C-Series C-Series CIRCUIT BREAKER The C-Series hydraulic-magnetic circuit breakers are ideal for applications that require higher amperage and voltage handling capability in a smaller package. They are available in 1-6 poles, 0.02-100amps, UL Recognized up to 480VAC or 150VDC, UL489 Listed up to 240VAC or 125VDC, with choice of time delays, terminal options, actuator styles and colors. The C-Series employs a unique arc chute design which allows for higher interrupting capacities of up to 10,000 amps. New thermoset glass filled polyester half shell construction provides for increased mechanical and electrical strength. The wiping contacts, mechanical linkage with two step actuation, clean contacts providing high, positive contact pressure and longer contact life. Available with American Standard or Metric Threaded Stud terminals, or Saddle Clamp screw terminals. The optional mid-trip handle style actuator allows a visual indication of electrical overload with or without alarm feature. Product Highlights: Extensive list of Agency Approvals Available with Standard or Metric Stud terminals, or Saddle Clamp screw terminals Optional mid-trip handle style actuator Unique arc chute design which allows for higher interrupting capacities of up to 10,000 amps Exclusive Rockerguard and Push-To-Reset bezel Available with new solid color and two-color Visirocker® actuators New thermoset glass filled polyester half shell construction Typical Applications: Marine Telecom/Datacom Military Renewable Energy Generators & Welders Carling Technologies, Inc. 60 Johnson Avenue, Plainville, CT 06062 Email: [email protected] Application Support: [email protected] Phone: 860.793.9281 Fax: 860.793.9231 www.carlingtech.com 2 | C-Series Circuit Breaker - General Specifications Electrical Maximum Voltage AC, 480 WYE/277 VAC, 50/60 Hz (see Table A.) UL489: AC,240 VAC. (See Table D), 50/60 Hz, 125 VDC Current Rating Standard current coils: 0.100, 0.250, 0.500, 0.750, 1.00, 2.50, 5.00, 7.50, 10.0, 15.0, 25.0, 30.0, 35.0, 40.0, 50.0, 60.0, 70.0, 80.0, 90.0 and 100 amps. Other ratings available, see Ordering Scheme. Standard Voltage Coils DC - 6V, 12V; AC - 120V; other ratings available, see Ordering Scheme. Auxiliary Switch Rating SPDT; 10.1 amps-250VAC, DC Aux. Switch 1.0A, 65 VDC. 0.5A, 80VDC,1/4 HP, 125VAC,VDE & TUV 1.0 125 VAC. Insulation Resistance Minimum of 100 Megohms at 500 VDC. Dielectric Strength UL, CSA: 1960 V 50/60 Hz for one minute between all electrically isolated terminals. C-Series Circuit Breakers comply with the 8mm spacing and 3750V 50/60 Hz dielectric requirements from hazardous voltage to operator accessible surfaces, between adjacent poles and from main circuits to auxiliary circuits per Publications EN 60950 and VDE 0805. Resistance, Impedance Values from Line to Load Terminal based on Series Trip Circuit Breaker. Mechanical Endurance 10,000 ON-OFF operations @ 6 per minute; with rated current & voltage. Trip Free All C-Series circuit breakers will trip on overload, even when actuator is forcibly held in the ON position. Trip Indication The operating actuator moves positively to the OFF position when an overload causes the breaker to trip. With mid-trip, handle moves to the mid position on electrical trip of the circuit breaker. With mid trip handle with alarm switch, handle moves to the mid position and the alarm switch actuates when the circuit breaker is electrically tripped. Physical Number of Poles Internal Circuit Config. Weight Standard Colors 1-6 poles ≤ 50A; 1-4 poles @ 5170A; 1-2 poles 71-100A. UL489 Handle: 1 pole ≤ 100A, 2 pole ≤ 50A; Rocker: 1 pole ≤ 100A. Series (with or without auxiliary switch, mid trip & mid trip with alarm switch) Shunt & Relay with current or voltage trip coils, Dual Coil, Switch Only (with or without aux. switch). UL489: Series (with or without auxiliary switch, mid-trip & midtrip with alarm switch). Approx.112 grams/pole ( 3.95 oz). Housing: Black RESISTANCE, IMPEDANCE VALUES from Line to Load Terminals (Values Based on Series Trip Circuit Breaker ) 1000 CURRENT TOLERANCE (AMPS) (%) 0.10 - 5.0 5.1 - 20.0 15 25 20.1 - 50.0 35 100 10 O H M S 1 60 Hz 1/2 Cycle Inrush Pulse Tolerance 0.1 Multiple of Rated Current Ir 0.01 0.001 0.01 0.1 1 10 Time Delay Curves 42, 44 & 46 (50 Amps Max.) 25x Time Delay Curves 22, 24 (100 Amps Max.) 26 (70 Amps Max.) 12x 100 t AMPERE RATING 4.165 8.33 16.67 Pulse Tolerance Curves CURRENT (AMPS) TOLERANCE (%) 0.100 - 5.0 15% 60 Hz5.1 1/2- 20.0 Cycle 20.1 -Tolerance 100 Inrush Pulse 25% 35% Ir FIGURE Time Delay Curves 1 Multiple of Rated Current Multiple of Rated Current Ir 42, 44 & 46 (50 Amps Max.) 25x Time Delay Curves 22, 24 (100 Amps Max.) 26 (70 Amps Max.) 12x Time Delay Curves 42, 44 & 46 (50 Amps Max.) 22x Time Delay Curves 22, 24 (100 Amps Max.) 26 (70 Amps Max.) 10x t t 4.165 Ir Multiple of Rated Current 50 Hz 1/2 Cycle Inrush Pulse Tolerance 8.33 5.0 10.0 16.67 50 Hz 1/2 Cycle Inrush Pulse Tolerance Time Delay Curves 42, 44 & 46 (50 Amps Max.) 22x Time Delay Curves 22, 24 (100 Amps Max.) 26 (70 Amps Max.) 10x 20.0 Time in Milliseconds Environmental Designed and tested in accordance with requirements of specification MIL-PRF-55629 & MIL-STD-202 as follows: Shock Withstands 100 Gs, 6ms sawtooth while carrying rated current per Method 213, Test Condition “I”. Instantaneous and ultrashort curves tested @ 90% of rated current. Vibration Withstands 0.060” excursion from 10-55 Hz & 10 Gs 55-500 Hz, @ rated current per Method 204C, Test Cond. A. Instantaneous & ultrashort curves tested @ 90% of rated current. Moisture Resistance Method 106D, i.e., ten 24-hour cycles @ +25°C to +65°C, 80-98% RH. Salt Spray Method 101, Condition A (90-95% RH @ 5% NaCl Solution, 96 hrs). Thermal Shock Method 107D, Condition A (five cycles @ -55°C to +25°C to +85°C to +25°C). Operating Temperature -40°C to +85°C t 5.0 10.0 20.0 *Manufacturer reserves the right to change product specification without prior notice. Time in Milliseconds Email: [email protected] Application Support: [email protected] Phone: (860) 793–9281 Fax: (860) 793–9231 www.carlingtech.com C-Series Circuit Breaker - General Specifications | 3 Electrical Tables Table A: Lists UL Recognized & CSA Accepted configurations and performance capabilities as a Component Supplementary Protector C-SERIES TABLE A: COMPONENT SUPPLEMENTARY PROTECTORS VOLTAGE CIRCUIT CONFIGURATION SERIES CURRENT RATING FREQUENCY PHASE FULL LOAD AMPS 32 DC --- 0.02 - 100 --- --- 48 DC --- 110 - 150 --- --- 65 DC --- 0.02 - 70 --- 80 DC --- 80 DC --- 125 DC 125 / 250 250 NOTES UL CSA 5000 TC1, OL1, U2 TC1, OL1, U2 5000 TC1, OL1, U2 TC1, OL1, U2 --- 5000 TC1,2, OL1,U1 TC1,2, OL1,U1 --- 71 -100 --- 5000 TC1,2, OL0,U1 TC1,2, OL0,U1 0.02 - 70 --- --- 7500 TC1,2, OL1,U1 TC1,2, OL1,U1 --- 71 -100 --- 7500 TC1,2, OL0,U1 TC1,2, OL0,U1 0.02 - 70 --- --- 10,000 TC1,2, OL1,U1 TC1,2, OL1,U1 Must Have Agency Code "L" --- 71 -100 --- 10,000 TC1,2, OL0,U1 TC1,2, OL0,U1 Must Have Agency Code "L" --- 0.02 - 50 --- 5000 TC1,2,OL1,U1 TC1,2,OL1,U1 DC --- 0.02 - 50 --- 5000 TC1,2,OL1,U1 TC1,2,OL1,U1 Must Have Agency Code "L" DC --- 0.02 - 50 --- 5000 TC1,2,OL1,U1 TC1,2,OL1,U1 Must Have Agency Code "L". 2 Pole Break Required for 250 Volts 0.02 - 100 --- --- 3000 TC1, OL1, U2 TC1, OL1, U2 Per Pole Rating 0.02 - 100 --- --- 5000 TC1,2,OL1,U1 TC1,2,OL1,U1 Must Have Agency Code "L" Must Have Agency Code "L" 50 / 60 1 150 DC --- --- 80 - 100 --- 5000 TC1, OL0, U3 --- Must Have Agency Code "L" 150 DC --- --- 101 - 175 --- 5000 TC1, OL0, U3 --- Must Have Agency Code "L" Parallel Pole 0.02 - 100 --- --- 3500 TC1, OL1, U2 TC1, OL1, U2 125 / 250 50 / 60 1 0.02 - 50 --- --- 3000 TC1,2,OL1,U1 TC1,2,OL1,U1 51 - 100 --- --- 1000 TC1,2,OL1,U1 TC1,2,OL1,U1 2 or 3 poles breaking single phase 0.02 - 100 --- --- 5000 TC1,2,OL1,U2 TC1,2,OL1,U2 2 or 3 poles breaking single phase, "L" Agency Code 0.02 - 50 --- --- 3500 TC1, OL1, U2 TC1, OL1, U2 Per Pole Rating 0.02 - 100 --- --- 5000 TC1,2,OL1,U1 TC1,2,OL1,U1 Must Have Agency Code "L" 51 - 70 --- 5000 --- TC1,2,OL1,C1 TC1,2,OL1,C1 --- 0.02 - 100 --- 3000 TC1, OL0, U2 TC1, OL0, U2 0.02 - 70 --- 5000 --- TC1,2,OL1,C1 TC1,2,OL1,C1 3 poles breaking 3 phase --- 0.02 - 90 --- 5000 TC1,2,OL0,U1 TC1,2,OL0,U1 Must Have Agency Code "L" 0.02 - 50 --- 5000 --- TC1,2,OL1,C1 TC1,2,OL1,C1 0.02 - 30 --- 5000 --- TC1,2,OL1,C1 TC1,2,OL1,C1 --- 31 - 50 5000 --- TC1,2,OL0,C1 TC1,2,OL0,C1 50 / 60 3 277 50 / 60 1 480 / 277 50 / 60 3 480 50 / 60 1 0.02 - 30 --- 5000 --- TC1,2,OL1,C1 TC1,2,OL1,C1 --- 31 - 50 5000 --- TC1,2,OL0,C1 TC1,2,OL0,C1 TC1,2, OL1,U1 2 or 3 poles breaking single phase 3 poles breaking 3 phase 2 poles breaking 1 phase 80 DC --- 0.02 - 50 --- --- 7500 TC1,2, OL1,U1 125 50 / 60 1 0.02 - 50 --- --- 3000 TC1, OL1, U2 TC1, OL1, U2 Per Pole Rating 125 / 250 50 / 60 1 0.02 - 50 --- --- 3500 TC1, OL1, U2 TC1, OL1, U2 2 or 3 poles breaking single phase 0.02 - 50 --- --- 3000 TC1,2,OL1,U1 TC1,2,OL1,U1 2 or 3 poles breaking single phase 0.02 - 50 --- --- 3500 TC1, OL1, U2 TC1, OL1, U2 250 50 / 60 0.02 - 50 --- --- 3000 TC1, OL0, U2 TC1, OL0, U2 0.02 - 50 --- 5000 --- TC1,2,OL1,C1 TC1,2,OL1,C1 DUAL COIL SWITCH ONLY APPLICATION CODES 125 250 RELAY UL/CSA WITH BACKUP WITHOUT BACKUP GENERAL PURPOSE AMPS FUSE FUSE 1 MAX. RATING 1 SHUNT SHORT CIRCUIT CAPACITY (AMPS) 1 3 277 50 / 60 1 0.02 - 50 --- 5000 --- TC1,2,OL1,C1 TC1,2,OL1,C1 80 DC --- 0.02 - 50 --- --- 7500 TC1,2, OL1,U1 TC1,2, OL1,U1 Per Pole Rating 3 poles breaking 3 phase 277 50 / 60 1 0.02 - 50 --- 5000 --- TC1,2,OL1,C1 TC1,2,OL1,C1 250 50 / 60 3 0.02 - 50 --- 5000 --- TC1,2,OL1,C1 TC1,2,OL1,C1 3 poles breaking 3 phase 480 / 277 50 / 60 3 0.02 - 30 --- 5000 --- TC1,2,OL1,C1 TC1,2,OL1,C1 3 poles breaking 3 phase TC1,2,OL0,C1 480 50 / 60 1 --- 31 - 50 5000 --- TC1,2,OL0,C1 0.02 - 30 --- 5000 --- TC1,2,OL1,C1 TC1,2,OL1,C1 --- 31 - 50 5000 --- TC1,2,OL0,C1 TC1,2,OL0,C1 TC1,2, OL1,U1 80 DC --- 0.02 - 50 --- --- 7500 TC1,2, OL1,U1 277 50 / 60 1 0.02 - 50 --- 5000 --- TC1,2,OL1,C1 TC1,2,OL1,C1 250 50 / 60 3 0.02 - 50 --- 5000 --- TC1,2,OL1,C1 TC1,2,OL1,C1 65 DC --- 0.02 - 70 --- --- --- --- --- 80 DC --- 125 50 / 60 125 / 250 50 / 60 250 50 / 60 277 50 / 60 480 / 277 50 / 60 --- 71 -100 --- --- --- --- 0.02 - 70 --- --- --- --- --- --- 71 -100 --- --- --- --- 1 0.02 - 100 --- --- --- --- --- 1 0.02 - 100 --- --- --- --- --- 1 0.02 - 100 --- --- --- --- --- 3 0.02 - 70 --- --- --- --- --- 1 0.02 - 50 --- --- --- --- --- 0.02 - 30 --- --- --- --- --- --- 31 - 50 --- --- --- --- 3 2 poles breaking 1 phase 3 poles breaking 3 phase 2 or 3 poles breaking single phase 3 poles breaking 3 phase Notes: 1. Requires branch circuit backup with a UL LISTED Type K5 or RK5 fuse rated 15A minimum and no more than 4 times full load amps not to exceed 125A for 50 Amp or less rating and not to exceed 175 for 51 through 100 Amp rating Email: [email protected] Application Support: [email protected] Phone: (860) 793–9281 Fax: (860) 793–9231 www.carlingtech.com 4 | C-Series Circuit Breaker - General Specifications Electrical Tables Table B: Lists UL Recognized and CSA Accepted configurations and performance capabilities as a Manual Motor Controller. RELAY Notes: 1 UL recognized and CSA Accepted at 480V refers to 3 & 4 pole versions used in a 3Ø, wye connected circuit or 2-pole version connected with 2 poles breaking. 1Ø and backed up with series fusing as stated above in note 1. * Series, Shunt and Relay Trip - Voltage Coil Construction not current coils Table C: Lists UL Recognized, CSA Accepted, VDE and TUV Certified configurations and performance capabilities as a Component Supplementary Protector. Notes: 1. General Purpose ratings for UL/CSA only. 2. Requires branch circuit backup with a UL LISTED Type K5 or RK5 fuse rated 15A minimum and no more than 4 times full load amps not to exceed 125A for 50 Amp or less rating and not to exceed 175 for 51 through 100 Amp rating. Table D: Lists UL Listed (489), CSA Certified (C22.2 No. 5.1-M) configuration and performance capabilities as a Molded Case Circuit Breaker. C SERIES TABLE D : UL489 LISTED BRANCH CIRCUIT BREAKERS CIRCUIT CONFIGURATION SERIES DUAL COIL INTERRUPTING CAPACITY (AMPS) WITHOUT FULL LOAD BACKUP FUSE AMPS CURRENT RATING VOLTAGE CONSTRUCTION NOTES MAX. RATING FREQUENCY PHASE 80 DC --- 0.10 - 100 125 DC --- 0.10 - 100 5,000 1 - 3 Poles 125 / 250 DC --- 0.10 - 50 5,000 1 or 2 Poles (2 Poles Required for 250 Volts) 120 50 / 60 1 0.10 - 50 10,000 1 - 3 Poles 51 - 70 5,000 1 - 3 Poles 0.10 - 50 5,000 2 or 3 Poles. 1 Pole of a 3 Pole Unit is Neutral 50,000 1 Limited to 2 Poles Max from 71 - 100 Amps. 10,000 Limited to 2 Poles Max from 71 - 100 Amps. 120 / 240 50 / 60 1 0.10 - 50 10000 1 2 or 3 Poles. 1 Pole of a 3 Pole Unit is Neutral 240 50 / 60 1 0.10 - 30 5,000 1Pole 240 50 / 60 1 0.10 - 20 5,000 2 Pole 277 50 / 60 1 0.10 - 20 10,000 1Pole 120 50 / 60 1 0.10 - 30 10,000 --- Notes from Table D: 1. Special catalog number required. Consult factory. Email: [email protected] Application Support: [email protected] Phone: (860) 793–9281 Fax: (860) 793–9231 www.carlingtech.com C-Series Circuit Breaker - General Specifications | 5 Electrical Tables Table E: Lists UL Recognized, CSA Accepted configurations and performance capabilities as Protectors, Supplementary for Marine Electrical and Fuel Systems (Guide PEQZ2, File E75596). Ignition Protected per UL 1500. UL Classified Small Craft Electrical Devices, Marine in accordance with ISO 8846 (Guide UZMK, File MQ1515) as Marine Supplementary Protectors. Table F: Lists UL Listed configurations and performance capabilities as Circuit Breakers for use in Communications Equipment (Guide DITT, File E189195), under UL489A. Agency Certifications UL Recognized UL Standard 1077 Component Recognition Program as Protectors Supplementary (Guide CCN/QVNU2, File E75596) CSA Accepted Component Supplementary Protector under Class 3215 30, FIle 047848 0 000 CSA Standard C22.2 No. 235 UL Standard 508 Switches, Industrial Control (Guide CCN/NRNT2, File E148683) CSA Certified UL Standard 1500 Protectors, Supplementary for Marine Electrical & Fuel Systems (Guide PEQZ2, File E75596) Ignition Protection Circuit Breaker Model Case (Class 1432 01, File 093910), CSA Standard C22.2 No. 5.1 - M TUV Certified EN60934, under License No. R72040875 Circuit Breakers, Molded Case, (Guide DIVQ, File E129899) VDE Certified EN60934, VDE 0642 under File No. 10537 UL Listed UL Standard 489 UL Standard 489A Communications Equipment (Guide CCN/DITT, File E189195) Email: [email protected] Application Support: [email protected] Phone: (860) 793–9281 Fax: (860) 793–9231 www.carlingtech.com 6 | C-Series Circuit Breaker - Handle UL Recognized – Ordering Scheme C A 3 1 Series 2 Actuator B 0 4 Circuit 3 Poles 10 5 Aux/Alarm Switch 6 Frequency & Delay 1 SERIES C 9 Actuator Color C 10 Mounting Bezel/Barrier 11 Agency Approval CODEAMPERES Handle, one per pole Handle, one per multipole unit Mid-Trip Handle, one per pole Mid-Trip Handle, one per pole & Alarm Switch 3 POLES 2 1 One 2 Two 1 2 1 8 Terminal 7 CURRENT RATING (AMPERES) 2 ACTUATOR 1 A B S T 450 7 Current Rating 3 4 Three Four 4 CIRCUIT 3 A 3 Switch Only (No Coil) B Series Trip (Current) C Series Trip (Voltage) 4 D Shunt Trip (Current) 4 E Shunt Trip (Voltage) 5 6 Five Six F 4 Relay Trip (Current) G 4 Relay Trip (Voltage) H 4,5 Dual Coil with Shunt Trip Voltage Coil K 4,5 Dual Coil with Relay Trip Voltage Coil 0200.020 2350.350 4303.000 0250.025 2400.400 4353.500 0300.030 2450.450 4404.000 0350.035 2500.500 4454.500 0400.040 2550.550 4505.000 0450.045 2600.600 4555.500 0500.050 2650.650 4606.000 0550.055 2700.700 4656.500 0600.060 2750.750 4707.000 0650.065 2800.800 4757.500 0700.070 2850.850 4808.000 0750.075 2900.900 4858.500 0800.080 2950.950 4909.000 0850.085 4101.000 4959.500 0900.090 5121.250 610 10.000 0950.095 4151.500 71010.500 2100.100 517 1.750 611 11.000 2150.150 4202.000 71111.500 2200.200 5222.250 61212.000 2250.250 4252.500 71212.500 2300.300 5272.750 61313.000 OR VOLTAGE COIL (NORMAL RATED VOLTAGE) 7 61414.000 61515.000 61616.000 61717.000 61818.000 62020.000 62222.000 62424.000 62525.000 63030.000 635 35.000 640 40.000 65050.000 660 960.000 670 970.000 680 980.000 685 985.000 690 990.000 695 995.000 810 9100.00 A06 6 DC A12 12 DC A18 18 DC A24 24 DC J65 65 AC K20 120 AC L40 240 AC CODEAMPERES 5 AUXILIARY / ALARM SWITCH 0 without Aux Switch 2 S.P.D.T., 0.110 Q.C. Term. 3 S.P.D.T., 0.139 Solder Lug 4 S.P.D.T., 0.110 Q.C. Term. (Gold Contacts) 6 FREQUENCY & DELAY 03 3 DC 50/60Hz, Switch Only 10 7 DC Instantaneous 11 DC Ultra Short 12 DC Short 14 DC Medium 16 DC Long 20 7 50/60Hz Instantaneous 21 50/60Hz Ultra Short 22 50/60Hz Short 24 50/60Hz Medium 26 50/60Hz Long 6 8 9 30 31 32 34 36 42 8 44 8 46 8 52 8 54 8 56 S.P.S.T., 0.139 Solder Lug S.P.S.T., 0.187 Q.C. Term. S.P.D.T., 0.187 Q.C. Term. DC 50/60Hz Instantaneous DC 50/60Hz Ultra Short DC 50/60Hz Short DC 50/60Hz Medium DC 50/60Hz Long 50/60Hz Short, Hi-Inrush 50/60Hz Medium, Hi-Inrush 50/60Hz Long, Hi-Inrush DC Short, Hi-Inrush DC Medium, Hi-Inrush DC Long, Hi-Inrush Notes: 1 Actuator Code: A: Handle tie pin spacer(s) and retainers provided assembled with multi-pole units. B: Handle location as viewed from front of breaker: 2 pole - left pole 3 pole - center pole 4 pole - two handles at center poles 5 pole - three handles at center poles 6 pole - four handles at center poles S: Handle moves to mid-position only upon electrical trip of the breaker. Available with circuit codes B, C, D, E, F, G, H and K. T: Handle moves to mid-position and alarm switch activates only upon electrical trip of the breaker. Available with circuit codes B & C. 2 Standard multipole units have all poles identical except when specifying auxiliary switch and/or mixed poles. 4 pole max with VDE. 5th pole available as Series Trip with Voltage Coil only. 3 Switch Only circuits, rated up to 50 amps and 6 poles, and only available with VDE Certification when tied to a protected pole (Circuit Code B, C, D or H.). For .02 to 30 amps, select Current Code 630. For 35 - 50 amps, select Current Code 650. For 55-70 amps, select Current Code 670. For 75-100 amps, select Current Code 810. 4 Circuit Codes D,E,F,G,H & K available with Terminal Codes 1,2,4 & 5 only. Circuit Codes D, F, H & K available up to 50 amps maximum Current Rating. 5 Consult factory for available Dual Coil options, as special catalog number is required. Dual Coil Voltage Coils with Shunt Trip Construction trip instantaneously on line voltage. Dual Coil Voltage Coils require 30VA minimum power to trip instantaneously and are rated for intermittent duty only. 6 Auxiliary Switch available with Series Trip and Switch Only circuits. On multi-pole breakers, one auxiliary switch is supplied, mounted in the extreme right pole. 7 Voltage coils not rated for continuous duty. Available only with delay codes 10 & 20. 8 Available with Circuit Codes B & D only, and up to 50 amps maximum. 9 Current Ratings 60 - 70 are available up to four poles maximum. Ratings 71 - 100 are available up to two poles maximum. 10 Terminal Code 1 available to 60 amps maximum. 11 Terminal Codes 2, 4, 5 and C available to 50 amps maximum. 12 Terminal Codes 3, 6 & 9 available to 100 amps maximum. 13 Terminal Code 7 available to 25 amps maximum. 14 Terminal Code A available to 100 amps maximum. 15 Terminal Codes 7, 9 & C are not VDE approved. 16 No marking available. Consult factory. VDE/TUV Approval requires dual (I-O, ON-OFF) or I-O markings on all handles. 17 Single pole only. 18 VDE/TUV: 30 amps max.; UL/CSA: 50 amps max.; Available in 2 - 4 poles only and limited to AC Delays. “General Purpose amps” not rated for “full load amps” or to be used in applications with a motor. A32 32 DC A48 48 DC A65 65 DC J06 6 AC 8 TERMINAL 15 1 10 Stud 10-32 2 11 Screw 10-32 3 12 Stud 1/4-20 4 11 Stud M5 x 0.8 5 11 Screw M5 x 0.8 J12 J18 J24 J48 6 12 7 13,15 9 15 A 14 C 11,15 12 AC 18 AC 24 AC 48 AC Stud M6 0.250 Double Click Connect 7/16” Clip Terminal Plug-In Stud 5/16” Clip Terminal 9 ACTUATOR COLOR & LEGEND 16 Actuator Color I-O ON-OFF Dual Legend Color White AB 1Black Black CD 2White Red FG 3White Green HJ 4White Blue KL 5White Yellow MN 6Black Gray PQ 7Black Orange RS 8Black Black (short handle)17 TU 9 White 10 MOUNTING / BARRIERS MOUNTING STYLE BARRIERS Threaded Insert 1 6-32 x 0.195 inches no A 6-32 X 0.195 inches yes 18 C 6-32 X 0.195 inches yes 2 ISO M3 x 5mm no B ISO M3 x 5mm yes D 18 ISO M3 x 5mm yes Front panel Snap-In, 1.00” [25.4mm] wide bezel 17 E with Handleguard no VOLTAGE < 300 < 300 ≥ 300 < 300 < 300 ≥ 300 < 300 11 AGENCY APPROVAL C UL Recognized, CSA Accepted D VDE Certified, UL Recognized, CSA Accepted E TUV Certified, UL Recognized, CSA Accepted H UL489 Construction: VDE Certified, UL Recognized, CSA Accepted I UL Recognized STD 1077, UL Recognized 1500 (ignition protected), CSA Accepted L UL489 Construction: UL Recognized, CSA Accepted R UL489 Construction: TUV Certified, UL Recognized, CSA Accepted Email: [email protected] Application Support: [email protected] Phone: (860) 793–9281 Fax: (860) 793–9231 www.carlingtech.com C-Series Circuit Breaker - Handle UL489A Listed / Parallel Pole – Ordering Scheme | 7 C A 2 1 Series 2 Actuator P 0 4 Circuit 3 Poles D4 5 Aux/Alarm Switch 6 Frequency & Delay 820 7 Current Rating 3 2 1 8 Terminal 9 Actuator Color 10 Mounting 8 TERMINAL 5 3 Stud 1/4-20 6 Stud M6 A Plug-In Stud 3 1 SERIES C 2 ACTUATOR A Handle, one per pole S Mid-Trip Handle, one per pole 1 T Mid-Trip, one per pole & Alarm Switch 1 3 POLES 4 1 One 2 Two 3 Three 4 CIRCUIT P Series Trip (parallel pole) 5 AUXILIARY / ALARM SWITCH 0 without Aux Switch 2 S.P.D.T., 0.110 Q.C. Term. 3 S.P.D.T., 0.139 Solder Lug 4 S.P.D.T., 0.110 Q.C. Term. (Gold Contacts) 5 S.P.S.T., N.O., 0.110 Q.C Term. (Gold Contacts) 6 7 8 9 S.P.S.T., 0.139 Solder Lug S.P.S.T., 0.110 Q.C Term. (Gold Contacts) S.P.S.T., 0.187 Q.C. Term. S.P.D.T., 0.187 Q.C. Term. 9 ACTUATOR COLOR 2 LEGEND ON-OFF White B Black D Red G Green J Blue L Yellow N Gray Q Orange S Dual Legend Color 1Black 2 White 3White 4White 5White 6Black 7Black 8Black 10 MOUNTING Threaded Insert 1 6-32 x 0.195 inches 2 ISO M3 x 5mm 11 MAXIMUM APPLICATION RATING M 80 DC 6 FREQUENCY & DELAY D1 DC Ultra Short D2 DC Short D4 DC Medium D6 DC Long 12 AGENCY APPROVAL A Without Approval K UL489A Listed, VDE Certified T UL489A Listed 7 UL489A Listed, TUV Certified 7 CURRENT RATING (AMPERES) 4 CODEAMPERES 810 811 812 912 100.00 110.00 120.00 125.00 M T 11 12 Max. App. Agency Rating Approval 813 814 815 816 130.00 140.00 150.00 160.00 817 917 818 819 170.00 175.00 180.00 190.00 820 922 825 200.00 225.00 250.00 Notes: 1 Handle moves to Mid-Position only upon electrical trip of C/B when Actuator S is specified. When Actuator Code T is specified, handle moves to Mid Position and Alarm Switch actuates only upon electrical trip of C/B. Code T is only available with Circuit Code N. 2 Standard Handle colors are White, Black, Red & Yellow. 3 Breakers with Terminal Codes 3 & 6 are supplied with bus bars connecting the Line and Load Terminals. For Terminal Code A, Line and Load Terminals must be connected to a copper bus bar having a minimum cross-section of 0.078 square inches. Terminal code A not available on the single pole unit. 4 Ratings for 101 to 125 amps are available in 1-pole size. Ratings from 110 to 200 amps are available in 2-pole size. For ratings from 225-250 amps, specify 3-pole size. For ratings from 350-400 amps, specify 4-pole size. 5 1 pole only available with terminal codes 3 and 6. Email: [email protected] Application Support: [email protected] Phone: (860) 793–9281 Fax: (860) 793–9231 www.carlingtech.com 8 | C-Series Circuit Breaker - Rocker UL489A Listed / Parallel Pole – Ordering Scheme C 1 2 1 Series 2 Actuator P 0 4 Circuit 3 Poles D4 5 Aux/Alarm Switch 6 Frequency & Delay 1 SERIES C 2 ACTUATOR C Curved Rocker, Two Color Visi, Indicate On, Vertical Legend D Curved Rocker, Two Color Visi, Indicate On, Horizontal Legend F Curved Rocker, Two Color Visi, Indicate Off, Vertical Legend G Curved Rocker, Two Color Visi, Indicate Off, Horizontal Legend J Curved Rocker, Single Color, Vertical Legend K Curved Rocker, Single Color, Horizontal Legend N Curved Rocker, Push To Reset, Two Color Visi, Vertical Legend O Curved Rocker, Push To Reset, Two Color Visi, Horizontal Legend 1 Flat Rocker, Two Color Visi, Vertical Legend 2 Flat Rocker, Two Color Visi, Horizontal Legend 3 Flat Rocker, Single Color, Vertical Legend 4 Flat Rocker, Single Color, Horizontal Legend 5 Flat Rocker, Push To Reset, Two Color Visi, Vertical Legend 6 Flat Rocker, Push To Reset, Two Color Visi, Horizontal Legend 7 Flat Rocker, Push To Reset, Single Color, Vertical Legend 8 Flat Rocker, Push To Reset, Single Color, Horizontal Legend 3 POLES 2 1 One 2 Two 3 Three 4 CIRCUIT P Series Trip (parallel pole) 5 AUXILIARY/ALARM SWITCH 0 without Aux Switch 2 S.P.D.T., 0.110 Q.C. Term. 3 S.P.D.T., 0.139 Solder Lug 4 S.P.D.T., 0.110 Q.C. Term. (Gold Contacts) 5 S.P.S.T., N.O., 0.110 Q.C Term. (Gold Contacts) 6 7 8 9 S.P.S.T., 0.139 Solder Lug S.P.S.T., 0.110 Q.C Term. (Gold Contacts) S.P.S.T., 0.187 Q.C. Term. S.P.D.T., 0.187 Q.C. Term. 820 7 Current Rating 3 2 A 8 Terminal 9 Actuator Color 10 Mounting 7 CURRENT RATING (AMPERES) 2 8 TERMINAL 3 3 Stud 1/4-20 6 Stud M6 A Plug-In Stud 1 9 ACTUATOR COLOR LEGEND ON-OFF White B Black D Red G Green J Blue L Yellow N Gray Q Orange S Dual Legend Color 1 Black 2 White 3 White 4 White 5 White 6 Black 7 Black 8 Black 10 MOUNTING ROCKER / MOUNTING INSERT STYLE A Standard Rocker Bezel - 6-32 Inserts B Standard Rocker Bezel - M3 Inserts C Rocker Guard Bezel - 6-32 Inserts D Rocker Guard Bezel - M3 Inserts E Standard Bezel with recessed Off Side Flat Rocker - 6-32 Inserts F Standard Bezel with recessed Off Side Flat Rocker - M3 Inserts G Push to Reset Bezel - 6-32 Inserts H Push to Reset Bezel - M3 Inserts 11 MAXIMUM APPLICATION RATING M 80 DC 12 AGENCY APPROVAL A Without Approval T UL489A Listed 7 UL489A Listed, TUV Certified CODEAMPERES 100.00 110.00 120.00 125.00 813 814 815 816 130.00 140.00 150.00 160.00 11 12 Max. App. Agency Rating Approval Notes: 1 Breakers with Terminal Codes 3 & 6 are supplied with bus bars connecting the Line and Load Terminals. For Terminal Code A, Line and Load Terminals must be connected to a copper bus bar having a minimum cross-section of 0.078 square inches. Terminal code A not available on the single pole unit. 2 Ratings for 101 to 125 amps are available in 1-pole size. Ratings from 110 to 200 amps are available in 2-pole size. For ratings from 225-250 amps, specify 3-pole size. For ratings from 350-400 amps, specify 4-pole size. 3 1 pole only available with terminal codes 3 and 6. 6 FREQUENCY & DELAY D1 DC Ultra Short D2 DC Short D4 DC Medium D6 DC Long 810 811 812 912 M T 817 917 818 819 170.00 175.00 180.00 190.00 820 922 825 200.00 225.00 250.00 Email: [email protected] Application Support: [email protected] Phone: (860) 793–9281 Fax: (860) 793–9231 www.carlingtech.com C-Series Circuit Breaker - Handle UL489 Listed – Ordering Scheme | 9 C A 3 1 Series 2 Actuator B 0 4 Circuit 3 Poles 14 5 Aux/Alarm Switch 6 Frequency & Delay 1 SERIES C 450 7 Current Rating 1 2 1 8 Terminal 9 Actuator Color 10 Mounting/ Barriers K G 11 Max. App. Rating 12 Agency Approval 7 CURRENT RATING (AMPERES) CODEAMPERES 2 ACTUATOR 1 A Handle, one per pole B Handle, one per multipole unit S Mid-Trip Handle, one per pole T Mid-Trip Handle, one per pole & Alarm Switch 3 POLES 2 1 One 2 Two 3 Three 4 CIRCUIT B Series Trip (Current) 5 AUXILIARY / ALARM SWITCH 3 0 without Aux Switch 2 S.P.D.T., 0.110 Q.C. Term. 3 S.P.D.T., 0.139 Solder Lug 4 S.P.D.T., 0.110 Q.C. Term. (Gold Contacts) 6 FREQUENCY & DELAY 11 DC Ultra Short 12 DC Short 14 DC Medium 16 DC Long 21 50/60Hz Ultra Short 22 50/60Hz Short 24 50/60Hz Medium 6 8 9 S.P.S.T., 0.139 Solder Lug S.P.S.T., 0.187 Q.C. Term. S.P.D.T., 0.187 Q.C. Term. 26 42 4 44 4 46 4 52 4 54 4 56 4 50/60Hz Long 50/60Hz Short, Hi-Inrush 50/60Hz Medium, Hi-Inrush 50/60Hz Long, Hi-Inrush DC Short, Hi-Inrush DC Medium, Hi-Inrush DC Long, Hi-Inrush Notes: 1 Actuator Code: A: Handle tie pin spacer(s) and retainers provided assembled with multi-pole units. B: Handle located, as viewed from front of breaker in left pole. 2 pole maximum. S: Handle moves to mid-position only upon electrical trip of the breaker. T: Handle moves to mid-position and alarm switch activates only upon electrical trip of the breaker. 2 Standard multipole units have all poles identical except when specifying auxiliary switch and/or mixed poles. 2 & 3 pole circuit breakers required for 120/240 VAC (Maximum application rating code C) applications, have all poles identical except when specifying auxiliary / alarm switch which is normally supplied in extreme right pole per figure B. Terminal barriers are required on all multipole breakers. Third pole is for 120/240 VAC applications requiring neutral disconnect. The 3rd pole has the same construction as poles 1 & 2. 3 On multi-pole breakers, one auxiliary. switch is supplied, mounted in the extreme right pole. VDE approval on auxiliary switch codes 2, 3 & 4 only. Auxiliary / Alarm Switch with Independent Circuit ie: separate from breaker circuit, only available with circuit breakers rated 50 amp maximum at 80 VDC, 125 VDC, and 120 VAC. Auxiliary / Alarm Switch with Dependent Circuit ie: same as circuit breaker, is supplied from factory with common terminal of auxiliary / alarm switch connected to line terminal on 120/240 and 240 VAC ratings. Circuit breakers rated 120 VAC 50 amp maximum can be supplied with Auxiliary/Alarm switch common terminal connected to breaker line terminal. Consult factory for special catalog number. 4 Available up to 50 amps maximum. 5 Current ratings 71 - 100 with VDE approvals are available up to two poles maximum. 6 Terminal Codes 9 & C are not VDE approved. 7 Terminal Code 1 available to 60 amps maximum. 8 Terminal Codes 2, 4, 5 & C available to 50 amps maximum. 9 Terminal Codes 3, 6 & 9 available to 100 amps maximum. 10 Terminal Code A available to 100 amps maximum. 11 VDE and TUV approvals require Dual (I-O, ON-OFF) markings on all handles. 12 Barriers supplied on multi-pole units only. 2100.100 2150.150 2200.200 2250.250 2300.300 2350.350 2400.400 2450.450 2500.500 2550.550 2600.600 2650.650 2700.700 2750.750 2800.800 2850.850 2900.900 2950.950 4101.000 5121.250 4151.500 517 1.750 4202.000 5222.250 4252.500 5272.750 4303.000 4353.500 4404.000 4454.500 4505.000 4555.500 4606.000 4656.500 8 TERMINAL 6 1 7 Stud 10-32 2 8 Screw 10-32 3 9 Stud 1/4-20 4 8 Stud M5 x 0.8 5 8 Screw M5 x 0.8 4707.000 4757.500 4808.000 4858.500 4909.000 4959.500 610 10.000 71010.500 611 11.000 71111.500 61212.000 71212.500 61313.000 61414.000 61515.000 61616.000 61717.000 6 9 9 9 A 10 C 8 61818.000 62020.000 62222.000 62424.000 62525.000 63030.000 635 35.000 640 40.000 66060.000 67070.000 68080.000 68585.000 69090.000 69595.000 810100.00 Stud M6 7/16” Clip Terminal Plug-In Stud 5/16” Clip Terminal 9 ACTUATOR COLOR & LEGEND 11 Actuator Color ON-OFF Dual Legend Color White B1Black Black D2White Red G3White Green J4White Blue L5White Yellow N6Black Gray Q7Black Orange S8Black 10 MOUNTING / BARRIERS MOUNTING STYLE Threaded Insert 1 6-32 x 0.195 inches 2 ISO M3 x 5mm BARRIERS 12 yes yes 11 MAXIMUM APPLICATION RATING A 65 DC B 125 DC C 120/240 AC 2 D 240 AC K 120 AC F 277 AC M 80 DC 12 AGENCY APPROVAL 11 A without approvals F UL489 Listed, CSA Certified & VDE Certified G UL489 Listed & CSA Certified J UL489 Listed, CSA Certified & TUV Certified Email: [email protected] Application Support: [email protected] Phone: (860) 793–9281 Fax: (860) 793–9231 www.carlingtech.com 10 | C-Series Circuit Breaker - Sealed Toggle UL Recognized – Ordering Scheme C M 3 1 Series 2 Actuator B 0 4 Circuit 3 Poles 5 Aux/Alarm Switch 10 6 Frequency & Delay 1 0 1 8 Terminal 9 Legend Plate C 10 Mounting Bezel/Barrier 11 Agency Approval 7 CURRENT RATING (AMPERES) 9 1 SERIES C CODEAMPERES 2 ACTUATOR 1 M 450 7 Current Rating Sealed Toggle, one per pole 3 POLES 1 One 2 Two 3 Three 4 CIRCUIT A 2 Switch Only (no coil) B Series Trip (current) C Series Trip (voltage) D 3 Shunt Trip (current) E 3 Shunt Trip (voltage) F 3 G 3 H 3,4 K 3,4 Relay Trip (current) Relay Trip (voltage) Dual Coil with Shunt Trip Voltage Coil Dual Coil with Relay Trip Voltage Coil 5 AUXILIARY / ALARM SWITCH 0 without Aux Switch 2 S.P.D.T., 0.110 Q.C. Term. 3 S.P.D.T., 0.139 Solder Lug 4 S.P.D.T., 0.110 Q.C. Term. (Gold Contacts) 6 8 9 S.P.S.T., 0.139 Solder Lug S.P.S.T., 0.187 Q.C. Term. S.P.D.T., 0.187 Q.C. Term. 6 FREQUENCY & DELAY 03 2 DC 50/60Hz, Switch Only 10 6 DC Instantaneous 11 DC Ultra Short 12 DC Short 14 DC Medium 16 DC Long 20 6 50/60Hz Instantaneous 21 50/60Hz Ultra Short 22 50/60Hz Short 24 50/60Hz Medium 26 50/60Hz Long 30 31 32 34 36 42 7 44 7 46 7 52 7 54 7 56 DC 50/60Hz Instantaneous DC 50/60Hz Ultra Short DC 50/60Hz Short DC 50/60Hz Medium DC 50/60Hz Long 50/60Hz Short, Hi-Inrush 50/60Hz Medium, Hi-Inrush 50/60Hz Long, Hi-Inrush DC Short, Hi-Inrush DC Medium, Hi-Inrush DC Long, Hi-Inrush Notes: 1 Actuator Code M: Handle location as viewed from front of breaker: 2 pole - right pole 3 pole - center pole 2 Switch Only circuits, rated up to 50 amps and 3 poles, and only available with VDE. For .02 to 30 amps, select Current Code 630. For 35 - 50 amps, select Current Code 650. For 55-70 amps, select Current Code 670. For 75-100 amps, select Current Code 810. 3 Circuit Codes D,E,F,G,H & K available with Terminal Codes 1,2,4 & 5 only. 4 Consult factory for available Dual Coil options, as special catalog number is required. Dual Coil Voltage Coils with Shunt Trip Construction trip instantaneously on line voltage. Dual Coil Voltage Coils require 30VA minimum power to trip instantaneously and are rated for intermittent duty only. 5 Auxiliary Switch available with Series Trip and Switch Only circuits. On multi-pole breakers, one auxiliary switch is supplied, mounted in the extreme right pole. 6 Voltage coils not rated for continuous duty. Available only with delay codes 10 & 20. 7 Available with Circuit Codes B & D only, and up to 50 amps maximum. 8 Consult factory for current ratings 71-100, in three pole units, available as special catalog number only. 9 Terminal Code 1 available to 60 amps maximum. 10 Terminal Codes 2, 4, 5 and C available to 50 amps maximum. 11 Terminal Codes 3, 6 & 9 available to 100 amps maximum. 12 Terminal Code 7 available to 25 amps maximum. 13 Terminal Code A available to 100 amps maximum. 0200.020 2350.350 4303.000 0250.025 2400.400 4353.500 0300.030 2450.450 4404.000 0350.035 2500.500 4454.500 0400.040 2550.550 4505.000 0450.045 2600.600 4555.500 0500.050 2650.650 4606.000 0550.055 2700.700 4656.500 0600.060 2750.750 4707.000 0650.065 2800.800 4757.500 0700.070 2850.850 4808.000 0750.075 2900.900 4858.500 0800.080 2950.950 4909.000 0850.085 4101.000 4959.500 0900.090 5121.250 610 10.000 0950.095 4151.500 71010.500 2100.100 517 1.750 611 11.000 2150.150 4202.000 71111.500 2200.200 5222.250 61212.000 2250.250 4252.500 71212.500 2300.300 5272.750 61313.000 OR VOLTAGE COIL (NORMAL RATED VOLTAGE) 7 61414.000 61515.000 61616.000 61717.000 61818.000 62020.000 62222.000 62424.000 62525.000 63030.000 635 35.000 640 40.000 65050.000 660 960.000 670 970.000 680 980.000 685 985.000 690 990.000 695 995.000 810 9100.00 A06 6 DC A12 12 DC A18 18 DC A24 24 DC J65 65 AC K20 120 AC L40 240 AC CODEAMPERES A32 32 DC A48 48 DC A65 65 DC J06 6 AC 8 TERMINAL 1 9 Stud 10-32 2 10 Screw 10-32 11 3 Stud 1/4-20 4 10 Stud M5 x 0.8 5 10 Screw M5 x 0.8 J12 J18 J24 J48 6 11 7 12 9 11 A 13 C 10 12 AC 18 AC 24 AC 48 AC Stud M6 0.250 Double Click Connect 7/16” Clip Terminal Plug-In Stud 5/16” Clip Terminal 9 LEGEND PLATE 0 No Legend 10 MOUNTING / BARRIERS MOUNTING STYLE 1 Standard Hex Nut A Standard Hex Nut (multi-pole units only) BARRIERS no yes 11 AGENCY APPROVAL C UL Recognized & CSA Accepted I UL Recognized & CSA Accepted, UL1500 ignition protection L UL Recognized & CSA Accepted with listed construction Email: [email protected] Application Support: [email protected] Phone: (860) 793–9281 Fax: (860) 793–9231 www.carlingtech.com C-Series Circuit Breaker - Rocker UL Recognized – Ordering Scheme | 11 C C 3 1 Series 2 Actuator 14 B 0 4 Circuit 3 Poles 5 Aux/Alarm Switch 450 6 Frequency & Delay 1 SERIES C 9 Actuator Color 10 Mounting/ Barriers D 11 Agency Approval CODEAMPERES 2 Two 3 4 CIRCUIT F 4 A 3 Switch Only (No Coil) G 4 B Series Trip (Current) H 4,5 C Series Trip (Voltage) 4 D Shunt Trip (Current) K 4,5 E 4 Shunt Trip (Voltage) 5 AUXILIARY / ALARM SWITCH 6 0 without Aux Switch 2 S.P.D.T., 0.110 Q.C. Term. 3 S.P.D.T., 0.139 Solder Lug 4 S.P.D.T., 0.110 Q.C. Term. (Gold Contacts) 6 FREQUENCY & DELAY 03 DC 50/60Hz, Switch Only 10 7 DC Instantaneous 11 DC Ultra Short 12 DC Short 14 DC Medium 16 DC Long 20 7 50/60Hz Instantaneous 21 50/60Hz Ultra Short 22 50/60Hz Short 24 50/60Hz Medium 26 50/60Hz Long 0200.020 2350.350 4303.000 0250.025 2400.400 4353.500 0300.030 2450.450 4404.000 0350.035 2500.500 4454.500 0400.040 2550.550 4505.000 0450.045 2600.600 4555.500 0500.050 2650.650 4606.000 0550.055 2700.700 4656.500 0600.060 2750.750 4707.000 0650.065 2800.800 4757.500 0700.070 2850.850 4808.000 0750.075 2900.900 4858.500 0800.080 2950.950 4909.000 0850.085 4101.000 4959.500 0900.090 5121.250 610 10.000 0950.095 4151.500 71010.500 2100.100 517 1.750 611 11.000 2150.150 4202.000 71111.500 2200.200 5222.250 61212.000 2250.250 4252.500 71212.500 2300.300 5272.750 61313.000 OR VOLTAGE COIL (NORMAL RATED VOLTAGE) 7 61414.000 61515.000 61616.000 61717.000 61818.000 62020.000 62222.000 62424.000 62525.000 63030.000 635 35.000 640 40.000 65050.000 660 960.000 670 970.000 680 980.000 685 985.000 690 990.000 695 995.000 810 9100.00 A06 6 DC A12 12 DC A18 18 DC A24 24 DC J65 65 AC K20 120 AC L40 240 AC CODEAMPERES 3 POLES 2 One 8 Terminal 7 CURRENT RATING (AMPERES) 2 ACTUATOR 1 Two Color Visi-Rocker C Indicate ON, vertical legend D Indicate ON, horizontal legend E Indicate ON, no legend F Indicate OFF, vertical legend G Indicate OFF, horizontal legend H Indicate OFF, no legend Push-To-Reset, Visi-Rocker N Indicate OFF,vertical legend O Indicate OFF,horizontal legend P Indicate OFF,no legend Single color J Vertical legend K Horizontal legend L No legend Push-To-Reset, Single color R Vertical legend U Horizontal legend V No legend 1 1 2 1 7 Current Rating 6 8 9 Three Relay Trip (Current) Relay Trip (Voltage) Dual Coil with Shunt Trip Voltage Coil Dual Coil with Relay Trip Voltage Coil S.P.S.T., 0.139 Solder Lug S.P.S.T., 0.187 Q.C. Term. S.P.D.T., 0.187 Q.C. Term. 30 31 32 34 36 42 8 44 8 46 8 52 8 54 8 56 8 DC 50/60Hz Instantaneous DC 50/60Hz Ultra Short DC 50/60Hz Short DC 50/60Hz Medium DC 50/60Hz Long 50/60Hz Short, Hi-Inrush 50/60Hz Medium, Hi-Inrush 50/60Hz Long, Hi-Inrush DC Short, Hi-Inrush DC Medium, Hi-Inrush DC Long, Hi-Inrush Notes: 1 Push-To-Reset actuators have OFF portion of rocker shrouded. 2 Multi-pole breakers have all poles identical except when specifying Auxiliary switch and/or mixed poles, and have one rocker per breaker. Rocker location as viewed from front panel: 2 pole – left pole; 3 pole – center pole. 3 Switch Only circuits, rated up to 50 amps and 3 poles, and only available with VDE Certification when tied to a protected pole (Circuit Code B, C, D or H.), For .02 to 30 amps, select Current Code 630. For 35 - 50 amps, select Current Code 650. For 55-70 amps, select Current Code 670. For 75-100 amps, select Current Code 810. 4 Circuit Codes D,E,F,G,H & K available with Terminal Codes 1,2,4 & 5 only. Circuit Codes D,F,H & K available up to 50 amps maximum Current Rating. 5 Consult factory for available Dual Coil options, as special catalog number is required. Dual Coil Voltage Coils with Shunt Trip Construction trip instantaneously on line voltage. Dual Coil Voltage Coils require 30VA minimum power to trip instantaneously and are rated for intermittent duty only. 6 Auxiliary Switch available with Series Trip and Switch Only circuits. On multi-pole breakers, one auxiliary switch is supplied, mounted in the extreme right pole. Auxiliary switch codes 2, 3 & 4 are VDE approved. 7 Voltage coils not rated for continuous duty. Available only with delay codes 10 & 20. 8 Available with Circuit Codes B & D only, and up to 50 amps maximum. 9 Current Ratings 60-70 are available up to four poles maximum. Ratings 71-100 are available up to two poles maximum. 10 Terminal Code 1 available to 60 amps maximum. 11 Terminal Codes 2,4,5 & C available to 50 amps maximum. 12 Terminal Codes 3,6 & 9 available to 100 amps maximum. 13 Terminal Code 7 available to 25 amps maximum. 14 Terminal Code A available to 100 amps maximum. 15 Terminal Codes 7, 9 & C are not VDE approved. 16 Color shown is visi and legend with remainder of rocker black 17 Legend on Push-to-reset bezel/shroud is white when single color rocker is ordered. Dual = ON-OFF/I-O legend with actuator codes C - G, and J, K, N, O, R, & U. None = no legend with actuator codes H, L, P, V. Rockerguard available with actuator codes C - L. Push-to-reset available with actuator codes N, O, P, R, U, V. 18 VDE/TUV approval requires Dual (I-O, ON-OFF) or I-O markings on rocker. 19 VDE/TUV: 30 amps max.; UL/CSA: 50 amps max.; Available in 2 - 4 poles only and limited to AC Delays. “General Purpose amps” not rated for “full load amps” or to be used in applications with a motor. A32 32 DC A48 48 DC A65 65 DC J06 6 AC 8 TERMINAL 1 10 Stud 10-32 2 11 Screw 10-32 3 12 Stud 1/4-20 4 11 Stud M5 x 0.8 5 11 Screw M5 x 0.8 J12 J18 J24 J48 12 AC 18 AC 24 AC 48 AC 6 12 Stud M6 7 13 0.250 Double Quick Connect 9 7/16” Clip Terminal A 14 Plug-In Stud C 5/16” Clip Terminal 9 ACTUATOR COLOR & LEGEND 16,17,18 Actuator or Visi-Color Marking: Marking Color: Single Color Color: I-O ON-OFF Dual/None Rocker/Handle Visi-Rocker White A B 1 Black White Black C D 2 White n/a Red F G 3 White Red Green H J 4 White Green Blue K L 5 White Blue Yellow M N 6 Black Yellow Gray P Q 7 Black Gray Orange R S 8 Black Orange 10 MOUNTING / BARRIERS 1 STANDARD ROCKER BEZEL 1 6-32 x 0.195 inches 2 6-32 x 0.195 inches 3 19 6-32 x 0.195 inches 4 ISO M3 x 5mm 5 ISO M3 x 5mm 6 19 ISO M3 x 5mm ROCKERGUARD BEZEL A 6-32 x 0.195 inches C 6-32 x 0.195 inches E 19 6-32 x 0.195 inches G ISO M3 x 5mm J ISO M3 x 5mm L 19 ISO M3 x 5mm PUSH-TO-RESET BEZEL B 6-32 x 0.195 inches D 6-32 x 0.195 inches 19 F 6-32 x 0.195 inches H ISO M3 x 5mm J ISO M3 x 5mm 19 M ISO M3 x 5mm BARRIERSVOLTAGE no <300 yes <300 yes ≥300 no <300 yes <300 yes ≥300 no yes yes no yes yes <300 <300 ≥300 <300 <300 ≥300 no yes yes no yes yes <300 <300 ≥300 <300 <300 ≥300 11 AGENCY APPROVAL C UL Recognized & CSA Accepted D VDE Certified, UL Recognized & CSA Accepted E TUV Certified, UL Recognized & CSA Accepted H UL489 Construction: VDE Certified, UL Recognized & CSA Accepted I UL Recognized STD 1077, UL Recognized 1500 (ignition protected), & CSA Accepted L UL489 Construction: UL Recognized & CSA Accepted R UL489 Construction: TUV Certified, UL Recognized & CSA Accepted Email: [email protected] Application Support: [email protected] Phone: (860) 793–9281 Fax: (860) 793–9231 www.carlingtech.com 12 | C-Series Circuit Breaker - Rocker UL Listed – Ordering Scheme C C 3 1 Series 2 Actuator B 0 4 Circuit 3 Poles 14 5 Aux/Alarm Switch 6 Frequency & Delay 450 7 Current Rating Two Color Visi-Rocker C Indicate ON, vertical legend D Indicate ON, horizontal legend F Indicate OFF, vertical legend G Indicate OFF, horizontal legend 2100.100 2150.150 2200.200 2250.250 2300.300 2350.350 2400.400 2450.450 2500.500 2550.550 2600.600 2650.650 2700.700 2750.750 2800.800 2850.850 2900.900 Single color J Vertical legend K Horizontal legend ROCKER STYLE DESCRIPTIONS INDICATE "ON" VERTICAL STYLE K G 10 Mounting/ Barriers 11 Max. App. Rating 12 Agency Approval CODEAMPERES 2 ACTUATOR 1 INDICATE "OFF" SINGLE COLOR CODE "F" CODE "J" CODE "C" INDICATE COLOR LOCATION HORIZONTAL STYLE 9 Actuator Color 7 CURRENT RATING (AMPERES) 4 1 SERIES C LINE 1 2 A 8 Terminal LINE CODE "G" CODE "K" LINE 3 POLES 1 1 One 2 8 TERMINAL 1 5 Stud 10-32 2 6 Screw 10-32 with saddle & washer clamps 3 7 Stud 1/4-20 4 6 Stud M5 x 0.8 5 6 Screw M5 x 0.8 with saddle & washer clamps LINE Two 3 61818.000 62020.000 62222.000 62424.000 62525.000 63030.000 635 35.000 640 40.000 65050.000 660 60.000 670 70.000 680 80.000 685 85.000 690 90.000 695 95.000 810 100.00 5 AUXILIARY / ALARM SWITCH 2 0 without Aux Switch 2 S.P.D.T., 0.110 Q.C. Term. 3 S.P.D.T., 0.139 Solder Lug 4 S.P.D.T., 0.110 Q.C. Term. (Gold Contacts) 6 8 9 S.P.S.T., 0.139 Solder Lug S.P.S.T., 0.187 Q.C. Term. S.P.D.T., 0.187 Q.C. Term. 42 8 44 8 46 8 52 8 54 8 56 6 7 9 7,8 A 7,8 C 6,8 Stud M6 7/16” Clip Terminal Plug-In Stud 5/16” Clip Terminal Three 4 CIRCUIT B Series Trip (current) 6 FREQUENCY & DELAY 11 DC Ultra Short 12 DC Short 14 DC Medium 16 DC Long 21 50/60Hz Ultra Short 22 50/60Hz Short 24 50/60Hz Medium 26 50/60Hz Long 4707.000 4757.500 4808.000 4858.500 4909.000 4959.500 610 10.000 71010.500 611 11.000 71111.500 61212.000 71212.500 61313.000 61414.000 61515.000 61616.000 61717.000 LINE CODE "D" LINE 2950.950 4101.000 5121.250 4151.500 517 1.750 4202.000 5222.250 4252.500 5272.750 4303.000 4353.500 4404.000 4454.500 4505.000 4555.500 4606.000 4656.500 50/60Hz Short, Hi-Inrush 50/60Hz Medium, Hi-Inrush 50/60Hz Long, Hi-Inrush DC Short, Hi-Inrush DC Medium, Hi-Inrush DC Long, Hi-Inrush Notes: 1 Multi-pole breakers have all breakers identical except when specifying Auxiliary switch and/or mixed poles, and have one rocker per breaker. 2 On multi-pole breakers, one auxiliary switch is supplied, mounted in the extreme right pole. 3 Available up to 50 amps maximum. 4 Current ratings 71 - 100 with VDE approvals are available up to two poles maximum. 5 Terminal Code 1 available to 60 amps maximum. 6 Terminal Codes 2, 4, 5 & C available to 50 amps maximum. 7 Terminal Codes 3, 6, 9 & A available to 100 amps maximum. 8 Terminal Codes 9 & C are not VDE approved. 9 Color shown is visi and legend with remainder of rocker black 10 Dual = ON-OFF/I-O legend on actuator. 11 VDE and TUV approval requires Dual (I-O, ON-OFF) markings on rocker. 12 Rockerguard available with all actuator codes. 13 Barriers supplied on multi-pole units only. 14 2 & 3 pole circuit breakers required for 120/240 AC rating. 9 ACTUATOR COLOR & LEGEND 11 Actuator or Visi-Color Marking: Marking Color: Single Color 10 Color: ON-OFF Dual Rocker/Handle White B 1 Black Black D 2 White Red G 3 White Green J 4 White Blue L 5 White Yellow N 6 Black Gray Q7 Black Orange S 8 Black 10 MOUNTING / BARRIERS 12 Standard Rocker Bezel Threaded Insert, 2 per pole A 6-32 X 0.195 inches C ISO M3 x 5mm Rockerguard Bezel Threaded Insert, 2 per pole B 6-32 x 0.195 inches D ISO M3 x 5mm BARRIERS 13 yes yes yes yes 11 MAXIMUM APPLICATION RATING A 65 DC B 125 DC C 120/240 AC 14 D 240 AC F 277 AC K 120 AC M 80 DC 12 AGENCY APPROVAL A without approvals F UL 489 Listed, CSA Certified, & VDE Certified G UL 489 Listed & CSA Certified J UL489 Listed, CSA Certified & TUV Certified Email: [email protected] Application Support: [email protected] Phone: (860) 793–9281 Fax: (860) 793–9231 www.carlingtech.com Visi-Rocker White n/a Red Green Blue Yellow Gray Orange C-Series Circuit Breaker - Flat Rocker UL Recognized – Ordering Scheme | 13 C 1 2 1 Series 2 Actuator B 0 4 Circuit 3 Poles 5 Aux/Alarm Switch 10 450 6 Frequency & Delay 7 Current Rating 9 Actuator Color 10 Mounting/ Barriers E 11 Agency Approval 7 CURRENT RATING (AMPERES) 9 1 SERIES C CODEAMPERES 2 ACTUATOR 1 Two Color Visi-Rocker 1 Indicate OFF, vertical legend 2 Indicate OFF, horizontal legend Single color 3 Vertical legend 4 Horizontal legend Push-To-Reset, Visi-Rocker 5 Indicate OFF, vertical legend 6 Indicate OFF, horizontal legend Push-To-Reset , Single color 7 Vertical legend 8 Horizontal legend 3 POLES 2 1 One 1 2 1 8 Terminal 2 Two 3 4 CIRCUIT F 4 A 3 Switch Only (No Coil) G 4 B Series Trip (Current) H 4,5 C Series Trip (Voltage) D 4 Shunt Trip (Current) K 4,5 E 4 Shunt Trip (Voltage) 5 AUXILIARY / ALARM SWITCH 6 0 without Aux Switch 2 S.P.D.T., 0.110 Q.C. Term. 3 S.P.D.T., 0.139 Solder Lug 4 S.P.D.T., 0.110 Q.C. Term. (Gold Contacts) 6 FREQUENCY & DELAY 03 DC 50/60Hz, Switch Only 10 7 DC Instantaneous 11 DC Ultra Short 12 DC Short 14 DC Medium 16 DC Long 20 7 50/60Hz Instantaneous 21 50/60Hz Ultra Short 22 50/60Hz Short 24 50/60Hz Medium 26 50/60Hz Long 6 8 9 Relay Trip (Current) Relay Trip (Voltage) Dual Coil with Shunt Trip Voltage Coil Dual Coil with Relay Trip Voltage Coil 30 31 32 34 36 42 8 44 8 46 8 52 8 54 8 56 8 DC 50/60Hz Instantaneous DC 50/60Hz Ultra Short DC 50/60Hz Short DC 50/60Hz Medium DC 50/60Hz Long 50/60Hz Short, Hi-Inrush 50/60Hz Medium, Hi-Inrush 50/60Hz Long, Hi-Inrush DC Short, Hi-Inrush DC Medium, Hi-Inrush DC Long, Hi-Inrush Notes: 1 Push-to-reset actuators have OFF portion of rocker shrouded. 2 Multi-pole breakers have all poles identical except when specifying Auxiliary switch and/or mixed poles, and have one rocker per breaker. Rocker location as viewed from front panel: 2 pole – left pole; 3 pole – center pole. 3 Switch Only circuits, rated up to 50 amps and 3 poles, and only available with VDE Certification when tied to a protected pole (Circuit Code B, C, D or H.). For .02 to 30 amps, select Current Code 630. For 35 - 50 amps, select Current Code 650. For 55-70 amps, select Current Code 670. For 75-100 amps, select Current Code 810. 4 Circuit Codes D,E,F,G,H & K available with Terminal Codes 1,2,4 & 5 only. Circuit Codes D,F,H & K available up to 50 amps maximum Current Rating. 5 Consult factory for available Dual Coil options, as special catalog number is required. Dual Coil Voltage Coils with Shunt Trip Construction trip instantaneously on line voltage. Dual Coil Voltage Coils require 30VA minimum power to trip instantaneously and are rated for intermittent duty only. 6 Auxiliary Switch available with Series Trip and Switch Only circuits. On multi-pole breakers, one auxiliary switch is supplied, mounted in the extreme right pole. Auxilary switch codes 2, 3 & 4 are VDE approved. 7 Voltage coils not rated for continuous duty. Available only with delay codes 10 and 20. 8 Available with Circuit Codes B & D only, and up to 50 amps maximum. 9 Current ratings 60-70 are available up to four poles maximum. Current ratings 71 - 100 are available up to two poles maximum. 10 Terminal Code 1 available to 60 amps maximum. 11 Terminal Codes 2,4,5 & C available to 50 amps maximum. 12 Terminal Codes 3,6 & 9 available to 100 amps maximum. 13 Terminal Code 7 available to 25 amps maximum. 14 Terminal Code A available to 100 amps maximum. 15 Terminal Codes 7, 9 & C are not VDE approved. 16 Color shown is visi & legend with remainder of rocker black. Dual = ON-OFF/I-O legend. 17 Legend on Push-to-reset bezel/shroud is white with single color actuator codes 7 & 8. Legend on Push-to-reset bezel/shroud matches visi-color of rocker with actuator codes 5 & 6. 18 VDE/TUV approval requires Dual (I-O, ON-OFF) or I-O markings on rocker. 19 VDE/TUV: 30 amps max.; UL/CSA: 50 amps max.; Available in 2 & 3 poles only and limited to AC Delays. “General Purpose amps” not rated for “full load amps” or to be used in applications with a motor. 20 Recessed “OFF SIDE” available with actuator codes 1,2,3&4. Legends on rocker are available in ink stamping only. 61414.000 61515.000 61616.000 61717.000 61818.000 62020.000 62222.000 62424.000 62525.000 63030.000 635 35.000 640 40.000 65050.000 660 960.000 670 970.000 680 980.000 685 985.000 690 990.000 695 995.000 810 9100.00 A06 6 DC A12 12 DC A18 18 DC A24 24 DC J65 65 AC K20 120 AC L40 240 AC CODEAMPERES Three S.P.S.T., 0.139 Solder Lug S.P.S.T., 0.187 Q.C. Term. S.P.D.T., 0.187 Q.C. Term. 0200.020 2350.350 4303.000 0250.025 2400.400 4353.500 0300.030 2450.450 4404.000 0350.035 2500.500 4454.500 0400.040 2550.550 4505.000 0450.045 2600.600 4555.500 0500.050 2650.650 4606.000 0550.055 2700.700 4656.500 0600.060 2750.750 4707.000 0650.065 2800.800 4757.500 0700.070 2850.850 4808.000 0750.075 2900.900 4858.500 0800.080 2950.950 4909.000 0850.085 4101.000 4959.500 0900.090 5121.250 610 10.000 0950.095 4151.500 71010.500 2100.100 517 1.750 611 11.000 2150.150 4202.000 71111.500 2200.200 5222.250 61212.000 2250.250 4252.500 71212.500 2300.300 5272.750 61313.000 OR VOLTAGE COIL (NORMAL RATED VOLTAGE) 7 A32 32 DC A48 48 DC A65 65 DC J06 6 AC 8 TERMINAL 1 10 Stud 10-32 2 11 Screw 10-32 3 12 Stud 1/4-20 4 11 Stud M5 x 0.8 5 11 Screw M5 x 0.8 J12 J18 J24 J48 6 12 7 13 9 15 A 14 C 15 12 AC 18 AC 24 AC 48 AC Stud M6 0.250 Double Quick Connect 7/16” Clip Terminal Plug-In Stud 5/16” Clip Terminal 9 ACTUATOR COLOR & LEGEND 16,17,18 Actuator or Visi-Color Marking: Marking Color: Single Color Color: I-O ON-OFF Dual/None Rocker/Handle Visi-Rocker White A B 1 Black White Black C D 2 White n/a Red F G 3 White Red Green H J 4 White Green Blue K L 5 White Blue Yellow M N 6 Black Yellow Gray P Q 7 Black Gray Orange R S 8 Black Orange 10 MOUNTING / BARRIERS 1 STANDARD ROCKER BEZEL 1 6-32 x 0.195 inches 2 6-32 x 0.195 inches 19 3 6-32 x 0.195 inches 4 ISO M3 x 5mm 5 ISO M3 x 5mm 19 6 ISO M3 x 5mm RECESSED OFF ROCKER 7 6-32 x 0.195 inches 8 6-32 x 0.195 inches 9 6-32 x 0.195 inches A ISO M3 x 5mm C ISO M3 x 5mm E ISO M3 x 5mm PUSH-TO-RESET BEZEL B 6-32 x 0.195 inches D 6-32 x 0.195 inches F 19 6-32 x 0.195 inches H ISO M3 x 5mm J ISO M3 x 5mm M 19 ISO M3 x 5mm BARRIERSVOLTAGE no <300 yes <300 yes ≥300 no <300 yes <300 yes ≥300 no yes yes no yes yes <300 <300 ≥300 <300 <300 ≥300 no yes yes no yes yes <300 <300 ≥300 <300 <300 ≥300 11 AGENCY APPROVAL C UL Recognized & CSA Accepted E TUV Certified, UL Recognized & CSA Accepted I UL Recognized STD 1077, UL Recognized 1500 (ignition protected), & CSA Accepted L UL489 Construction: UL Recognized & CSA Accepted R UL489 Construction: TUV Certified, UL Recognized & CSA Accepted Email: [email protected] Application Support: [email protected] Phone: (860) 793–9281 Fax: (860) 793–9231 www.carlingtech.com 14 | C-Series Circuit Breaker - Flat Rocker UL Listed – Ordering Scheme C 1 2 1 Series 2 Actuator B 0 4 Circuit 3 Poles 14 5 Aux/Alarm Switch 6 Frequency & Delay 450 7 Current Rating 1 2 A 8 Terminal 9 Actuator Color K G 10 Mounting/ Barriers 11 Max. App. Rating 12 Agency Approval 7 CURRENT RATING (AMPERES) 5 1 SERIES C CODEAMPERES 2 ACTUATOR 1 Two Color Visi-Rocker 1 Indicate OFF, vertical legend 2 Indicate OFF, horizontal legend Single color 3 Vertical legend 4 Horizontal legend 2100.100 2150.150 2200.200 2250.250 2300.300 2350.350 2400.400 2450.450 2500.500 2550.550 2600.600 2650.650 2700.700 2750.750 2800.800 2850.850 2900.900 Push-To-Reset, Visi-Rocker 5 Indicate OFF, vertical legend 6 Indicate OFF, horizontal legend Push-To-Reset , Single color 7 Vertical legend 8 Horizontal legend 2950.950 4101.000 5121.250 4151.500 517 1.750 4202.000 5222.250 4252.500 5272.750 4303.000 4353.500 4404.000 4454.500 4505.000 4555.500 4606.000 4656.500 4707.000 4757.500 4808.000 4858.500 4909.000 4959.500 610 10.000 71010.500 611 11.000 71111.500 61212.000 71212.500 61313.000 61414.000 61515.000 61616.000 61717.000 8 TERMINAL 1 6 Stud 10-32 2 7 Screw 10-32 3 8 Stud 1/4-20 4 7 Stud M5 x 0.8 5 7 Screw M5 x 0.8 3 POLES 2 1 One 2 Two 3 Three 4 CIRCUIT B Series Trip (current) 5 AUXILIARY / ALARM SWITCH 3 0 without Aux Switch 2 S.P.D.T., 0.110 Q.C. Term. 3 S.P.D.T., 0.139 Solder Lug 4 S.P.D.T., 0.110 Q.C. Term. (Gold Contacts) 6 FREQUENCY & DELAY 11 DC Ultra Short 12 DC Short 14 DC Medium 16 DC Long 21 50/60Hz Ultra Short 22 50/60Hz Short 24 50/60Hz Medium 26 50/60Hz Long 6 8 9 S.P.S.T., 0.139 Solder Lug S.P.S.T., 0.187 Q.C. Term. S.P.D.T., 0.187 Q.C. Term. 42 4 50/60Hz Short, Hi-Inrush 44 4 50/60Hz Medium, Hi-Inrush 46 4 50/60Hz Long, Hi-Inrush 52 4 DC Short, Hi-Inrush 54 4 DC Medium, Hi-Inrush 56 4 DC Long, Hi-Inrush Notes: 1 Push-to-reset actuators have OFF portion of rocker shrouded. 2 Multi-pole breakers have all breakers identical except when specifying Auxiliary switch and/or mixed poles, and have one rocker per breaker. 3 On multi-pole breakers, one auxiliary switch is supplied, mounted in the extreme right pole. 4 Available up to 50 amps maximum. 5 Current ratings 71 - 100 with VDE approvals are available up to two poles maximum. 6 Terminal Code 1 available to 60 amps maximum. 7 Terminal Codes 2, 4, 5 & C available to 50 amps maximum. 8 Terminal Codes 3, 6, 9 & A available to 100 amps maximum. 9 Terminal Codes 9 & C are not VDE approved. 10 Color shown is visi and legend with remainder of rocker black 11 Dual = ON-OFF/I-O legend on actuator. 12 TUV approval requires Dual (I-O, ON-OFF) markings on rocker. 13 Legend on push-to-reset bezel/shroud is white when single color rocker is ordered. Legend on push-to-reset bezel/shroud matches visi-color of rocker with actuator codes 5 & 6. 14 Recessed “OFF-SIDE” available with actuator codes 1, 2, 3, & 4. Legends on rocker are available in ink stamping only. 15 Barriers supplied on multi-pole units only. 16 2 & 3 pole circuit breakers required for 120/240 AC rating. 6 8 9 8,9 A 8 C 7,9 Stud M6 7/16” Clip Terminal Plug-In Stud 5/16” Clip Terminal 9 ACTUATOR COLOR & LEGEND 10 Actuator or Visi-Color Marking: Marking Color: Single Color 11,12 Color: ON-OFF Dual Rocker/Handle White B 1 Black Black D 2 White Red G 3 White Green J 4 White Blue L 5 White Yellow N 6 Black Gray Q7 Black Orange S 8 Black 10 MOUNTING / BARRIERS STANDARD ROCKER BEZEL Threaded Insert, 2 per pole A 6-32 X 0.195 inches C ISO M3 x 5mm RECESSED OFF ROCKER 14 Threaded Insert, 2 per pole E 6-32 x 0.195 inches F ISO M3 x 5mm PUSH-TO-RESET BEZEL 13 Threaded Insert, 2 per pole B 6-32 x 0.195 inches D ISO M3 x 5mm BARRIERS 15 yes yes yes yes yes yes 11 MAXIMUM APPLICATION RATING A 65 DC B 125 DC C 120/240 AC 16 D 240 AC F 277 AC K 120 AC M 80 DC 12 AGENCY APPROVAL 12 A without approvals G UL 489 Listed & CSA Certified J UL489 Listed, CSA Certified & TUV Certified Email: [email protected] Application Support: [email protected] Phone: (860) 793–9281 Fax: (860) 793–9231 www.carlingtech.com 61818.000 62020.000 62222.000 62424.000 62525.000 63030.000 635 35.000 640 40.000 65050.000 660 60.000 670 70.000 680 80.000 685 85.000 690 90.000 695 95.000 810 100.00 Visi-Rocker White n/a Red Green Blue Yellow Gray Orange C-Series Circuit Breaker - Handle – Circuit & Terminal Diagrams | 15 Circuit & Terminal Diagrams: in. [mm] .960 [24.38] .311 DIA [Ø7.90] .558 [14.17] Notes: 1 All dimensions are in inches [millimeters]. 2 Tolerance ±.020 [.51] unless otherwise specified. 3 Available on Series Trip and Switch Only Circuits when called for on multi-pole units. Only one auxiliary switch is normally supplied, as viewed in mulit-pole identification scheme. Email: [email protected] Application Support: [email protected] Phone: (860) 793–9281 Fax: (860) 793–9231 www.carlingtech.com 16 | C-Series Circuit Breaker - Handle – Circuit & Terminal Diagrams Circuit & Terminal Diagrams: in. [mm] Notes: 1 All dimensions are in inches [millimeters]. 2 Tolerance ±.020 [.51] unless otherwise specified. 3 Schematic shown represents current trip circuits. 4 Available only as special catalog number. Email: [email protected] Application Support: [email protected] Phone: (860) 793–9281 Fax: (860) 793–9231 www.carlingtech.com C-Series Circuit Breaker - Handle – Dimensional Specifications | 17 Dimensional Specifications: in. [mm] Notes: 1 All dimensions are in inches [millimeters]. 2 Tolerance ±.020 [.51] unless otherwise specified. Email: [email protected] Application Support: [email protected] Phone: (860) 793–9281 Fax: (860) 793–9231 www.carlingtech.com 18 | C-Series Circuit Breaker - Handleguard – Dimensional Specifications Dimensional Specifications: in. [mm] Notes: 1 All dimensions are in inches [millimeters]. 2 Tolerance ±.020 [.51] unless otherwise specified. Email: [email protected] Application Support: [email protected] Phone: (860) 793–9281 Fax: (860) 793–9231 www.carlingtech.com C-Series Circuit Breaker - Arc Chute Barrier UL Recognized/Listed – Dimensional Specifications | 19 Dimensional Specifications: in. [mm] Notes: 1 Only 1-pole and 3-pole configurations shown. Arc chute (without barrier) and arc chute barrier also available for 2-pole construction. 2 Dimensions apply to all variations shown. 3 Notice that line and load terminal orientation for indicate on and indicate off rocker circuit breakers are opposite. 4 Screw type terminals shown for Rocker style (CF1, C11, etc) circuit breakers. For other terminal configurations see circuit and terminal diagrams. 5 All dimensions are in inches [millimeters]. 6 Tolerance ± .020 unless otherwise specified. 7 Must be ordered under a special catalog number. Email: [email protected] Application Support: [email protected] Phone: (860) 793–9281 Fax: (860) 793–9231 www.carlingtech.com 20 | C-Series Circuit Breaker - Parallel Pole – Dimensional Specifications Dimensional Specifications: in. [mm] Notes: 1 All dimensions are in inches [millimeters]. 2 Tolerance ±.020 [.51] unless otherwise specified. Email: [email protected] Application Support: [email protected] Phone: (860) 793–9281 Fax: (860) 793–9231 www.carlingtech.com C-Series Circuit Breaker - Sealed Toggle – Dimensional Specifications | 21 Dimensional Specifications: in. [mm] Notes: 1 All dimensions are in inches [millimeters]. 2 Tolerance ±.020 [.51] unless otherwise specified. Email: [email protected] Application Support: [email protected] Phone: (860) 793–9281 Fax: (860) 793–9231 www.carlingtech.com 22 | C-Series Circuit Breaker - Rocker – Circuit & Terminal Diagrams Circuit & Terminal Diagrams: in. [mm] Notes: 1 All dimensions are in inches [millimeters]. 2 Tolerance ±.020 [.51] unless otherwise specified. 3 Schematic shown represents current trip circuit. Email: [email protected] Application Support: [email protected] Phone: (860) 793–9281 Fax: (860) 793–9231 www.carlingtech.com C-Series Circuit Breaker - Rocker – Dimensional Specifications | 23 Dimensional Specifications: in. [mm] Notes: 1 Dimensions apply to all variations shown. Notice that circuit breaker line and load terminal orientation on indicate OFF is opposite of indicate ON. 2 For pole orientation with horizontal legend, rotate front view clockwise 90°. 3 All dimensions are in inches [millimeters]. 4 Tolerance ±.020 [.51] unless otherwise specified. Email: [email protected] Application Support: [email protected] Phone: (860) 793–9281 Fax: (860) 793–9231 www.carlingtech.com 24 | C-Series Circuit Breaker - Flat Rocker – Dimensional Specifications Dimensional Specifications: in. [mm] Notes: 1 For pole orientation with horizontal legend, rotate front view clockwise 90°. 2 All dimensions are in inches [millimeters]. 3 Tolerance ±.020 [.51] unless otherwise specified. Email: [email protected] Application Support: [email protected] Phone: (860) 793–9281 Fax: (860) 793–9231 www.carlingtech.com Reps & Contact | 25 Authorized Sales Representatives Click on the group name on the map below to find your local representative or visit www.carlingtech.com/findarep. « « Matera W. Canada Matera E. Canada MIDWEST DM Michigan TEMCO Northwest Alaska, Hawaii « NORTHERN Hanna Lind Ltd. Melody Emery Sierra Bridge Marketing Omega Limited Dy-tronix Inc. LD. Allen Norris DM Assoc East Pacent DM Assoc TSI North TSI WEST Signal Enterprises Luscombe Engineering Pinnacle Marketing Matrix DM Mexico South America Mexico « « Sunbelt Components SOUTHEAST ProRep Solutions LATIN AMERICA Americas Europe Middle East Africa Asia-Pacific Oceania About Carling Founded in 1920, Carling Technologies is a leading manufacturer of electrical and electronic switches and assemblies, circuit breakers, electronic controls, power distribution units, and multiplexed power distribution systems. With four ISO registered manufacturing facilities and technical sales offices worldwide, Carling Technologies Sales, Service and Engineering teams do much more than manufacture electrical components, they engineer powerful solutions! To learn more about Carling please visit www.carlingtech.com/company-profile. To view all of Carling’s environmental, quality, health & safety certifications please visit www.carlingtech.com/environmental-certifications Email: [email protected] Application Support: [email protected] Phone: (860) 793–9281 Fax: (860) 793–9231 www.carlingtech.com Worldwide Headquarters Carling Technologies, Inc. 60 Johnson Avenue, Plainville, CT 06062 Phone: 860.793.9281 Fax: 860.793.9231 Email: [email protected] Northern Region Sales Office: [email protected] Southeast Region Sales Office: [email protected] Midwest Region Sales Office: [email protected] West Region Sales Office: [email protected] Latin America Sales Office: [email protected] Asia-Pacific Headquarters Carling Technologies, Asia-Pacific Ltd., Kowloon, Hong Kong Phone: Int + 852-2737-2277 Fax: Int + 852-2736-9332 Email: [email protected] Shenzhen, China: [email protected] Shanghai, China: [email protected] Pune, India: [email protected] Kaohsiung, Taiwan: [email protected] Yokohama, Japan: [email protected] Europe | Middle East | Africa Headquarters Carling Technologies LTD 4 Airport Business Park, Exeter Airport, Clyst Honiton, Exeter, Devon, EX5 2UL, UK Phone: Int + 44 1392.364422 Fax: Int + 44 1392.364477 Email: [email protected] Germany: [email protected] France: [email protected] www.carlingtech.com REV_06_2016