POL-HX014 - Premier Magnetics

TABLE 1: ELECTRICAL SPECIFICATIONS AT 25 OC
PARAMETER
MIN.
PRIMARY INDUCTANCE (1-2)
VOLTAGE = 0.40Vrms
FREQUENCY = 130 KHZ
PRI LEAKAGE IND. (1-2). Short Sec.
VOLTAGE = 0.40Vrms
FREQUENCY = 130 KHZ
SPEC LIMITS
TYP.
902
1002
--------
--------
MAX.
FIGURE 1: SCHEMATIC DIAGRAM
UNITS
1103
H
19
H
SHIELD
1
PRIMARY
TURN RATIO'S:
1-2 : 4-5
1-2 : FL1-FL2
---------------
9.6 : 1
15.4: 1
---------------
+ 4%
+ 4%
RESONANT FREQUENCY
1000
--------
-------
KHz
2
4
FL1
SECONDARY 1/2
SECONDARY 2/2
FL2
BIAS
5
HIPOT: 60hZ for 1 sec.
PRIMARY and BIAS TO SEC.
3000
--------
--------
Vrms
FIGURE 2: PHYSICAL DIMENSIONS mm.
FL1
FL2
10
8
9
7
6
PM POL-HX014
YYWW
PIN #1
WHITE DOT
1
2
Leads Lenght
FL1 = 35mm
FL2 = 25mm
3
4
5
23.5
Max.
21.0
Max.
32.0
Max.
1
2
3
4
NOTES:
0.80
DIA.
5
15.0
4.75
3.75
3.2
Min
1) Design to comply with the requirements of UL/CSA/
IEC60950-1.
2) Design to comply with the requirements if UL/CSA/IEC
Class B insulation system.
3) All materials per Premier Magnetics UL file #E177139.
4) All units comply with the requirements of the EU RoHS
Directive.
REV.
DESCRIPTION OF CHANGES
BY
05/09/13
Original Release.
KC
RoHS
UNLESS OTHERWISE SPECIFIED
DIMENSIONS ARE IN mm.
DIMENSIONAL TOLERANCES ARE:
DECIMALS
ANGLES
.X
+ 0.3
+0 O 30'
.XX + 0.20
DRAW ING NOT TO SCAL.E
TRANSFORMER CONTROL DRAWING
PREMIER P/N: POL-HX014
REVISION: 05/09/13
ENG: Peter Pham
REF: TOP254EN
QA: Kevin Clark
SHEET: 1 OF 1