time delay values available, consult factory.
Delay Curves 21,22,24,26: Breakers to hold 100% and must trip at 125%
of rated current and greater within the time limit shown in this curve.
Delay Curve 20: Breakers to hold 100% and must trip at 150% of rated
current and greater within the time limit shown in this curve.
All Curves: Curve data shown represents breaker response at ambient
temperature of 77°F (25°C) with no preloading. Breakers are mounted in
standard wall-mount position.
The minimum inrush pulse tolerance handling capability is 12 times the
rated current. These values are based on a 60 Hz 1/2 cycle, 8.33 ms pulse.
www.carlingtech.com
25
PD-Series – Circuit & Terminal Diagrams
Notes:
1 All dimensions are in inches [millimeters].
2 Tolerance ±.020 [.51] unless otherwise specified.
26
www.carlingtech.com
Literature
Carling also offers several catalogs, covering all our circuit protection and control lines. This complete
line of catalog information, which includes general specs, circuit and terminal drawings, form & fit
drawings and complete ordering information, is available in printed form, as a downloadable PDF
documents from our website. Please visit our website at www.carlingtech.com, scan the QR codes
below or contact any one of our locations to request the following literature:
Switches & Controls
Switches and Controls
Rocker, Toggle, Pushbutton & Rotary
Hydraulic Magnetic
Circuit Protection
Hydraulic/Magnetic Circuit Breakers
This Catalog details the complete line of
Switches and Controls including Rocker,
Toggle, Pushbutton, and Rotary style
switches.
This Catalog highlights the full line of
Hydraulic Magnetic Circuit Breakers.
Breakers from .02 to 700 amps with UL,
CSA, VDE, TUV, UL489, UL489A, UL1500
certifications.
Thermal’s
GFCI’s
Thermal
Circuit Breaker
Ground Fault
Circuit Protection
Reliable, Cost-effective Circuit Protection
This Catalog focuses on the whole line of
Thermal Circuit Breakers. Carling offers a
variety of 3 to 60 amp, lighted and nonlighted, rocker actuator and push-to-reset
push button thermal circuit breakers with
UL, CUL, CE, UL1500/ISO 8846 certifications
www.carlingtech.com
This Catalog features the entire line of
Ground Fault Circuit Breakers. GFCI breakers
range from .10 to 50 amps, and are well
suited for Marine industries use.
27
Literature
On-Off Highway
ON–OFF Highway
Switches & Controls
CATALOG
Marine
Marine Switches,
Circuit Breakers & ELCI/GFCIs
The On-Off Highway Catalog details the list
of applicable products for the transportation
industry. These include the Carling’s V, W, L, S
and N-Series Switches.
The Marine Catalog highlights the list of
applicable products for the marine industry
including switches, circuit breakers, GFCI’s, and
the OctoPlex system.
Military
Renewable Energy
Military Grade
Renewable Energy
Circuit Breakers and Disconnects
COTS SWITCHES & CIRCUIT BREAKERS
The Military Catalog focuses on the list of
applicable products for military uses. These
comprise of sealed rocker, toggle and miniature
switches as well as circuit breakers
The Renewable Energy Catalog features the list
of applicable products for eco-friendly sources
of energy. These are the Carling’s CX, C, G, E, and
F-Series circuit breakers.
Telecom/Datacom
Carlingtech.com
Telecom/Datacom
Circuit Protection
CATALOG
This catalog focuses on the list of applicable
products for the Telecom-Datacom industry. This
features Carling’s L, CX, A, B, C, F and M-Series
circuit breakers.
28
Visit us online for complete products and
company information.
www.carlingtech.com
Notes
www.carlingtech.com
29
Worldwide Headquarters
Carling Technologies, Inc.
60 Johnson Avenue • Plainville, CT 06062
Phone: (860) 793-9281 • Fax: (860) 793-9231
Email: [email protected] • www.carlingtech.com
East Region Sales Office, CT • [email protected]
Midwest Region Sales Office, IL • [email protected]
West Region Sales Office, CA • [email protected]
Asia-Pacific Headquarters
Carling Technologies, Asia-Pacific Ltd.,
Kowloon, Hong Kong
Int + 852-2737-2277 • Fax: Int + 852-2736-9332
Email: [email protected]
Shenzhen, China • [email protected]
Shanghai, China • [email protected]
Pune, India • [email protected]
Kaohsiung, Taiwan • [email protected]
Yokohama, Japan • [email protected]
Europe / Middle East/Africa Headquarters
Carling Technologies, Ltd.,
Devon, England
Int + 44 1392-364422 • Fax: Int + 44 1392-364477
Email: [email protected]
GmbH, Germany • [email protected]
SAS, France • [email protected]
GFCI-C_06_2013