OPEN FRAME & ENCLOSED FLATPAC Series 5 0 - 6 0 0 W AT T S - A C / D C L O W P R O F I L E S I N G L E & M U LT I P L E O U T P U T FEATURES • • • • • • • • Inputs: 115/230VAC autoranging VDE/FCC Class A, Class B 1,2 or 3 Output Models Any output: 1 to 95VDC UL, CSA, TÜV, VDE, BABT, CE, C-Tick Remote sense and current limit OVP and thermal shutdown Any output 1 to 95V SPECIFICATIONS STANDARDS INPUT Voltage 110-240VAC Auto ranging Isolation Input to output: 4,242Vdc Input to FG: 2,121Vdc Output to FG: 707Vdc Efficiency Safety standards Surge Meets IEC801-5, Level 3 C-Tick AS/NZS CISPR11 Group 1, Class A EMC standards Conducted emissions EN55022, FCC Class B, radiated emissions Class A EMC immunity E EMC immunity IEC 61000-4,2,3,4,5,6,8 and 11 Dimensions (LxWxH) 78%-90% OUTPUT Product grade C, I Output voltage See selection table MECHANICAL Low-High 50%–110% 70%–110% Voltage trim program Yes Yes Output power See selection table Current limit Yes Yes Current limit setting 105%–125% 105%–135% OVP set point 125% 125% OVP and thermal Yes Yes Temperature shutdown Yes Yes Set point accuracy 0.5% 1% Dual output Output ripple 1.5% p-p 3% p-p Triple output Load/line regulation 0.05% typ 0.5% typ Holdup time 40mS 40mS Remote sense Yes Yes Compensation 0.5V Baseplate operating 85°C Temperature. Shutdown temperature 95°C 0.5V BUS OK status Yes Yes UL 1604, UL60950-1, UL/CSA/EN/IEC 60950-1 85°C 95°C AC OK status Yes Yes Module disable Yes Yes Single Output: VI-LU: 235x64x35mm. Single Output: VI-MU: 235x125x35mm. Single Output: VI-NU: 235x188x35mm. Dual Output: VI-PU: 235x125x35mm. Dual Output: VI-QU: 235x188x35mm. Triple Output: VI-RU: 235x188x35mm. SELECTION TABLE Single output VI-LU [ a ] – [ b ] [ c ] 50–200W VI-MU [ a ] – [ b ] [ d ] 200–400W VI-NU [ a ] – [ b ] [ e ] 300–600W VI-PU [ a ] [ a ] – [ b ] [ c ] [ c ] 100–400W VI-QU [ a ] [ a ] – [ b ] [ d ] [ c ] 150–600W VI-RU [ a ] [ a ] [ a ] – [ b ] [ c ] [ c ] [ c ] 150–600W Please substitute selection character, e.g. [ a ] [ b ] [ c ], with value designator in the appropriate table below. # For conduction cooled models add – cc at end of model number. A=Output Voltage Z=2V 0=5V 1=12V 3=24V 4=48V Y=3.3V M=10V 2=15V L=28V B=Product Grade E=0°C to + 85°C Case C=0°C to +85°C Case I=-30°C to +85°C Case Y=50W X=75W W=100W V=150W U=200W D=Output Power / Current E=Output Power / Current Vout >= 5V W=100W V=150W U=200W S=300W Q=400W Vout < 5V 20A 30A 40A 60A 80A C=Output Power Vout >= 5V Vout >= 5V Vout < 5V S=300W P=450W M=600W 60A 90A 120A Vout < 5V 10A 15A 20A 30A 40A Options CC Conduct’n Cooled BM Bat Mod BC Bat Mod + CC Please consult Powerbox office for other output voltage and thermal application notes. 72 Doc. No. PBC9 Rev.D 8-8-2012 FLATPAC Series TECHNICAL ILLUSTRATIONS ALL MODELS LU SERIES OPEN FRAME & ENCLOSED 5 0 - 6 0 0 W AT T S - A C / D C L O W P R O F I L E S I N G L E & M U LT I P L E O U T P U T MU,PU SERIES NU, QU, RU SERIES Doc. No. PBC9 Rev.C 28-4-11 Powering Progress – www.powerbox.com.au 73