1U Ultra Compact System 1 0 0 0 - 4 0 0 0 W AT T S T E L E C O M R E C T I F I E R S Y S T E M S FEATURES • • • • • • • • • • 1000W - 4000W Configurable Battery Charging System 1U 19" Rack Mounting Network Monitoring N+1 Operation System Monitoring Load & Battery MCBs Battery LVD Customized shelf configurations available Fully Featured Telecom Grade Rectifier SPECIFICATIONS MONITORING & CONTROL INPUT AC input 240V AC (90-300V) Single phase Display Frequency range 45-66 Hz Power factor >0.99 full load Termination Single phase, 6 or 10mm² L, N, E tunnel terminals Serial: 1x USB port on front panel for local PC interface TCP/IP: Ethernet interface for communication using SNMP Communications protocol and internal web based configurator* Modbus: Supported via TCP/IP* Termination DC OUTPUTT Nominal voltage Rated system output power Polarity LED Indicators 48V (+48V or +24V optional)* 4k Watts @ -48V 2k Watts @ 24V Positive earth, (negative earth option available) DC DISTRIBUTION Load Signal Inputs Battery Low voltage disconnect See Shelf configuration system Breaker fail detection Controls Standard Shelf configuration. (Customized configuration available)* Standard Shelf configuration (Customized configuration available)* Electronic fail detection on both load and battery breakers Tunnel terminals 10 mm² Battery Audible ENVIRONMENTAL REQUIREMENTS Ambient Temperature -20ºC to +70ºC Storage Temperature -30ºC to +85ºC Humidity 5-95% RH (non-condensing) Altitude <2,500m at full power Alarms Alarm Contacts 482.6mm (standard 19" module), 44.45mm (1U), 285mm Weight 5kg (excluding rectifier modules) Shipping Dimensions W, H, D 540.0mm, 95.0mm, 400.0mm Shipping Weight 6.0kg (excluding rectifier modules) Green: Power on/monitor OK Yellow: Non urgent alarm Red: Urgent alarm 90dBA buzzer mappable to user defined conditions 3x push buttons for parameter setting or viewing on front panel Serial bus for rectifier control and interface to peripheral modules 6x digital inputs 2x temperature sensors (one fitted by default) 6x alarm relays, 5x of which can be mapped for customised alarm settings 0.3A 100V volts free changeover contacts Periodic log, 16,384 records (dependant on number of parameters logged) Logging Capacity Event log, 16,384 records (dependant on number of parameters logged) Connections Relay outputs, mini combicon to accept 1.5mm² wire USB port, USB mini B *TCP/IP and modbus options only available with SM36 supervisory module. CONFIGURATION AND OPTIONS MECHANICAL Dimensions W, H, D Multi-lingual alpha numeric backlit display Rectifiers Supervisory Modules ARBP-1M RM2048XE: 2.0kW modular rectifier, 230V AC input, 48V DC output, 41.7A maximum output RM2048HE: 2.0kW modular rectifier, 230V AC input, 48V DC output, 41.7A maximum output RM2048/24: 2.0kW modular rectifier, 230V AC input, 48 or 24V DC output, 41.7A maximum output RM1860/48: 1.8kW modular rectifier, 230V AC input, 60 or 48V DC output, 30.0A maximum output SM35: standard monitor featuring full temperature compensation, automated and manual battery testing/equalisation SM36: enhanced monitor featuring full temperature compensation, automated and manual battery testing/equalisation with TCP/IP Metal rectifier blanking panel ASM-ABM24 (-24-48-60) Battery condition monitor for 24, 48 or 60V battery strings ASM-AC3P AC mains monitor 1U Ultra Compact System 1 0 0 0 - 4 0 0 0 W AT T S T E L E C O M R E C T I F I E R S Y S T E M S TECHNICAL ILLUSTRATIONS MODEL NUMBER MAX RECTIFIERS MAX SHELF POWER DC DISTRIBUTION 24, 48 or 60VDC 1 x load circuit breaker (6-63A) 4.0kW 1 x battery circuit breaker (max 63A) Positive or negative earth 80A Magnetically latching battery LVD 24, 48 or 60VDC 1 x load circuit breaker (6-63A) 4.0kW 1 x battery circuit breaker (max 63A) PSC04 V2 2 Positive or negative earth 80A Magnetically latching battery LVD *System part numbers are dependent on configuration options. For final system part numbers consult our sales staff for configuration advice. PSC04 V1 2 TECHNICAL ILLUSTRATIONS Powering Progress – www.powerbox.com.au