POL-HX017 - Premier Magnetics

TABLE 1: ELECTRICAL SPECIFICATIONS AT 25 OC
PARAMETER
MIN.
PRIMARY INDUCTANCE (1-3)
V = 0.40Vrms, F = 100 KHZ
SPEC LIMITS
TYP.
309
FIGURE 1: SCHEMATIC DIAGRAM
MAX.
343
NC
NC
UNITS
377
SHIELD
uH
1
TURNS RATIO'S:
3-1 : 4-5
3-1 : FL1-FL2
---------------
1:.147
1:.176
---------------
--------
--------
10
PRIMARY 2/2
+ 4%
+ 4%
2
PRIMARY 1/2
LEAKAGE INDUCTANCE (1-3)
V = 0.40Vrms, F = 100 KHZ
SHORT BIAS AND SECONDARY.
H
1
---------
---------
MHz
HIP OT:
PRIMARY TO SECONDARY
BIAS TO SECONDARY
3000
3000
---------------
---------------
VRMS
VRMS
SECONDARY
3
4
RESONANT FREQUENCY (1-3).
FL1
FL2
BIAS
5
FIGURE 2: PHYSICAL DIMENSIONS mm (INCHES)
FL1
FL2
10
9
P
M
PIN #1
WHITE DOT
1
8
7
6
POL-HX017
YYWW
2
3
4
Leads Length
FL1 = 50mm
FL2 = 40mm
5
29.0
(1.141)
Max.
28.5
(1.122)
Max.
24.2
(.953)
Max.
1
2
3
5.0
(.197)
4
0.8 DIA.
(.032)
5
3.2
(.126)
Min.
NOTES:
1) Design to comply with the requirements of UL/CSA/
IEC60950-1.
2) Design to comply with the requirements if UL/CSA/IEC
Class B insulation system.
3) All materials per Premier Magnetics UL file #E177139.
4) All units comply with the requirements of the EU RoHS
Directive.
21.9
(.862)
RoHS
UNLESS OTHERWISE SPECIFIED
DIMENSIONS ARE IN mm.
DIMENSIONAL TOLERANCES ARE:
DECIMALS
ANGLES
.X
+ .25
+0 O 30'
.XX + .15
DRAW ING NOT TO SCALE.
REV.
DESCRIPTION OF CHANGES
BY
05/14/13
ORIGINAL RELEASE
KC
TRANSFORMER CONTROL DRAWING
PREMIER P/N: POL-HX017
REVISION: 05/14/13
ENG: PETER PHAM
REF: TOP259EN
QA: Kevin Clark
SHEET: 1 OF 1