Specification Sheet

SM3300 Series
L A B O R A T O R Y P O W E R S U P P LY
FEATURES
• 3300W Laboratory Supply
• Ranges 0-18V to 0-660V and 0-220A to 0-5.5A
• Designed for long life at full power
• Excellent dynamic response to load changes
• Protected against all overload and short circuit conditions
• EMC surpasses CE requirements
• Low audible noise - fans are temperature controlled
• Available options: Software control and interfaces
• High Speed Programming
• Two-Quadrant Output - PowerSink Operation on single and
three phase input voltages Large user display
• menu driven operations
• Durable digital encoders for voltage and current
adjustment
• Plug and play optional interfaces
SPECIFICATIONS
INPUT
MECHANICAL
Interlock
Stacking of units allowed, air flow is from
left to right.
Screw Terminals for cable 2.5-4mm, 3phase
+ earth (no neutral required)
M8 bolts
RJ45 connector for Ethernet (LAN) at rear
panel
Input for contact at rear panel
Enclosure
IP20 Protection
Dimensions
86 x 433 x 455mm Behind front panel
(feet removed)
88.1 x 483mm, Front panel
(19" 2U)
Weight
15kg
Input voltages
180-528Vac (1ph or 3ph)
Input Frequency
48 - 62Hz
Power Factor
0.99
Input Connector
Internal Fuse
7.5A rms, 25AT
Output Terminals
OUTPUT
Mounting
Programming Connector
Output Voltage Range
0-16V to 0-660V
Auto ranging models
See Selection Table
Output Current Range
0-220A to 0-5.5A
Auto ranging models
See Selection Table
Output Power Range
0 to 3300W
See Selection Table
ENVIRONMENTAL
STANDARDS & APPROVALS
Operating Temperature
-20°C to +50°C (100% load)
Derate output to 75% at 60°C
Safety
cTUVus/EN60950 / EN61010
Temperature coefficient
0.02%./°C
EMC
Storage temperature
-40°C to 85°C.
EN61204-3 Power Supply Standard
EN61000-6-3 (EN55022B) Generic Emission
EN61000-6-2 Generic Immunity
Thermal Protection
Output shuts down in case of insufficient
cooling
Humidity
max 95% RH, non condensing, up to 40C
max 75% RH, non condensing, up to 50C
www.powerbox.com.au - 1800 251 380
www.powerbox.co.nz - 0800 104 480
Doc. No. SM3300 Rev.A 3-12-15
SM3300 Series
L A B O R A T O R Y P O W E R S U P P LY
SPECIFICATIONS
OPERATING
STANDARD FEATURES
Remote ShutDown
> with +5V, 1mA or relay contact
Interlock
Contact at rear of panel
Indicators
Voltage meter, Amp meter, AC-Fail, DC-Fail, Over
Temperature, Power Sink Overload, Remote Shutdown,
Remote-CV, Remote-CC, Output On,CV-limite, CV- and
CC- mode
Digital voltage and
Current Setting
Reliable, longlife digital encoders are
implemented at the front panel.
Includes total front panel lock (also for
CV/CC knobs) and a coarse of fine pitch
adjustment depending on the turning speed
Ethernet Controller
A 16 bit Ethernet interface for programming
and monitoring
Sequencer
Arbitrary waveform generator or stand
alone automation
Controls
High voltage isolation
A higher output isolation allows series
operation up to 1320V
Series Operation
USB-Input
Front panel USB-input for exchange of
settings and wave forms (host)
Parallel Operation
Max total current - No limit
Master / Slave operation - max 4 units (including master)
Remote Sensing
Max volt, drop per load lead: 2V
Limits
Voltage adjust range: 0 - 102%
Current adjust range: 0 - 102%
AVAILABLE OPTIONS
High Speed Programming
A 10 to 20 times higher programming speed
(down to 0.2ms rise time at full load) and
lower output capacitance. Excellent for
laser applications, test systems or as
current source with low parallel
capacitance as used in plasma chambers
Software Control
and Interfaces
- Isolated Analog Programming
- Serial RS232, RS485, RS422, USB (host)
- Digital I/O
- Master/Slave
- Isolated contacts
- PROFIBUS
- CANBUS
Mains on/off switch, CV and VV potmeter, CV and CC limit
potmeter, Displlay Settings button, Display limits button,
Remote/Local button, Output On/off button, Fron panel
lock button
Max total voltage 600V
Master / Slave oeration yes
From front panel: Standard .03%
Potentiometers & Encoders Screw driver adj: Option P001 (at front panel)
Digital Encoders: Option P220
Efficiency
87% Typical
Isolation
Input - Output: 3750Vrms(1 min)
Creepage clearance; 8mm
Input - Case: 2500Vrms
Output - Case: 600VDC
MTBF
500,000hrs
SELECTION TABLE
OUTPUT
SM 18-220
SM 66-AR-110
SM 100-AR-75
SM 330-AR-22
SM 660-AR-11
Output Voltage Range
0 - 18V
0 - 66V
0 - 100V
0 - 330V
0 - 660V
Output Current Range
0 - 220A
0 - 110A
0 - 75A
0 - 22A
0 - 11A
Autoranging (2 Ranges)
No
Yes
Yes
Yes
Yes
Max Output Current/Voltage
-
0-33V / 0-110A
0-50V / 0-75A
0-165V / 0-22A
0-330V / 0-11A
-
0-66V / 0-55A
0-100V / 0-37.5A
0-330V / 0-11A
0-660V / 0-5.5A
Meters
4 digit
4 digit
4 digit
4 digit
4 digit
Scale voltage
0 - 18.00 V
0 - 66.0 V
0 - 100.0 V
0 - 300.0 V
0 - 600 V
Scale current
0 - 220 A
0 - 110.0 A
0 - 75.0 A
0 - 22.0 A
0 - 11.00 A
Accuracy
0.2% + 2 digit
0.2% + 2 digit
0.2% + 2 digit
0.2% + 2 digit
0.2% + 2 digit
PROGRAMMING SPEED
STANDARD VERSION
SM 18-220
SM 66-AR-110
SM 100-AR-75
SM 330-AR-22
SM 660-AR-22
0 - 15 / 18V
4 / 5.5 ms
2.2 / 2.6 ms
0 - 33 V
1.6 ms
1 ms
0 - 50 V
3.8 ms
2 ms
0 - 165 V
3.8 ms
2 ms
0 - 330 V
4.2 ms
2.5 ms
-
0 - 66 V
7 ms
3.7 ms
0 - 100 V
15 ms
8 ms
0 - 330 V
15 ms
8 ms
0 - 660 V
15 ms
7.5 ms
15/18V - 0 V
7 ms
32 ms
33 - 0 V
3 ms
33 ms
50 - 0 V
6 ms
65 ms
165 - 0 V
6 ms
65 ms
330 - 0 V
6 ms
70 ms
-
66 - 0 V
11 ms
100ms
100 - 0 V
26 ms
260 ms
330 - 0 V
25 ms
250 ms
660 - 0 V
28 ms
270 ms
RISE TIME (10 - 90%)
Output voltage step
Time, (load = 3300W)
Time, (load = 330W)
Output voltage step
Time, (load = 3300W)
Time, (load = 330W)
FALL TIME (90 - 10%)
Output voltage step
Time, (load = 3300W)
Time, (load 330W)
Output voltage step
Time, (load = 3300W)
Time, (load = 330W)
www.powerbox.com.au - 1800 251 380
www.powerbox.co.nz - 0800 104 480
Doc. No. SM3300 Rev.A 3-12-15
SM3300 Series
L A B O R A T O R Y P O W E R S U P P LY
TECHNICAL ILLUSTRATIONS
www.powerbox.com.au - 1800 251 380
www.powerbox.co.nz - 0800 104 480
Doc. No. SM3300 Rev.A 3-12-15
SM3300 Series
L A B O R A T O R Y P O W E R S U P P LY
TECHNICAL ILLUSTRATIONS
www.powerbox.com.au - 1800 251 380
www.powerbox.co.nz - 0800 104 480
Doc. No. SM3300 Rev.A 3-12-15