DC-AC INVERTER UNIT

DC-AC INVERTER UNIT
PS-DA0201-316(S) (10 W DUAL OUTPUTS)
(PRELIMINARY INFORMATION)
DESCRIPTION :
This low profile DC/AC inverter is developed for dual lamps.
Optimized for AUO: G150XG03 V3
APPLICABLE LCD:
6.4 to 15 inches double lamps
Lamp voltage 600 Vrms
Lamp current 2 x 8 mArms
Lamp Start Up Voltage 1.500 Vrms (Vin : 12 Vdc)
FEATURES :
Remote ON/OFF
Open lamp detection
RoHS compliant (S)
TEMPERATURE & HUMIDITY :
Operating Temperature Range
Storage Temperature Range
Humidity
DIMENSIONS :
LxWxH
-10°C ~ +50°C
-40°C ~ +85°C
95 %RH max
Unit : mm
Weight :24,2 (g) typ.
160 x 25 x 10 mm
Note: Please use plastic screw in case of a non-insulating mounting base!
Components
No.
1
2
3
Part Description
PCB
Connector CN1
Connector CN2 + CN3
Input side CN1:
Pin No. Symbols
Vin
CN 1-1
GND
CN 1-2
Vrmt
CN 1-3
Vbr
CN 1-4
CN 1-5
Qty.
1
1
2
Material
UL94V-0 (FR-4 or CEM-3)
S5B-PH-K
SM02(8.0)B-BHS-1-TB
Note
t=1mm
JST or equal
JST or equal
Output side CN2:
Ratings
10.8 ~ 13.2 Vdc
0 ~ 0.4 = OFF / 2.5 ~ Vin = ON
0 ~ 2.5 Vdc
N.C.
Pin No.
CN 2-1
CN 2-2
Ratings
600 Vrms (8 mArms)
(GND)
Output side CN3:
Pin No.
CN 3-1
CN 3-2
-
Symbols
Vhigh
Vlow
Symbols
Vhigh
Vlow
Ratings
600 Vrms (8 mArms)
(GND)
Power Systems – The Power Solution
Web:
Email:
www.Power-Systems.de
[email protected]
All specifications are subject to change without notice.
Address: Hauptstr. 48 ; 74360 Ilsfeld-Auenstein / Germany
Tel. :
+ 49 / 70 62 / 67 59 - 6
Fax:
+ 49 / 70 62 / 67 59 - 800
Page (1)
Version 1.0.1, 21st May 2014
DC-AC INVERTER UNIT
PS-DA0201-316(S) (10 W DUAL OUTPUTS)
(PRELIMINARY INFORMATION)
ELECTRICAL CHARACTERISTICS :
Conditions
Parameters
Symbols
Output Current
Output Current
Input Current
Frequency
Open Circuit Voltage
No load Shutdown
Iout
Iout
Iin
F
Vopen
Tsd
Note 1 :
Note 2:
Specification
Vin (V)
Vbr (V)
Tu (°C)
Min.
Typ.
Max.
12±1.2
12±0.6
12±1.2
12±1.2
11.4
12±1.2
0.0
2.5
0.0
0.0
0.0
0.0
-10 ~ +50
-10 ~ +50
-10 ~ +50
-10 ~ +50
-10 ~ +50
-10 ~ +50
7.5
45
1.300
-
8.0
30
1.1
50
1.500
1.0
8.5
1.3
55
1.900
-
Unit
Note
mArms
%
Adc
kHz
Vrms
sec
Dut y 100%
Dut y M in
wit hout load
Please keep a minimum of 2mm clearance in all directions between inverter high voltage areas
and any conductors.
Please provide Vcc before applying any control signals into inverter.
Reverse the sequence during power off which is control signal off first then Vcc.
TEST CIRCUIT :
SW 1
Operation of unit
a
Operation
b
Non operation
Power Systems – The Power Solution
Web:
Email:
www.Power-Systems.de
[email protected]
All specifications are subject to change without notice.
Address: Hauptstr. 48 ; 74360 Ilsfeld-Auenstein / Germany
Tel. :
+ 49 / 70 62 / 67 59 - 6
Fax:
+ 49 / 70 62 / 67 59 - 800
Page (2)