GAS system Series 4000 natural gas 400V / 50 Hz NOx < 500 mg/Nm3 System Ratings Gas genset with optional heat recovery module Genset Engine Type Type MTU 8V4000 GS L33 MTU 8V4000 GS L33 MTU 8V4000 GS L64 MTU 12V4000 GS L33 MTU 12V4000 GS L64 MTU 16V4000 GS L33 MTU 16V4000 GS L64 MTU 16V4000 GS L64 MTU 20V4000 GS L33 MTU 20V4000 GS L64 Output Elect.1) Therm.2) Exhaust3) Low Temp. kWel. kWth. kWth. (°C) kWth. (°C) 776 401 422 (120) 47 (40) 854 443 448 (120) 49 (40) 1012 475 461 (120) 69 (43) 1286 664 659 (120) 88 (40) 1523 712 691 (120) 104 (43) 1718 974 821 (120) 113 (40) 1999 950 928 (120) 125 (43) 2028 965 936 (120) 127 (43) 2145 1161 1078 (120)142 (40) 2535 1186 1212 (120) 176 (43) Energy input4) kW 1832 1993 2298 2974 3438 3991 4511 4573 4990 5751 Efficiency Electr. Total ntot (%) nel. (%) 42.4 87.3 42.8 87.5 44.0 84.8 43.2 87.7 44.3 85.1 43.0 88.0 44.3 85.9 44.3 85.9 43.0 87.9 44.1 85.8 Methane number5) ≥ 70 ≥ 80 ≥ 80 ≥ 80 ≥ 80 ≥ 80 ≥ 80 ≥ 80 ≥ 80 ≥ 80 Hot ambient conditions MTU 8V4000 GS MTU 12V4000 GS MTU 16V4000 GS MTU 20V4000 GS L32 L32 L32 L32 776 1169 1560 1948 446 632 863 1035 420 (120) 32 (53) 638 (120) 43 (53) 805 (120) 76 (53) 1101 (120) 78 (53) 1853 2747 3651 4577 41.9 42.5 42.7 42.6 88.6 88.8 88.4 89.2 ≥ 80 ≥ 80 ≥ 80 ≥ 80 921 1143 937 (120) 84 (53) 1181 (120) 99 (53) 3848 4812 40.5 40.5 88.8 88.8 ≥ 60 ≥ 60 Low methane number MTU 16V4000 GS MTU 20V4000 GS L32 ER L32 ER 1560 1948 1) Rated power at nominal voltage, power factor = 1,0 and nominal frequency 3) Heat output from exhaust (exhaust cooling to 120°C) with tolerance of ± 8% 5) Referenced methane number 2) Heat output from engine cooling with tolerance of ± 8% 4) Performance data in accordance with ISO 3046/I-2002 with tolerance of 5% Project specific data on request: - different alternator voltage - different flow-/return-temperatures, hot cooling, methane number, installation conditions etc. - Container Drawings and dimensions Note: This drawing is provided for reference only and should not be used for installation planning. Genset Type MTU 8V4000 GS MTU 12V4000 GS MTU 16V4000 GS MTU 20V4000 GS Dimensions Genset (L x W x H) 4200 x 2000 x 2400 mm 5000 x 2000 x 2400 mm 5500 x 2000 x 2600 mm 6000 x 2000 x 2600 mm Heat recovery module (Lh x W x H) 1500 x 1900 x 2000 mm 1500 x 1900 x 2000 mm 1500 x 1900 x 2000 mm 1500 x 1900 x 2000 mm 4000 Configuration No. of cylinders Bore/Stroke Cyl. displacement 90° V 8/12/16/20 170/210 mm 4.77 lit. design and equipment (extract) // Sliding gear starter 24V // Gas supply with electronically controlled gas metering valve // Electronic high-voltage capacitor ignition system with one ignition coil per cylinder // Electronic speed governor for speed and power output control with automatic knocking control Any specifications, descriptions, values, data or other information related to dimensions, power or other technical performance criteria of the goods as provided in this general productinformation are to be understood as non-binding and may be subject to further changes such as but not limited to technical evolution at any time. Version: 01.08.2014, materials and specifications subject to change without notice due to technical advances. MTU Onsite Energy A Rolls-Royce Power Systems Brand www.mtuonsiteenergy.com Subject to change. | 3234731 | Edition 01/15 | ENC 2015-04 | Printed in Germany on chlorine-free bleached papaer. Engine Data