• Limited Lifetime Warranty • UL508 Approved • SEMI F47 Compliant (high line AC) • Universal Input (85 - 265VAC) • High Efficiency • RoHS Compliant Design Key Market Segments & Applications HWS300-1500 Series Factory Automation Test & Measurement Automated Service Single Output Industrial Power Supplies HWS300-1500 Features and Benefits Features Benefits • Limited Lifetime Warranty • High Efficiency • Wide Range AC Input • Lower Cost of Ownership • Easier System Cooling • Supports Global Use Specifications MODEL ITEMS Input Voltage range (47-63Hz) Input Current (Typ) (1) A Inrush Current (1) Power Factor Temperature Coefficient Overcurrent Protection Overvoltage Protection Hold Up Time (Typ) Leakage Curr. (at 240VAC, 60Hz) Remote Sense Indicator Remote on/off Parallel operation DC Good Remote Adjust (PV) Operating Temperature Storage Temperature Humidity (non condensing) Cooling Withstand Voltage (4) Isolation Resistance Vibration (non operating) Shock Safety Agency Approvals (5) Line Dip Conducted & Radiated EMI Recommended EMI Filter Immunity Weight (Typ) Size Warranty A V ms mA °C °C g mm HWS300 HWS600 HWS1000 HWS1500 85 - 265VAC or 120 - 330VDC 5V: 7.5/3.6; 3.3V: 9.6/5.0; 3.3V: 15/8 12-48V: 8.1/3.9 5-60V: 13.5/7.0 5-60V: 19/10 20 / 40 Meets EN61000-3-2 <0.02%/°C >105% (>101% of peak current for peak current capable models) See table on page 2 (Recycle AC or remote on/off to reset) 20 (HWS1500-7 - 16ms) <0.75mA <1.2mA <1.5mA Yes Green LED = ON Yes (Isolated from output) Single wire connection (up to 5 units) Yes External voltage adjusts output, see options table -10 to +70°C, derate linearly to 50% load from 50 to 70 (2, 3) -30 to +85°C Operating: 10 - 90%RH, Non operating 10 - 95%RH Internal fan Input to Ground 2.5kVAC, Input to Output 3kVAC, Output to Ground 500VAC for 1 min. >100MΩ at 25°C & 70%RH, Output to Ground 500VDC 10 - 55Hz (1 minute sweep), 19.6m/s2 constant X, Y, Z 1 hour < 196.1 m/s2 UL60950-1, CSA60950-1, EN60950-1, EN50178, UL508, CE Mark Complies with SEMI F47 (200VAC line only) EN55011 / EN55022, FCC VCCI (HWS300, 600 & 1000: Class B, HWS1500: Class A) MC1206 MC1210 MC1220 MC1230 IEC61000-4-2, -3, -4, -6 (Level 3), -5, -8 (Level 4), -11 1,000 1,600 3,200 3,800 61 x 82 x 165 100 x 82 x 165 240 x 126.5 x 82 280 x 126.5 x 82 Limited Lifetime Warranty 5V: 3.8/1.9; 12-48V: 4.2/2.1 HWS300-1500 Series 1 Model Selector Model HWS300-3 HWS600-3 HWS1000-3 HWS1500-3 HWS300-5 HWS600-5 HWS1000-5 HWS1500-5 HWS1000-6 HWS1500-6 HWS1000-7 HWS1500-7 HWS300-12 HWS600-12 HWS1000-12 HWS1500-12 HWS300-15 HWS600-15 HWS1000-15 HWS1500-15 HWS300-24 HWS600-24 HWS1000-24 HWS1500-24 HWS1000-36 HWS1500-36 HWS300-48 HWS600-48 HWS1000-48 HWS1500-48 HWS1000-60 HWS1500-60 Voltage V Adjust Range V(3) Max Curr. A Peak Curr. A(2) Max. Pwr. W 3.3V 3.3V 3.3V 3.3V 5V 5V 5V 5V 6V 6V 7.5V 7.5V 12V 12V 12V 12V 15V 15V 15V 15V 24V 24V 24V 24V 36V 36V 48V 48V 48V 48V 60V 60V 2.64 - 3.96 2.64 - 3.96 2.64 - 3.96 2.64 - 3.96 4-6 4-6 4-6 4-6 4.8 - 7.2 4.8 - 7.2 6 - 9V 6 - 9V 9.6 - 14.4 9.6 - 14.4 9.6 - 14.4 9.6 - 14.4 12 - 18 12 - 18 12 - 18 12 - 18 19.2 - 28.8 19.2 - 28.8 19.2 - 28.8 19.2 - 28.8 28.8 - 43.2 28.8 - 43.2 38.4 - 52.8 38.4 - 52.8 38.4 - 52.8 38.4 - 52.8 48 - 66 48 - 66 60 120 200 300 60 120 200 300 167 250 134 200 27 53 88 125 22 43 70 100 14 27 46 65/70 (1) 30.7 42/46.5 (1) 7 13 23 32 18.4 28 - 198 396 660 990 300 600 1000 1500 1002 1500 1005 1500 324 636 1056 1500 330 645 1050 1500 336 648 1104 1560 1104 1512 336 624 1104 1536 1104 1536 - 300 160 240 100 80 16.5 31 58.5 105 39 70 29 23.4 42 Peak Power W 1800 1200 1800 1200 1200 396 744 1404 2520 1404 2520 1404 1404 2520 Load Reg mV Line Reg mV Ripple Noise mV Overvoltage V Eff. typ % (1) 30 30 40 60 30 30 40 60 60 60 60 60 72 72 100 72 90 90 120 90 144 144 150 144 150 150 288 288 300 288 360 360 20 20 20 36 20 20 20 36 36 40 36 40 48 48 48 48 60 60 60 60 96 96 96 96 144 144 192 192 192 192 240 240 120 120 120 150 120 120 120 150 150 150 150 150 150 150 150 150 150 150 150 150 150 150 150 200 200 200 350 350 200 200 400 400 4.13 - 4.95 4.13 - 4.95 4.13 - 4.62 4.12 - 4.62 6.25 -7.25 6.25 -7.25 6.25 - 7 4.0 - 6.0 7.5 - 8.4 4.8 - 7.2 9.38 - 10.5 6.0 - 9.0 15 - 17.4 15 - 17.4 15 - 17.4 15 - 17.4 18.8 - 21.8 18.8 - 21.8 18.8 - 21.8 18.7 - 21.8 30 - 34.8 30 - 34.8 30 - 34.8 30 - 34.8 45 - 49.7 45 - 49.7 55.2 - 64.8 55.2 - 64.8 55.2 - 64.8 55.2 - 64.8 69 - 75 69 - 75 74/77 75/78 71/73 72/75 79/82 80/83 76/78 77/81 79/81 79/82 80/82 81/83 80/83 80/83 82/85 82/85 80/83 81/84 83/85 83/87 82/85 82/85 85/87 84/88 85/88 84/88 82/85 83/86 86/88 86/90 85/88 86/90 Notes (1) 100/200VAC (2) 200-265VAC Input, 10s maximum on time with 35% duty cycle (3) Use program input (PV) to adjust from 20-120% of nominal (20-110% for 48V models) Specification Notes (See Page 1): Options Suffix Description Blank /A HWS300-1500 the cover is fitted as standard Not Applicable HWS300-1500 the cover is fitted as standard HWS300, 600 (Standard on HWS1000 & 1500 all output voltages): 1-6V program voltage input to adjust output 20-120% of nominal (20-110% for 48V) (12V-48V models only for 300 & 600W): See HWS30-1500/HD Datasheet for details. -40 to +71(74)°C operation, conformally coated PCBs See HWS30-1500/ME Datasheet for details. UL60601-1, EN60601-1 medical approvals /PV /HD /ME 2 HWS300-1500 Series (1) 100/200VAC (2) HWS start up -20°C. (-40°C see options table) (3) HWS1000/1500 with 85VAC input: See installation manual HWS1000: -10 to +71°C. HWS1000-5 derate linearly above 40°C (4) 2kVAC HWS1000/1500 Input to ground (5) UL60601-1, EN60601-1, see options. UL508; HWS300/600 5V, 12V, 24V & 48V models Outline Drawing HWS300 -1500 Series HWS300 Notes A: Model name, nominal output voltage and maximum output current are shown in the name plate in accordance with the specifications. B: M4 tapped holes (8) for customer chassis mounting. (Screw penetration depth 6mm maximum.) HWS600 Notes A: Model name, nominal output voltage and maximum output current are shown in the name plate in accordance with the specifications. B: M4 tapped holes (8) for customer chassis mounting. (Screw penetration depth 6mm maximum.) HWS1000 Notes A: Model name, nominal output voltage and maximum output current are shown in the name plate in accordance with the specifications. B: Country of manufacture is shown here. C: M4 tapped holes (16) for customer chassis mounting. (Screws must not protrude into power supply by more than 6mm.) D: I/O Signal Connector. Connector: Matching Housing: Matching Contact: Hand Crimping Tool: S12B-PHDSS(LF)(SN) PHDR-12VS SPHD-002T-P0.5(AWG28~24) SPHD-001T-P0.5(AWG26~22) BPHD-001T-P0.5(AWG26~22) YRS-620(SPHD-002T-P0.5) YC-610R(SPHD-001T-P0.5) YC-610R(BPHD-001T-P0.5) (JST) (JST) (JST) or (JST) or (JST) (JST) (JST) (JST) E: Recommended torque for the terminal piece Input terminal (M4 screw): Output terminal (M8 bolt & nut): Output terminal (M4 screw): 1.27N•m 10.8N•m 1.27N•m HWS1500 Notes A: Model name, option, input voltage range, nominal output voltage, maximum output current are shown in the name plate in accordance with the specifications. B: Country of manufacture is shown here. C: M4 tapped holes (16) for customer chassis mounting. (Screws must not protrude into power supply by more than 6mm.) Recommended M4 screws torque: 1.27N•m D: I/O Signal Connector. Connector: Matching Housing: Matching Contact: Hand Crimping Tool: S12B-PHDSS(LF)(SN) PHDR-12VS SPHD-002T-P0.5(AWG28~24) SPHD-001T-P0.5(AWG26~22) BPHD-001T-P0.5(AWG26~22) YRS-620(SPHD-002T-P0.5) YC-610R(SPHD-001T-P0.5) YC-610R(BPHD-001T-P0.5) (JST) (JST) (JST) or (JST) or (JST) (JST) (JST) (JST) E: Recommended torque for the terminal piece Input terminal (M4 screw): Output terminal (M8 bolt & nut): Output terminal (M4 screw): HWS300-1500 Series 1.27N•m 10.8N•m 1.27N•m 3 TDK-Lambda France SAS TDK-Lambda UK Ltd. Italy Sales Office TDK-Lambda Ltd. ZAC des Delaches CS 41077 9 rue Thuillere 91978 Villebon Courtaboeuf France Tel: +33 1 60 12 71 65 Fax: +33 1 60 12 71 66 [email protected] www.fr.tdk-lambda.com Kingsley Avenue Ilfracombe Devon EX34 8ES United Kingdom Tel: +44 (0) 12 71 85 66 66 Fax: +44 (0) 12 71 86 48 94 [email protected] www.uk.tdk-lambda.com Kibbutz Givat Hashlosha 48800 Israel Tel: +9 723 902 4333 Fax: +9 723 902 4777 [email protected] www.tdk-lambda.co.il Via dei Lavoratori 128/130 20092 Cinisello Balsamo (MI) Italy Tel: +39 02 61 29 38 63 Fax: +39 02 61 29 09 00 [email protected] www.it.tdk-lambda.com Netherlands Russia [email protected] www.tdk-lambda.nl Technical Support: St Petersburg Tel: +7 (812) 6580463 Sales: Moscow [email protected] www.tdk-lambda.ru TDK-Lambda Germany GmbH Karl-Bold-Strasse 40 77855 Achern Germany Tel: +49 7841 666 0 Fax: +49 7841 5000 [email protected] www.de.tdk-lambda.com Local Distribution Austria Sales Office Aredstrasse 22 2544 Leobersdorf Austria Tel: +43 2256 655 84 Fax: +43 2256 645 12 [email protected] www.de.tdk-lambda.com Scandinavia Sales Office Valdemarsgade 7 4100 Ringsted Denmark Tel: +45 24 63 95 65 Fax: +45 69 80 44 99 [email protected] www.emea.tdk-lambda.com Distribution: Bahnhofstrasse 50 8305 Dietlikon Switzerland Tel: +41 44 850 53 53 Fax: +41 44 850 53 50 [email protected] www.de.tdk-lambda.com Änderungen vorbehalten / subject to change without notice. Switzerland Sales Office RSG Electronic Components GmbH Sprendlinger Landstr. 115 D-63069 Offenbach / Germany Tel. +49.69.984047-0 Fax +49.69.984047-77 [email protected] www.rsg-electronic.de www.emea.tdk-lambda.com HWS300-1500 Feb14 v4 4 HWS300-1500 Series Verlängerte Garantie (Limited Lifetime Warranty) TDK-Lambda gewährt für bestimmte Geräteserien eine sogenannte Limited Lifetime Warranty. Diese verlängerte Garantie bezieht sich nur auf Produkte, die von TDK-Lambda als Geräte mit Limited Lifetime Warranty besonders ausgewiesen sind. Diese Geräte erhalten eine verlängerte Garantie bis zu 5 Jahren, nachdem deren Produktion eingestellt und sie vom Markt genommen wurden (Zeitpunkt festgelegt durch TDK-Lambda), jedoch mindestens 10 Jahre ab Verkaufsdatum direkt durch TDK-Lambda oder einen der autorisierten Distributoren an den Endkunden. Der maximal gewährte Garantiezeitraum beträgt 30 Jahre. Vorraussetzung zur Gewähr der Garantie ist der bestimmungsgemäße Einsatz und die Verwendung der Geräte innerhalb der publizierten Spezifikationen auf Grundlage der anwendbaren Normen aus der jeweiligen Gerätezulassung. Ausgenommen von dieser verlängerten Garantie sind Lüfter, Gebläse und andere Komponenten zur Luftumwälzung, sowie Baugruppen daraus. Diese Garantie beschränkt sich auf den direkten Käufer und ist nicht übertragbar. Sowohl TDK-Lambdas Standardgarantie als auch die Lifetime Warranty erlöschen bei Modifikationen, unsachgemäßem Gebrauch oder Reparaturversuchen von Seiten eines Endanwenders, Kunden oder Dritten.