DABI AD2T-FB

Bridge Amplifier for Strain Gage Full Bridge
DABI AD2T-FB
Features
• Industrial bridge amplifier
for S/G full bridge
• For cyclical and static applications
with reset function
• Current output
• Protection class IP 65
• Analog signal path
Electrical Data
Order Code
Supply voltage range
14 - 33 VDC
Current draw
< 90 mA
< 70 mA @ 24 VDC
Burden
< 500 Ω
Tare accuracy
0.25 < 30 µA
0.50 < 20 µA
1.00 < 16 µA
2.00 < 16 µA
Reset input Dimensions (mm)
active 5 - 33 VDC < 2 mA
inactive< 1 VDC
Tare range
±6 mV/V
Reset puls
> 1 ms
Reset settle time
< 5 ms
Frequency range (-3 dB) 1'000 Hz
Noise
(0 ... 5 kHz)
0.25 < 15 µApp
0.50 < 7,5 µApp
1.00 < 5 µApp
2.00 < 5 µApp
Mechanical Data
4
40
40
29
≥ 350 Ω
Gain
0.50 0,50 mV/V = 4 - 20 mA
1.00 1,00 mV/V = 4 - 20 mA
2.00 2,00 mV/V = 4 - 20 mA
79
79
Delivery Contents
• Mounting screw 2 pcs. M4 x 30
Accessories (not included in delivery)
Series 713
Connector female, control side, 5-pin, Part No. 10135462
max. cable length 20 m
Control connection5 pin male (Series 713)
M12 x 1
Sensor connection4 pin female (Series 712)
Enclosurealuminum anodised
Connector female with cable, control side, 5-pin
Environmental Conditions
ESG 34CH0200G 5-pin (shielded) 2 m, PUR,
(Part No. 11046264)
Operating temp. range-25...+85 °C
Specified temp. range0...+70 °C
Storage temperature-40...+100 °C
Protection classIP 65
ESG 34CH0500G 5-pin (shielded) 5 m, PUR,
(Part No. 11046266)
ESG 34CH1000G 5-pin (shielded) 10 m, PUR,
(Part No. 10155587)
EMCEN 61000-6-2 Immunity
EN 61000-6-3 Emission
6.10
4
26
M12 x1
approx. 7 VDC
S/G bridge resistance
M12 x1
Bridge excitation
DABI AD2T-FB
1.00 < 0,2%
2.00 < 0,2%
14
0.25 < 0,5%
0.50 < 0,25%
14
4 - 20 mA calibrated
Characteristic curve deviation
29
Output signal
www.baumer.com
26
DABI AD2T-FB
Electrical Connection
Control side Series 713
Sensor side Series 712
Pin
2
3
4 5
3
1
4
1
2
Pin number
Signal
EXC.+
Signal
1
Full bridge
EXC.+
1+Vs
2
Full bridge
SIG.-
2n.c.
3
Full bridge
SIG.+
3GND
4
Full bridge
EXC.-
4+IOUT
5
SIG.+
SIG.-
EXC.-
Reset
Control
Transducer
S/G Bridge
Reset Function
max. 10m
DABI
mV/V
EXC.+ 1
SIG.-
max. 20m
Control Unit
1 +VS
6
14 - 33VDC
3 GND
2
SIG.+ 3
2
EXC.- 4
4 +IOUT
I
5 Reset
RL
4 - 20mA
5 - 33 VDC
Potential equalisation
www.baumer.com
IOUT
Output signal
mV/V
Input signal
Reset
Reset input (active high)
t1
Reset delay (< 0,3 ms)
t2
Reset time (< 5 ms)
t3
Reset impuls (> 1 ms)
6.11