product spec sheets

MTU Onsite Energy
Gas CHP Systems
Series 4000
762 – 2,129 kWel
Natural Gas
Genset Type
Features
//
Proven mechanical components
//
Very high power density
//
Cylinder-selective knock control
//
Factory tested with comprehensive performance
evaluation
//
Single cylinder heads with four-valve technology
MTU 8V4000 GS
MTU 8V4000 GS
MTU 12V4000 GS
MTU 12V4000 GS
MTU 16V4000 GS
MTU 16V4000 GS
MTU 20V4000 GS
MTU 20V4000 GS
Electrical
Thermal
(kWe)
Efficiency
Jacket Water
(kBTU/hr)
Exhaust
(kBTU/hr) *
Aftercooler
(°F)
762
840
1151
1268
1542
1697
1932
2129
40.7%
41.7%
41.5%
42.2%
41.8%
42.1%
41.8%
42.3%
1554
1544
2203
2315
3009
3398
3610
4040
1448
1547
2203
2271
2777
2831
3798
3716
127
104
127
104
127
104
127
104
Aftercooler
(°F)
127
104
127
104
127
104
127
104
Biogas
Genset Type
MTU 8V4000 GS
MTU 8V4000 GS
MTU 12V4000 GS
MTU 12V4000 GS
MTU 16V4000 GS
MTU 16V4000 GS
MTU 20V4000 GS
MTU 20V4000 GS
Electrical
(kWe)
Efficiency
Jacket Water
(kBTU/hr)
Thermal
Exhaust
(kBTU/hr) *
762
762
1151
1151
1542
1542
1932
1932
40.6%
41.8%
41.3%
41.9%
41.8%
42.2%
41.8%
42.6%
1458
1322
2158
1991
2261
2189
2664
2558
1206
1107
1790
1684
2315
2251
2954
3012
Series 400
128 – 358 kWel
Natural Gas
Genset Type
MTU 6R400 GS
MTU 12V400 GS
MTU 12V400 GS
Electrical
Efficiency
(kWe)
Total
Thermal
Jacket Water
Exhaust
(kBTU/hr)
(kBTU/hr) *
128
248
358
91.0%
91.8%
90.0%
410
867
878
321
577
915
Biogas
Genset Type
Features
//
Continuous development and optimization for
more than 35 years
//
Meets common industrial quality standards
//
Highest overall efficiency in its power range
(up to 91.9%)
//
Sophisticated compact design
//
Factory tested with comprehensive performance
evaluation
//
Cylinder-selective knock control
MTU 6R400 GS
MTU 12V400 GS
Electrical
Efficiency
(kWe)
Total
Thermal
Jacket Water
Exhaust
(kBTU/hr)
(kBTU/hr) *
200
350
88.7%
85.7%
512
816
509
772
* exhaust cooled to 356°F