MAD65 SERIES

MAD65
SERIES
SINGLE -OUTPUT
2 X 3 Inch AC-DC POWER SUPPLIES
UNIVERSAL INPUT RANGE
UP TO 65Watts
FEATURES
APPLICATIONS
• 0.11 WATT LOW STANDBY POWER CONSUMPTION
• WIDE INPUT VOLTAGE RANGE 85 TO 264VAC, 47 TO 63HZ
• BUILT-IN CLASS B EMI FILTER
• OUTPUT VOLTAGE ADJUSTABLE (SINGLE OUTPUT ONLY)
• 4000VAC INPUT TO OUTPUT 2MOPP INSULATION
• PROTECTION TYPE CLASS I AND CLASS II
• LOW LEAKAGE CURRENT UNDER 75µA
• OPERATING ALTITUDE 5000M
• 5 YEAR WARRANTY
• ANSI/AAMI ES60601-1, EN60601-1, & IEC60601-1 3rd EDITION SAFETY APPROVALS
• CE MARKED
• COMPLIANT TO RoHS II & REACH
4000VAC
ISOLATION
OCP
SCP
OVP
• MEDICAL EQUIPMENT
• WIRELESS NETWORK
• TELECOM/DATACOM
• INDUSTRY CONTROL SYSTEM
• MEASUREMENT EQUIPMENT
• SEMICONDUCTOR EQUIPMENT
LOW
STANDBY
POWER
PART NUMBER STRUCTURE
M
A
D
65
U
S
12
Application
Package
Code
Dimension
Code
Output
Power
(W)
Input
Voltage
(VAC)
Output
Quantity
Output
Voltage
(VDC)
U:Universal
S:Single
Medical
Application
A: Open type
U: U chassis type
85 ~ 264
05: 5
7P5: 7.5
E: Enclosed type
09: 9
D: Din rail type
12: 12
Protection
Type
No suffix: CLASS I
B: CLASS II
15: 15
24: 24
28: 28
36: 36
48: 48
53: 53
1
www.PDUKE.com
2015/6/10
MAD65
TECHNICAL SPECIFICATION All specifications are typical at 230VAC input, full load and 25
Model
Number
otherwise noted
Input Range
Output Voltage
Output Current
@Convection cooled
60℃ Ta
Max.
Output
Power
Input Power
@ No Load
Efficiency
VAC
VDC
A
W
W
%
85 ~ 264
5
10
50
0.11
90
85 ~ 264
7.5
8.67
65
0.11
90
85 ~ 264
9
7.23
65
0.11
91
85 ~ 264
12
5.42
65
0.11
92.5
85 ~ 264
15
4.34
65
0.11
93.5
85 ~ 264
24
2.71
65
0.11
93.5
85 ~ 264
24
2.71
65
0.11
92
85 ~ 264
28
2.33
65
0.11
93.5
85 ~ 264
28
2.33
65
0.11
91.5
85 ~ 264
36
1.81
65
0.11
92.5
85 ~ 264
48
1.36
65
0.11
93
85 ~ 264
53
1.24
65
0.11
92.5
MAD65US05
MUD65US05
MED65US05
MDD65US05
MAD65US7P5
MUD65US7P5
MED65US7P5
MDD65US7P5
MAD65US09
MUD65US09
MED65US09
MDD65US09
MAD65US12
MUD65US12
MED65US12
MDD65US12
MAD65US15
MUD65US15
MED65US15
MDD65US15
MAD65US24
MUD65US24
MED65US24
MDD65US24
MAD65US241
MUD65US241
MED65US241
MDD65US241
MAD65US28
MUD65US28
MED65US28
MDD65US28
MAD65US281
MUD65US281
MED65US281
MDD65US281
MAD65US36
MUD65US36
MED65US36
MDD65US36
MAD65US48
MUD65US48
MED65US48
MDD65US48
MAD65US53
MUD65US53
MED65US53
MDD65US53
2
www.PDUKE.com
2015/6/10
MAD65
INPUT SPECIFICATIONS
Parameter
Operating input voltage range
Input frequency
Input current
No load input power
Leakage current
Start up time
Rise time
Hold up time
Input inrush current
Input protection
Conditions
Typ.
85
120
47
Max.
Unit
264
370
63
1.6
0.9
VAC
VDC
Hz
0.11
75
1000
20
16
115VAC and Full Load
230VAC
Internal fuse in line and neutral
OUTPUT SPECIFICATIONS
Parameter
Output power
Initial set voltage accuracy
Line regulation
Load regulation
Min.
AC input
DC input
AC input
100VAC and Full Load
240VAC and Full Load
230VAC
264VAC
60
T3.15A/250VAC
Conditions
Min.
230VAC and Full Load
Low Line to High Line at Full Load
No Load to Full Load
Typ.
A
Watts
µA
ms
ms
ms
A
Max.
Unit
Watts
%
%
5Vout
Others
-1.0
-0.2
-0.7
-0.5
65
+1.0
+0.2
+0.7
+0.5
5Vout
Others
53Vout
Others
-0.6
-0.4
-20
-10
+0.6
+0.4
+10
+10
%
10% Load to 90% Load
Voltage adjustability
Minimum load
Ripple and noise
Single output
Measured by 20MHz bandwidth
With a 10µF/25V 1206 X7R MLCC
With a 1µF/50V 1206 X7R MLCC
With a 0.1µF/100V 1206 X7R MLCC
Temperature coefficient
Transient response
Over voltage protection
Over load protection
Short circuit protection
Load step form 50 ~ 75% change at 2.5A/µs
5Vout, 7.5Vout, 9Vout
12Vout, 15Vout
24Vout, 28Vout, 36Vout
48Vout, 53Vout
Peak deviation
Recovery time
% of Vout(nom); Latch mode
% of Iout rated; Hiccup mode
GENERAL SPECIFICATIONS
Parameter
Conditions
Isolation voltage
1 minute (2MOPP insulation)
Isolation resistance
Switching frequency
500VDC
230VAC
4000
2500
0.1
Safety approvals
MTBF
MAD
MUD
MED
MDD
MIL-HDBK-217F, Full load
ENVIRONMENTAL SPECIFICATIONS
Parameter
Operating ambient temperature
Storage temperature range
Operating altitude
Shock
Vibration
Relative humidity
3
Conditions
Natural convection
Min.
With derating
Non-condensing
www.PDUKE.com
%
75
mVp-p
mVp-p
mVp-p
-0.02
+0.02
%/
3
% Vout
600
µs
125
140
%
145
%
Continuous, automatics recovery
5Vout
7.5Vout
9Vout
Others
Weight
0
75
150
Min.
Input to Output
Input (Output) to F.G.
%
-40
-40
Typ.
Max.
Unit
VAC
GΩ
60
80
kHz
70
120
ANSI/AAMI ES60601-1
EN60601-1
IEC60601-1
117g (4.13oz)
157g (5.54oz)
172g (6.07oz)
193g (6.81oz)
1.494 x 106 hrs
Typ.
Max.
Unit
+85
+85
5000
m
IEC60068-2-27
IEC60068-2-6
5% to 95% RH
2015/6/10
MAD65
EMC SPECIFICATIONS
Parameter
Conditions
EMI
EN55011, EN55022 and FCC Part 18
Harmonic currents
Voltage flicker
ESD
Radiated immunity
Fast transient
Surge
Conducted immunity
Power frequency magnetic field
Dip and interruptions
EN61000-3-2
EN61000-3-3
EN61000-4-2
EN61000-4-3
EN61000-4-4
EN61000-4-5
EN61000-4-6
EN61000-4-8
EN60601-1-2
EN61000-4-11
Level
Conducted
Radiated
Full Load
Air ± 8kV and Contact ± 6kV
20 V/m
± 2kV
DM ± 1kV and CM ± 2kV
20 Vr.m.s
10 A/m
230VAC 50Hz
30%
60%
>95%
>95%
100VAC 50Hz
30%
60%
>95%
>95%
500mS
100mS
10mS
5000mS
500mS
100mS
10mS
5000mS
Class B
Class B
Class A
Perf. Criteria A
Perf. Criteria A
Perf. Criteria A
Perf. Criteria A
Perf. Criteria A
Perf. Criteria A
Perf. Criteria A
Perf. Criteria A
Perf. Criteria A
Perf. Criteria B
Perf. Criteria A
Perf. Criteria B
Perf. Criteria A
Perf. Criteria B
CHARACTERISTIC CURVE
4
Derating Curve vs. Ambient Temperature
M□D65USxx xx=7P5/9/281
Derating Curve vs. Ambient Temperature
M□D65USxx xx=5/12/241/36/48/53
Derating Curve vs. Ambient Temperature
M□D65USxx xx=15/24/28
Derating Curve vs. Input Voltage
M D65
Efficiency VS Output Load
MAD65US24
Efficiency VS Input Voltage
MAD65US24
www.PDUKE.com
2015/6/10
MAD65
MECHANICAL DRAWING
MAD
Open type
MED Enclosed type
MDD
Din rail type
MUD
U chassis type
1. All dimensions in inch (mm)
2. Tolerance : x.xx±0.02 (x.x±0.5) x.xxx±0.01 (x.xx±0.25)
3. M3×0.5 screw locked torque MAX 5Kgf.cm/0.49N.m
CONNECTORS CONNECTIONS
CON1 – Input Connector
Pin 1
Pin 3
CON2 – Output Connector
Line
Neutral
Mates with
JST housing : VHR-3N
JST crimp terminals : SVH-21T-P1.1
5
Pin 1,2
Pin 3,4
Mounting holes marked with
must be
connected to safety earth for CLASS I application
www.PDUKE.com
-Vout
+Vout
Mates with
JST housing : VHR-4N
JST crimp terminals : SVH-21T-P1.1
2015/6/10