DEVICE SPECIFICATIONS NI 6581/6581B Specifications 100 MHz Single-Ended High-Speed Digital I/O Adapter Module This document lists specifications for the NI 6581/NI 6581B adapter module. Pair these specifications with the specifications listed in your NI FlexRIO FPGA specifications document. For more information about safety and electromagnetic compatibility, refer to the Read Me First: Safety and Electromagnetic Compatibility document included in your hardware kit or available at ni.com/manuals. Caution To avoid permanent damage to the NI 6581/NI 6581B, disconnect all signals connected to the NI 6581/NI 6581B before powering down the module, and only connect signals after the module has been powered on by the NI FlexRIO FPGA module. Note All numeric specifications are typical unless otherwise noted. All graphs illustrate the performance of a representative module. The NI 6581B is compatible with all NI FlexRIO FPGA modules. The NI 6581 variant is compatible with the NI PXI-795xR and NI PXIe-796xR FPGA modules only. Specifications are subject to change without notice. For the most recent device specifications, visit ni.com/manuals. Contents How to Use Your NI FlexRIO Documentation Set...................................................................2 Channel Specifications per Connector...................................................................................... 3 Generation Voltage Levels................................................................................................ 4 Acquisition Voltage Levels............................................................................................... 4 P0.<0..7>, P1.<0..7>, P2.<0..7>, and PFI<1..3>.............................................................. 5 CLOCK OUT.................................................................................................................... 5 GLOBAL CLOCK <0..1>................................................................................................ 5 Front Panel and Connector Pinouts...........................................................................................5 Power........................................................................................................................................ 8 Physical..................................................................................................................................... 9 Environment..............................................................................................................................9 Operating Environment.....................................................................................................9 Storage Environment.........................................................................................................9 Shock and Vibration..................................................................................................................9 Compliance and Certifications................................................................................................10 Safety.............................................................................................................................. 10 Electromagnetic Compatibility....................................................................................... 10 CE Compliance .............................................................................................................. 10 Online Product Certification........................................................................................... 11 Environmental Management........................................................................................... 11 How to Use Your NI FlexRIO Documentation Set Refer to the following flowchart for information about how to use FlexRIO documentation. Figure 1. How to Use Your NI FlexRIO Documentation Set. Getting Started Guide for your FPGA module INSTALL Hardware and Software Specifications document for your FPGA module Getting Started Guide for your adapter module CONNECT Signals and LearnAbout Your AdapterModule Specifications document for your adapter module PROGRAM Your NI FlexRIO System in LabVIEW FPGA Module Are You New to LabVIEW FPGA Module? LEARN About LabVIEW FPGA Module Yes No No LabVIEW FPGA Module Help NI FlexRIO Help LabVIEW Examples Table 1. NI FlexRIO Documentation Locations and Descriptions Document Location Description Getting started guide for Available from the Start menu Contains installation instructions your FPGA module and at ni.com/manuals. for your NI FlexRIO system. Specifications document Available from the Start menu Contains specifications for your for your FPGA module and at ni.com/manuals. FPGA module. Getting started guide for Available from the Start menu Contains signal information, your adapter module and at ni.com/manuals. examples, and CLIP details for your adapter module. 2 | ni.com | NI 6581/6581B Specifications Table 1. NI FlexRIO Documentation Locations and Descriptions (Continued) Document Location Description Specifications document Available from the Start menu Contains specifications for your for your adapter module and at ni.com/manuals. adapter module. LabVIEW FPGA Module Embedded in LabVIEW Help Help and at ni.com/manuals. Contains information about the basic functionality of the LabVIEW FPGA Module. NI FlexRIO Help Available from the Start menu Contains information about the and at ni.com/manuals. FPGA module, adapter module, and CLIP configuration information. LabVIEW Examples Available in NI Example Finder. In LabVIEW, click Help»Find Examples» Hardware Input and Output»FlexRIO. Contains examples of how to run FPGA VIs and Host VIs on your device. IPNet ni.com/ipnet Contains LabVIEW FPGA functions and intellectual property to share. NI FlexRIO product page ni.com/flexrio Contains product information and data sheets for NI FlexRIO devices. Channel Specifications per Connector Number of DDC connectors ............................................................................ 2, DDCA and DDCB Number of digital I/O connectors ............................................................................ 54 total (48 data, 6 PFI), 27 per DDC connector ............................................................................ Direction control of data channels Configurable per 8-bit port (P0.<0..7>, P1.<0..7>, P2.<0..7>) Direction control of PFI <1..3> ............................................................................ All input or output, per port per connector Note Digital I/O signals, P0.<0..7>, P1.<0..7>, P2.<0..7>, and PFI <1..3>, appear on both connectors, DDCA and DDCB. NI 6581/6581B Specifications | © National Instruments | 3 Generation Voltage Levels Table 2. P0.<0..7>, P1.<0..7>, P2.<0..7>, PFI <1..3>, and CLOCK OUT Voltage Low Voltage Levels Guaranteed High Voltage Levels Guaranteed2 Typical Typical 5.0 V3 0.55 V 0V 3.8 V 5.0 V 3.3 V 0.55 V 0V 2.4 V 3.3 V 2.5 V 0.30 V 0V 1.9 V 2.5 V 1.8 V 0.45 V 0V 1.2 V 1.8 V Note Each connector can be referenced to the external or internal power supply. Acquisition Voltage Levels Table 3. P0.<0..7>, P1.<0..7>, P2.<0..7>, PFI <1..3>, and GLOBAL CLOCK <0..1> Guaranteed Low Voltage Threshold4 Voltage Guaranteed High Voltage Threshold5 5.0 V6 1.5 V 3.5 V 3.3 V 0.8 V 2.0 V 2.5 V 0.7 V 1.7 V 1.8 V 0.6 V 1.2 V Note Each connector can be referenced to an external or internal power supply. Note The I/O buffer performance on the NI 6581 is similar to the buffer performance specifications for the TI SN74LVC8T245 transceiver. The performance is correlated to supply voltage. I/O timing performance degrades as supply voltage decreases. 1 2 3 4 5 6 4 | Voltage levels guaranteed by design through the digital buffer specifications. Voltage levels guaranteed by design through the digital buffer specifications. 5.0 V available only through an external power supply. Voltage levels guaranteed by design through the digital buffer specification. Voltage levels guaranteed by design through the digital buffer specification. 5.0 V only available through an external power supply. ni.com | NI 6581/6581B Specifications P0.<0..7>, P1.<0..7>, P2.<0..7>, and PFI<1..3> Output ............................................................................ impedance (nominal) 50 Ω Maximum input leakage ............................................................................ ±6 µA Characteristic impedance ............................................................................ 50 Ω traces Power-on state ............................................................................ Drivers disabled Absolute maximum input range ............................................................................ -0.5 to 6.5 V CLOCK OUT ............................................................................ Output impedance (nominal) 50 Ω series Maximum output voltage range ............................................................................ 1.8 V to 5.5 V, output only Maximum toggle rate ............................................................................ 100 MHz at ≥3.3 V GLOBAL CLOCK <0..1> ............................................................................ Direction Input into device7 Maximum ............................................................................ input leakage ±4 µA Characteristic impedance ............................................................................ 50 Ω traces Power-on state ............................................................................ Drivers disabled Absolute maximum input range ............................................................................ -0.5 V to 6.5 V Maximum toggle rate ............................................................................ 100 MHz at ≥3.3 V Front Panel and Connector Pinouts The following figure shows the digital data connector (DDC) pin assignments for the NI 6581/6581B. 7 The clock is connected to NI FlexRIO FPGA module global clock inputs. NI 6581/6581B Specifications | © National Instruments | 5 Figure 2. NI 6581/6581B Connector Pin Assignments DDCB DDCA GND GLOBAL CLOCK 0 GND P0.0 PFI 2 P0.2 GND P0.4 No Connect GND P1.0 GND P1.2 GND P1.4 GND P1.6 P2.0 GND P2.2 GND P2.4 GND P2.6 GND RESERVED GND RESERVED GND RESERVED GND RESERVED GND GND CLOCK OUT GLOBAL CLOCK 1 GND GND P0.1 P0.0 PFI 3 PFI 2 P0.3 P0.2 GND GND P0.5 P0.4 PFI 1 No Connect P0.7 P0.6 GND P1.1 GND GND P1.0 GND P1.3 P1.2 GND GND P1.5 P1.4 GND GND P1.7 P1.6 GND GND DDCB: PORTS 0-2 GND 34 33 32 31 30 29 28 27 26 25 24 23 22 21 20 19 18 17 16 15 14 13 12 11 10 9 8 7 6 5 4 3 2 1 DDCA: PORTS 0-2 P0.6 68 67 66 65 64 63 62 61 60 59 58 57 56 55 54 53 52 51 50 49 48 47 46 45 44 43 42 41 40 39 38 37 36 35 P2.1 GND P2.3 P2.0 GND P2.2 GND GND P2.5 P2.4 GND GND P2.7 P2.6 GND GND RESERVED RESERVED GND GND RESERVED RESERVED GND GND RESERVED RESERVED GND GND RESERVED RESERVED 68 67 66 65 64 63 62 61 60 59 58 57 56 55 54 53 52 51 50 49 48 47 46 45 44 43 42 41 40 39 38 37 36 35 34 33 32 31 30 29 28 27 26 25 24 23 22 21 20 19 18 17 16 15 14 13 12 11 10 9 8 7 6 5 4 3 2 1 GND CLOCK OUT GND P0.1 PFI 3 P0.3 GND P0.5 PFI 1 P0.7 GND P1.1 GND P1.3 GND P1.5 GND P1.7 GND P2.1 GND P2.3 GND P2.5 GND P2.7 GND RESERVED GND RESERVED GND RESERVED GND RESERVED GND +VA +VB Note Connections that exceed any of the maximum ratings of input or output signals on the NI 6581/6581B can damage the device and the chassis. NI is not liable for any damage resulting from such signal connections. 6 | ni.com | NI 6581/6581B Specifications Table 4. NI 6581 DDC Connector Pins Signal Name Pin(s) Signal Type Control Signal Description GLOBAL CLOCK 0 67 on DDCA Input terminal for the external Sample Clock source, which can be used for dynamic acquisition. GLOBAL CLOCK 1 67 on DDCB P0.<0..7> 25, 27, 29, 31, 59, 61, Data/Control Bidirectional Port 0 digital I/O 63, 65 data channels 0 through 7. P1.<0..7> 17, 19, 21, 23, 51, 53, Data/Control Bidirectional Port 1 digital I/O 55, 57 data channels 0 through 7. P0.<0..7> 9, 11, 13, 15, 43, 45, 47, 49 Data/Control Bidirectional Port 2 digital I/O data channels 0 through 7. CLOCK OUT 33 Control PFI <1..3> 26, 30, 64 Control/Data Bidirectional digital I/O channels 1 through 3. GND 2, 4, 6, 8, 10, 12, 14, Ground 16, 18, 20, 22, 24, 28, 32, 34, 36, 38, 40, 42, 44, 46, 48, 50, 52, 54, 56, 58, 62, 66 Ground reference for signals. RESERVED 1, 3, 5, 7, 35, 37, 39, 41 N/A These terminals are reserved for future use. Do not connect to these pins. No Connect 60 N/A Do not connect to this pin. Output terminal for the exported Sample Clock. The following table contains external power connector terminal information for the NI 6581. Table 5. NI 6581 Power Connector Terminals External Power Terminal Name Terminal Description GND Ground reference for external power +VA External power terminal for DDCA connector. +VB External power terminal for DDCB connector. NI 6581/6581B Specifications | © National Instruments | 7 The following table lists the NI 6581/6581B power supply control signals and the corresponding NI FlexRIO FPGA module signals. Table 6. NI 6581/6581B Power Supply Control Signals and NI FlexRIO FPGA Module Signals NI 6581/6581B Supply Control Signal Name NI FlexRIO FPGA Module GPIO Out BANK0_SUPPLY_SELECT GPIO_32 BANK1_SUPPLY_SELECT GPIO_32_n PWR_SUPPLY_SEL_0 GPIO_65 PWR_SUPPLY_SEL_1 GPIO_65_n Power Internal power source Power requirements from the NI FlexRIO FGPA module ............................................................ +3.3 V 200 mA, maximum +12 V ............................................................ 250 mA, maximum External power source Voltage range .................................................................... 1.8 V to 5.5 V Current .................................................................... 0.7 A at 3.3 V driving a 1 k load, all channels toggling with a PRBS pattern at full rate Power dissipation VA power + VB power ............................................................ <5 W, maximum Capacitance on +VA and ............................................................ 50 µF per rail +VB Note With higher voltages, it is possible to exceed the power dissipation limit. Maximum DC drive strength .................................................................... 5.0 V 32 mA 3.3 V .................................................................... 24 mA 2.5 V .................................................................... 8 mA 1.8 V .................................................................... 4 mA Caution You must wait at least 10 ms after changing the power supply to allow the rails to settle to their new voltage before acquiring or generating data. 8 | ni.com | NI 6581/6581B Specifications Physical Dimensions ............................................................................12.9 cm × 2.0 cm × 12.1 cm (5.1 in. × 0.8 in. × 4.7 in.) Weight ............................................................................284 g (10 oz) Front panel connectors ............................................................................ Two 68-pin VHDCI connectors Spring-terminal wiring ............................................................................ 20 to 26 AWG copper conductor wire with 11 mm (0.43 in.) of insulation stripped from the end Environment ............................................................................ Maximum altitude 2,000 m (800 mbar) (at 25 °C ambient temperature) Pollution Degree ............................................................................ 2 Indoor use only. Operating Environment ............................................................................ Ambient temperature range 0 °C to 55 °C (Tested in accordance with IEC-60068-2-1 and IEC-60068-2-2.) Relative ............................................................................ humidity range 10% to 90%, noncondensing (Tested in accordance with IEC-60068-2-56.) Storage Environment Ambient ............................................................................ temperature range -20 °C to 70 °C (Tested in accordance with IEC-60068-2-1 and IEC-60068-2-2.) Relative humidity range ............................................................................ 5% to 95%, noncondensing (Tested in accordance with IEC-60068-2-56.) Shock and Vibration Operating ............................................................................ shock 30 g peak, half-sine, 11 ms pulse (Tested in accordance with IEC-60068-2-27. Meets MIL-PRF-28800F Class 2 limits.) NI 6581/6581B Specifications | © National Instruments | 9 Random vibration Operating .................................................................... 5 Hz to 500 Hz, 0.3 grms Nonoperating .................................................................... 5 Hz to 500 Hz, 2.4 grms (Tested in accordance with IEC-60068-2-64. Nonoperating test profile exceeds the requirements of MIL-PRF-28800F, Class 3.) Compliance and Certifications Safety This product is designed to meet the requirements of the following electrical equipment safety standards for measurement, control, and laboratory use: • IEC 61010-1, EN 61010-1 • UL 61010-1, CSA 61010-1 Note For UL and other safety certifications, refer to the product label or the Online Product Certification section. Electromagnetic Compatibility This product meets the requirements of the following EMC standards for electrical equipment for measurement, control, and laboratory use: • EN 61326-1 (IEC 61326-1): Class A emissions; Basic immunity • EN 55011 (CISPR 11): Group 1, Class A emissions • AS/NZS CISPR 11: Group 1, Class A emissions • FCC 47 CFR Part 15B: Class A emissions • ICES-001: Class A emissions Note In the United States (per FCC 47 CFR), Class A equipment is intended for use in commercial, light-industrial, and heavy-industrial locations. In Europe, Canada, Australia, and New Zealand (per CISPR 11), Class A equipment is intended for use only in heavy-industrial locations. Note Group 1 equipment (per CISPR 11) is any industrial, scientific, or medical equipment that does not intentionally generate radio frequency energy for the treatment of material or inspection/analysis purposes. Note For EMC declarations, certifications, and additional information, refer to the Online Product Certification section. CE Compliance This product meets the essential requirements of applicable European Directives, as follows: 10 | ni.com | NI 6581/6581B Specifications • • 2006/95/EC; Low-Voltage Directive (safety) 2004/108/EC; Electromagnetic Compatibility Directive (EMC) Online Product Certification To obtain product certifications and the DoC for this product, visit ni.com/certification, search by model number or product line, and click the appropriate link in the Certification column. Environmental Management NI is committed to designing and manufacturing products in an environmentally responsible manner. NI recognizes that eliminating certain hazardous substances from our products is beneficial to the environment and to NI customers. For additional environmental information, refer to the Minimize Our Environmental Impact web page at ni.com/environment. This page contains the environmental regulations and directives with which NI complies, as well as other environmental information not included in this document. Waste Electrical and Electronic Equipment (WEEE) EU Customers At the end of the product life cycle, all products must be sent to a WEEE recycling center. For more information about WEEE recycling centers, National Instruments WEEE initiatives, and compliance with WEEE Directive 2002/96/EC on Waste Electrical and Electronic Equipment, visit ni.com/environment/weee. 电子信息产品污染控制管理办法(中国 RoHS) 中国客户 National Instruments 符合中国电子信息产品中限制使用某些有害物 质指令(RoHS)。关于 National Instruments 中国 RoHS 合规性信息,请登录 ni.com/environment/rohs_china。(For information about China RoHS compliance, go to ni.com/environment/rohs_china.) NI 6581/6581B Specifications | © National Instruments | 11 Refer to the NI Trademarks and Logo Guidelines at ni.com/trademarks for information on National Instruments trademarks. Other product and company names mentioned herein are trademarks or trade names of their respective companies. For patents covering National Instruments products/technology, refer to the appropriate location: Help»Patents in your software, the patents.txt file on your media, or the National Instruments Patent Notice at ni.com/patents. You can find information about end-user license agreements (EULAs) and third-party legal notices in the readme file for your NI product. Refer to the Export Compliance Information at ni.com/legal/export-compliance for the National Instruments global trade compliance policy and how to obtain relevant HTS codes, ECCNs, and other import/export data. NI MAKES NO EXPRESS OR IMPLIED WARRANTIES AS TO THE ACCURACY OF THE INFORMATION CONTAINED HEREIN AND SHALL NOT BE LIABLE FOR ANY ERRORS. U.S. Government Customers: The data contained in this manual was developed at private expense and is subject to the applicable limited rights and restricted data rights as set forth in FAR 52.227-14, DFAR 252.227-7014, and DFAR 252.227-7015. © 2010—2014 National Instruments. All rights reserved. 372629C-01 Sep14