GAS SYSTEM SERIES 4000 NATURAL GAS 6,3 kV / 50 Hz* SYSTEM RATINGS Natural gas genset without heat extraction (heat recovery unit not included in delivery) MTU Onsite Energy Type GB 1166 N5 GB 1557 N5 GB 1950 N5 Former Output Genset Type Elect.1) Therm.2) Low Temp. AoE kWel. kWth. kWth. (°C) L33 (Methane number 70) 12V 4000 L33 1166 (600) 80 (40) 16V 4000 L33 1557 (885) 99 (40) 20V 4000 L33 1950 (1050) 125 (40) GB 1166 N5 GB 1557 N5 GB 1950 N5 L32 (High ambient temperatures) 12V 4000 L32 1166 (632) 16V 4000 L32 1557 (863) 20V 4000 L32 1950 (1035) 43 (53) 76 (53) 78 (53) 2747 3651 4577 42.4 42.6 42.6 (65.5) (66.3) (65.2) ≥ 80 ≥ 80 ≥ 80 4700x1800x2400 5500x1800x2400 6000x1800x2400 GB 1284 N5 GB 1713 N5 GB 2145 N5 L33 (Highest output) 12V 4000 L33 1284 16V 4000 L33 1713 20V 4000 L33 2145 88 (40) 113 (40) 142 (40) 2974 3991 4985 43.2 42.9 43.0 (65.5) (67.3) (66.3) ≥ 80 ≥ 80 ≥ 80 4700x1800x2400 5500x1800x2400 6000x1800x2400 (664) (974) (1158) Energy input4) kW Efficiency Elect. Total nel. (%) ntot (%) 2731 3649 4560 42.7 42.7 42.8 (64.7) (66.9) (65.8) ≥ 70 ≥ 70 ≥ 70 4700x1800x2400 5500x1800x2400 6000x1800x2400 * NOx < 500 mg/mn3 (NOx < 250 mg/mn3 available) 1) Rated power at nominal voltage, power factor = 1 and nominal frequency 2) from jacket water, tolerance 8% 4) performance data in accordance with ISO 3046, tolerance 5% 5) referenced methane number All data according to full load, indicated gas mixture cooler water inlet temperature and are subject to technical development. Methane Number5) 3) from jacket water and exhaust gas (120°C), tolerance 8% 6) dimensions without exhaust gas heat exchanger Project specific data on request: - Other gas types - Container Dimensions (L x W x H) mm - Individual data (e.g. flow-/return-temperatures, hot cooling, methane number, assembly space, etc.) - Gas Processing GAS SYSTEM SERIES 4000 NATURAL GAS 6,3 kV / 50 Hz* SYSTEM RATINGS Natural gas genset with heat extraction from jacket water (heat recovery unit included in delivery) MTU Onsite Energy Type GR 1166 N5 GR 1557 N5 GR 1950 N5 Former Output KWK Type Elect.1) Therm.2) Low Temp. AE kWel. kWth. kWth. (°C) L33 (Methane number 70) 12V 4000 L33 1166 600 80 (40) 16V 4000 L33 1557 885 99 (40) 20V 4000 L33 1950 1050 125 (40) GR 1166 N5 GR 1557 N5 GR 1950 N5 L32 (High ambient temperatures) 12V 4000 L32 1166 632 16V 4000 L32 1557 863 20V 4000 L32 1950 1035 43 (53) 76 (53) 78 (53) 2747 3651 4577 42.4 42.6 42.6 65.5 66.3 65.2 ≥ 80 ≥ 80 ≥ 80 6300x1850x2400 7100x1850x2400 7600x1850x2400 GR 1284 N5 GR 1713 N5 GR 2145 N5 L33 (Highest output) 12V 4000 L33 1284 16V 4000 L33 1713 20V 4000 L33 2145 88 (40) 113 (40) 142 (40) 2974 3991 4985 43.2 42.9 43.0 65.5 67.3 66.3 ≥ 80 ≥ 80 ≥ 80 6300x1850x2400 7100x1850x2400 7600x1850x2400 664 974 1158 Energy input4) kW Efficiency Elect. Total nel. (%) ntot (%) 2731 3649 4560 42.7 42.7 42.8 64.7 66.9 65.8 ≥ 70 ≥ 70 ≥ 70 6300x1850x2400 7100x1850x2400 7600x1850x2400 * NOx < 500 mg/mn3 (NOx < 250 mg/mn3 available) 1) Rated power at nominal voltage, power factor = 1 and nominal frequency 2) from jacket water, tolerance 8% 4) performance data in accordance with ISO 3046, tolerance 5% 5) referenced methane number All data according to full load, indicated gas mixture cooler water inlet temperature and are subject to technical development. Methane Number5) 3) from jacket water and exhaust gas (120°C), tolerance 8% 6) dimensions without exhaust gas heat exchanger Project specific data on request: - Other gas types - Container Dimensions (L x W x H) mm - Individual data (e.g. flow-/return-temperatures, hot cooling, methane number, assembly space, etc.) - Gas Processing GAS SYSTEM SERIES 4000 NATURAL GAS 6,3 kV / 50 Hz* SYSTEM RATINGS Natural gas genset with heat extraction from jacket water (heat recovery unit included in delivery) and exhaust gas (exhaust gas heat exchanger loose supply) MTU Onsite Energy Type GC 1166 N5 GC 1557 N5 GC 1950 N5 GC 1166 N5 GC 1557 N5 GC 1950 N5 L32 (High ambient temperatures) 12V 4000 L32 1166 1270 16V 4000 L32 1557 1668 20V 4000 L32 1950 2170 43 (53) 76 (53) 78 (53) 2747 3651 4577 42.4 42.6 42.6 88.7 88.3 90.0 ≥ 80 ≥ 80 ≥ 80 6300x1850x2400 7100x1850x2400 7600x1850x2400 GC 1284 N5 GC 1713 N5 GC 2145 N5 L33 (Highest output) 12V 4000 L33 1284 16V 4000 L33 1713 20V 4000 L33 2145 88 (40) 113 (40) 142 (40) 2974 3991 4985 43.2 42.9 43.0 87.7 87.9 88.5 ≥ 80 ≥ 80 ≥ 80 6300x1850x2400 7100x1850x2400 7600x1850x2400 1323 1795 2268 Energy input4) kW Efficiency Elect. Total nel. (%) ntot (%) 2731 3649 4560 42.7 42.7 42.8 87.7 88.2 88.8 ≥ 70 ≥ 70 ≥ 70 6300x1850x2400 7100x1850x2400 7600x1850x2400 * NOx < 500 mg/mn3 (NOx < 250 mg/mn3 available) 1) Rated power at nominal voltage, power factor = 1 and nominal frequency 2) from jacket water, tolerance 8% 4) performance data in accordance with ISO 3046, tolerance 5% 5) referenced methane number All data according to full load, indicated gas mixture cooler water inlet temperature and are subject to technical development. Methane Number5) Dimensions6) (L x W x H) mm Former Output KWK Type Elect.1) Therm.3) Low Temp. AE kWel. kWth. kWth. (°C) L33 (Methane number 70) 12V 4000 L33 1166 1228 80 (40) 16V 4000 L33 1557 1662 99 (40) 20V 4000 L33 1950 2098 125 (40) 3) from jacket water and exhaust gas (120°C), tolerance 8% 6) dimensions without exhaust gas heat exchanger Project specific data on request: - Other gas types - Container - Individual data (e.g. flow-/return-temperatures, hot cooling, methane number, assembly space, etc.) - Gas Processing H DRAWINGS AND DIMENSIONS L B Note: This drawing is provided for reference only and should not be used for planning installation. ENGINE DATA 90° V 12/16/20 170/210 mm 4.77 lit. 1500 rpm DESIGN AND EQUIPMENT (EXTRACT) // Sliding gear starter 24V, 2 x 9 kW // Gas supply through venturi air-gas mixer with electronically controlled gas metering valve // Electronic high-voltage capacitor ignition system with one ignition coil per cylinder // Electronic speed governor for speed and power output control with automatic knocking control // Oil sump, removable without lifting the engine Version: 11.04.2013, materials and specifications subject to change without notice due to technical advances. MTU Onsite Energy A Rolls-Royce Power Systems Brand www.mtuonsiteenergy.com Subject to change. | 3234751 | Edition 01/14 | ENC 2014-01 | Printed in Germany on chlorine-free bleached papaer. 4000 Configuration No. of cylinders Bore/Stroke Cyl. displacement Rated speed