NI 5761R User Guide and Specifications

NI 5761R User Guide and Specifications
The NI 5761 is a 250 MS/s analog input adapter module designed to work in conjunction with your
NI FlexRIO™ FPGA module. This document contains signal information and specifications for the
NI 5761R, which is comprised of an NI FlexRIO FPGA module and the NI 5761. This document also
contains tutorial sections that demonstrate how to acquire data using a LabVIEW FPGA example VI
and how to create and run your own LabVIEW project with the NI 5761R.
Contents
Front Panel and Connector Pinouts ..................................................................................................... 2
Block Diagram..................................................................................................................................... 4
NI 5761 Component-Level Intellectual Property (CLIP) .................................................................... 5
Cables................................................................................................................................................... 6
Clocking............................................................................................................................................... 7
Using Your NI 5761R with a LabVIEW FPGA Example VI.............................................................. 7
Creating a LabVIEW Project and Run a VI on an FPGA Target ........................................................ 9
How to Use Your NI FlexRIO Documentation Set ............................................................................. 12
Specifications....................................................................................................................................... 13
Where to Go for Support ..................................................................................................................... 24
Note
Before configuring your NI 5761R, you must install the appropriate software and hardware.
Refer to the NI FlexRIO FPGA Module Installation Guide and Specifications for installation
instructions. Figure 1 shows an example of a properly connected NI FlexRIO device.
NI FlexRIO
Adapter Module
+
NI FlexRIO
FPGA Module
=
NI FlexRIO Device
Figure 1. NI FlexRIO Device
Front Panel and Connector Pinouts
Front Panel
Table 1 shows the front panel connector and signal descriptions for the NI 5761. Refer to the
Specifications section of this document for additional signal information.
Caution
To avoid permanent damage to the NI 5761, disconnect all signals connected to the NI 5761
before powering down the module, and only connect signals after the adapter module has been
powered on by the NI FlexRIO FPGA module.
Table 1. NI 5761 Front Panel Connectors
Device Front Panel
NI 5761
Connector
Signal Description
AUX I/O
Refer to Table 2 for the signal names and descriptions.
D<0..3>
LEDs for custom configuration.
CLK IN
Provides the NI 5761 with an external Sample clock or
Reference clock.
AUX I/O
TRIG
Trigger input channel.
CH 0
Analog input channels <0..3>.
CH 1
CH 2
D0 D1
D2 D3
CH 3
CLK IN TRIG
CH 0
CH 1
CH 2
CH 3
250 MS/s
Analog Input
NI 5761R User Guide and Specifications
2
ni.com
AUX I/O Connector
Table 2 shows the pins assignments for the AUX I/O connector on the NI 5761.
Table 2. NI 5761 AUX I/O Connector Pin Assignments
Micro-D Connector
Pin
Signal
Signal Description
1
AUXIO0
General-purpose digital input or output channels.
2
AUXIO1
3
AUXIO2
4
AUXIO3
5
AUXIO4
6
AUXIO5
7
AUXIO6
8
AUXIO7
9
GND
10
GND
11
GND
12
GND
13
GND
14
GND
15
GND
1
9
2
10
3
11
4
12
5
13
6
Ground.
14
7
15
8
Caution Connections that exceed any of the maximum ratings of any connector on the NI 5761R
can damage the device and the chassis. NI is not liable for any damage resulting from such signal
connections. For the maximum input and output ratings for each signal, refer to the Specifications
section of this document.
© National Instruments Corporation
3
NI 5761R User Guide and Specifications
Block Diagram
Figure 2 shows the NI 5761 block diagram and signal flow to and from the NI 5761 component-level intellectual
property (CLIP) by way of the adapter module and the corresponding NI 5761 CLIP in LabVIEW FPGA.
NI 5761 Adapter Module
AUX I/O
8
LabVIEW FPGA CLIP
8
FET
Buffer
8
8
D<0..3>
(LEDs)
4
Buffer
PFI Input
PFI Output
PFI Write Enable
PFI Connector
Enable
LED <0..3>
Trigger Input
Internal
Reference
Clock
CLK IN
Switch
Switch
Clock
Buffer
SPI Engine
Interfacing
with:
Clock
Synthesizer
TRIG
FET
Buffer
AD9512
ADS62P49
Switches
Analog FE
Switch
Sample Clock
AD9512
CH 0
IO Module Clock 0
(n = 1, Single Sample CLIP
n = 2, Multiple Sample CLIP)
Multiple
Sample CLIP
Analog
Front End
ADS62P49
CH 1
1/n
SPI Read
SPI Write
SPI Address
SPI Write Data
SPI Read Data
SPI Device Select
SPI Idle
Initialization Done
Reinitialize
Configuration Error
Sample Clock Select
Sample Clock Commit
Synthesizer Locked
Data
AI 0 Data N
Clock
AI 0 Data N–1
AI 1 Data N
Analog
Front End
AI 0
AI 1
AI 1 Data N–1
AI 2 Data N
ADC
Interface
AI 2
AI 2 Data N–1
AI 3 Data N
CH 2
Single
Sample CLIP
AI 3
AI 3 Data N–1
Analog
Front End
Data
ADS62P49
CH 3
Clock
Analog
Front End
IOModSyncClock
Figure 2. NI 5761 Connector Signals and NI 5761 CLIP Signal Block Diagram
NI 5761R User Guide and Specifications
4
ni.com
NI 5761 Component-Level Intellectual Property (CLIP)
The LabVIEW FPGA Module includes a feature for HDL IP integration called CLIP. NI FlexRIO
devices support two types of CLIP: user-defined and socketed.
•
User-defined CLIP allows users to insert HDL IP into an FPGA target, enabling VHDL code to
communicate directly with an FPGA VI.
•
Socketed CLIP provides the same IP integration functionality of the user-defined CLIP, but also
allows the CLIP to communicate directly with circuitry external to the FPGA. Adapter module
socketed CLIP allows your IP to communicate directly with both the FPGA VI and the external
adapter module connector interface.
Figure 3 shows the relationship between an FPGA VI and CLIP.
NI FlexRIO FPGA Module
FPGA
Adapter Module
CLIP Socket
LabVIEW
FPGA VI
User-Defined
CLIP
Socketed
CLIP
Socketed
CLIP
Socketed
CLIP
Fixed I/O
DRAM 1
CLIP Socket
Fixed I/O
DRAM 0
CLIP Socket
DRAM0
DRAM1
Fixed I/O
Adapter
Module
External
I/O Connector
User-Defined
CLIP
Figure 3. CLIP Relationship
© National Instruments Corporation
5
NI 5761R User Guide and Specifications
The NI 5761 ships with socketed CLIP items that are used to add module I/O to the LabVIEW project.
The NI 5761 ships with the following CLIP items:
•
NI 5761 Multiple Sample CLIP—Generates two samples per clock cycle at a clock rate that is
half the sample rate. The default sample rate is 250 MHz, which sets the default clock rate for this
CLIP at 125 MHz. You can set a lower sample rate by using an external Sample clock. This CLIP
provides access to four analog input channels, eight PFI lines, and an input clock selector that can
be configured to use one of the following settings:
–
Internal Sample clock
–
Internal Sample clock locked to an external Reference clock through the CLK IN connector
–
External Sample clock through the CLK IN connector
–
Internal Sample clock locked to an external Reference clock through IoModSyncClock
–
External Sample clock through IoModSyncClock
This CLIP also contains an engine to program the CLK chip and ADCs, either through predetermined
settings for an easier instrument setup or through a raw SPI address and data signals for a more advanced
setup. The NI 5761 Multiple Sample CLIP is the default CLIP.
•
NI 5761 Single Sample CLIP—Generates one sample per clock cycle at a default sample rate of
250 MHz. You can set a lower sample rate by using an external Sample clock. This CLIP provides
access to four analog input channels, eight PFI lines, and an input clock selector that can be
configured to use one of the following settings:
–
Internal Sample clock
–
Internal Sample clock locked to an external Reference clock through the CLK IN connector
–
External Sample clock through the CLK IN connector
–
Internal Sample clock locked to an external Reference clock through IoModSyncClock
–
External Sample clock through IoModSyncClock
This CLIP also contains an engine to program the CLK chip and ADCs, either through predetermined
settings for an easier instrument setup or through a raw SPI address and data signals for a more advanced
setup.
Refer to the NI FlexRIO Help in the LabVIEW Help for more information about NI FlexRIO CLIP items,
configuring the NI 5761 with a socketed CLIP, and a list of available socketed CLIP and provided
signals.
Cables
Use the NI CMD-to-CMD cable (NI part number 763194-01) or the NI CMD Single-ended to Pigtail
cable (NI part number 763191-01) to connect signals to your AUX I/O connector. Use any 50 Ω SMA
cable to connect signals to the other connectors on the front panel of your NI 5761. For more information
about connecting I/O signals on your device, refer to the Specifications section of this document.
NI 5761R User Guide and Specifications
6
ni.com
Clocking
The NI 5761 clocks control the sample rate and other timing functions on the device. Table 3 contains
information about the possible NI 5761 clock resources.
Table 3. NI 5761 Clock Sources
Clock
Frequency
Sample Clock
175 MHz to 250 MHz
Reference Clock
10 MHz
Source Options
•
Internal VCO locked to a Reference clock
•
External through the CLK IN connector
•
External through IoModSyncClock
•
Internal
•
External through the CLK IN connector
•
External through IoModSyncClock
Using Your NI 5761R with a LabVIEW FPGA Example VI
The NI FlexRIO Adapter Module Support software includes a variety of example projects to help get
you started creating your LabVIEW FPGA program. This section explains how to use an existing
LabVIEW FPGA example project to generate and acquire samples with the NI 5761R. This example
requires at least one SMA cable for connecting signals to your NI 5761R.
Note Examples available for your device are dependent on the device-specific minimum software
requirements. For more information about software requirements for your device, visit ni.com/
info and enter rdsoftwareversion as the Info Code to determine which minimum software
versions you need for your device.
Each NI 5761R example project includes the following components:
•
•
A LabVIEW FPGA VI that can be compiled and run embedded in FPGA hardware
A VI that runs in LabVIEW for Windows and interacts with the LabVIEW FPGA VI
Note
In NI application software, NI FlexRIO adapter modules are referred to as IO Modules.
Complete the following steps to run an example that acquires a waveform on CH 0 of the NI 5761.
1. Connect one end of an SMA cable to CH 0 on the front panel of the NI 5761 and the other end of
the cable to your device under test (DUT).
2.
Launch LabVIEW.
3.
In the Getting Started window, click Find Examples to display the NI Example Finder.
4.
In the NI Example Finder window, select Hardware Input and Output»FlexRIO»IO Modules»
NI 5761.
5.
Select NI 5761 - Getting Started.lvproj.
6.
In the Project Explorer window, open NI 5761 - Getting Started (Host).vi under My Computer.
The host VI opens. This VI uses the NI 7952R as the FPGA target by default. If you are using an
NI FlexRIO FPGA module other than the NI 7952R, complete the following steps to change to an
FPGA VI that supports your target.
a.
Select Window»Show Block Diagram to open the VI block diagram.
b.
On the block diagram, right-click the Open FPGA VI Reference (PXI-7952R) function and
select Configure Open FPGA VI Reference.
© National Instruments Corporation
7
NI 5761R User Guide and Specifications
7.
c.
In the Configure Open FPGA VI Reference dialog box, click the Browse Project button in
the Open VI section.
d.
In the Select VI dialog box that opens, expand the tree view for your device, select the VI
under your device and click OK.
e.
Click OK in the Configure Open FPGA VI Reference dialog box.
f.
Save the VI.
On the front panel, in the RIO Resource box, select an NI 5761R resource that corresponds with
the target configured in step 6.
8.
Select AI 0 in the AI Channel box.
9.
Set the Trigger Level (V) and the Record Size controls to the desired value.
10. In the Trigger Type box, you can select either Software Trigger or Data Edge. If you select
Software Trigger, the VI acquires data every time you click the Software Trigger button on the
front panel of the VI. If you select Data Edge, the VI acquires data every time an edge occurs.
11. Click the Run button to run the VI.
12. Click the Software Trigger button if you selected Software Trigger in the Trigger Type box. The
VI acquires data and displays the captured waveform on the Acquired Waveform graph as shown
in Figure 4.
13. Click STOP to stop the VI.
14. Close the VI.
Figure 4. NI 5761 - Getting Started (Host) VI Front Panel
NI 5761R User Guide and Specifications
8
ni.com
Creating a LabVIEW Project and Run a VI on an FPGA Target
This section explains how to setup your target and create an FPGA VI and host VI for data
communication. For more detailed information about acquiring data on your NI 5761R, refer to the
example VIs available on your NI FlexRIO Adapter Module Support software.
Creating a Project
1.
Launch LabVIEW, or if LabVIEW is already running, select File»New.
2.
In the New dialog box, select Project»Empty Project. Click OK. The new project opens in the
Project Explorer window.
3.
Save the project as 5761SampleAcq.lvproj.
Creating an FPGA Target VI
1.
In the Project Explorer window, right-click My Computer and select New»Targets and
Devices.
2.
In the Add Targets and Devices on My Computer dialog box, select the Existing Target or
Device option button and expand the FPGA Target. The target is displayed.
3.
Select your device and click OK. The target and target properties are loaded into the project tree.
4.
In the Project Explorer window, expand FPGA Target (RIOx, PXI-79xxR).
5.
Right-click the FPGA target and select New»FPGA Base Clock.
6.
In the Resource pull-down menu, select IO Module Clock 0.
7.
Enter 125 MHz in the Compile for single frequency control. Click OK.
8.
Right-click the FPGA target and select New»FPGA Base Clock again.
9.
In the Resource pull-down menu, select 200 MHz Clock. Click OK.
10. Right-click IO Module and select Properties. In the General category, you can see the available
CLIP for the NI 5761 in the Component Level IP pane. If the category information is dimmed,
select the Enable IO Module checkbox.
11. Select NI 5761 Multi Sample CLIP.
12. In the Clock Selections category, select 200 MHz Clock from the pull-down menu for Clk200.
Leave Clk40 configured as the Top-Level Clock. This step is necessary to compile the FPGA
Target VI correctly. Click OK.
Note Configuring these clocks is required for proper CLIP operation. Refer to the NI 5761 CLIP
topics in the NI FlexRIO Help for more information about configuring your clocks.
13. In the Project Explorer window, right-click the FPGA target and select New»VI. A blank VI
opens.
14. Select Window»Show Block Diagram to open the VI block diagram.
15. In the Project Explorer window, expand the IO Module (NI 5761 : NI 5761) tree view.
16. Select AI 0 Data N and AI 0 Data N-1 and drag them onto the block diagram.
17. Add a Timed Loop around the two nodes.
18. Wire an indicator to the output terminals of the IO Module\AI 0 Data N and IO Module\AI 0
Data N-1 nodes.
19. Wire an FPGA Clock Constant to the input node of the Timed Loop. Set this constant to
IO Module Clock 0.
© National Instruments Corporation
9
NI 5761R User Guide and Specifications
Your block diagram should now resemble the block diagram in Figure 5.
Figure 5. 5761SampleAcq (FPGA).vi Block Diagram
Tip
Click the Clean Up Diagram button on the toolbar to cleanly organize the VI block diagrams.
20. Save the VI as 5761SampleAcq (FPGA).vi.
21. Close the VI.
22. In the Project Explorer window under My Computer, expand the tree view for your device,
right-click 5761SampleAcq (FPGA).vi and select Compile to compile the files for your target.
The Generating Intermediate Files window opens and displays the compilation progress.
The LabVIEW FPGA Compile Server window opens and runs. The compilation takes several
minutes.
23. When the compilation completes, click the Stop Server button.
24. Click Close in the Successful Compile Report window.
25. Save and close the VI.
26. Save the project.
Creating a Host VI
1.
In the Project Explorer window, right-click My Computer and select New»VI. A blank VI opens.
Select Window»Show Block Diagram to open the VI block diagram.
2.
Add the Open FPGA VI Reference function, located on the FPGA Interface palette, to the block
diagram.
3.
Right-click the Open FPGA VI Reference function, labeled No Target, and select Configure
Open FPGA VI Reference.
4.
In the Configure Open FPGA VI Reference dialog box, select the VI option button.
5.
In the Select VI window that opens, select 5761SampleAcq (FPGA).vi under your device, and
click OK.
6.
Click OK in the Configure Open FPGA VI Reference dialog box. The new target name appears
under the Open FPGA VI Reference function in the block diagram.
7.
Add a While Loop to the block diagram.
8.
Right-click the stop condition inside the While Loop and select Create Control to create a
STOP control on the VI front panel.
9.
Add the Read/Write Control function, located on the FPGA Interface palette, inside the
While Loop.
10. Wire the FPGA VI Reference Out indicator of the Open FPGA VI Reference function to the
FPGA VI Reference In control on the Read/Write Control function.
NI 5761R User Guide and Specifications
10
ni.com
11. Wire the error out indicator of the Open FPGA VI Reference function to the error in control of
the Read/Write Control function.
12. Configure the Read/Write Control function by clicking the terminal section labeled Unselected,
and selecting IO Module/AI 0 Data N.
13. Add the IO Module/AI 0 Data N-1 I/O item to the Read/Write Control function by clicking the
lower edge of the control node with the Positioning tool and dragging the edge down.
14. Wire an indicator to the output terminal of the IO Module\AI 0 Data N node.
15. Wire an Indicator from the output terminal of the IO Module\AI 0 Data N-1 node.
16. Add the Close FPGA VI Reference function, located on the FPGA Interface palette, to the right
of the While Loop on the block diagram.
17. Wire the FPGA VI Reference Out indicator of the Read/Write Control function to the FPGA VI
Reference In control of the Close FPGA VI Reference function.
18. Wire the error out indicator of the Read/Write Control function to the error in control of the
Close FPGA VI Reference function.
Your block diagram should now resemble the block diagram in Figure 6.
Figure 6. 5761SampleAcq(Host).vi Block Diagram
19. Save the VI as 5761SampleAcq(Host).vi.
Running the Host VI
1.
Connect one end of an SMA cable to CH 0 on the front panel of the NI 5761 and the other end of
the cable to your DUT.
2.
Open the front panel of 5761SampleAcq(Host).vi.
3.
Click the Run button to run the VI.
4.
The VI acquires data from the DUT on AI 0 Data N and AI 0 Data N-1.
5.
Click the STOP button on the front panel and close the VI.
© National Instruments Corporation
11
NI 5761R User Guide and Specifications
How to Use Your NI FlexRIO Documentation Set
Refer to the Figure 7 and Table 4 for information about how to use your NI FlexRIO documentation set.
INSTALL Hardware
and Software
NI FlexRIO FPGA Module
Installation Guide and Specifications
CONNECT Signals
and Learn About
Your Adapter
Module
NI FlexRIO Adapter Module
User Guide and Specifications
PROGRAM Your
NI FlexRIO System
in LabVIEW FPGA
Module
Are
You New to
LabVIEW FPGA
Module?
LEARN About
LabVIEW FPGA
Module
Yes
No
No
LabVIEW FPGA
Module Help
NI FlexRIO
Help
LabVIEW
Examples
Figure 7. How to Use Your NI FlexRIO Documentation Set
Table 4. NI FlexRIO Documentation Locations and Descriptions
Document
Location
Description
NI FlexRIO FPGA
Module Installation
Guide and Specifications*
Available in your FPGA module
hardware kit and from the Start Menu.
Contains installation instructions for your
NI FlexRIO system and specifications for your
FPGA module.
NI Adapter Module User
Guide and Specifications*
Available in your adapter module
hardware kit and from the Start Menu.
Contains signal information, examples, and
specifications for your adapter module.
LabVIEW FPGA Module
Help*
Embedded in LabVIEW Help.
Contains information about the basic functionality of
LabVIEW FPGA Module.
NI FlexRIO Help*
Embedded in LabVIEW FPGA
Module Help.
Contains FPGA module, adapter module, and CLIP
configuration information.
LabVIEW Examples
Available in LabVIEW Example
Finder.
Contains examples of how to run FPGA VIs and
Host VIs on your device.
Other Useful Information on ni.com
ni.com/ipnet
Contains LabVIEW FPGA functions and intellectual property to share.
ni.com/flexrio
Contains product information and data sheets for NI FlexRIO devices.
* These
documents are also available at ni.com/manuals.
NI 5761R User Guide and Specifications
12
ni.com
Specifications
This section lists the specifications of the NI FlexRIO adapter module (NI 5761). Pair these
specifications with the specifications listed in the NI FlexRIO FPGA Module Installation Guide and
Specifications. For more information about safety and electromagnetic compatibility refer to the Read
Me First: Safety and Electromagnetic Compatibility document included in your hardware kit or
available at ni.com/manuals.
Caution
To avoid permanent damage to the NI 5761, disconnect all signals connected to the NI 5761
before powering down the module, and only connect signals after the module has been powered on
by the NI FlexRIO FPGA module.
Note
All numeric specifications are typical unless otherwise noted. All graphs illustrate the
performance of a representative module.
Typical values describe useful product performance that are not covered by warranty. Typical values
cover the expected performance of units over ambient temperature ranges of 23 ±5 °C with a 90%
confidence level, based on measurements taken during development or production.
Analog Input (AI CH 0 through AI CH 3)
General Characteristics
Number of channels ...............................................Four, single-ended, simultaneously sampled
Connector...............................................................SMA
Input impedance.....................................................50 Ω, per connector
Sample rate
Internal Sample clock ....................................250 MHz
External Sample clock ...................................175 MHz to 250 MHz
Digital data range...................................................±8,191
ADC part number...................................................ADS62P491; 14-bit resolution, dual ADC
AC-Coupled Specifications
Input range (normal operating conditions) ............2.07 Vpk-pk
Absolute maximum input.......................................±10 V DC, 5 Vpk-pk AC
Bandwidth (–3 dB).................................................0.1 MHz to 500 MHz
Bandwidth (–1 dB).................................................1 MHz to 250 MHz
1
For additional information on the ADS62P49, refer to the Texas Instruments device data sheet at www.ti.com.
© National Instruments Corporation
13
NI 5761R User Guide and Specifications
Table 5 lists the AC-coupled spectral performance measurements. All values are measured with a
250 MHz external Sample clock.
Table 5. AC-Coupled Spectral Performance
20.17 MHz
70.17 MHz*
123.17 MHz*
SNR
72.5 dB
71.4 dB
70.5 dB
SINAD
72.3 dB
71.2 dB
70.3 dB
SFDR
88 dB
84 dB
80 dB
Measurement
* These
measurements were extrapolated from a –4 dBFS plot.
Channel to channel isolation
1 MHz ............................................................>90 dB
100.1 MHz .....................................................90 dB
501 MHz ........................................................80 dB
Gain (dB)
AC-Coupled Measurements
5
4
3
2
1
0
–1
–2
–3
–4
–5
–6
–7
–8
–9
–10
–11
–12
–13
–14
–15
80k 100k
1M
10M
100M
700M
Frequency (Hz)
Figure 8. AC-Coupled Bandwidth (Passband)
NI 5761R User Guide and Specifications
14
ni.com
Amplitude (dBFS)
0
–5
–10
–15
–20
–25
–30
–35
–40
–45
–50
–55
–60
–65
–70
–75
–80
–85
–90
–95
–100
–105
–110
–115
0
20
40
60
80
100
120
Frequency (MHz)
Amplitude (dBFS)
Figure 9. AC-Coupled Spectral Measurements: 19.5 MHz and 20.5 MHz,
–13 dBFS, 8,192 Point FFT, 10 RMS Average
0
–5
–10
–15
–20
–25
–30
–35
–40
–45
–50
–55
–60
–65
–70
–75
–80
–85
–90
–95
–100
–105
–110
–115
0
10
20
30
40
50
60
70
80
90
100
110
120
Frequency (MHz)
Figure 10. AC-Coupled Spectral Measurements: 20.1 MHz, –1 dBFS, 8,192 Point FFT, 10 RMS Average
© National Instruments Corporation
15
NI 5761R User Guide and Specifications
Amplitude (dBFS)
0
–5
–10
–15
–20
–25
–30
–35
–40
–45
–50
–55
–60
–65
–70
–75
–80
–85
–90
–95
–100
–105
–110
–115
0
20
40
60
80
100
120
Frequency (MHz)
Figure 11. AC-Coupled Spectral Measurements: Terminated, 8,192 Point FFT, 10 RMS Average
DC-Coupled Specifications
Input range (normal operating conditions) ............1.23 Vpk-pk
Absolute maximum input.......................................±4.5 V DC
Bandwidth (–3 dB).................................................DC to 500 MHz
Bandwidth (–1 dB).................................................DC to 250 MHz
Table 6 lists the DC-coupled spectral performance measurements. All values are measured with a
250 MHz external Sample clock.
Table 6. DC-Coupled Spectral Performance
Measurement
20.1 MHz
70.1 MHz
122.1 MHz
SNR
65.7 dB
64.3 dB
63 dB
SINAD
65.2 dB
61.8 dB
56.6 dB
SFDR
76 dB
65 dB
58 dB
Channel to channel isolation
1 MHz ............................................................>90 dB
100.1 MHz .....................................................80 dB
501 MHz ........................................................70 dB
NI 5761R User Guide and Specifications
16
ni.com
To ensure proper device operation, DC-coupled channels on the NI 5761 must see 50 Ω at DC
looking back at their source. If you are connecting a to source with an output impedance less than
50 Ω, you can add series resistance close to the source to properly bias the NI 5761 input terminals.
You can also use the NI 5761 input channel bias DACs to remove DC offset present in the system.
For more information about programming the bias DACs, refer to the NI 5761 CLIP topics in the
NI FlexRIO Help.
Note
Gain (dB)
DC-Coupled Measurements
5
4
3
2
1
0
–1
–2
–3
–4
–5
–6
–7
–8
–9
–10
–11
–12
–13
–14
–15
0
10
100
1k
10k
100k
1M
10M
100M
700M
Frequency (Hz)
Figure 12. DC-Coupled Bandwidth (Passband)
© National Instruments Corporation
17
NI 5761R User Guide and Specifications
Amplitude (dBFS)
0
–5
–10
–15
–20
–25
–30
–35
–40
–45
–50
–55
–60
–65
–70
–75
–80
–85
–90
–95
–100
–105
–110
–115
0
25
50
75
100
125
Frequency (MHz)
Amplitude (dBFS)
Figure 13. DC-Coupled Spectral Measurements: 19.5 MHz and 20.5 MHz,
–13 dBFS, 8,192 Point FFT, 10 RMS Average
0
–5
–10
–15
–20
–25
–30
–35
–40
–45
–50
–55
–60
–65
–70
–75
–80
–85
–90
–95
–100
–105
–110
–115
0
10
20
30
40
50
60
70
80
90
100
110
120
Frequency (MHz)
Figure 14. DC-Coupled Spectral Measurements: 20.1 MHz, –1 dBFS, 8,192 Point FFT, 10 RMS Average
NI 5761R User Guide and Specifications
18
ni.com
Amplitude (dBFS)
0
–5
–10
–15
–20
–25
–30
–35
–40
–45
–50
–55
–60
–65
–70
–75
–80
–85
–90
–95
–100
–105
–110
–115
0
20
40
60
80
100
120
Frequency (MHz)
Figure 15. DC-Coupled Spectral Measurements: Terminated, 8,192 Point FFT, 10 RMS Average
Analog Input Phase Noise
–70.0
–80.0
Phase Noise (dBc/Hz)
–90.0
–100.0
–110.0
–120.0
–130.0
–140.0
–150.0
–160.0
0
1k
10k
100k
500k
Frequency Offset from 10 MHz Carrier (Hz)
Figure 16. Analog Input Phase Noise
© National Instruments Corporation
19
NI 5761R User Guide and Specifications
Internal Sample Clock
General Characteristics
Oscillator type........................................................Fixed frequency synthesizer
Frequency...............................................................250 MHz
Reference spurs......................................................<70 dBc
Phase noise
10 kHz offset..................................................–100 dBc/Hz
100 kHz offset................................................–120 dBc/Hz
Clock distribution part number ..............................AD95121; clock distribution
Reference clock sources.........................................Internal, External through the CLK IN connector, or
IoModSyncClk2
Internal reference type ...........................................TCXO
Internal reference stability .....................................±1 ppm
Internal reference frequency ..................................10 MHz
CLK IN
General Characteristics
Number of channels ...............................................1, single-ended
Connector...............................................................SMA
Input impedance.....................................................50 Ω
Input coupling ........................................................AC
External Sample Clock
Input voltage range ................................................0.63 Vpk-pk to 2.5 Vpk-pk
Input frequency range ............................................175 MHz to 250 MHz
Absolute maximum input.......................................±10 V DC, 3.1 Vpk-pk AC
External Reference Clock
Input voltage range ................................................1.4 Vpk-pk to 4.4 Vpk-pk
Input frequency range ............................................10 MHz
Absolute maximum input.......................................±10 V DC, 5 Vpk-pk AC
External Trigger
General Characteristics
Number of channels ...............................................1, single-ended
Connector...............................................................SMA
Input impedance.....................................................50 Ω
Input coupling ........................................................DC
1
2
For additional information about the AD9512, refer to the Analog Devices device data sheet at www.analog.com.
IoModSyncClk is available only on the NI PXIe-796xR FPGA modules.
NI 5761R User Guide and Specifications
20
ni.com
Input levels
Voltage Level
Minimum
Maximum
VIL
0V
0.7 V
VIH
1.7 V
5.5 V
Absolute maximum input.......................................–0.5 V to 7 V
PFI<0..7>
General Characteristics
Number of channels ...............................................8 bidirectional
Connector type.......................................................Micro–D
Interface standard...................................................2.5 V LVCMOS
Interface logic
Voltage Level
Minimum
Maximum
VIL
0V
0.7 V
VIH
1.7 V
5.5 V
VOL
0V
0.4 V
VOH
1.9 V
2.5 V
Zin ...................................................................17.5 kΩ
Zout .................................................................50 Ω
Iout...................................................................2 mA
Maximum toggle frequency...................................500 kHz
Absolute maximum input.......................................–0.5 V to 7 V
EEPROM Map
Byte Address
Size (Bytes)
Field Name
0x0
2
Vendor ID
0x2
2
Product ID
0x4
4
Serial Number
0x8
116
Reserved
0x7C
132
User Space
Caution Only write to User Space. Writing to any other offset may cause the NI 5761 to stop
functioning.
© National Instruments Corporation
21
NI 5761R User Guide and Specifications
Power
Total power, typical operation................................5.3 W
Physical
Dimensions ............................................................12.9 × 2.0 × 12.1 cm
(5.1 × 0.8 × 4.7 in.)
Weight ....................................................................312 g (11 oz)
Front panel connectors...........................................6 SMA and one Micro-D connector
Environmental
The NI 5761 is intended for indoor use only.
Operating environment1 .........................................0 °C to 55 °C,
tested in accordance with IEC-60068-2-1 and
IEC-60068-2-2.
Relative humidity range .........................................10% to 90%, noncondensing,
tested in accordance with IEC-60068-2-56.
Altitude ..................................................................2,000 m at 25 °C ambient temperature.
Pollution Degree ....................................................2
Storage environment
Ambient temperature range ...........................–20 °C to 70 °C,
tested in accordance with IEC-60068-2-1 and
IEC-60068-2-2.
Relative humidity range .................................5% to 95%, noncondensing,
tested in accordance with IEC-60068-2-56.
Note Clean the device with a soft, non-metallic brush. Make sure that the device is completely dry
and free from contaminants before returning it to service.
Safety
This product meets the requirements of the following standards of safety for electrical equipment for
measurement, control, and laboratory use:
•
IEC 61010-1, EN 61010-1
•
UL 61010-1, CSA 61010-1
Note For UL and other safety certifications, refer to the product label or the Online Product
Certification section.
1
For PXI/PXI Express chassis configurations that group NI FlexRIO adapter modules in three or more contiguous slots,
National Instruments recommends limiting the ambient operating temperature to less than 50 °C.
NI 5761R User Guide and Specifications
22
ni.com
Electromagnetic Compatibility
This product meets the requirements of the following EMC standards for electrical equipment for
measurement, control, and laboratory use:
•
EN 61326-1 (IEC 61326-1): Class A emissions; Basic immunity
•
EN 55011 (CISPR 11): Group 1, Class A emissions
•
AS/NZS CISPR 11: Group 1, Class A emissions
•
FCC 47 CFR Part 15B: Class A emissions
•
ICES-001: Class A emissions
Note
For EMC declarations and certifications, refer to the Online Product Certification section of
this document.
Caution
For EMC compliance, operate this device with shielded cables and accessories.
CE Compliance
This product meets the essential requirements of applicable European Directives as follows:
•
2006/95/EC; Low-Voltage Directive (safety)
•
2004/108/EC; Electromagnetic Compatibility Directive (EMC)
Online Product Certification
To obtain product certifications and the Declaration of Conformity for this product, visit ni.com/
certification, search by model number or product line, and click the appropriate link in the
Certification column.
Environmental Management
National Instruments is committed to designing and manufacturing products in an environmentally
responsible manner. NI recognizes that eliminating certain hazardous substances from our products is
beneficial not only to the environment but also to NI customers.
For additional environmental information, refer to the NI and the Environment Web page at ni.com/
environment. This page contains the environmental regulations and directives with which NI
complies, as well as other environmental information not included in this document.
Waste Electrical and Electronic Equipment (WEEE)
EU Customers At the end of the product life cycle, all products must be sent to a WEEE recycling
center. For more information about WEEE recycling centers, National Instruments WEEE initiatives,
and compliance with WEEE Directive 2002/96/EC on Waste and Electronic Equipment,
visit ni.com/environment/weee.
⬉ᄤֵᙃѻક∵ᶧ᥻ࠊㅵ⧚ࡲ⊩ ˄Ё೑ RoHS˅
Ё೑ᅶ᠋ National Instruments ヺড়Ё೑⬉ᄤֵᙃѻકЁ䰤ࠊՓ⫼ᶤѯ᳝ᆇ⠽䋼ᣛҸ (RoHS)DŽ
݇Ѣ National Instruments Ё೑ RoHS ড়㾘ᗻֵᙃˈ䇋ⱏᔩ ni.com/environment/rohs_chinaDŽ
(For information about China RoHS compliance, go to ni.com/environment/rohs_china.)
© National Instruments Corporation
23
NI 5761R User Guide and Specifications
Where to Go for Support
The National Instruments Web site is your complete resource for technical support.
At ni.com/support you have access to everything from troubleshooting and
application development self-help resources to email and phone assistance from
NI Application Engineers.
National Instruments corporate headquarters is located at 11500 North Mopac
Expressway, Austin, Texas, 78759-3504. National Instruments also has offices
located around the world to help address your support needs. For telephone support
in the United States, create your service request at ni.com/support and follow
the calling instructions or dial 512 795 8248. For telephone support outside the
United States, contact your local branch office:
Australia 1800 300 800, Austria 43 662 457990-0, Belgium 32 (0) 2 757 0020,
Brazil 55 11 3262 3599, Canada 800 433 3488, China 86 21 5050 9800,
Czech Republic 420 224 235 774, Denmark 45 45 76 26 00,
Finland 358 (0) 9 725 72511, France 01 57 66 24 24, Germany 49 89 7413130,
India 91 80 41190000, Israel 972 3 6393737, Italy 39 02 41309277,
Japan 0120-527196, Korea 82 02 3451 3400, Lebanon 961 (0) 1 33 28 28,
Malaysia 1800 887710, Mexico 01 800 010 0793,
Netherlands 31 (0) 348 433 466, New Zealand 0800 553 322,
Norway 47 (0) 66 90 76 60, Poland 48 22 328 90 10, Portugal 351 210 311 210,
Russia 7 495 783 6851, Singapore 1800 226 5886, Slovenia 386 3 425 42 00,
South Africa 27 0 11 805 8197, Spain 34 91 640 0085,
Sweden 46 (0) 8 587 895 00, Switzerland 41 56 2005151,
Taiwan 886 02 2377 2222, Thailand 662 278 6777, Turkey 90 212 279 3031,
United Kingdom 44 (0) 1635 523545
LabVIEW, National Instruments, NI, ni.com, the National Instruments corporate logo, and the Eagle
logo are trademarks of National Instruments Corporation. Refer to the Trademark Information at
ni.com/trademarks for other National Instruments trademarks. Other product and company
names mentioned herein are trademarks or trade names of their respective companies. For patents
covering National Instruments products/technology, refer to the appropriate location: Help»Patents
in your software, the patents.txt file on your media, or the National Instruments Patent Notice
at ni.com/patents.
© 2010 National Instruments Corporation. All rights reserved.
375509A-01
May10