Specification Sheet

SM800 Series
L A B O R A T O R Y P O W E R S U P P LY
FEATURES
• 800W Laboratory Supply
• Ranges 0-7.5V to 0-400V and 0-80A to 0 - 4A
• Designed for long life at full power
• Excellent dynamic response to load changes
• Protected against all overload and short circuit conditions
• EMC surpasses CE requirements for low emission & high
Immunity Optional High speed programing. Interfaces Optional
• Extra Isolation. Sequencer. Digital Encoders. Power Sink Low
audible noise - fans are temperature controlled
• Master/Slave parallel and series operation with voltage and
current sharing
• High power system configuration from multiple units
• 19" rack mounting for for laboratory use (feet included)
• Stacking is allowed & space between units is not required
SPECIFICATIONS
INPUT
STANDARDS & APPROVALS
Input voltages
90 - 265Vac
Power supply standard
EN61204-3, CISPR22-Class B
Input Frequency
48 - 62Hz
General Emission
EN61000-6-3 (EN55022-B)
Power Factor
Better than 0.99 at full load
General Immunity
EN61000-6-2
Input Current
1.0A @ 230Vac
Safety
EN60950/EN61010
Inrush current
22A at 230VAC
MECHANICAL
Internal Fuse
12.5AT
Standby Input Current
14W when Vo = Io=0
OUTPUT
Mounting
Stacking of units allowed, air flow is from
left to right.
Input Connector
IEC320/C20, EN60320/C20
Output Terminals
M5 bolts
Programming Connector
15 pole D-connector at rear panel (FEMALE)
Output Voltage Range
0-7.5V to 0-400V
Auto ranging models
See Selection Table
Enclosure
IP20 Protection
Output Current Range
0-80A to 0-4A
Auto ranging models
See Selection Table
Dimensions
0 to 800W
See Selection Table
86 x 221 x 406mm Behind front panel
(feet removed)
89 x 222mm, Front panel
(1/2 19" 2U)
Weight
5.4kg
Output Power Range
ENVIRONMENTAL
Operating Temperature
-20°C to +50°C (100% load)
Derate output to 75% at 60°C
Temperature coefficient
0.02%./°C
Storage temperature
-40°C to 85°C.
Thermal Protection
Output shuts down in case of insufficient cooling
Humidity
max 95% RH, non condensing, up to 40°C
max 75% RH, non condensing, up to 50°C
www.powerbox.com.au - 1800 251 380
www.powerbox.co.nz - 0800 104 480
Doc. No. SM800 Rev.D 3-12-15
SM800 Series
L A B O R A T O R Y P O W E R S U P P LY
SPECIFICATIONS
OPERATING
ANALOG PROGRAMMING
Relay Outputs
ACF: AC-Fail, both NOP and NC contact
DCF: DC-Fail,both NO and NC contact
output voltages +/-5% beyond set point
Input Range: 0 - 5V
Accuracy: +/-0.5%
Offset: 0...+2.2mV (on 5V)
Temp. coeff. offset:: 50uV/C
Input Impedance: > 1Mohm
Status Outputs
CC operation: 5V = logic1, (Ro = 500 Ohm)
CV or CC limit: 5V = logic1, (Ro = 500 Ohm)
OT: Over Termp: 5V = logic1, (Ro = 500 Ohm)
PSOL, Powersink Overload: 5V = logic1, (Ro = 500 Ohm)
ACF, AC Fail: 5V = logice1, (Ro = 500 Ohm)
DCF DC Fail 5V = logice1, (Ro = 500 Ohm)
Remote ShutDown
> with +5V, 1mA or relay contact
Interlock
Contact at rear of panel
Monitoring Outputs: CV
Input Range: 0 - 5V
Accuracy: +/-0.2%
Offset: -1.1..0mV (on 5V)
Temp. coeff. offset:: 3uV/C
Output Impedance: > 2 ohm / max 4mA
Indicators
Voltage meter, Amp meter, AC-Fail, DC-Fail, Over
Temperature, Power Sink Overload, Remote Shutdown,,
Remote-CV, Remote-CC, Output On,CV-limite, CV- and
CC- mode
Monitoring Outputs: CC
Input Range: 0 - 5V
Accuracy: +/-0.5%
Offset: -1.1..0mV (on 5V)
Temp. coeff. offset:: 60uV/C
Output Impedance: > 2 ohm / max 4mA
Reference voltage
Vref: 5.114V +/-15mV
(Ro = 2ohm, max 4mA) TC: 20ppm
Programming Inputs: CV
Programming Inputs: CC
+12V output
Input Range: 0 - 5V
Accuracy: +/-0.2%
Offset: -0.1...+1.3mV (on 5V)
Temp. coeff. offset:: 10uV/C
Input Impedance: > 1Mohm
Mains on/off switch, CV and VV potmeter, CV and CC limit
potmeter, Displlay Settings button, Display limits button,
Remote/Local button, Output On/off button, Fron panel
lock button
Max total voltage 600V
Master / Slave oeration yes
Controls
Series Operation
Vo: 12V+/-0.23V
Imax: 0.2A
Ro: 3ohm
Parallel Operation
Max total current - No limit
Master / Slave operation - max 4 units (including master)
Remote Sensing
Max volt, drop per load lead: 2V
Limits
Voltage adjust range: 0 - 102%
Current adjust range: 0 - 102%
From front panel: Standard .03%
Potentiometers & Encoders Screw driver adj: Option P001 (at front panel)
Digital Encoders: Option P220
Efficiency
87% Typical
Isolation
Input - Output: 3750Vrms(1 min)
Creepage clearance; 8mm
Input - Case: 2500Vrms
Output - Case: 600VDC
MTBF
500,000hrs
SELECTION TABLE
OUTPUT
SM 7.5-80
SM 18-50
SM 70-AR-24
SM 400-AR-4
Output Voltage Range
0 - 7.5V
0 - 18V
0 - 70V
0 - 400V
Output Current Range
0 - 80A
0 - 50A
0 - 24A
0 - 4A
Autoranging (2 Ranges)
No
No
Yes
Yes
Max Output Current/Voltage
-
-
24A / 0-35V
4A / 0-200V
-
-
12A / 35 - 70V
2A / 200 - 400V
Meters
3.5 digit
3.5 digit
3.5 digit
3.5 digit
Scale voltage
0 - 7.500 V
0 - 18.0 V
0 - 70.0 V
0 - 400.0 V
Scale current
0 - 80 A
0 - 50.0 A
0 - 24.0 A
0 - 4.0 A
Accuracy
0.5% + 2 digit
0.5% + 2 digit
0.5% + 2 digit
0.5% + 2 digit
www.powerbox.com.au - 1800 251 380
www.powerbox.co.nz - 0800 104 480
Doc. No. SM800 Rev.D 3-12-15
SM800 Series
L A B O R A T O R Y P O W E R S U P P LY
SELECTION TABLE
PROGRAMMING SPEED
STANDARD VERSION
Rise time (10 - 90%)
Output voltage step
Time, (100 % load)
Time, (10 % load)
Output voltage step
Time, (100 % load)
Time, (10 % load)
Fall time (90 - 10%)
Output voltage step
Time, (100 % load)
Time, (10 % load)
Output voltage step
Time, (100 % load)
Time, (10 % load)
SM 7.5-80
SM 18-50
SM 70-AR-24
SM 400-AR-4
0 - 7.5 V
6.5 ms
2.5 ms
0 - 16 V
12 ms
5 ms
0 - 35 V
6 ms
2.5 ms
0 - 200 V
4 ms
2 ms
-
-
0 - 70 V
10 ms
7 ms
0 - 400 V
8 ms
5 ms
7.5 - 0 V
6.5 ms
62 ms
16 - 0 V
12 ms
120 ms
35 - 0 V
6 ms
60 ms
200 - 0 V
4 ms
42 ms
-
-
70 - 0 V
25 ms
250 ms
400 - 0 V
15 ms
155 ms
TECHNICAL ILLUSTRATIONS
www.powerbox.com.au - 1800 251 380
www.powerbox.co.nz - 0800 104 480
Doc. No. SM800 Rev.D 3-12-15
SM800 Series
L A B O R A T O R Y P O W E R S U P P LY
TECHNICAL ILLUSTRATIONS
www.powerbox.com.au - 1800 251 380
www.powerbox.co.nz - 0800 104 480
Doc. No. SM800 Rev.D 3-12-15