M0116SD-161SDBR1-S

M0116SD161SDBR1S
VacuumFluorescentDisplayModule
RoHSCompliant
NewhavenDisplayInternational,Inc.
2511TechnologyDrive,Suite101
ElginIL,60124
Ph:8478448795
Fax:8478448796
www.newhavendisplay.com
[email protected]
[email protected]
1.SCOPE
This specification applies to VFD module M0116SD-161SDBR1-S.
2.FEATURES
2.1.Construction: Single board display module consists of 16 character (1*16) VFD,
VFD controller, DC/DC converter and all necessary control circuitry.
2.2. This module can be controlled by the host with three control signals, SEL, SLK,
SDATA.
2.3. Since a DC/DC converter is used. Power source (5Vdc) is required to operate
the module.
2.4. Characters are provided with a 5*7 dot matrix.
2.5. This module has 200 characters in Build-in character generator. The user definable
fonts(UDF) can be programable up to 8 characters.
3. PRODUCT SPECIFICATIONS
3.1.Outer Dimensions of PCB
Parameter
Width
Height
Thickness
Specification
100(mm)
28 (mm)
1.6 (mm)
3.2. Specifications of Display Panel
Parameter
Display Size (W*H)
Number of Digit
Character Size (W*H)
Color of illumination
Specification
61.8*5.1
16 Digits
2.55 * 5.1
Green
Unit
mm
mm
3.3. Environment Condition
Parameter
Operating Temperature
Storage Temperature
Humidity (Operating)
Humidity (Non-operating)
Vibration (10 ~ 55 Hz)
Shock
Min
-40
-50
20
0
-
Max
+85
+95
80
90
10
100
Unit
℃
℃
%
%
G
G
3.4. Absolute Maximum Ratings
Parameter
Supply Voltage
Input Signal Voltage
Symbol
VCC
VI
Min
0
0
Tye
5.0
-
Max
7.0
5.5
Unit
VDC
VDC
3.5. Recommend Operating Conditions(Ta=–10 ~ 70°C unless otherwise noted)
3.6. Pin assignment
Fig-3. Connector Description
3.6. VFD Grid Assignment And Dimension
Fig-4. VFD dimension and grid assignment
3.7. Outer Dimensions (Front panel, Structure outline)
Fig-5. Outer Dimensions (Structure outline)
4. FUNCTION DESCRIPTIONS
4.1. Command Description:
X : Don’t
care
* : Selection bits
“0” : Low – level
“1” : High – level
There is no 0xF6 function to set digit scan time,
If a command undefined sends to the module, there will nothing happens.
4.1.1. Set: display lengh:
4.1.2. Set digit dimmer value:
4.1.3. Set digit point:
4.1.4. Auto increment mode ON/OFF:
4.1.5. Display all ON/OFF:
4.1.6. Storing data in UDF:
The following 3steps define UDF to RA1~RA8
The 1st. is the declaration to degine UDF. (1 byte command)
The 2nd. Is the selection of a UDF character code number.(1 byte command)
And the 3rd. is the data set of the font.(5 byte command)
Therefore, to design user font to UDF, continuous cp,,amds of 7 bytes are need.
The UDF character code of RA1 TO RA8 are assigned to 00(Hex) to 07(Hex).
4.2. Scan Timing Description
4.2.1 Set display length
This command sets the display length.
For example,if 12digit selected,13~16digita are always OFF.
4.2.2. Display scan timing
T=4.096ms
Tdsp=256us
Tdig=240us
Tblk=16us
4.2.3.Character Display Operation
4.2.4.Character Display Operation
4.3.Initialization
The power on reset function allows the users to re-initialize the display controller, after
the power is turned off and then power on.
When the controller is initialized, the display status is given below
1. Address of each RAM :
Address “00”H
2. Data of each RAM
:
All contents are undefined
3. Display Digit
:
16 Digits
4. All Display Light
: OFF Mode
5. Segment Output
:
All Segment Outputs are set to “LOW”
6. Digit Dimmer Value :
8/16
4.4. Timing chart
4.4.1 Data write timing
The data shall be written fromD7(MSB) to D0(LSB). The data is fetched when the
Serial clock goes from Low to High.
4.4.2 Busy timing
This shows the internal operation time after receiving the serial data. Next data
is prohibited in this period. Next data is available after 6T of the operation clock
(about 500~4000ns)
4.4. Recommend Initial setting sequence
After reset, the module must be set according to the Initial Setting Flowchart shown
below.
4.5 Font Table