SM3000 Series L A B O R A T O R Y P O W E R S U P P LY FEATURES • 3000W Laboratory Supply • Ranges 0-15V to 0-300V and 0-10A to 0-200A • Auto Ranging Models • Designed for long life at full power • Excellent dynamic response to load changes • Protected against all overload and short circuit conditions • EMC surpasses CE requirements - low emissions & high immunity • Low audible noise - fans are temperature controlled • Master/Slave parallel and series operation with voltage & current sharing • High power system configuration from multiple units • 19" rack mounting for for laboratory use (feet included) • Stacking is allowed & space between units is not required SPECIFICATIONS INPUT STANDARDS & APPROVALS Input voltages 342 - 457Vac 3Ph Safety EN60950 / EN61010 Input Frequency 48 - 62Hz Power Factor 0.88, with 100% load 0.78 with 50% load Power Supply Standard EN61204-3 Emission residential light industrial environment CISP22 Class B Immunity - industrial environment Input Current 5.8A rms (400Vac 3ph) Internal Fuse 16 AT General Emission Standby input power 25W Vo = 0 50W Vo = max EN61000-6-3 residential, light industrial environment EN55022B EN61000-6-2, industrial environment MECHANICAL Efficiency 89% Typical MTBF 500 000 hrs Turn on delay 300ms (after mains switch on) 6ms 100% load Vin=3x380Vac 15ms 50% load Vin=3x380Vac Hold-up time OUTPUT Output Voltage Range Output Current Range Output Power Range 0-15V to 0-300V Auto ranging models See Selection Table 0-200A to 0-10A Auto ranging models See Selection Table 0 to 3000W See Selection Table Mounting Stacking of units allowed, air flow is from left to right. Input Connector Screw terminals for cable 1.5 - 4.0mm2 3 phase + earth (no neutral required) Output Terminals 0-15V, 0-30V, 0-45V: M10 bolts 0-70V, M8 bolts 0-120V, 7mm bind post 0-300V, 6mm bind post Programming Connector 15 pole D-connector at rear panel (FEMALE) Enclosure IP20 Protection Dimensions 158 x 443 x 416mm Behind front panel (feet removed) 128 x 483mm, Front panel (19" 3U) Weight 15kg ENVIRONMENTAL Operating Temperature -20°C to +50°C (100% load) Derate output to 75% at 60°C Temperature Coefficient 0.02%./°C Storage Temperature -40°C to 85°C. Thermal Protection Output shuts down in case of insufficient cooling Humidity max 95% RH, non condensing up to 40°C max 75% RH, non condensing up to 50°C www.powerbox.com.au - 1800 251 380 www.powerbox.co.nz - 0800 104 480 Doc. No. SM3000 Rev.D 2-12-15 SM3000 Series L A B O R A T O R Y P O W E R S U P P LY SPECIFICATIONS PROGRAMMING Programming Inputs: CV Programming Inputs: CC Monitoring Outputs: CV Monitoring Outputs: CC Reference voltage +12V Output OPERATING Input Range: 0 - 5V Accuracy: +/-0.2% Offset: -0.1...+1.3mV (on 5V) Temp. coeff. offset:: 10uV/C Input Impedance: > 1Mohm Input Range: 0 - 5V Accuracy: +/-0.5% Offset: 0...+2.2mV (on 5V) Temp. coeff. offset:: 50uV/C Input Impedance: > 1Mohm Input Range: 0 - 5V Accuracy: +/-0.2% Offset: -1.1..0mV (on 5V) Temp. coeff. offset:: 3uV/C Output Impedance: > 2 ohm / max 4mA Input Range: 0 - 5V Accuracy: +/-0.5% Offset: -1.1..0mV (on 5V) Temp. coeff. offset:: 60uV/C Output Impedance: > 2 ohm / max 4mA Vref: 5.114V +/-15mV (Ro = 2ohm, max 4mA) TC: 20ppm Vo: 12V+/-0.23V Imax: 0.2A Ro: 3ohm Series Operation Max total voltage 600V Master / Slave operation yes Parallel Operation Max total current - No limit Master / Slave operation - max 4 units (including master) Remote Sensing Max volt, drop per load lead: 2V Potentiometers & Encoders Standard: Front panel control with knobs Resolution: 0.03% Screwdriver adjustment Option P001 Digital encoders Option P002 Indicators Voltage meter, Amp meter, AC-Fail, DC-Fail, Over Temperature, Power Sink Overload, Remote Shutdown,, Remote-CV, Remote-CC, Output On,CV-limite, CV- and CC- mode Controls Mains on/off switch, CV and VV potmeter, CV and CC limit potmeter, Displlay Settings button, Display limits button, Remote/Local button, Output On/off button, Fron panel lock button Relay Outputs ACF: AC-Fail, both NOP and NC contact DCF: DC-Fail,both NO and NC contact output voltages +/-5% beyond set point Status Outputs CC operation: 5V = logic1, (Ro = 500 Ohm) CV or CC limit: 5V = logic1, (Ro = 500 Ohm) OT: Over Termp: 5V = logic1, (Ro = 500 Ohm) PSOL, Powersink Overload: 5V = logic1, (Ro = 500 Ohm) ACF, AC Fail: 5V = logice1, (Ro = 500 Ohm) DCF DC Fail 5V = logice1, (Ro = 500 Ohm) Efficiency 87% Typical Isolation Input - Output: 3750Vrms(1 min) Creepage clearance; 8mm Input - Case: 2500Vrms Output - Case: 600VDC MTBF 500,000hrs SELECTION TABLE OUTPUT SM 15-200D SM 30-100D SM 45-70D SM 70-45D SM 120-25D SM 300-10D Output Voltage Range 0 - 15V 0 - 30V 0 - 45V 0 - 70V 0 - 120V 0 - 300V Output Current Range 0 - 200A 0 - 100A 0 - 70A 0 - 45A 0 - 25A 0 - 10A Meters 3.5 digit 3.5 digit 3.5 digit 3.5 digit 3.5 digit 3.5 digit Scale voltage 0 - 15.00 V 0 - 30.0 V 0 - 45.0 V 0 - 70.0 V 0 - 120.0 V 0 - 300 V Scale current 0 - 200 A 0 - 100.0 A 0 - 70.0 A 0 - 45.0 A 0 - 25.0 A 0 - 10.00 A Accuracy 0.5% + 2 digit 0.5% + 2 digit 0.5% + 2 digit 0.5% + 2 digit 0.5% + 2 digit 0.5% + 2 digit PROGRAMMING SPEED STANDARD VERSION SM 15-200 D OPTION P104 SM 30-100 D OPTION P031 SM 45-70 D OPTION P1 SM 70-45 D OPTION P032 SM120-25 D OPTION P106 SM300-10D OPTION P061 Rise time (10 - 90%) Output voltage step Time, (100 % load) Time, (10 % load) 0 - 15 V 7 ms 7 ms 0 - 30 V 7 ms 7 ms 0 - 45 V 7 ms 7 ms 0 - 70 V 7 ms 7 ms 0 - 120 V 7 ms 7 ms 0 - 300 V 7 ms 7 ms Fall time (90 - 10%) Output voltage step Time, (100 % load) Time, (10 % load) 15 - 0 V 7 ms 32 ms 30 - 0 V 7 ms 58 ms 45 - 0 V 87 ms 29 ms 70 - 0 V 8 ms 82 ms 120 - 0 V 7 ms 39 ms 300 - 0 V 11 ms 91 ms Programming bandwidth Small signal Large signal,(100 % load) Large signal,(10 % load) 50 Hz 50 Hz 5 Hz 50 Hz 50 Hz 5 Hz 50 Hz 50 Hz 5 Hz 50 Hz 50 Hz 5 Hz 50 Hz 50 Hz 5 Hz 50 Hz 50 Hz 5 Hz www.powerbox.com.au - 1800 251 380 www.powerbox.co.nz - 0800 104 480 Doc. No. SM3000 Rev.D 2-12-15 SM3000 Series L A B O R A T O R Y P O W E R S U P P LY TECHNICAL ILLUSTRATIONS www.powerbox.com.au - 1800 251 380 www.powerbox.co.nz - 0800 104 480 Doc. No. SM3000 Rev.D 2-12-15