1. Open and Enclosed_Australia cata.qxd

OPEN FRAME & ENCLOSED
FLATPAC Series
5 0 - 6 0 0 W AT T S - A C / D C L O W P R O F I L E S I N G L E & M U LT I P L E O U T P U T
FEATURES
•
•
•
•
•
•
•
•
Inputs: 115/230VAC autoranging
VDE/FCC Class A, Class B
1,2 or 3 Output Models
Any output: 1 to 95VDC
UL, CSA, TÜV, VDE, BABT, CE, C-Tick
Remote sense and current limit
OVP and thermal shutdown
Any output 1 to 95V
SPECIFICATIONS
STANDARDS
INPUT
Voltage
110-240VAC Auto ranging
Isolation
Input to output: 4,242Vdc
Input to FG: 2,121Vdc
Output to FG: 707Vdc
Efficiency
Safety standards
Surge
Meets IEC801-5, Level 3
C-Tick
AS/NZS CISPR11 Group 1, Class A
EMC standards
Conducted emissions EN55022, FCC Class B,
radiated emissions Class A
EMC immunity
E
EMC immunity
IEC 61000-4,2,3,4,5,6,8 and 11
Dimensions (LxWxH)
78%-90%
OUTPUT
Product grade
C, I
Output voltage
See selection table
MECHANICAL
Low-High
50%–110%
70%–110%
Voltage trim program
Yes
Yes
Output power
See selection table
Current limit
Yes
Yes
Current limit setting
105%–125%
105%–135%
OVP set point
125%
125%
OVP and thermal
Yes
Yes
Temperature shutdown Yes
Yes
Set point accuracy
0.5%
1%
Dual output
Output ripple
1.5% p-p
3% p-p
Triple output
Load/line regulation
0.05% typ
0.5% typ
Holdup time
40mS
40mS
Remote sense
Yes
Yes
Compensation
0.5V
Baseplate operating
85°C
Temperature.
Shutdown temperature 95°C
0.5V
BUS OK status
Yes
Yes
UL 1604, UL60950-1, UL/CSA/EN/IEC 60950-1
85°C
95°C
AC OK status
Yes
Yes
Module disable
Yes
Yes
Single Output: VI-LU: 235x64x35mm.
Single Output: VI-MU: 235x125x35mm.
Single Output: VI-NU: 235x188x35mm.
Dual Output: VI-PU: 235x125x35mm.
Dual Output: VI-QU: 235x188x35mm.
Triple Output: VI-RU: 235x188x35mm.
SELECTION TABLE
Single output
VI-LU [ a ] – [ b ] [ c ] 50–200W
VI-MU [ a ] – [ b ] [ d ] 200–400W
VI-NU [ a ] – [ b ] [ e ] 300–600W
VI-PU [ a ] [ a ] – [ b ] [ c ] [ c ] 100–400W
VI-QU [ a ] [ a ] – [ b ] [ d ] [ c ] 150–600W
VI-RU [ a ] [ a ] [ a ] – [ b ] [ c ] [ c ] [ c ]
150–600W
Please substitute selection character, e.g. [ a ]
[ b ] [ c ], with value designator in the
appropriate table below.
# For conduction cooled models add – cc at
end of model number.
A=Output Voltage
Z=2V
0=5V
1=12V
3=24V
4=48V
Y=3.3V
M=10V
2=15V
L=28V
B=Product Grade
E=0°C to + 85°C Case
C=0°C to +85°C Case
I=-30°C to +85°C Case
Y=50W
X=75W
W=100W
V=150W
U=200W
D=Output Power / Current E=Output Power / Current
Vout >= 5V
W=100W
V=150W
U=200W
S=300W
Q=400W
Vout < 5V
20A
30A
40A
60A
80A
C=Output Power
Vout >= 5V
Vout >= 5V
Vout < 5V
S=300W
P=450W
M=600W
60A
90A
120A
Vout < 5V
10A
15A
20A
30A
40A
Options
CC Conduct’n Cooled
BM Bat Mod
BC Bat Mod + CC
Please consult Powerbox office for other output voltage and thermal
application notes.
72
Doc. No. PBC9 Rev.D 8-8-2012
FLATPAC Series
TECHNICAL ILLUSTRATIONS
ALL MODELS
LU SERIES
OPEN FRAME & ENCLOSED
5 0 - 6 0 0 W AT T S - A C / D C L O W P R O F I L E S I N G L E & M U LT I P L E O U T P U T
MU,PU SERIES
NU, QU, RU SERIES
Doc. No. PBC9 Rev.C 28-4-11
Powering Progress – www.powerbox.com.au
73