MAD65 SERIES SINGLE -OUTPUT 2 X 3 Inch AC-DC POWER SUPPLIES UNIVERSAL INPUT RANGE UP TO 65Watts FEATURES APPLICATIONS • 0.11 WATT LOW STANDBY POWER CONSUMPTION • WIDE INPUT VOLTAGE RANGE 85 TO 264VAC, 47 TO 63HZ • BUILT-IN CLASS B EMI FILTER • OUTPUT VOLTAGE ADJUSTABLE (SINGLE OUTPUT ONLY) • 4000VAC INPUT TO OUTPUT 2MOPP INSULATION • PROTECTION TYPE CLASS I AND CLASS II • LOW LEAKAGE CURRENT UNDER 75µA • OPERATING ALTITUDE 5000M • 5 YEAR WARRANTY • ANSI/AAMI ES60601-1, EN60601-1, & IEC60601-1 3rd EDITION SAFETY APPROVALS • CE MARKED • COMPLIANT TO RoHS II & REACH 4000VAC ISOLATION OCP SCP OVP • MEDICAL EQUIPMENT • WIRELESS NETWORK • TELECOM/DATACOM • INDUSTRY CONTROL SYSTEM • MEASUREMENT EQUIPMENT • SEMICONDUCTOR EQUIPMENT LOW STANDBY POWER PART NUMBER STRUCTURE M A D 65 U S 12 Application Package Code Dimension Code Output Power (W) Input Voltage (VAC) Output Quantity Output Voltage (VDC) U:Universal S:Single Medical Application A: Open type U: U chassis type 85 ~ 264 05: 5 7P5: 7.5 E: Enclosed type 09: 9 D: Din rail type 12: 12 Protection Type No suffix: CLASS I B: CLASS II 15: 15 24: 24 28: 28 36: 36 48: 48 53: 53 1 www.PDUKE.com 2015/6/10 MAD65 TECHNICAL SPECIFICATION All specifications are typical at 230VAC input, full load and 25 Model Number otherwise noted Input Range Output Voltage Output Current @Convection cooled 60℃ Ta Max. Output Power Input Power @ No Load Efficiency VAC VDC A W W % 85 ~ 264 5 10 50 0.11 90 85 ~ 264 7.5 8.67 65 0.11 90 85 ~ 264 9 7.23 65 0.11 91 85 ~ 264 12 5.42 65 0.11 92.5 85 ~ 264 15 4.34 65 0.11 93.5 85 ~ 264 24 2.71 65 0.11 93.5 85 ~ 264 24 2.71 65 0.11 92 85 ~ 264 28 2.33 65 0.11 93.5 85 ~ 264 28 2.33 65 0.11 91.5 85 ~ 264 36 1.81 65 0.11 92.5 85 ~ 264 48 1.36 65 0.11 93 85 ~ 264 53 1.24 65 0.11 92.5 MAD65US05 MUD65US05 MED65US05 MDD65US05 MAD65US7P5 MUD65US7P5 MED65US7P5 MDD65US7P5 MAD65US09 MUD65US09 MED65US09 MDD65US09 MAD65US12 MUD65US12 MED65US12 MDD65US12 MAD65US15 MUD65US15 MED65US15 MDD65US15 MAD65US24 MUD65US24 MED65US24 MDD65US24 MAD65US241 MUD65US241 MED65US241 MDD65US241 MAD65US28 MUD65US28 MED65US28 MDD65US28 MAD65US281 MUD65US281 MED65US281 MDD65US281 MAD65US36 MUD65US36 MED65US36 MDD65US36 MAD65US48 MUD65US48 MED65US48 MDD65US48 MAD65US53 MUD65US53 MED65US53 MDD65US53 2 www.PDUKE.com 2015/6/10 MAD65 INPUT SPECIFICATIONS Parameter Operating input voltage range Input frequency Input current No load input power Leakage current Start up time Rise time Hold up time Input inrush current Input protection Conditions Typ. 85 120 47 Max. Unit 264 370 63 1.6 0.9 VAC VDC Hz 0.11 75 1000 20 16 115VAC and Full Load 230VAC Internal fuse in line and neutral OUTPUT SPECIFICATIONS Parameter Output power Initial set voltage accuracy Line regulation Load regulation Min. AC input DC input AC input 100VAC and Full Load 240VAC and Full Load 230VAC 264VAC 60 T3.15A/250VAC Conditions Min. 230VAC and Full Load Low Line to High Line at Full Load No Load to Full Load Typ. A Watts µA ms ms ms A Max. Unit Watts % % 5Vout Others -1.0 -0.2 -0.7 -0.5 65 +1.0 +0.2 +0.7 +0.5 5Vout Others 53Vout Others -0.6 -0.4 -20 -10 +0.6 +0.4 +10 +10 % 10% Load to 90% Load Voltage adjustability Minimum load Ripple and noise Single output Measured by 20MHz bandwidth With a 10µF/25V 1206 X7R MLCC With a 1µF/50V 1206 X7R MLCC With a 0.1µF/100V 1206 X7R MLCC Temperature coefficient Transient response Over voltage protection Over load protection Short circuit protection Load step form 50 ~ 75% change at 2.5A/µs 5Vout, 7.5Vout, 9Vout 12Vout, 15Vout 24Vout, 28Vout, 36Vout 48Vout, 53Vout Peak deviation Recovery time % of Vout(nom); Latch mode % of Iout rated; Hiccup mode GENERAL SPECIFICATIONS Parameter Conditions Isolation voltage 1 minute (2MOPP insulation) Isolation resistance Switching frequency 500VDC 230VAC 4000 2500 0.1 Safety approvals MTBF MAD MUD MED MDD MIL-HDBK-217F, Full load ENVIRONMENTAL SPECIFICATIONS Parameter Operating ambient temperature Storage temperature range Operating altitude Shock Vibration Relative humidity 3 Conditions Natural convection Min. With derating Non-condensing www.PDUKE.com % 75 mVp-p mVp-p mVp-p -0.02 +0.02 %/ 3 % Vout 600 µs 125 140 % 145 % Continuous, automatics recovery 5Vout 7.5Vout 9Vout Others Weight 0 75 150 Min. Input to Output Input (Output) to F.G. % -40 -40 Typ. Max. Unit VAC GΩ 60 80 kHz 70 120 ANSI/AAMI ES60601-1 EN60601-1 IEC60601-1 117g (4.13oz) 157g (5.54oz) 172g (6.07oz) 193g (6.81oz) 1.494 x 106 hrs Typ. Max. Unit +85 +85 5000 m IEC60068-2-27 IEC60068-2-6 5% to 95% RH 2015/6/10 MAD65 EMC SPECIFICATIONS Parameter Conditions EMI EN55011, EN55022 and FCC Part 18 Harmonic currents Voltage flicker ESD Radiated immunity Fast transient Surge Conducted immunity Power frequency magnetic field Dip and interruptions EN61000-3-2 EN61000-3-3 EN61000-4-2 EN61000-4-3 EN61000-4-4 EN61000-4-5 EN61000-4-6 EN61000-4-8 EN60601-1-2 EN61000-4-11 Level Conducted Radiated Full Load Air ± 8kV and Contact ± 6kV 20 V/m ± 2kV DM ± 1kV and CM ± 2kV 20 Vr.m.s 10 A/m 230VAC 50Hz 30% 60% >95% >95% 100VAC 50Hz 30% 60% >95% >95% 500mS 100mS 10mS 5000mS 500mS 100mS 10mS 5000mS Class B Class B Class A Perf. Criteria A Perf. Criteria A Perf. Criteria A Perf. Criteria A Perf. Criteria A Perf. Criteria A Perf. Criteria A Perf. Criteria A Perf. Criteria A Perf. Criteria B Perf. Criteria A Perf. Criteria B Perf. Criteria A Perf. Criteria B CHARACTERISTIC CURVE 4 Derating Curve vs. Ambient Temperature M□D65USxx xx=7P5/9/281 Derating Curve vs. Ambient Temperature M□D65USxx xx=5/12/241/36/48/53 Derating Curve vs. Ambient Temperature M□D65USxx xx=15/24/28 Derating Curve vs. Input Voltage M D65 Efficiency VS Output Load MAD65US24 Efficiency VS Input Voltage MAD65US24 www.PDUKE.com 2015/6/10 MAD65 MECHANICAL DRAWING MAD Open type MED Enclosed type MDD Din rail type MUD U chassis type 1. All dimensions in inch (mm) 2. Tolerance : x.xx±0.02 (x.x±0.5) x.xxx±0.01 (x.xx±0.25) 3. M3×0.5 screw locked torque MAX 5Kgf.cm/0.49N.m CONNECTORS CONNECTIONS CON1 – Input Connector Pin 1 Pin 3 CON2 – Output Connector Line Neutral Mates with JST housing : VHR-3N JST crimp terminals : SVH-21T-P1.1 5 Pin 1,2 Pin 3,4 Mounting holes marked with must be connected to safety earth for CLASS I application www.PDUKE.com -Vout +Vout Mates with JST housing : VHR-4N JST crimp terminals : SVH-21T-P1.1 2015/6/10