GWS250 - RSG Electronic Components GmbH

• Standby Power Draw < 0.5 Watt
• High Efficiency up to 93%
• Built to meet ErP
• 41 mm height (1U compatible)
• Convection Cooled
• 5V / 300mA Aux Supply
• Output Remote Programming
• Class C Harmonics (IEC 61000-3-2) above 25% Load
• Allows Use in Lighting Equipment
• Five Year Warranty
Key Market Segments & Applications
GWS250 Series
Single Output 250W Power Supplies
Targets all ErP compliant applications
Industrial, Traffic Controls, Automated Service, Kiosks
Test & Measurement, Entertainment Systems,
Communications & Broadcasting, LED Displays & Signage
GWS250 Features and Benefits
Features
Benefits
• Convection Cooling
• Programmable Output Voltage
• Peak Power Capability 120% (24 & 36V models)
• Average Active Efficiency @ 230V : 92.7%
• Easier System Integration, No Audible Noise
• Broad Range of Applications
• Lower Cost, Smaller Size
• Easier System Cooling, Less Energy Used, High Reliability
Specifications
MODEL
ITEMS
AC Input Voltage
Input Frequency
DC Input Voltage
Inrush Current (cold start)
Power Factor
Input Current
Temperature Coefficient
Overcurrent Protection
Overvoltage Protection
Overtemperature Protection
Hold Up Time
Leakage Current (Typ)
Remote Sense
Remote On/Off
Standby Input Power
Aux Supply
Monitoring Signal
LED Indicator
Output Remote Programming
Operating Temperature
Storage Temperature
Operating Humidity
Storage Humidity
Cooling
Withstand Voltage
Isolation Resistance
Vibration (non operating)
Shock (in package)
Immunity
Safety Agency Approvals
Conducted & Radiated EMI
Weight (Typ)
Size (L x W x H)
Warranty
Notes:
(1)
(1)
(2)
(2)
(1)
(3)
VAC
Hz
VDC
A
A
°C
V
ms
mA
W
°C
°C
Ω
g
mm
yrs
GWS250
85 - 264VAC (300VAC for 5s)
47 - 63Hz
120 - 373VDC
20A at 115VAC, 40A at 230VAC
Meets EN61000-3-2 (Typical PF 0.98/0.95) ClassA, Class C> 25% Load
3.0 / 1.4
<0.02%/°C
>105% rated output power or >101% of peak output power
12V: 13.8 - 16.2V, 24V: 30.3 - 35.5V, 36V: 41.4 - 48.6V, 48V: 60 - 69.6V
Yes
16ms
0.75mA@230VAC
No
Active Low
<0.5W
5V/0.3A
DC OK, open collector signal, High on Fail (Active Low)
Green LED = On
See installation manual for details
-25°C to +70°C. (Refer to Output Derating Curve) Guaranteed Start Up at -40°C
-30°C to +85°C
30 - 90% RH (non condensing)
10 - 95% RH (non condensing)
Convection
Input to FG 1.5kVAC (20mA), Input to Output 3kVAC (20mA), output to FG 500VAC (100mA) for 1 min
>100MΩ at 25°C & 70%RH
10 - 55Hz: 19.6m/s2 Constant sweep 1 min X, Y, Z for 1 hour each
< 196.1 m/s2 (20G)
Built to meet EN61000-4-2 (Level 2,3), -3 (Level 3), -4 (Level 3), -5 (Level 4), -6 (Level 3), -8 (Level 4), -11
UL60950-1, CSA C22.2 No.60950-1-07 (2nd Edition), EN60950-1, IEC60950-1 (2nd Edition), CE
Built to meet EN55022-B, CISPR22-B
850
198 x 105 x 41
5
(1) 115 / 230VAC input (2) Recycle AC, or use remote on/off to reset
(3) When remote off and 5V Aux supply @ no load
GWS250 Series
1
Model Selector
Voltage
(V)
Adjust
Range
(V)
Max
Current
(A)
Peak
Current (1)
DC (A)
Load
Reg.
(mV)
Line
Reg.
(mV)
Ripple
Noise
(mV)
Efficiency
(typ) %
(230VAC)
GWS250-12
12V
10.8 - 13.2
21
-
96
48
120
92
GWS250-24
24V
22 - 28.8
10.5
12.5
192
96
150
92
GWS250-36
36V
32 - 40
7
8.4
288
144
200
93
GWS250-48
48V
42 - 57.6
5.3
-
384
192
250
93
Model
Notes:
(1) Peak current 10seconds max. 35% duty cycle max.
Outline Drawing GWS250
NOTES: A. Model name, Input voltage range, Nominal output voltage, Maximum output current & country of manufacture are
shown in accordance with the specification.
B. M4 tapped, embossed & countersunk holes (8) for customer chassis mounting.
Screws must not protrude into power supply by more than 5mm
2
GWS250 Series
T
Output Derating Curve GWS250
Options
120
100
Load (%)
80
Suffix
Description
/T
/RL
/BAT
/P
OTP auto recovery after unit cools down
Remote ON/OFF reverse logic (Active High)
Battery charging for 24V (21 -29V/8.8A) & 48V (42-58V/4.4A) only
Power up to 350W with system airflow of 20cfm minimum and
air blowing in from opposite side of input/output connectors
Without cover
/L
60
Notes:
50
40
GWS250-XX/YYYYYYYYYYYYY where XX can be 12, 24, 36, or 48
Y option can be any combination of P, L, RL, CO, CO2, T, BAT, or blank
T
Options - coming soon
depending on market request; MOQ 500+ may be required
20
0
-25
0
25
50
70
75
100
Ta (°C)
Mounting Options GWS250 - For other mounting versions please refer to Instruction Manual
Provide clearance 15mm or more on top of power supply
Air Flow
Sheet
Metal
!
!
!
!
Mounting Method
1 This is convection cooling type power supply. In consideration of the heat radiation and safety, please keep a distance of more than 15mm between the power supply and the peripheral
parts. When lining up multiple units, please make sure to place them 5mm or more apart from each other
2 Maximum allowable penetration of mounting screws into the power-supply is 5mm
3 Recommended torque for mounting screws (M4): 1.27 Nm (13.0 kgf.cm)
GWS250 Output Voltage External Control (PV)
!
Output Voltage Linearity
Output Voltage Linearity
120%
110%
Nominal
Vout
80%
60%
0
OutputVoltage
Voltage Derating
Output
Derating
24 & 48V Model
12 & 36V Model
48V Model
12~36V Model
6V
3V
4V 5V
5.5V
PV voltage (Nominal Input Voltage)
Output Voltage
Output Voltage
Connection Method
120%
110%
Nominal
Vout
80%
60%
24 & 48V Model
12 & 36V Model
48V Model
12~36V Model
0
83%
100%
90%
Load Current
Output voltage external control function is available. Output voltage can be varied by applying an external voltage (3-6V) to ‘PV’ and ‘COM’ terminals at
signal connector CN1
Please consider the following characteristics.
Notes:
For 12V & 36V output model, limit output voltage variation range at 60% - 110%. At PV voltage variation 3V - 5.5V
For 24V output model, limit output voltage variation range at 60% - 120%. At PV voltage variation 3V - 6V
For 48V output model, limit output voltage variation range at 80% - 120%. At PV voltage variation 4V - 6V
GWS250 Series
3
TDK-LAMBDA EMEA
www.emea.tdk-lambda.com
TDK-Lambda France SAS
TDK-Lambda UK Ltd.
Route de Grivery
ZAC des Delaches
CS 41077
91978 Courtaboeuf Cedex
France
Tel: +33 1 60 12 71 65
Fax: +33 1 60 12 71 66
[email protected]
www.fr.tdk-lambda.com
Kingsley Avenue
Ilfracombe
Devon EX34 8ES
United Kingdom
Tel: +44 (0) 12 71 85 66 66
Fax: +44 (0) 12 71 86 48 94
[email protected]
www.uk.tdk-lambda.com
Italy Sales Office
Nemic Lambda Ltd.
Via dei Lavoratori 128/130
20092 Cinisello Balsamo (MI)
Italy
Tel: +39 02 61 29 38 63
Fax: +39 02 61 29 09 00
[email protected]
www.it.tdk-lambda.com
Kibbutz
Givat Hashlosha 48800
Israel
Tel: +9 723 902 4333
Fax: +9 723 902 4777
[email protected]
www.nemic.co.il
TDK-Lambda Germany GmbH
Russia
Karl-Bold-Strasse 40
77855 Achern
Germany
Tel: +49 7841 666 0
Fax: +49 7841 5000
[email protected]
www.de.tdk-lambda.com
Technical Support:
St Petersburg
Tel: +7 (812) 6580463
Sales:
Moscow
Tel: +7 (499) 7557732
[email protected]
www.tdk-lambda.ru
Austria Sales Office
Aredstrasse 22
2544 Leobersdorf
Austria
Tel: +43 2256 655 84
Fax: +43 2256 645 12
[email protected]
www.de.tdk-lambda.com
LOCAL DISTRIBUTION
Distribution:
RSG Electronic Components GmbH ■ Sprendlinger Landstr. 115 ■ D-63069 Offenbach / Germany
Tel. +49.69.984047-0 ■ Fax +49.69.984047-77 ■ [email protected] ■ www.rsg-electronic.de
Änderungen vorbehalten / subject to change without notice.
GWS 250 July11 v6
4