Designed specifically for world market applications, the B-series
utilizes the hydraulic magnetic principle which provides precise
operation and performance even when exposed to extremely
hot and/or cold application environments.
Typical applications include power supplies, medical equipment,
office equipment, control panels and marine equipment. In addition, these breakes meet CSA Standard 22.2 No. 100 for the
Generator & Welder markets.
1-6 poles, 0.02 - 50 amps, up to 277 VAC or 80 VDC, with
choice of time delays, terminals and actuator colors.
Agency Certifications
UL Recognized
UL Standard 1077
CSA Accepted
Component Supplementary
Protector under Class 3215 30,
FIle 047848 0 000 CSA
Standard C22.2 No. 235
TUV Certified
EN60934, under License No.
R72040875
VDE Certified
EN60934, VDE 0642 under File No.
10537
Component Recognition Program
as Protectors Supplementary
(Guide CCN/QVNU2, File E75596)
UL Standard 508
Switches, Industrial Control
(Guide CCN/NRNT2, File E148683)
UL Standard 1500
Protectors, Supplementary for
Marine Electrical & Fuel Systems
(Guide PEQZ2, File E75596)
Ignition Protection
UL Listed
UL Standard 489
Circuit Breakers, Molded Case,
(Guide DIVQ, File E189195)
UL Standard 489A
Communications Equipment (Guide
CCN/DITT, File E189195)
www.carlingtech.com
57
B-Series – General Specifications
Electrical
Table A: Lists UL Recognized & CSA Certified configurations and performance capabilities as a Component Supplementary
Protector.
Notes for Table A:
1
Requires branch circuit backup with a UL LISTED Type K5 or RK5 fuse (15A minimum) at no more than 4 times the rating of the protector.
2
Same as note 1, except that backup fuse is limited to 80A maximum.
3
2 pole protector required (with one pole per power line) for: 250/125 VAC, 125/250 VAC and 208Y/120 VAC Power Systems. 1 pole protector required for : 125 VAC, 1Ø Power System.
58
www.carlingtech.com
B-Series – General Specifications
Electrical
Table B: Lists UL Recognized, CSA, VDE & TUV Certified configurations & performance capabilities as a Component Supplementary
Protector.
Notes for Table B:
1
General Purpose Ratings for UL/CSA Only.
2
Requires branch circuit backup with a UL LISTED Type K5 or RK5 fuse (15A minimum) at no more than 4 times the rating of the protector.
3
Same as note 1, except that backup fuse is limited to 80 A maximum.
Table C: Lists UL Recognized, CSA Certified configurations and performance capabilities as Protectors, Supplementary for
Marine Electrical and Fuel Systems (CCN/Guide PEQZ2, File E75596). Ignition Protected per UL 1500. UL Classified Small Craft
Electrical Devices, Marine in accordance with ISO 8846 (CCN/Guide UZMK, File MQ1515) as Marine Supplementary Protectors.
Notes for Table C:
1
Available with special catalog number only (consult factory).
2
2 pole protector required (with one pole per power line) for: 250/125 VAC, 125/250 VAC and 208Y/120 VAC Power Systems. 1 pole protector required for : 125 VAC, 1Ø Power System.
Table D: Lists UL Listed configurations and performance capabilities as Circuit Breakers for use in Communications Equipment
(CCN/Guide DITT, File E189195), under UL489A
Notes for Table D:
1
60 -90 amp ratings require parallel pole construction
www.carlingtech.com
59
B-Series – General Specifications
Electrical
Maximum Voltage
Current Ratings
Standard Voltage Coils
Auxiliary Switch Rating
Insulation Resistance
Dielectric Strength
Resistance, Impedance
Pulse Tolerance Curves
60
Mechanical
277VAC 50/60 Hz, 80VDC
Standard current coils: 0.100, 0.250,
0.500, 0.750, 1.00, 2.50, 5.00, 7.50,
10.0, 15.0, 20.0, 25.0, 30.0, 35.0,
40.0 and 50.0 amps. Other ratings
available, see ordering scheme.
DC - 6V, 12V; AC - 120V, other ratings available, see ordering scheme.
SPDT; 10.1 AMPS - 250VAC,1.0A
65 VDC or 0.5A 80 VDC, 0.1 Amps 125VAC (with gold contacts).
VDE-1.0 Amp - 125VAC.
Minimum of 100 Megohms at 500
VDC.
UL, CSA - 1500 V 50/60 Hz for one
minute between all electrically isolated terminals. B-Series circuit breakers comply with the 8mm spacing
and 3750V 50/60 Hz dielectric
requirements from hazardous voltage to operator accessible surfaces,
between adjacent poles and from
main circuits to auxiliary circuits per
Publications EN 60950 and VDE
0805.
Values from Line to Load Terminal based on Series Trip Circuit Breaker.
Endurance
Trip Free
Trip Indication
10,000 ON-OFF operations @ 6 per
minute; with rated Current and
Voltage.
All B-Series Circuit Breakers will trip
on overload, even when Handle is
forcibly held in the ON position.
The operating Handle moves positively to the OFF position when an
overload causes the breaker to trip.
Physical
Number of Poles
Internal Circuit Config.
Weight
Standard Colors
1 - 6 poles at 30 Amps or less. 1
and 2 poles at 31 Amps thru 50
Amps.
Series, (with or without auxiliary
switch), Shunt and Relay with current or voltage trip coils, Dual Coil,
Switch Only (with or without auxiliary
switch).
Approximately 65 grams/pole.
(Approximately 2.32 ounces/pole.)
Housing- Black; Actuator - See
Ordering Scheme.
Environmental
Designed and tested in accordance with requirements of specification MIL-PRF- 55629 and MIL-STD-202 as follows:
Shock
Withstands 100 Gs, 6ms, sawtooth
while carrying rated current per
Method 213, Test Condition "I".
Instantaneous and ultra-short curves
tested @ 90% of rated current.
Vibration
Withstands 0.060" excursion from
10-55 Hz, and 10 Gs 55-500 Hz, at
rated current per Method 204C,
Test Condition A. Instantaneous and
ultrashort curves tested at 90% of
rated current.
Moisture Resistance
Method 106D, i.e., ten 24-hour
cycles @ + 25°C to +65°C, 80-98%
RH.
Salt Spray
Method 101, Condition A (90-95%
RH @ 5% NaCl Solution, 96 hrs).
Thermal Shock
Method 107D, Condition A (Five
cycles @ -55°C to +25°C to +85°C
to +25°C).
Operating Temperature
-40° C to +85° C
www.carlingtech.com
B-Series Handle UL Recognized – Ordering Scheme
B A 3 – B 0 – 10 – 450 – 1 B 1 – C
1
Series
2
Actuator
3
Poles
5
Aux/Alarm
Switch
4
Circuit
6
Frequency
& Delay
1 SERIES
B
2 ACTUATOR1
A
Handle, one per pole
B
Handle, one per multipole unit
S
Mid-Trip Handle, one per pole
T
Mid-Trip Handle, one per pole & Alarm Switch
3 POLES
1
One
2
Two
3
4
Three
Four
4 CIRCUIT
A2
Switch Only (No Coil)
B
Series Trip (Current)
C
Series Trip (Voltage)
Shunt Trip (Current)
D3
Shunt Trip (Voltage)
E3
Relay Trip (Current)
F3
G3
H3,4
5 AUXILIARY/ALARM SWITCH5
0
w/o Aux Switch
1
S.P.D.T., 0.093 Q.C. Term.
2
S.P.D.T., 0.110 Q.C. Term.
3
S.P.D.T., 0.139 Solder Lug
4
S.P.D.T., 0.110 Q.C. Term.
(Gold Contacts)
5
6 FREQUENCY & DELAY
032 DC 50/60Hz, Switch Only
106 DC Instantaneous
11
DC Ultra Short
12
DC Short
14
DC Medium
16
DC Long
6
50/60Hz Instantaneous
20
21
50/60Hz Ultra Short
22
50/60Hz Short
24
50/60Hz Medium
26
50/60Hz Long
J3,4
K3,4
6
7
8
9
30
31
32
34
36
427
447
467
527
547
567
5
6
Five
Six
Relay Trip (Voltage)
Dual Coil with Shunt Trip
Voltage Coil
Dual Coil with Shunt Trip
Voltage Coil (side terminal)
Dual Coil with Relay Trip
Voltage Coil
S.P.S.T., 0.093 Q.C.
Term.(Gold Contacts)
S.P.S.T., 0.139 Solder Lug
S.P.S.T., 0.110 Q.C.
Term.(Gold Contacts)
S.P.S.T., 0.187 Q.C. Term.
S.P.D.T., 0.187 Q.C. Term.
DC, 50/60Hz Instantaneous
DC, 50/60Hz Ultra Short
DC, 50/60Hz Short
DC, 50/60Hz Medium
DC, 50/60Hz Long
50/60Hz Short, Hi-Inrush
50/60Hz Medium, Hi-Inrush
50/60Hz Long, Hi-Inrush
DC, Short,Hi-Inrush
DC, Medium, Hi-Inrush
DC, Long, Hi-Inrush
Notes:
1
Actuator Code:
A: Handle tie pin spacer(s) and retainers provided unassembled with multi-pole units.
B: Handle location as viewed from front of breaker:
2 pole - left pole
3 pole - center pole
4 pole - two handles at center poles
5 pole - three handles at center poles
6 pole - four handles at center poles
S: Handle moves to mid-position only upon electrical trip of the breaker. Available with circuit codes B, C, D, E, F, G, H and K.
T: Handle moves to mid-position and alarm switch activates only upon electrical trip of the
breaker. Available with circuit codes B & C.
2
Switch Only circuits, rated up to 50 amps and 6 poles, and only available with VDE
Certification when tied to a protected pole (Circuit Code B, C, D or H.), For .02 to 30
amps, select Current Code 630. For 35 - 50 amps, select Current Code 650.
3
Available with Terminal Codes 1, 2 and 3. Current Rating limited to 30 amps maximum.
4
Consult factory for available Dual Coil options, as special catalog number is required.
With Shunt construction, Dual Coils will trip instantaneously on line voltage. Dual coils
require 30VA minimum power to trip and are rated for intermittent duty only.
5
Auxiliary Switch breakers with Series Trip and Switch Only circuits. On multi-pole breakers, one aux. switch is supplied, mounted in the extreme right pole.
6
Separate pole type voltage coils not rated for continuous duty. Available only with delay
codes 10 and 20.
7
Available with Circuit Codes B & D only. VDE Certified to 30 amps. UL Recognized and
CSA Accepted to 50 amps.
8
VDE Certification available with single pole breakers with DC Delay only. UL Recognition
and CSA Accepted available in one and two pole breakers.
9
Screw Terminals are recommended on ratings greater than 20 amps. Ratings over 30
amps are only available with Terminal Codes 5, 9, G, H, M and Q.
10
VDE Certification up to 25 amps and UL Recognition and CSA Acceptance up to 30
amps, but not recommended over 20 amps.
11
Terminal Codes 3, 5 E and H (Bus Type) with VDE, are supplied with Lock Washers, and
Terminal Code M (M6 Threaded Stud) with VDE is supplied with Lock and Flat Washers.
These breakers are only VDE Certified when the washers are used.
12
VDE Cert. available up to 12 amps. UL Rec. & CSA Acceptance available up to 30 amps.
13
Single pole breakers with Terminal Code P (Printed Circuit Board) are available up to 30
amps with VDE Certification and 50 amps with UL Recognition and CSA Acceptance, with
Circuit Codes A, B and C. Two pole breakers with Terminal Code P (Printed Circuit
Board) are available up to 40 amps with UL Recognition and CSA Acceptance with Circuit
Codes A, B and C.
14
Available with Actuator Codes A, S and T.
15
Available with voltage coils only.
16
Terminal Code Q not available with VDE approvals.
www.carlingtech.com
7
Current Rating
8
Terminal
10
Mounting/
Barriers
9
Actuator
Color
7 CURRENT RATING (AMPERES)
425
2.500
230
0.300
020
0.020
527
2.750
235
0.350
025
0.025
430
3.000
240
0.400
030
0.030
435
3.500
245
0.450
035
0.035
440
4.000
250
0.500
040
0.040
445
4.500
255
0.550
045
0.045
450
5.000
260
0.600
050
0.050
455
5.500
265
0.650
055
0.055
460
6.000
270
0.700
060
0.060
465
6.500
275
0.750
065
0.065
470
280
0.800
070
0.070
7.000
285
0.850
075
0.075
475
7.500
290
0.900
080
0.080
480
8.000
295
0.950
085
0.085
485
8.500
410
1.000
090
0.090
490
9.000
512
1.250
095
0.095
495
9.500
415
1.500
210
0.100
610 10.000
517
1.750
215
0.150
710 10.500
420
2.000
220
0.200
611 11.000
522
2.250
225
0.250
711 11.500
OR VOLTAGE COIL (NOMINAL RATED VOLTAGE)6
J12
12 AC
A32 32 DC
A06
6 DC
J18
18 AC
A48 48 DC
A12 12 DC
J24
24 AC
A65 65 DC
A18 18 DC
J48
48 AC
J06
6 AC
A24 24 DC
8 TERMINAL9
110
Push-On 0.250 Tab (Q.C.)
2
Screw 8-32 w/upturned lugs
11
Screw 8-32 (Bus Type)
3
4
Screw 10-32 w/upturned lugs
11
Screw 10-32 (Bus Type)
5
6
Screw 8-32 w/upturned lugs
and 30° bend
7
Screw 8-32 (Bus Type) and
30° bend
8
Screw 10-32 w/upturned lugs
and 30° bend
9
Screw 10-32 (Bus Type) and
30° bend
B
Screw M5 w/upturned lugs
C
Screw M4 w/upturned lugs
9 ACTUATOR COLOR & LEGEND
I-O
ON-OFF Dual
White A
B
1
Black C
D
2
Red
F
G
3
Green H
J
4
Blue
K
L
5
Yellow M
N
6
Gray
P
Q
7
Orange R
S
8
E11
F
G
H
L12
M11
P13
Q16
R
S15
T
11
Agency
Approval
612
712
613
614
615
616
617
618
620
622
624
625
630
6358
6408
6458
6508
12.000
12.500
13.000
14.000
15.000
16.000
17.000
18.000
20.000
22.000
24.000
25.000
30.000
35.000
40.000
45.000
50.000
J65
65 AC
K20 120 AC
L40 240 AC
Screw M4 (Bus Type)
Screw M5 w/upturned lugs
and 30° bend
Screw M5 (Bus Type)
and 30° bend
Screw M5 (Bus Type)
0.250 Q.C./ Solder Lug
M6 Threaded Studs
Printed Circuit Board
Terminals
Push-In Stud
Screw M4 w/upturned lugs
and 30° bend
Push-On 0.110 Tab (Q.C.)
Screw M4 (Bus Type)
and 30° bend
Legend Color
Black
White
White
White
White
Black
Black
Black
10 MOUNTING/BARRIERS
MOUNTING STYLE
BARRIERS
Threaded Insert, 2 per pole
1
6-32 x 0.195 inches
no
A
6-32 X 0.195 inches (multi-pole units only)
yes
2
ISO M3 x 5mm
no
B
ISO M3 x 5mm
yes
Rectangular Adapter Plate with mounting centers of 2.062”
[52.37mm] and Threaded insert, 2 per pole
314
6-32 x 0.225 inches
no
C14 6-32 X 0.225 inches (multi-pole units only)
yes
14
4
ISO M3 x 6.5mm
no
14
D
ISO M3 x 6.5mm
yes
Front panel Snap-In, 0.75” [19.05mm] wide bezel
5
without Handleguard
no
6
without Handleguard (multi-pole units only)
yes
Front panel Snap-In, 0.96” [24.48mm] wide bezel
7
without Handleguard, 1-pole units 0.96” wide;
no
multipole units have .105“ bezel overhang on all sides
8
without Handleguard, 1-pole units 0.96” wide;
yes
(multi-pole units only) .105“ bezel overhang on all sides
11 AGENCY APPROVAL
C
UL Recognized & CSA Accepted
D
VDE Certified, UL Recognized & CSA Accepted
E
TUV Certified, UL Recognized & CSA Accepted
I
UL Rec. STD 1077, UL Rec. 1500 (ignition protected), & CSA Accepted
61
B-Series Handle UL489A – Ordering Scheme
B A 1 – B 0 – 14 – 450 – 1 B 1 – M T
1
Series
2
Actuator
3
Poles
5
Aux/Alarm
Switch
4
Circuit
6
Frequency
& Delay
1 SERIES
B
2 ACTUATOR1
A
Handle, one per pole
B
Handle, one per multipole unit
S
Mid-Trip Handle, one per pole
T
Mid-Trip Handle, one per pole & Alarm Switch
3 POLES
1 One
2 Two
3 Three
4 Four
4 CIRCUIT
B
Series Trip (Current)
5 AUXILIARY/ALARM SWITCH2
0
w/o Aux Switch
1
S.P.D.T., 0.093 Q.C. Term.
2
S.P.D.T., 0.110 Q.C. Term.
3
S.P.D.T., 0.139 Solder Lug
6 FREQUENCY & DELAY4
11
DC Ultra Short
12
DC Short
14
DC Medium
16
DC Long
7
8
9
S.P.S.T., 0.110 Q.C.
Term.(Gold Contacts)
S.P.S.T., 0.187 Q.C. Term.
S.P.D.T., 0.187 Q.C. Term.
52
54
56
DC, Short,Hi-Inrush
DC, Medium, Hi-Inrush
DC, Long, Hi-Inrush
7 CURRENT RATING (AMPERES)
210
215
220
225
230
235
240
245
250
255
260
265
270
275
280
285
290
295
410
512
0.100
0.150
0.200
0.250
0.300
0.350
0.400
0.450
0.500
0.550
0.600
0.650
0.700
0.750
0.800
0.850
0.900
0.950
1.000
1.250
415
517
420
522
527
430
435
440
445
450
455
460
465
470
475
480
485
490
495
610
1.500
1.750
2.000
2.250
2.750
3.000
3.500
4.000
4.500
5.000
5.500
6.000
6.500
7.000
7.500
8.000
8.500
9.000
9.500
10.000
710
611
711
612
712
613
614
615
616
617
618
620
622
624
625
630
6353
6403
6453
6503
10.500
11.000
11.500
12.000
12.500
13.000
14.000
15.000
16.000
17.000
18.000
20.000
22.000
24.000
25.000
30.000
35.000
40.000
45.000
50.000
Notes:
1
Actuator Code:
A: Handle tie pin spacer(s) and retainers provided unassembled with multi-pole units.
S: Handle moves to mid-position only upon electrical trip of the breaker.
T: Handle moves to mid-position and alarm switch activates only upon electrical trip of the
breaker.
2
On multi-pole breakers, one auxiliary switch is supplied, mounted in the extreme right
pole.
3
VDE Certification available with single pole breakers only. UL489A Listing available with
one and two pole breakers.
4
Screw Terminals are recommended on ratings greater than 20 amps. Ratings over 30
amps are only available with Terminal Codes 5, 9, G, H, M and Q.
5
Terminal Code 1 (Push-On) available up to 25 amps with TUV or VDE Certification and 30
amps with UL489A Listing, but is not recommended over 20 amps.
6
Terminal Codes 3, 5 and H (Bus Type) with TUV or VDE, are supplied with Lock Washers,
and Terminal Code M (M6 Threaded Stud) with TUV or VDE is supplied with Lock and
Flat Washers. These breakers are only TUV or VDE Certified when the washers are
used.
7
Single pole breakers with Terminal Code P (Printed Circuit Board) are available up to 30
amps with VDE Certification and 50 amps with UL489A Listing.
8
Terminal Code Q not available with VDE approvals.
62
7
Current Rating
8
Terminal
9
Actuator
Color
8 TERMINAL4
15
Push-On 0.250 Tab (Q.C.)
2
Screw 8-32 w/upturned lugs
36
Screw 8-32 (Bus Type)
4
Screw 10-32 w/upturned lugs
56
Screw 10-32 (Bus Type)
6
Screw 8-32 w/upturned lugs
and 30° bend
7
Screw 8-32 (Bus Type) and
30° bend
8
Screw 10-32 w/upturned lugs
and 30° bend
9 ACTUATOR COLOR
LEGEND
ON-OFF
White
B
Black
D
Red
G
Green
J
Blue
L
Yellow
N
Gray
Q
Orange
S
Dual
1
2
3
4
5
6
7
8
10
Mounting/
Barriers
9
B
F
G
H
M6
P7
Q8
11
Max. Appl.
Rating
12
Agency
Approval
Screw 10-32 (Bus Type) and
30° bend
Screw M5 w/upturned lugs
Screw M5 w/upturned lugs
and 30° bend
Screw M5 (Bus Type)
and 30° bend
Screw M5 (Bus Type)
M6 Threaded Stud
Printed Circuit Board
Terminals
Push-In Stud
Legend Color
Black
White
White
White
White
Black
Black
Black
10 MOUNTING/BARRIERS
MOUNTING STYLE
BARRIERS
Threaded Insert, 2 per pole
1
6-32 x 0.195 inches
no
A
6-32 X 0.195 inches (multi-pole units only)
yes
2
ISO M3 x 5mm
no
yes
B
ISO M3 x 5mm (multi-pole units only)
Rectangular Adapter Plate with mounting centers of 2.062 inches
and Threaded insert, 2 per pole
3
6-32 x 0.225 inches
no
yes
C
6-32 X 0.225 inches (multi-pole units only)
4
ISO M3 x 6.5mm
no
D
ISO M3 x 6.5mm (multi-pole units only)
yes
Front panel Snap-In, 0.75” wide bezel
5
without Handleguard
no
6
without Handleguard (multi-pole units only)
yes
Front panel Snap-In, 0.96” wide bezel
7
without Handleguard, 1-pole units 0.96” wide;
no
multipole units have .105“ bezel overhang on all sides
8
without Handleguard, 1-pole units 0.96” wide;
yes
(multi-pole units only).105“ bezel overhang on all sides
11 MAXIMUM APPLICATION RATING
M
80 DC
12 AGENCY APPROVAL
T
UL489A Listed
K
UL489A Listed, VDE Certified
J
UL489A Listed, TUV Certified
www.carlingtech.com
B-Series Handle UL489 Listed – Ordering Scheme
B A 1 – B 0 – 24 – 450 – 1 B A – K G
1
Series
2
Actuator
3
Poles
4
Circuit
5
Aux/Alarm
Switch
6
Frequency
& Delay
1 SERIES
B
2 Two
3 Three
3
4 CIRCUIT
B
Series Trip (Current)
5 AUXILIARY/ALARM SWITCH4
0
w/o Aux Switch
1
S.P.D.T., 0.093 Q.C. Term.
2
S.P.D.T., 0.110 Q.C. Term.
6 FREQUENCY & DELAY
21
AC Ultra Short
22
AC Short
24
AC Medium
26
AC Long
3
8
9
S.P.D.T., 0.139 Solder Lug
S.P.S.T., 0.187 Q.C. Term.
S.P.D.T., 0.187 Q.C. Term.
42
44
46
AC, Short,Hi-Inrush
AC, Medium, Hi-Inrush
AC, Long, Hi-Inrush
7 CURRENT RATING (AMPERES)
210
215
220
225
230
235
240
245
250
255
260
265
270
275
280
285
290
295
410
0.100
0.150
0.200
0.250
0.300
0.350
0.400
0.450
0.500
0.550
0.600
0.650
0.700
0.750
0.800
0.850
0.900
0.950
1.000
512
415
517
420
522
527
430
435
440
445
450
455
460
465
470
475
480
485
490
1.250
1.500
1.750
2.000
2.250
2.750
3.000
3.500
4.000
4.500
5.000
5.500
6.000
6.500
7.000
7.500
8.000
8.500
9.000
495
610
710
611
711
612
712
613
614
615
616
617
618
620
622
624
625
630
8
Terminal
9
Actuator
Color
8 TERMINAL5
1
Push-On 0.250 Tab (Q.C.)
2
Screw 8-32 w/upturned lugs
3
Screw 8-32 (Bus Type)
4
Screw 10-32 w/upturned lugs
5
Screw 10-32 (Bus Type)
6
Screw 8-32 w/upturned lugs
and 30° bend
7
Screw 8-32 (Bus Type) and
30° bend
8
Screw 10-32 w/upturned lugs
and 30° bend
2 ACTUATOR1
A
Handle, one per pole
B
Handle, one per mulit-pole unit
S
Mid-Trip Handle, one per pole
T
Mid-Trip Handle, one per pole & Alarm Switch
3 POLES2
1 One
7
Current Rating
9.500
10.000
10.500
11.000
11.500
12.000
12.500
13.000
14.000
15.000
16.000
17.000
18.000
20.000
22.000
24.000
25.000
30.000
9 ACTUATOR COLOR6
LEGEND
ON-OFF
White
B
Black
D
Red
G
Green
J
Blue
L
Yellow
N
Gray
Q
Orange
S
Dual
1
2
3
4
5
6
7
8
10
Mounting/
Barriers
9
A
B
F
G
H
M
Q
11
Max. Appl.
Rating
12
Agency
Approval
Screw 10-32 (Bus Type) and
30° bend
Load Terminal: #8 Screw/QC
Combination. (Special Cat.#)
Screw M5 w/upturned lugs
Screw M5 w/upturned lugs
and 30° bend
Screw M5 (Bus Type)
and 30° bend
Screw M5 (Bus Type)
M6 Threaded Stud
Push-In Stud
Legend Color
Black
White
White
White
White
Black
Black
Black
10 MOUNTING/BARRIERS
MOUNTING STYLE
BARRIERS9
Threaded Insert, 2 per pole
A
6-32 X 0.195 inches
yes
B
ISO M3 x 5mm
yes
Rectangular Adapter Plate with mounting centers of 2.062 inches
7
and Threaded insert, 2 per pole
C
6-32 X 0.225 inches
yes
D
ISO M3 x 6.5mm
yes
Front panel Snap-In, 0.75” wide bezel
6
without Handleguard
yes
Front panel Snap-In, 0.96” wide bezel
8
without Handleguard, 1-pole units 0.96” wide;
yes
.105“ bezel overhang on all sides
11 MAXIMUM APPLICATION RATING
C8
120/240VAC
K
120VAC
12 AGENCY APPROVAL
G
UL489 Listed
3
UL489 Listed, TUV Certified
Notes:
1
Actuator Code:
A: Handle tie pin spacer(s) and retainers provided unassembled with multi-pole units.
B: Handle location as viewed from front of breaker:
2 pole - left pole
3 pole - center pole
S: Handle moves to mid-position only upon electrical trip of the breaker. Available with circuit codes B, C, D, E, F, G, H and K.
T: Handle moves to mid-position and alarm switch activates only upon electrical trip of the
breaker. Available with circuit codes B & C.
2
All poles must be same polarity.
3
3 pole units available only when 1 of 3 poles is neutral.
4
Auxiliary/Alarm Switch circuit must be same polarity as the main circuit. On multi-pole
breakers, one aux. switch is supplied, mounted in the extreme right pole.
5
Screw Terminals are recommended on ratings greater than 20 amps.
6
Standard actuator colors are black and white.
7
Adapter plate with mounting centers of 2.082 inches. Available with Actuator Codes A, S
and T.
8
Voltage Rating available with 2 and 3-pole breakers only.
9
Barriers supplied on multi-pole units only.
www.carlingtech.com
63
B-Series Rocker UL489 Listed – Ordering Scheme
B F 1 – B 0 – 24 – 630 – 2 3 A – K G
1
Series
2
Actuator
3
Poles
5
Aux/Alarm
Switch
4
Circuit
6
Frequency
& Delay
1 SERIES
B
Push-To-Reset, Visi-Rocker
N
Indicate OFF,
vertical legend
O
Indicate OFF,
horizontal legend
Push-To-Reset , Single color
R
Vertical legend
U
Horizontal legend
2 ACTUATOR
Two Color Visi-Rocker
C
Indicate ON,
vertical legend
D
Indicate ON,
horizontal legend
F
Indicate OFF,
vertical legend
G
Indicate OFF,
horizontal legend
Single color
J
Vertical legend
K
Horizontal legend
3 POLES 1,2
1
One
2
3
Two
3
Three
4 CIRCUIT
B
Series Trip (Current)
5 AUXILIARY/ALARM SWITCH 4
0
w/o Aux Switch
1
S.P.D.T., 0.093 Q.C. Term.
2
S.P.D.T., 0.110 Q.C. Term.
3
S.P.D.T., 0.139 Solder Lug
6 FREQUENCY & DELAY
21
AC Ultra Short
22
AC Short
24
AC Medium
26
AC Long
7
8
9
S.P.S.T., 0.110 Q.C.
Term.(Gold Contacts)
S.P.S.T., 0.187 Q.C. Term.
S.P.D.T., 0.187 Q.C. Term.
42
44
46
AC, Short,Hi-Inrush
AC, Medium, Hi-Inrush
AC, Long, Hi-Inrush
Notes:
1
Multi-pole breakers have all breakers identical except when specifying Aux. switch
and/or mixed poles, and have one rocker per breaker.
2
All poles must be same polarity.
3
3 pole units available only when1 of 3 poles is neutral.
4
On multi-pole breakers, one aux. switch is supplied, mounted in the extreme right pole.
5
Screw Terminals are recommended on ratings greater than 20 amps.
6
Terminal Code 1 (Push-On) available up to 30 amps, but are not recommended over 20
amps.
7
Dual legend = ON-OFF/I-O
8
Voltage Rating available with 2 and 3-pole breakers only.
9
Barriers supplied on multi-pole units only.
64
7
Current Rating
8
Terminal
9
Actuator
Color
7 CURRENT RATING (AMPERES)
280
0.800
210
0.100
285
0.850
215
0.150
290
0.900
220
0.200
295
0.950
225
0.250
410
1.000
230
0.300
512
1.250
235
0.350
415
1.500
240
0.400
517
1.750
245
0.450
420
2.000
250
0.500
522
2.250
255
0.550
527
2.750
260
0.600
430
3.000
265
0.650
435
3.500
270
0.700
440
4.000
275
0.750
8 TERMINAL 5
16
Push-On 0.250 Tab (Q.C.)
2
Screw 8-32 w/upturned lugs
3
Screw 8-32 (Bus Type)
4
Screw 10-32 w/upturned lugs
5
Screw 10-32 (Bus Type)
6
Screw 8-32 w/upturned lugs
and 30° bend
7
Screw 8-32 (Bus Type) and
30° bend
8
Screw 10-32 w/upturned lugs
and 30° bend
9 ACTUATOR COLOR & LEGEND
Actuator or
Marking
Visi-Color 7
ON-OFF
Dual7
White
B
1
Black
D
2
Red
G
3
Green
J
4
Blue
L
5
Yellow
N
6
Gray
Q
7
Orange
S
8
10 MOUNTING/BARRIERS
STANDARD ROCKER BEZEL
Threaded Insert, 2 per pole
A
6-32 X 0.195 inches
B
ISO M3 x 5mm
ROCKERGUARD BEZEL
Threaded Insert, 2 per pole
C
6-32 x 0.195 inches
D
ISO M3 x 5mm
10
Mounting/
Barriers
12
11
Max. Appl. Agency
Approval
Rating
711
612
712
613
614
615
616
617
618
620
622
624
625
630
11.500
12.000
12.500
13.000
14.000
15.000
16.000
17.000
18.000
20.000
22.000
24.000
25.000
30.000
445
450
455
460
465
470
475
480
485
490
495
610
710
611
4.500
5.000
5.500
6.000
6.500
7.000
7.500
8.000
8.500
9.000
9.500
10.000
10.500
11.000
9
Screw 10-32 (Bus Type) and
30° bend
Screw M5 w/upturned lugs
Screw M4 w/upturned lugs
Screw M5 w/upturned lugs
and 30° bend
Screw M5 (Bus Type)
and 30° bend
Screw M5 (Bus Type)
B
C
F
G
H
Marking Color:
Single Color
Visi-Rocker
Black
White
White
n/a
White
Red
White
Green
White
Blue
Black
Yellow
Black
Gray
Black
Orange
BARRIERS9
yes
yes
yes
yes
11 MAXIMUM APPLICATION RATING
C8
120/240 VAC
K
120 VAC
11 AGENCY APPROVAL
G
UL489 Listed
www.carlingtech.com
B-Series Flat Rocker UL489 Listed – Ordering Scheme
B 1 1 – B 0 – 24 – 630 – 2 3 A – K G
1
Series
2
Actuator
3
Poles
5
Aux/Alarm
Switch
4
Circuit
6
Frequency
& Delay
2 ACTUATOR 1
Two Color Visi-Rocker
1
Indicate OFF, vertical legend
2
Indicate OFF, horizontal legend
Single color
3
Vertical legend
4
Horizontal legend
Push-To-Reset, Visi-Rocker
5
Indicate OFF, vertical legend
6
Indicate OFF, horizontal legend
Push-To-Reset , Single color
7
Vertical legend
8
Horizontal legend
2
4
Two
3
Three
4 CIRCUIT
B
Series Trip (Current)
5 AUXILIARY/ALARM SWITCH 5
0
w/o Aux Switch
1
S.P.D.T., 0.093 Q.C. Term.
2
S.P.D.T., 0.110 Q.C. Term.
3
S.P.D.T., 0.139 Solder Lug
6 FREQUENCY & DELAY
21
AC Ultra Short
22
AC Short
24
AC Medium
26
AC Long
8
Terminal
9
Actuator
Color
7 CURRENT RATING (AMPERES)
280
0.800
210
0.100
285
0.850
215
0.150
290
0.900
220
0.200
295
0.950
225
0.250
410
1.000
230
0.300
512
1.250
235
0.350
415
1.500
240
0.400
517
1.750
245
0.450
420
2.000
250
0.500
522
2.250
255
0.550
527
2.750
260
0.600
430
3.000
265
0.650
435
3.500
270
0.700
440
4.000
275
0.750
1 SERIES
B
3 POLES 2,3
1
One
7
Current Rating
7
8
9
42
44
46
S.P.S.T., 0.110 Q.C.
Term.(Gold Contacts)
S.P.S.T., 0.187 Q.C. Term.
S.P.D.T., 0.187 Q.C. Term.
AC, Short,Hi-Inrush
AC, Medium, Hi-Inrush
AC, Long, Hi-Inrush
8 TERMINAL 6
17
Push-On 0.250 Tab (Q.C.)
2
Screw 8-32 w/upturned lugs
3
Screw 8-32 (Bus Type)
4
Screw 10-32 w/upturned lugs
5
Screw 10-32 (Bus Type)
6
Screw 8-32 w/upturned lugs
and 30° bend
7
Screw 8-32 (Bus Type) and
30° bend
8
Screw 10-32 w/upturned lugs
and 30° bend
9 ACTUATOR COLOR & LEGEND
Actuator or
Marking
Visi-Color 8
ON-OFF
Dual8
White
B
1
Black
D
2
Red
G
3
Green
J
4
Blue
L
5
Yellow
N
6
Gray
Q
7
Orange
S
8
10
Mounting/
Barriers
12
11
Max. Appl. Agency
Approval
Rating
711
612
712
613
614
615
616
617
618
620
622
624
625
630
11.500
12.000
12.500
13.000
14.000
15.000
16.000
17.000
18.000
20.000
22.000
24.000
25.000
30.000
445
450
455
460
465
470
475
480
485
490
495
610
710
611
4.500
5.000
5.500
6.000
6.500
7.000
7.500
8.000
8.500
9.000
9.500
10.000
10.500
11.000
9
Screw 10-32 (Bus Type) and
30° bend
Screw M5 w/upturned lugs
Screw M4 w/upturned lugs
Screw M5 w/upturned lugs
and 30° bend
Screw M5 (Bus Type)
and 30° bend
Screw M5 (Bus Type)
B
C
F
G
H
Marking Color:
Single Color
Visi-Rocker
Black
White
White
n/a
White
Red
White
Green
White
Blue
Black
Yellow
Black
Gray
Black
Orange
10 MOUNTING/BARRIERS9
BARRIERS12
STANDARD ROCKER BEZEL,Threaded Insert, 2 per pole
FLAT ROCKER ACTUATOR
A 6-32 X 0.195 inches
yes
B ISO M3 x 5mm
yes
RECESSED OFF SIDE ROCKER ACTUATOR 10
E 6-32 x 0.195 inches
yes
F ISO M3 x 5mm
yes
PUSH-TO-RESET BEZEL,Threaded Insert, 2 per pole
C 6-32 x 0.195 inches
yes
D ISO M3 x 5mm
yes
Notes:
1
Push-To-Reset actuators have OFF portion of rocker shrouded.
2
Multi-pole breakers have all breakers identical except when specifying Aux. switch
and/or mixed poles, and have one rocker per breaker.
3
All poles must be same polarity.
4
3 pole units available only when1 of 3 poles is neutral.
5
On multi-pole breakers, one aux. switch is supplied, mounted in the extreme right pole.
6
Screw Terminals are recommended on ratings greater than 20 amps.
7
Terminal Code 1 (Push-On) available up to 30 amps, but are not recommended over 20
amps.
8
Color shown is visi and legend with remainder of rocker black, Dual = ON-OFF/I-O legend.
9
Legend on Push-to-reset bezel/shroud is white with single color actuator codes 7 & 8.
Legend on Push-To-Reset bezel/shroud matches Visi-Color of rocker with actuator
codes 5 & 6.
10
Recessed “off-side” available with actuator codes 1, 2, 3 & 4. Legends on rocker are
available in ink stamping only.
11
Voltage rating available with 2 & 3-pole breakers only.
12
Barriers supplied on multi-pole units only.
www.carlingtech.com
11 MAXIMUM APPLICATION RATING
C11 120/240 VAC
K
120 VAC
12 AGENCY APPROVAL
G
UL489 Listed
65
B-Series Handle – Circuit & Terminal Diagrams
Notes:
1
All dimensions are in inches [millimeters].
2
Tolerance ±.020 [.51] unless otherwise specified.
3
Alarm Switch available with .110 x .020 Q.C. & Solder Lug Terminals Only.
66
www.carlingtech.com
B-Series Handle – Circuit & Terminal Diagrams
Notes:
1
All dimensions are in inches [millimeters].
2
Tolerance ±.020 [.51] unless otherwise specified.
www.carlingtech.com
67
B-Series Handle – Front Panel Snap-In Mounting Style 5
Notes:
1
All dimensions are in inches [millimeters].
2
Tolerance ±.020 [.51] unless otherwise specified.
68
www.carlingtech.com
B-Series Handle – Front Panel Snap-in Mounting Style 5
Notes:
1
All dimensions are in inches [millimeters].
2
Recommended panel thickness: .040 [1.02] to .100 [2.54].
3
Tolerance ±.020 [.51] unless otherwise specified.
www.carlingtech.com
69
B-Series Handle – Front Panel Snap-In Mounting Style 7
Notes:
1
All dimensions are in inches [millimeters].
2
Recommended panel thickness .040 [1.02] to .100 [2.54].
3
Tolerance ±.020 [.51] unless otherwise specified.
70
www.carlingtech.com
B-Series PC Terminal Diagrams
Notes:
1
All dimensions are in inches [millimeters].
2
For pole orientation with horizontal legend, rotate front view clockwise 90°.
3
Tolerance ±.010 [.25] unless otherwise specified.
www.carlingtech.com
71
B-Series Rocker UL489 Listed – Form & Fit Drawings
Notes:
1
Dimensions apply to all variations shown. Notice that circuit breaker line & load terminal
orientation on indicate “OFF” is opposite of indicate “ON”.
2
For pole orientation with horizontal legend, rotate front view clockwise 90°.
3
All dimensions are in inches [millimeters].
4
Tolerance ±.020 [.51] unless otherwise specified.
72
www.carlingtech.com
B-Series Flat Rocker UL489 Listed – Form & Fit Drawings
Notes:
1
All dimensions are in inches [millimeters].
2
For pole orientation with horizontal legend, rotate front view clockwise 90°.
3
Tolerance ±.020 [.51] unless otherwise specified.
www.carlingtech.com
73