NV-Power NV-175 www.uk.tdk-lambda.com/nv Medical Test Industrial Broadcast Comms 175/180/200W Configurable ac/dc power supply. Renewable Features Benefits • High Efficiency Minimises heat in system • Low Profile Fits 1U Applications • Dual Fusing Simplifies system design, reduces cost • Temerature controlled fan option Reduces system noise • 3 Year Warranty Low cost of ownership Input 45 - 63Hz Input Voltage 90-264Vac Input Frequency Input Harmonics EN61000-3-2 compliant Power Factor 0.97 typical Input Fuse Fast acting (not user accessible) Inrush Current <40A at 25°C and 230Vac (cold start) Earth Leakage Current 123µA at 120Vac (60Hz), 257µA max at 240Vac (60Hz) Worst case leakage current is less than 300µA at 264Vac, 63Hz (normal condition, 500µA Single Fault Condition) (440Hz with reduced PFC - consult factory) Available Outputs Adjustment Range Channel 1 Adjustment Range Channel 21 1 2 3 0 1.8V / 15A 2.7V / 15A 3.3V / 15A Omit 0.9 - 2.5V 2.5 - 3.3V 2.5 - 3.3V 5V / 25A2 5 - 5.5V T F 12V / 15A 15V / 12A 12 - 15V5 12 - 15V6 5 0 5V / 10A10 Omit 3.3 - 5.5V G 24V / 7.5A 24 - 28V7 5 0 5V / 8A8 Omit 3.3 - 5.5V 5 1. 1.8V, 2.7V, 3.3V channel 2 only available with 5V Channel 1 5V/10A channel 2 only available with 12V or 15V Channel 1 5V/8A channel 2 only available with 24V Channel 1. 2. Maximum combined output current from Ch1 & Ch2 = 25A Models with 5V channel 1 are limited to 175W output power 3. 4. 5. 6. Channel 33 T F G 0 12V / 5A 15V / 5A 24V / 2.5A Omit Adjustment Range 12 - 15V 12 - 15V 18 - 24V Follow letters in red by ‘Y’ for negative output channel 3. Follow letters in red by ‘P’ for positive output channel 4. 12 - 12.5V if 24V channel 3 fitted. 14.5 - 15V if 24V channel 3 fitted Channel 44 T F 3H 5H TH FH 0H 0 -12V / 1A -15V / 1A -3.3V / 2A9 -5V / 2A9 -12V / 2A9 -15V / 2A9 Fan supply only Omit Adjustment Range Fixed Fixed Fixed Fixed Fixed Fixed 7. 24 - 24.5V if 5V channel 2 fitted 24 - 26V if 24V channel 3 fitted. 8. 7A max with ‘-F’ or ‘-I’ option. 9. 1.5A max with ‘-F’ or ‘-I’option. 10. 9A max with ‘-F’ or ‘-I’option. Other output options are available, please contact factory with your requirements Isolation Input to Output 2 x MOOPs (3rd edition 60601) 4.3kVdc Input to Earth 1.5kVac, 2.3kVdc Output to Earth 200Vdc Medical reinforced (2 x MOPPs) version available, contact factory for details. NV-Power NV-175 1 How To Create A Product Description NV1- #o/p Ch1 Ch2 Confirm availability of created product with TDK-Lambda Ch32 Ch43 Global Option Case Option Blank standard, vertical connector Right angled connector -R (see handbook for ‘R’ connection Connector Option and mechanical details) Number of outputs (excluding standby supply) Letter / number from ‘Available Ch1 - Ch4 Outputs’ table to represent output voltage Blank -N -N1 -N2 -N3 -N4 1. Needs 0H, 3H, 5H, TH or FH type channel 4. The fan speed is temperature dependent, ensuring optimum cooling and lowest audible noise. 2. For negative output channel 3, follow chosen letter by ‘Y’. For example, TY channel 3 = -12V / 5A. 3. For positive output channel 4, follow chosen letter by ‘P’. For example, TP channel 4 = +12V / 1A. Blank no case -C U chassis + cover -U U chassis -F End fan + case1 -I End fan + case + IEC inlet1 no option 5V / 2A standby 12V / 1A standby 13.5V / 1A standby 5V / 2A standby, ATX compatible 12V / 1A standby, ATX compatible Output Specification Turn on time Efficiency Hold up Ripple and Noise Voltage Accuracy Remote Sense Minimum Load 1.5s max up to 90% 16ms min <1% ±1% Yes No Total Regulation 1% Transient Response <4% Recovery Over Voltage Protection Short Circuit Protection Over Temperature Protection 500µs Yes Yes Yes Peak Output Power 200W Ch1 Good Signal at 90Vac and 100% rated output power configuration dependent at 90Vac (or 50mV if higher) pk-pk, using EIAJ test method & 20MHz bandwidth ±4% for Channel 4 with ‘T’ or ‘F’ type outputs, +4/-3% for all other channel 4. Channels 1 & 2. Max 0.5V total line drop on any output Including Line (for 90-264Vac input change), Load (for 0-100% load change) and Cross (for 0-100% load change on any other output) regulation. of set voltage for 50% load change (in 50µs within the range 25-100% load) for recovery to 1% of set voltage See Application Notes for details Single output units with 12V, 15V or 24V (T, F or G). Average output power must not exceed 180W over any 5 minute period Provides a Logic ‘Low’ signal after Channel 1 output is within 90% (±5%) of nominal Yes QUICK SELECTOR - example configurations Model Ch1 Ch1 Ch4 Ch5 Global Option NV1-1T000 12V / 15A - - - - No NV1-1G000 24V / 7.5A - - - - No NV1-453TT 5V / 25A 3.3V / 15A 12V / 5A -12V / 1A - No NV1-453TT-N3 5V / 25A 3.3V / 15A 12V / 5A -12V / 1A 5V / 2A ATX (-N3) NV1-453FF 5V / 25A 3.3V / 15A 15V / 5A -15V / 1A - No NV1-453FF-N3 5V / 25A 3.3V / 15A 15V / 5A -15V / 1A 5V / 2A ATX (-N3) NV1-4G5TT 24V / 7.5A 5V / 8A 12V / 5A -12V / 1A - No NV1-4G5TT-N3 24V / 7.5A 5V / 8A 12V / 5A -12V / 1A 5V / 2A ATX (-N3) NV1-4G5FF 24V / 7.5A 5V / 8A 15V / 5A -15V / 1A - No NV1-4G5FF-N3 24V / 7.5A 5V / 8A 15V / 5A -15V / 1A 5V / 2A ATX (-N3) Additional variants available ‘Built to Order’ - see ‘How to create a product description’ 2 Ch3 NV-Power NV-175 Global Signals (-N, -N1 and -N2 option models) Global Signals (-N3 and -N4 option models) Remote on/off TTL logic level high inhibits all outputs (except Standby) ATX Remote on/off TTL logic level high or open circuit inhibits all outputs (except Standby) Power Good Open collector output (referenced to PSU 0V). Turns on to indicate ac supply is good and output 1 is within regulation. ATX Power Good Logic high indicates ac supply is good and output 1 is within regulation. Standby Supply Isolated supply, not affected by remote on/off -N option = 5V / 2A (2.5A peak) -N1 Option = 12V / 1A -N2 Option = 13.5V / 1A Standby Supply Common 0V with power supply. Not affected by ATX remote on/off -N3 option = 5V / 2A -N4 Option = 12V / 1A Immunity EN61000-6-2:2005, EN60601-1-2:2001 Criteria Electrostatic Discharge EN61000-4-2 Level 4 Air discharge 15kV, Contact discharge 8kV. Not applicable to open frame units Electromagnetic Field EN61000-4-3 Level 3 12V/m A A A Fast / Burst Transient EN61000-4-4 Level 4 ac input tested to 4.4kV dc output tested to 2.2kV Surge Immunity EN61000-4-5 Level 3 Common mode - 2.2kV, Differential - 1.1kV A Conducted RF Immunity EN61000-4-6 Level 3 12V A Power Frequency Magnetic Field EN61000-4-8 Level 4 30A/m A Voltage Dips, Variations, Interruptions EN61000-4-11 Class 3 Criteria B for 5 sec interruption A Emissions EN61000-6-3:2007, EN60601-1-2:2001 Radiated Electric Field EN55011, EN55022 (as per CISPR.11/22) Class B, FCC47 part 15 subpart B Conducted Emissions EN55011, EN55022 (as per CISPR.11/22) Class B, FCC47 part 15 subpart B Conducted Harmonics EN61000-3-2 Class A Flicker EN61000-3-3 Compliant - dmax only see application note for details. Additional filtering is required for IEC inlet version Environment Temperature 0°C to 50°C operational, -40°C to 70°C storage (max 12 months). Full load, with either ‘-F’ option fitted or 2m/s air blown from input to output (approximately 10CFM) Derating 50°C to 70°C derate each output by 2.5% per °C Low Temp Startup -20°C Humidity 5 - 95% RH non condensing Shock ±3 x 30g shocks in each plane, total 18 shocks 30g shock = 11ms (+/-0.5msec), half sine Conforms to EN60068-2-27, EN60068-2-47, IEC68-2-27, IEC68-2-47, JIS C0041-1987. Conforms to MIL-STD-810E/F, Method 516.5, Pro I, IV, VI Vibration Single axis 10 - 500 Hz at 2g (sweep and endurance at resonance) in all 3 planes Conforms to EN60068-2-6, IEC68-2-6 Conforms to MIL-STD-810E, Method 514.4, Pro I, Cat 1,9 Altitude 3000 metres operational Pollution Degree 2, Material group IIIb Safety Approvals Notes IEC/EN 60950-1, UL60950-1 / CSA 22.2 No 60950-1 File E135494 IEC/EN 60601-1, UL/CSA 60601-1, ANSI/AAMI ES60601-1 CAN/CSA-C22.2 No 60601-1-08 File E349607 IEC/EN61010 Designed to meet CE Mark (EN60950-1) LV Directive 2006/95/EC CB certificate and Report available on request Please check with technical sales for status of approvals NV-Power NV-175 3 Outline & Connection Drawings Top View NV175 models without cover Top View NV175-N & NV175-Nx models without cover Input and output connectors are not included with the product. They are available from TDK-Lambda Part Number Contents 94910 1 off input connector and 3 crimps 94911 1 off output connector and 24 crimps Side View NV175 models without cover or chassis Notes: 1. All customer fixings M3 4 End View 2. Maximum thread penetration 4.5mm 3. Maximum torque 0.9Nm NV-Power NV-175 4. All tolerances +/-0.5mm Outline & Connection Drawings Top View Top View NV175-C models NV175-N-C & NV175-Nx-C models Side View Side View NV175-C & NV175-U models NV175-N-C, NV175-Nx-C, NV175-N-U & NV175-Nx-U models Bottom View Bottom View NV175-N-C, NV175-Nx-C, NV175-N-U & NV175-Nx-U models NV175-C & NV175-U models NV-175 units with fan (-F or -I) Top View Top View Side View Side View Bottom View Bottom View Other dimensions same as cases without fans (above) Notes: 1. All customer fixings M3 2. Maximum thread penetration 4.5mm 3. Maximum torque 0.9Nm NV-Power NV-175 4. All tolerances +/-0.5mm 5 TDK-LAMBDA EMEA www.emea.tdk-lambda.com TDK-Lambda France SAS TDK-Lambda UK Ltd. ZAC des Delaches CS 41077 9 rue Thuillere 91978 Villebon Courtaboeuf France Tel: +33 1 60 12 71 65 Fax: +33 1 60 12 71 66 [email protected] www.fr.tdk-lambda.com Kingsley Avenue Ilfracombe Devon EX34 8ES United Kingdom Tel: +44 (0) 12 71 85 66 66 Fax: +44 (0) 12 71 86 48 94 [email protected] www.uk.tdk-lambda.com Italy Sales Office TDK-Lambda Ltd. Via dei Lavoratori 128/130 20092 Cinisello Balsamo (MI) Italy Tel: +39 02 61 29 38 63 Fax: +39 02 61 29 09 00 [email protected] www.it.tdk-lambda.com Kibbutz Givat Hashlosha 48800 Israel Tel: +9 723 902 4333 Fax: +9 723 902 4777 [email protected] www.tdk-lambda.co.il TDK-Lambda Germany GmbH Russia Karl-Bold-Strasse 40 77855 Achern Germany Tel: +49 7841 666 0 Fax: +49 7841 5000 [email protected] www.de.tdk-lambda.com Technical Support: St Petersburg Tel: +7 (812) 6580463 Sales: Moscow Tel: +7 (499) 7557732 [email protected] www.tdk-lambda.ru Austria Sales Office Aredstrasse 22 2544 Leobersdorf Austria Tel: +43 2256 655 84 Fax: +43 2256 645 12 [email protected] www.de.tdk-lambda.com Local Distribution Distribution: RSG Electronic Components GmbH ■ Sprendlinger Landstr. 115 ■ D-63069 Offenbach / Germany Tel. +49.69.984047-0 ■ Fax +49.69.984047-77 ■ [email protected] ■ www.rsg-electronic.de Änderungen vorbehalten / subject to change without notice. NV175 69530-Rev 23-October 2012 6 NV-Power NV-175