2 X 3 Inch AC-DC POWER SUPPLIES
UNIVERSAL INPUT RANGE
UP TO 100Watts
FEATURES
APPLICATIONS
• LOW STANDBY POWER CONSUMPTION UNDER 0.3 WATT
• WIDE INPUT VOLTAGE RANGE 85 TO 264VAC, 47 TO 63HZ
• ACTIVE POWER FACTOR CORRECTION
• BUILT-IN EMI FILTER
• OUTPUT VOLTAGE ADJUSTABLE
• OPEN FRAME DIMENSIONS 2.00 X 3.00 X 1.16 INCH
• 3000VAC INPUT TO OUTPUT REINFORCED INSULATION
• PROTECTION TYPE CLASS I AND CLASS II
• LOW LEAKAGE CURRENT UNDER 300µA
• OPERATING ALTITUDE 5000M
• 3 YEAR WARRANTY
• UL60950-1, EN60950-1, & IEC60950-1 SAFETY APPROVALS
• CE MARKED
• COMPLIANT TO RoHS II & REACH
3000VAC
ISOLATION
OCP
SCP
OVP
• WIRELESS NETWORK
• TELECOM/DATACOM
• INDUSTRY CONTROL SYSTEM
• MEASUREMENT EQUIPMENT
• SEMICONDUCTOR EQUIPMENT
LOW
STANDBY
POWER
PART NUMBER STRUCTURE
T
A
D
100
U
S
12
Application
Package
Code
Dimension
Code
Output
Power
(W)
Input
Voltage
(VAC)
Output
Quantity
Output
Voltage
(VDC)
U:Universal
S:Single
12: 12V
No suffix: CLASS I
15: 15V
B: CLASS II
Industry
Application
A: Open type
U: U chassis type
85 ~ 264VAC
E: Enclosed type
24: 24V
D: Din rail type
28: 28V
Protection
Type
36: 36V
48: 48V
1
www.PDUKE.com
2015/3/16
TAD100
TECHNICAL SPECIFICATION All specifications are typical at 230VAC input, full load and 25
otherwise noted
Input
Range
Output
Voltage
Output Current
Natural convection
Input Power
No Load
Efficiency
VAC
VDC
A
W
%
85 ~ 264
12
8.34
0.3
91
85 ~ 264
15
6.67
0.3
92
85 ~ 264
24
4.17
0.3
92
85 ~ 264
28
3.58
0.3
92
85 ~ 264
36
2.78
0.3
91
85 ~ 264
48
2.09
0.3
91
Model
Number
TAD100US12
TUD100US12
TED100US12
TDD100US12
TAD100US15
TUD100US15
TED100US15
TDD100US15
TAD100US24
TUD100US24
TED100US24
TDD100US24
TAD100US28
TUD100US28
TED100US28
TDD100US28
TAD100US36
TUD100US36
TED100US36
TDD100US36
TAD100US48
TUD100US48
TED100US48
TDD100US48
INPUT SPECIFICATIONS
Parameter
Operating input voltage range
Input frequency
Input current
No load input power
Leakage current
Power Factor
Start up time
Rise time
Hold up time
Input inrush current
Input protection
2
Conditions
AC input
DC input
AC input
115VAC and Full Load
230VAC and Full Load
230VAC
264VAC
Min.
Typ.
85
120
47
Max.
Unit
264
370
63
1.15
0.55
0.3
300
VAC
VDC
Hz
A
Watts
µA
0.95
1000
20
115VAC and Full Load
230VAC
Internal fuse
22
100
T3.15A/250VAC
www.PDUKE.com
ms
ms
ms
A
2015/3/16
TAD100
OUTPUT SPECIFICATIONS
Parameter
Output power
Initial set voltage accuracy
Line regulation
Load regulation
Voltage adjustability
Minimum load
Ripple and noise
Temperature coefficient
Transient response
Over voltage protection
Over load protection
Short circuit protection
Conditions
230VAC and Full Load
Low Line to High Line at Full Load
No Load to Full Load
10% Load to 90% Load
Peak deviation
Recovery time
Load step form 50 ~ 75% change at 2.5A/µs
% of Vout(nom); Latch mode
% of Iout rated; Hiccup mode
Conditions
Isolation resistance
Switching frequency
Safety approvals
500VDC
Max.
Unit
100
+1.0
+0.2
+0.5
+0.4
+10
Watts
%
%
120
150
160
180
190
340
Typ.
3000
1500
0.1
ENVIRONMENTAL SPECIFICATIONS
Parameter
, Full load
Conditions
Natural convection and Full load (with derating)
-40 start up : 80% Load,max. @ Vin > 100VAC
-40 start up : 100% Load,max. @ Vin > 200VAC
Non-condensing
www.PDUKE.com
mVp-p
Min.
Max.
Unit
VAC
TAD
TUD
TED
TDD
MIL-HDBK-217F Ta=25
%
%
%/
% Vout
µs
500
115
135
%
115
150
%
Continuous, automatics recovery
Min.
Input to Output
Input (Output) to F.G.
%
+0.02
3
60
Weight
3
12Vout
15Vout
24Vout
28Vout
36Vout
48Vout
-0.02
1 minute (Reinforced insulation)
Storage temperature range
Operating altitude
Thermal shock
Shock
Vibration
Relative humidity
-1.0
-0.2
-0.5
-0.4
-10
Measured by 20MHz bandwidth
With a 10µF/25V 1206 X7R MLCC
With a 10µF/25V 1206 X7R MLCC
With a 1µF/50V 1206 X7R MLCC
With a 1µF/50V 1206 X7R MLCC
With a 1µF/50V 1206 X7R MLCC
With a 0.1µF/100V 1206 X7R MLCC
Isolation voltage
Operating ambient temperature
Typ.
0
GENERAL SPECIFICATIONS
Parameter
MTBF
Min.
Typ.
GΩ
kHz
UL60950-1
EN60950-1
IEC60950-1
156g (5.50oz)
194g (6.84oz)
210g (7.41oz)
232g (8.18oz)
7.903 x 105 hrs
Max.
Unit
-40
+85
-40
+85
5000
m
MIL-STD-810F
IEC68-2-27
IEC68-2-6
5% to 95% RH
2015/3/16
TAD100
EMC SPECIFICATIONS
Parameter
Conditions
EMI
EN55011, EN55022 and FCC Part 15
Harmonic currents
Voltage flicker
ESD
Radiated immunity
Fast transient
Surge
Conducted immunity
Power frequency magnetic field
Dip and interruptions
EN61000-3-2
EN61000-3-3
EN61000-4-2
EN61000-4-3
EN61000-4-4
EN61000-4-5
EN61000-4-6
EN61000-4-8
EN61000-4-11 and EN55024
Level
Conducted
Radiated
Full Load
Class B
Class A
Class A and D
Air ± 8kV and Contact ± 6kV
20 V/m
± 2kV
DM ± 1kV and CM ± 2kV
20 Vr.m.s
10 A/m
Perf. Criteria A
Perf. Criteria A
Perf. Criteria A
Perf. Criteria A
Perf. Criteria A
Perf. Criteria A
CHARACTERISTIC CURVE
Derating Curve vs. Ambient Temperature
TED100 & TDD100
Derating Curve vs. Ambient Temperature
TAD100 & TUD100
Derating Curve vs. Input Voltage
T D100
Efficiency vs. Output Load
T D100US24
4
Efficiency vs. Input Voltage
T D100US24
www.PDUKE.com
2015/3/16
TAD100
MECHANICAL DRAWING
TAD
Open type
TED Enclosed type
TDD
Din rail type
TUD
U chassis type
1. All dimensions in inch (mm)
2. Tolerance : x.xx±0.02 (x.x±0.5) x.xxx±0.01 (x.xx±0.25)
3. M3×0.5 screw locked torque MAX 5Kgf.cm/0.49N.m
CONNECTORS CONNECTIONS
CON1 – Input Connector
Pin 1
Pin 3
CON2 – Output Connector
Line
Neutral
Mates with
JST housing : VHR-3N
JST crimp terminals : SVH-21T-P1.1
5
Pin 1,2
Pin 3,4
Mounting holes marked with
must be
connected to safety earth for CLASS I application
www.PDUKE.com
-Vout
+Vout
Mates with
JST housing : VHR-4N
JST crimp terminals : SVH-21T-P1.1
2015/3/16