NV-Power NV1 - RSG Electronic Components GmbH

NV-Power NV-175
www.uk.tdk-lambda.com/nv
Medical
Test
Industrial
Broadcast
Comms
175/180/200W Configurable
ac/dc power supply.
Renewable
Features
Benefits
• High Efficiency
Minimises heat in system
• Low Profile
Fits 1U Applications
• Dual Fusing
Simplifies system design, reduces cost
• Temerature controlled fan option
Reduces system noise
• 3 Year Warranty
Low cost of ownership
Input
45 - 63Hz
Input Voltage
90-264Vac
Input Frequency
Input Harmonics
EN61000-3-2 compliant
Power Factor
0.97 typical
Input Fuse
Fast acting (not user accessible)
Inrush Current
<40A at 25°C and 230Vac (cold start)
Earth Leakage
Current
123µA at 120Vac (60Hz), 257µA max at 240Vac (60Hz)
Worst case leakage current is less than 300µA at 264Vac, 63Hz (normal condition, 500µA Single Fault Condition)
(440Hz with reduced PFC - consult factory)
Available Outputs
Adjustment
Range
Channel 1
Adjustment
Range
Channel 21
1
2
3
0
1.8V / 15A
2.7V / 15A
3.3V / 15A
Omit
0.9 - 2.5V
2.5 - 3.3V
2.5 - 3.3V
5V / 25A2
5 - 5.5V
T
F
12V / 15A
15V / 12A
12 - 15V5
12 - 15V6
5
0
5V / 10A10
Omit
3.3 - 5.5V
G
24V / 7.5A
24 - 28V7
5
0
5V / 8A8
Omit
3.3 - 5.5V
5
1. 1.8V, 2.7V, 3.3V channel 2 only available with 5V Channel 1
5V/10A channel 2 only available with 12V or 15V Channel 1
5V/8A channel 2 only available with 24V Channel 1.
2. Maximum combined output current from Ch1 & Ch2 = 25A
Models with 5V channel 1 are limited to 175W output power
3.
4.
5.
6.
Channel 33
T
F
G
0
12V / 5A
15V / 5A
24V / 2.5A
Omit
Adjustment
Range
12 - 15V
12 - 15V
18 - 24V
Follow letters in red by ‘Y’ for negative output channel 3.
Follow letters in red by ‘P’ for positive output channel 4.
12 - 12.5V if 24V channel 3 fitted.
14.5 - 15V if 24V channel 3 fitted
Channel 44
T
F
3H
5H
TH
FH
0H
0
-12V / 1A
-15V / 1A
-3.3V / 2A9
-5V / 2A9
-12V / 2A9
-15V / 2A9
Fan supply only
Omit
Adjustment
Range
Fixed
Fixed
Fixed
Fixed
Fixed
Fixed
7. 24 - 24.5V if 5V channel 2 fitted
24 - 26V if 24V channel 3 fitted.
8. 7A max with ‘-F’ or ‘-I’ option.
9. 1.5A max with ‘-F’ or ‘-I’option.
10. 9A max with ‘-F’ or ‘-I’option.
Other output options are available, please contact factory with your requirements
Isolation
Input to Output
2 x MOOPs (3rd edition 60601)
4.3kVdc
Input to Earth
1.5kVac, 2.3kVdc
Output to Earth
200Vdc
Medical reinforced (2 x MOPPs) version available, contact factory for details.
NV-Power NV-175
1
How To Create A Product Description
NV1-
#o/p
Ch1
Ch2
Confirm availability of created product with TDK-Lambda
Ch32
Ch43
Global
Option
Case
Option
Blank standard, vertical connector
Right angled connector
-R (see handbook for ‘R’ connection
Connector
Option
and mechanical details)
Number of outputs
(excluding standby supply)
Letter / number from ‘Available
Ch1 - Ch4 Outputs’ table to represent
output voltage
Blank
-N
-N1
-N2
-N3
-N4
1. Needs 0H, 3H, 5H, TH or FH type channel 4.
The fan speed is temperature dependent, ensuring optimum cooling and lowest audible noise.
2. For negative output channel 3, follow chosen letter by ‘Y’. For example, TY channel 3 = -12V / 5A.
3. For positive output channel 4, follow chosen letter by ‘P’. For example, TP channel 4 = +12V / 1A.
Blank no case
-C U chassis + cover
-U U chassis
-F End fan + case1
-I End fan + case + IEC inlet1
no option
5V / 2A standby
12V / 1A standby
13.5V / 1A standby
5V / 2A standby, ATX compatible
12V / 1A standby, ATX compatible
Output Specification
Turn on time
Efficiency
Hold up
Ripple and Noise
Voltage Accuracy
Remote Sense
Minimum Load
1.5s max
up to 90%
16ms min
<1%
±1%
Yes
No
Total Regulation
1%
Transient Response
<4%
Recovery
Over Voltage Protection
Short Circuit Protection
Over Temperature Protection
500µs
Yes
Yes
Yes
Peak Output Power
200W
Ch1 Good Signal
at 90Vac and 100% rated output power
configuration dependent
at 90Vac
(or 50mV if higher) pk-pk, using EIAJ test method & 20MHz bandwidth
±4% for Channel 4 with ‘T’ or ‘F’ type outputs, +4/-3% for all other channel 4.
Channels 1 & 2. Max 0.5V total line drop
on any output
Including Line (for 90-264Vac input change), Load (for 0-100% load change) and
Cross (for 0-100% load change on any other output) regulation.
of set voltage for 50% load change
(in 50µs within the range 25-100% load)
for recovery to 1% of set voltage
See Application Notes for details
Single output units with 12V, 15V or 24V (T, F or G). Average output power must not
exceed 180W over any 5 minute period
Provides a Logic ‘Low’ signal after Channel 1 output is within 90% (±5%) of nominal
Yes
QUICK SELECTOR - example configurations
Model
Ch1
Ch1
Ch4
Ch5
Global Option
NV1-1T000
12V / 15A
-
-
-
-
No
NV1-1G000
24V / 7.5A
-
-
-
-
No
NV1-453TT
5V / 25A
3.3V / 15A
12V / 5A
-12V / 1A
-
No
NV1-453TT-N3
5V / 25A
3.3V / 15A
12V / 5A
-12V / 1A
5V / 2A
ATX (-N3)
NV1-453FF
5V / 25A
3.3V / 15A
15V / 5A
-15V / 1A
-
No
NV1-453FF-N3
5V / 25A
3.3V / 15A
15V / 5A
-15V / 1A
5V / 2A
ATX (-N3)
NV1-4G5TT
24V / 7.5A
5V / 8A
12V / 5A
-12V / 1A
-
No
NV1-4G5TT-N3
24V / 7.5A
5V / 8A
12V / 5A
-12V / 1A
5V / 2A
ATX (-N3)
NV1-4G5FF
24V / 7.5A
5V / 8A
15V / 5A
-15V / 1A
-
No
NV1-4G5FF-N3
24V / 7.5A
5V / 8A
15V / 5A
-15V / 1A
5V / 2A
ATX (-N3)
Additional variants available ‘Built to Order’ - see ‘How to create a product description’
2
Ch3
NV-Power NV-175
Global Signals (-N, -N1 and -N2 option models)
Global Signals (-N3 and -N4 option models)
Remote on/off
TTL logic level high inhibits all outputs (except
Standby)
ATX Remote
on/off
TTL logic level high or open circuit inhibits all
outputs (except Standby)
Power Good
Open collector output (referenced to PSU 0V).
Turns on to indicate ac supply is good and output 1
is within regulation.
ATX Power
Good
Logic high indicates ac supply is good and output 1
is within regulation.
Standby Supply
Isolated supply, not affected by remote on/off
-N option = 5V / 2A (2.5A peak)
-N1 Option = 12V / 1A
-N2 Option = 13.5V / 1A
Standby Supply
Common 0V with power supply. Not affected by ATX
remote on/off
-N3 option = 5V / 2A
-N4 Option = 12V / 1A
Immunity EN61000-6-2:2005, EN60601-1-2:2001
Criteria
Electrostatic Discharge
EN61000-4-2
Level 4
Air discharge 15kV, Contact discharge 8kV. Not applicable to open
frame units
Electromagnetic Field
EN61000-4-3
Level 3
12V/m
A
A
A
Fast / Burst Transient
EN61000-4-4
Level 4
ac input tested to 4.4kV
dc output tested to 2.2kV
Surge Immunity
EN61000-4-5
Level 3
Common mode - 2.2kV, Differential - 1.1kV
A
Conducted RF Immunity
EN61000-4-6
Level 3
12V
A
Power Frequency Magnetic Field
EN61000-4-8
Level 4
30A/m
A
Voltage Dips, Variations, Interruptions
EN61000-4-11
Class 3
Criteria B for 5 sec interruption
A
Emissions EN61000-6-3:2007, EN60601-1-2:2001
Radiated Electric Field
EN55011, EN55022
(as per CISPR.11/22) Class B, FCC47 part 15 subpart B
Conducted Emissions
EN55011, EN55022
(as per CISPR.11/22) Class B, FCC47 part 15 subpart B
Conducted Harmonics
EN61000-3-2
Class A
Flicker
EN61000-3-3
Compliant - dmax only
see application note for details. Additional filtering is required for IEC inlet version
Environment
Temperature
0°C to 50°C operational, -40°C to 70°C storage (max 12 months).
Full load, with either ‘-F’ option fitted or 2m/s air blown from input to output (approximately 10CFM)
Derating
50°C to 70°C derate each output by 2.5% per °C
Low Temp Startup
-20°C
Humidity
5 - 95% RH non condensing
Shock
±3 x 30g shocks in each plane, total 18 shocks
30g shock = 11ms (+/-0.5msec), half sine
Conforms to EN60068-2-27, EN60068-2-47, IEC68-2-27, IEC68-2-47, JIS C0041-1987.
Conforms to MIL-STD-810E/F, Method 516.5, Pro I, IV, VI
Vibration
Single axis 10 - 500 Hz at 2g (sweep and endurance at resonance) in all 3 planes
Conforms to EN60068-2-6, IEC68-2-6
Conforms to MIL-STD-810E, Method 514.4, Pro I, Cat 1,9
Altitude
3000 metres operational
Pollution
Degree 2, Material group IIIb
Safety Approvals
Notes
IEC/EN 60950-1, UL60950-1 / CSA 22.2 No 60950-1
File E135494
IEC/EN 60601-1, UL/CSA 60601-1, ANSI/AAMI ES60601-1
CAN/CSA-C22.2 No 60601-1-08
File E349607
IEC/EN61010
Designed to meet
CE Mark (EN60950-1)
LV Directive 2006/95/EC
CB certificate and Report available on request
Please check with technical sales for status of approvals
NV-Power NV-175
3
Outline & Connection Drawings
Top View
NV175 models
without cover
Top View
NV175-N & NV175-Nx
models without cover
Input and output connectors are not included
with the product. They are available from
TDK-Lambda
Part
Number
Contents
94910
1 off input connector and 3 crimps
94911
1 off output connector and 24 crimps
Side View
NV175 models without cover
or chassis
Notes: 1. All customer fixings M3
4
End View
2. Maximum thread penetration 4.5mm
3. Maximum torque 0.9Nm
NV-Power NV-175
4. All tolerances +/-0.5mm
Outline & Connection Drawings
Top View
Top View
NV175-C models
NV175-N-C & NV175-Nx-C
models
Side View
Side View
NV175-C & NV175-U models
NV175-N-C, NV175-Nx-C, NV175-N-U
& NV175-Nx-U models
Bottom View
Bottom View
NV175-N-C, NV175-Nx-C, NV175-N-U &
NV175-Nx-U models
NV175-C & NV175-U models
NV-175 units with fan (-F or -I)
Top View
Top View
Side View
Side View
Bottom View
Bottom View
Other dimensions same as cases without fans (above)
Notes: 1. All customer fixings M3
2. Maximum thread penetration 4.5mm
3. Maximum torque 0.9Nm
NV-Power NV-175
4. All tolerances +/-0.5mm
5
TDK-LAMBDA EMEA
www.emea.tdk-lambda.com
TDK-Lambda France SAS
TDK-Lambda UK Ltd.
ZAC des Delaches
CS 41077
9 rue Thuillere
91978 Villebon Courtaboeuf
France
Tel: +33 1 60 12 71 65
Fax: +33 1 60 12 71 66
[email protected]
www.fr.tdk-lambda.com
Kingsley Avenue
Ilfracombe
Devon EX34 8ES
United Kingdom
Tel: +44 (0) 12 71 85 66 66
Fax: +44 (0) 12 71 86 48 94
[email protected]
www.uk.tdk-lambda.com
Italy Sales Office
TDK-Lambda Ltd.
Via dei Lavoratori 128/130
20092 Cinisello Balsamo (MI)
Italy
Tel: +39 02 61 29 38 63
Fax: +39 02 61 29 09 00
[email protected]
www.it.tdk-lambda.com
Kibbutz
Givat Hashlosha 48800
Israel
Tel: +9 723 902 4333
Fax: +9 723 902 4777
[email protected]
www.tdk-lambda.co.il
TDK-Lambda Germany GmbH
Russia
Karl-Bold-Strasse 40
77855 Achern
Germany
Tel: +49 7841 666 0
Fax: +49 7841 5000
[email protected]
www.de.tdk-lambda.com
Technical Support:
St Petersburg
Tel: +7 (812) 6580463
Sales:
Moscow
Tel: +7 (499) 7557732
[email protected]
www.tdk-lambda.ru
Austria Sales Office
Aredstrasse 22
2544 Leobersdorf
Austria
Tel: +43 2256 655 84
Fax: +43 2256 645 12
[email protected]
www.de.tdk-lambda.com
Local Distribution
Distribution:
RSG Electronic Components GmbH ■ Sprendlinger Landstr. 115 ■ D-63069 Offenbach / Germany
Tel. +49.69.984047-0 ■ Fax +49.69.984047-77 ■ [email protected] ■ www.rsg-electronic.de
Änderungen vorbehalten / subject to change without notice.
NV175 69530-Rev 23-October 2012
6
NV-Power NV-175