MAD100 SERIES

MAD100
MAD100 SERIES
2 X 3 Inch AC-DC POWER SUPPLIES
UNIVERSAL INPUT RANGE
UP TO 100Watts
FEATURES
APPLICATIONS
• LOW STANDBY POWER CONSUMPTION UNDER 0.3 WATT
• WIDE INPUT VOLTAGE RANGE 85 TO 264VAC, 47 TO 63HZ
• ACTIVE POWER FACTOR CORRECTION
• BUILT-IN EMI FILTER
• OUTPUT VOLTAGE ADJUSTABLE
• OPEN FRAME DIMENSIONS 2.00 X 3.00 X 1.16 INCH
• 4000VAC INPUT TO OUTPUT 2MOPP INSULATION
• PROTECTION TYPE CLASS I AND CLASS II
• LOW LEAKAGE CURRENT UNDER 75µA
• OPERATING ALTITUDE 5000M
• 5 YEAR WARRANTY
• ANSI/AAMI ES60601-1, EN60601-1, & IEC60601-1 3rd EDITION SAFETY APPROVALS
• CE MARKED
• COMPLIANT TO RoHS II & REACH
4000VAC
ISOLATION
OCP
SCP
OVP
• MEDICAL EQUIPMENT
LOW
STANDBY
POWER
PART NUMBER STRUCTURE
M
A
D
100
U
S
12
Application
Package
Code
Dimension
Code
Output
Power
(W)
Input
Voltage
(VAC)
Output
Quantity
Output
Voltage
(VDC)
U:Universal
S:Single
12: 12V
No suffix: CLASS I
15: 15V
B: CLASS II
Medical
Application
A: Open type
U: U chassis type
85 ~ 264VAC
E: Enclosed type
24: 24V
D: Din rail type
28: 28V
Protection
Type
36: 36V
48: 48V
1
www.PDUKE.com
2015/3/16
MAD100
TECHNICAL SPECIFICATION All specifications are typical at 230VAC input, full load and 25℃ otherwise noted
Input
Range
Output
Voltage
Output Current
Natural convection
Input Power
No Load
Efficiency
VAC
VDC
A
W
%
85 ~ 264
12
8.34
0.3
91
85 ~ 264
15
6.67
0.3
92
85 ~ 264
24
4.17
0.3
92
85 ~ 264
28
3.58
0.3
92
85 ~ 264
36
2.78
0.3
91
85 ~ 264
48
2.09
0.3
91
Model
Number
MAD100US12
MUD100US12
MED100US12
MDD100US12
MAD100US15
MUD100US15
MED100US15
MDD100US15
MAD100US24
MUD100US24
MED100US24
MDD100US24
MAD100US28
MUD100US28
MED100US28
MDD100US28
MAD100US36
MUD100US36
MED100US36
MDD100US36
MAD100US48
MUD100US48
MED100US48
MDD100US48
INPUT SPECIFICATIONS
Parameter
Operating input voltage range
Input frequency
Input current
No load input power
Leakage current
Power Factor
Start up time
Rise time
Hold up time
Input inrush current
Input protection
2
Conditions
AC input
DC input
AC input
115VAC and Full Load
230VAC and Full Load
230VAC
264VAC
Min.
Typ.
85
120
47
Max.
Unit
264
370
63
1.15
0.55
0.3
75
VAC
VDC
Hz
A
Watts
µA
0.95
1000
20
115VAC and Full Load
230VAC
Internal fuse in line and neutral
www.PDUKE.com
16
60
T3.15A/250VAC
ms
ms
ms
A
2015/3/16
MAD100
OUTPUT SPECIFICATIONS
Parameter
Output power
Initial set voltage accuracy
Line regulation
Load regulation
Voltage adjustability
Minimum load
Ripple and noise
Temperature coefficient
Transient response
Over voltage protection
Over load protection
Short circuit protection
Conditions
230VAC and Full Load
Low Line to High Line at Full Load
No Load to Full Load
10% Load to 90% Load
12Vout
15Vout
24Vout
28Vout
36Vout
48Vout
Max.
Unit
100
+1.0
+0.2
+0.5
+0.4
+10
Watts
%
%
120
150
160
180
190
340
-0.02
Peak deviation
Recovery time
Load step form 50 ~ 75% change at 2.5A/µs
% of Vout(nom); Latch mode
% of Iout rated; Hiccup mode
Conditions
1 minute (2MOPP insulation)
Isolation resistance
Switching frequency
Safety approvals
500VDC
Weight
Min.
Input to Output
Input (Output) to F.G.
4000
1500
0.1
MIL-HDBK-217F Ta=25℃, Full load
Conditions
Natural convection
Min.
With derating
Non-condensing
www.PDUKE.com
%
%
%
mVp-p
%/℃
% Vout
µs
500
115
135
%
115
150
%
Continuous, automatics recovery
MAD
MUD
MED
MDD
ENVIRONMENTAL SPECIFICATIONS
Parameter
3
-1.0
-0.2
-0.5
-0.4
-10
Measured by 20MHz bandwidth
With a 10µF/25V 1206 X7R MLCC
With a 10µF/25V 1206 X7R MLCC
With a 1µF/50V 1206 X7R MLCC
With a 1µF/50V 1206 X7R MLCC
With a 1µF/50V 1206 X7R MLCC
With a 0.1µF/100V 1206 X7R MLCC
Isolation voltage
Operating ambient temperature
Storage temperature range
Operating altitude
Thermal shock
Shock
Vibration
Relative humidity
Typ.
0
GENERAL SPECIFICATIONS
Parameter
MTBF
Min.
-25
-40
+0.02
3
Typ.
Max.
Unit
VAC
GΩ
60
kHz
ANSI/AAMI ES60601-1
EN60601-1
IEC60601-1
156g (5.50oz)
194g (6.84oz)
210g (7.41oz)
232g (8.18oz)
7.903 x 105 hrs
Typ.
Max.
Unit
+85
℃
+85
℃
5000
m
MIL-STD-810F
IEC68-2-27
IEC68-2-6
5% to 95% RH
2015/3/16
MAD100
EMC SPECIFICATIONS
Parameter
Conditions
EMI
EN55011, EN55022 and FCC Part 18
Harmonic currents
Voltage flicker
ESD
Radiated immunity
Fast transient
Surge
Conducted immunity
Power frequency magnetic field
EN61000-3-2
EN61000-3-3
EN61000-4-2
EN61000-4-3
EN61000-4-4
EN61000-4-5
EN61000-4-6
EN61000-4-8
Dip and interruptions
EN60601-1-2
Level
Conducted
Radiated
Full Load
Class B
Class A
Class A and D
Air ± 8kV and Contact ± 6kV
20 V/m
± 2kV
DM ± 1kV and CM ± 2kV
20 Vr.m.s
10 A/m
30%
60%
230VAC 50Hz
>95%
>95%
30%
60%
100VAC 50Hz
>95%
>95%
Perf. Criteria A
Perf. Criteria A
Perf. Criteria A
Perf. Criteria A
Perf. Criteria A
Perf. Criteria A
Perf. Criteria A
Perf. Criteria A
Perf. Criteria A
Perf. Criteria B
Perf. Criteria A
Perf. Criteria B
Perf. Criteria A
Perf. Criteria B
500mS
100mS
10mS
5000mS
500mS
100mS
10mS
5000mS
CHARACTERISTIC CURVE
Derating Curve vs. Ambient Temperature
MED100 & MDD100
Derating Curve vs. Ambient Temperature
MAD100 & MUD100
Derating Curve vs. Input Voltage
M D100
Efficiency vs. Output Load
M D100US24
4
Efficiency vs. Input Voltage
M D100US24
www.PDUKE.com
2015/3/16
MAD100
MECHANICAL DRAWING
MAD
Open type
MED Enclosed type
MDD
Din rail type
MUD
U chassis type
1. All dimensions in inch (mm)
2. Tolerance : x.xx±0.02 (x.x±0.5) x.xxx±0.01 (x.xx±0.25)
3. M3×0.5 screw locked torque MAX 5Kgf.cm/0.49N.m
CONNECTORS CONNECTIONS
CON1 – Input Connector
Pin 1
Pin 3
CON2 – Output Connector
Line
Neutral
Mates with
JST housing : VHR-3N
JST crimp terminals : SVH-21T-P1.1
5
Pin 1,2
Pin 3,4
Mounting holes marked with
must be
connected to safety earth for CLASS I application
www.PDUKE.com
-Vout
+Vout
Mates with
JST housing : VHR-4N
JST crimp terminals : SVH-21T-P1.1
2015/3/16