NV-300

NV-300
www.uk.tdk-lambda.com/nv
Medical
Industrial
Test
Broadcast
Comms
300W Configurable
power supply.
Renewable
Features
Benefits
• High Efficiency
Minimises heat in system
• Low Profile
Fits 1U Applications
• High Power Density
Requires less space
• Up To 5 Outputs
Eliminates need for additional supplies
• 3 Year Warranty
Low cost of ownership
Input
Input Voltage
90-264Vac
(below 100Vac input, derate by 3W / V)
Input Frequency
45 - 63Hz
(440Hz with reduced PFC - consult factory)
Input Harmonics
EN61000-3-2 compliant
Power Factor
0.97 typical
Input Fuse
6.3A Fast acting (not user accessible)
Inrush Current
15A typical at 25°C and 230Vac (cold start)
Earth Leakage
Current
123µA at 120Vac (60Hz), 257µA max at 240Vac (60Hz)
Worst case leakage current is less than 300µA at 264Vac, 63Hz (normal condition, 0.5mA Single Fault Condition)
How To Create A Product Description
NVA3-
#o/p
Ch1
Ch2
Ch3
Ch4
Global Case
Option Option
Number of outputs
(excluding standby and fan supplies)
Blank
-C
-U
-F
-I
no case
U chassis + cover
U chassis
End fan + case1
IEC input, end fan + case1
Blank no option
-N3 5V/2A ATX compatible
-N4 5V/2A ATX compatible
Letter/number from ‘Available Outputs’
Ch1 - Ch4
table to represent output voltage
1 - Needs ‘0H’, ‘3H’, ‘5H’, ‘TH’ or ‘FH’ type channel 4. The fan speed is temperature
dependent, ensuring optimum cooling and lowest audible noise
Confirm availability of created product with TDK-Lambda
QUICK SELECTOR - example configurations
Model
Ch1
Ch2
Ch3
Ch4
Ch5
Global Option
NVA3-453TTH
5V / 40A
3.3V / 15A
12V / 5A
-12V / 2A
-
No
NVA3-453TTH-N3
5V / 40A
3.3V / 15A
12V / 5A
-12V / 2A
5V / 2A
ATX (-N3)
NVA3-350TTH
5V / 40A
-
12V / 5A
-12V / 2A
-
No
ATX (-N3)
NVA3-350TTH-N3
5V / 40A
-
12V / 5A
-12V / 2A
5V / 2A
NVA3-453FFH
5V / 40A
3.3V / 15A
15V / 5A
-15V / 2A
-
No
NVA3-453FFH-N3
5V / 40A
3.3V / 15A
15V / 5A
-15V / 2A
5V / 2A
ATX (-N3)
NVA3-350FFH
5V / 40A
-
15V / 5A
-15V / 2A
-
No
NVA3-350FFH-N3
5V / 40A
-
15V / 5A
-15V / 2A
5V / 2A
ATX (-N3)
NV-300
1
AVAILABLE OUTPUTS
Adjustment
Range5
Channel 1
5
5 - 5.5V
5V / 40A2
1
1.8V / 15A
0.9 - 2.5V
2
2.7V / 15A
2.5 - 3.8V
3
3.3V / 15A
2.5 - 3.8V
2H
2.7V / 24A
2.5 - 3.8V
3.3V / 24A
2.5 - 3.8V
3H
0
T
G
12V / 25A
12 - 13V
24V / 12.5A
24 - 28V7
Adjustment
Range5
Channel 21
Channel 3
T
TH
F
FH
G
0
Omit
5
5V / 10A
3.3 - 5.5V
5H
5V / 16A
3.3 - 5.5V
0
Omit
5
5V / 8A
5 - 5.5V
5H
5V / 12.5A
5 - 5.5V
T
12V / 10A
12 - 15.5V
F
15V / 10A
12 - 15.5V
0
Omit
1. 1, 2, 3, 2H & 3H channel 2 only available with 5V channel 1.
5V / 10A channel 2 only available with 12 or 15V channel 1.
5V / 8A channel 2 only available with 24V channel 1
2. Maximum combined output current from Ch1 + Ch2 = 40A
3.
4.
5.
6.
Adjustment
Range5
12V / 5A4
12V / 8A6
15V / 4A4
15V / 6.4A6
24V / 2.5A
Omit
12 - 15V
12 - 15V
12 - 15V
12 - 15V
18 - 24V
Follow output letters by ‘P’ for positive output channel 4.
60W max output power
Max voltage at the output (includes remote sense)
96W max output power
Channel 43
3H
5H
TH
FH
0H
0
-3.3V / 2A8
-5V / 2A8
-12V / 2A8
-15V / 2A8
Fan supply only
Omit
Adjustment
Range
Fixed
Fixed
Fixed
Fixed
7. 24-24.5V if any channel 2 fitted
24 - 26V is 24V channel 3 fitted
8. 1.5A max if fitted with ‘-F’ option.
Other output options are available, please consult TDK-Lambda with your requirements
Output Specification
Voltage / Current
See available outputs
Turn on time
1.5s max
at 90Vac and 100% rated output power
Efficiency
up to 90%
configuration dependent
Hold up
16ms min
at 90Vac
(or 50mV if higher) pk-pk, using EIAJ test method & 20MHz bandwidth
Ripple and Noise
<1%
Voltage Accuracy
±1%
±5% for Channel 4
Remote Sense
Yes
Channels 1 & 2. Max 0.5V total line drop
Minimum Load
No
Total Regulation
1.5%
Transient Response
<5%
Recovery
on any output
For channels 1, 2 and 3 (2.5% for channel 4)
Including Line (for 90-264Vac input change), Load (for 0-100% load change) and
Cross (for 0-100% load change on any other output) regulation
of set voltage for 40% load change
(in 50µs within the range 25-100% load)
500µs
for recovery to 1% of set voltage
See Application Notes for details
Over Voltage Protection
Yes
Short Circuit Protection
Yes
Over Temperature Protection
Yes
Ch1 Good Signal
Yes
Output Power
1.5% for units with 5V channel 1
300W
Provides a Logic ‘Low’ signal after Channel 1 output is within 90% (±5%) of nominal.
Total output power from all outputs
for Vin above 180Vac, max output power = 300W + standby supply
Isolation
Input to Output
Reinforced
Input to Earth
Basic
Output to Earth
2
2 x MOOPs (3rd edition 60601)
4.3kVdc
2.3kVdc
200Vdc
NV-300
Global Interface Signals - units fitted with N3 or N4 options
ATX Remote on/off
TTL high or open circuit will inhibit all outputs (except Standby)
ATX Power Good
Logic high indicates ac supply is good and output 1 is within regulation
Standby Supply
Common 0V with power supply. Not affected by ATX remote on/off
-N3 Option = 5V / 2A
-N4 Option = 12V / 1A
Environment
Temperature
0°C to 50°C operational, -40°C to 70°C storage (max 12 months).
Full load, with either ‘-F’ option fitted or 1.5m/s air blown from input to output (approximately 10CFM)
Derating
50°C to 65°C derate each output by 2.5% per °C
Low Temp Startup
-20°C
Humidity
5 - 95% RH non condensing
Shock
±3 x 30g shocks in each plane, total 18 shocks
30g shock = 11ms (+/-0.5msec), half sine
Conforms to EN60068-2-27, EN60068-2-47, IEC68-2-27, IEC68-2-47, JIS C0041-1987.
Conforms to MIL-STD-810E/F, Method 516.5, Pro I, IV, VI
Vibration
Single axis 10 - 500 Hz at 2g (sweep and endurance at resonance) in all 3 planes
Conforms to EN60068-2-6, IEC68-2-6
Conforms to MIL-STD-810E, Method 514.4, Pro I, Cat 1,9
Altitude
3000 metres operational
Pollution
Degree 2, Material group IIIb
Immunity EN61000-6-2:2005, EN60601-1-2:2001
Criteria
Electrostatic Discharge
EN61000-4-2
Level 4
Air discharge 15kV, Contact discharge 8kV. Not applicable to open
frame units
Electromagnetic Field
EN61000-4-3
Level 3
12V/m
A
A
A
Fast / Burst Transient
EN61000-4-4
Level 4
ac input tested to 4.4kV
dc output tested to 2.2kV
Surge Immunity
EN61000-4-5
Level 3
Common mode - 2.2kV, Differential - 1.1kV
A
Conducted RF Immunity
EN61000-4-6
Level 3
12V
A
Power Frequency Magnetic Field
EN61000-4-8
Level 4
30A/m
A
Voltage Dips, Variations, Interruptions
EN61000-4-11
Class 3
Criteria B for 5 sec interruption
A
Voltage Fluctuations
EN61000-4-14
Class 3
For 100 - 240V Nominal
A
Emissions EN61000-6-3:2007, EN60601-1-2:2001
Radiated Electric Field
EN55011, EN55022
(as per CISPR.11/22) Class B, FCC47 part 15 subpart B
Conducted Emissions
EN55011, EN55022
(as per CISPR.11/22) Class B, FCC47 part 15 subpart B
Conducted Harmonics
EN61000-3-2
Class A
Flicker
EN61000-3-3
Compliant - dmax only
see application note for details. Additional filtering required for IEC inlet version.
Safety Approvals
Notes
IEC/EN 60950-1, UL60950-1 / CSA 22.2 No 60950-1
File E135494
IEC/EN 60601-1, UL/CSA 60601-1, ANSI/AAMI ES60601-1
CAN/CSA-C22.2 No 60601-1-08
File E349607
IEC/EN 61010-1
Designed to meet
CE Mark (EN60950-1)
LV Directive 2006/95/EC
CB certificate and Report available on request
Please check with technical sales for status of approvals
NV-300
3
OUTLINE & CONNECTION DRAWINGS
184.00
174.00
0
4.0
5.00
J2
CH1 V ADJ
HI
PIN CONNECTION
(or LO)
T2 (+)
CH2 V ADJ
EARTH
2
NOT CONNECTED
3
LIVE
4
NOT CONNECTED
5
NEUTRAL
95.00
87.00
T1 (-)
1
J1
CH3 V ADJ
J1
HI
J2
(or LO)
4.00
PIN 1
CH4 V ADJ
WITHOUT GLOBAL OPTION
J3
GLOBAL OPTION
ONLY
PIN
PIN
CONNECTION
CONNECTION
11 0V COMMON
1
0V COMMON
12 0V COMMON
2
0V COMMON
13 CH2 +Ve
3
CH2 +Ve
14 CH2 +Ve
4
CH2 +Ve
15 +SENSE CH1
5
-SENSE CH1
16 +SENSE CH2
6
-SENSE CH2
17 CH1 GOOD
7
N/C
18 CH3 +Ve
8
CH3 +Ve
19 0V COMMON
9
0V COMMON
20 CH4 O/P
10 CH4 O/P
T1 & T2 (SEE TOP LEFT)
J3 (GLOBAL OPTION ONLY)
120.00
112.00
PIN
CONNECTION
1
STANDBY -Ve
PIN
5
CONNECTION
N/C
2
STANDBY +Ve
6
N/C
3
STANDBY -Ve
7
POWER GOOD
4
STANDBY +Ve
8
REM ON/OFF
WITH GLOBAL OPTION
CRIMP PIN
CONNECTOR
HOUSING
J1
39-01-2205
44476-3112
J2
09-50-8051
08-52-0113
J3
51110-0860
T1 & T2
N/A
34.00
28.00
4.00
MATING PARTS (MOLEX OR EQUIVALENT)
20
11
1
7
1
8
2
4.00
10
50394
TAG 19073-0165





Input and output connectors are not included with the product.
They are available from TDK-Lambda
1 off input connector and 3 crimps part number is 94910.
1 off output connector and 20 crimps part number is 94912.
4
NV-300
OUTLINE & CONNECTION DRAWINGS
'U' CHASSIS
(COVER OPTIONAL)
OPEN FRAME
WITHOUT
GLOBAL
OPTION
WITH
GLOBAL
OPTION
FAN+IEC OPTION
FAN OPTION
25.40
18.95
3.00
FAN+IEC OPTION
72.20
20.30
57.20
4.00
31.20
FAN OPTION
102.00
112.00
5.00
19.50
7.50
NARROW CASE
FIXINGS STILL
AVAILABLE IN WIDE
CASE UNITS.
174.00
174.00
7.50
5.00
87.00
184.00
10.00
'U' CHANNEL
39.10
WITHOUT
COVER
127.00
40.60



NV-300


5
TDK-LAMBDA EMEA
www.emea.tdk-lambda.com
TDK-Lambda France SAS
TDK-Lambda UK Ltd.
ZAC des Delaches
CS 41077
9 rue Thuillere
91978 Villebon Courtaboeuf
France
Tel: +33 1 60 12 71 65
Fax: +33 1 60 12 71 66
[email protected]
www.fr.tdk-lambda.com
Kingsley Avenue
Ilfracombe
Devon EX34 8ES
United Kingdom
Tel: +44 (0) 12 71 85 66 66
Fax: +44 (0) 12 71 86 48 94
[email protected]
www.uk.tdk-lambda.com
Italy Sales Office
TDK-Lambda Ltd.
Via dei Lavoratori 128/130
20092 Cinisello Balsamo (MI)
Italy
Tel: +39 02 61 29 38 63
Fax: +39 02 61 29 09 00
[email protected]
www.it.tdk-lambda.com
Kibbutz
Givat Hashlosha 48800
Israel
Tel: +9 723 902 4333
Fax: +9 723 902 4777
[email protected]
www.tdk-lambda.co.il
TDK-Lambda Germany GmbH
Russia
Karl-Bold-Strasse 40
77855 Achern
Germany
Tel: +49 7841 666 0
Fax: +49 7841 5000
[email protected]
www.de.tdk-lambda.com
Technical Support:
St Petersburg
Tel: +7 (812) 6580463
Sales:
Moscow
Tel: +7 (499) 7557732
[email protected]
www.tdk-lambda.ru
Austria Sales Office
Aredstrasse 22
2544 Leobersdorf
Austria
Tel: +43 2256 655 84
Fax: +43 2256 645 12
[email protected]
www.de.tdk-lambda.com
Local Distribution
Distribution:
RSG Electronic Components GmbH ■ Sprendlinger Landstr. 115 ■ D-63069 Offenbach / Germany
Tel. +49.69.984047-0 ■ Fax +49.69.984047-77 ■ [email protected] ■ www.rsg-electronic.de
Änderungen vorbehalten / subject to change without notice.
NV300 69687-REV 10-October 2012
6
NV-300