PH320240T-009-IQ - Scancraft Display is

TECH. CORP.
SPECIFICATIONS
CUSTOMER
:
PTC
SAMPLE
CODE
:
PS320240T-009-I-02
MASS PRODUCTION CODE
:
PH320240T-009-I-Q
SAMPLE VERSION
:
01
SPECIFICATIONS EDITION
:
003
DRAWING NO.
(Ver.)
:
LMD- PH320240T-009-I-Q (Ver:002)
PACKAGING NO.
(Ver.)
:
PKG- PH320240T-009-I-Q (Ver:001)
Customer Approved
Date:
Approved
Checked
Designer
廖志豪
Rex Liao
張慶源
Yuan Chang
林榮鍾
Timter Lin
POWERTIP
2010.12.21
□
Preliminary specification for design input
■
Specification for sample approval
TW RD APR
POWERTIP TECH. CORP.
Headquarters:
th
No.8, 6 Road, Taichung Industrial Park,
TEL: 886-4-2355-8168
E-mail: [email protected]
FAX: 886-4-2355-8166
Http://www.powertip.com.tw
Taichung, Taiwan
台中市 407 工業區六路 8 號
NO.PT-A-005-8
History of Version
Date
(mm / dd / yyyy)
Ver. Edi.
Description
Page
Design by
05/07/2007
─
0
MASS PRODUCTION
─
Peter
06/22/2007
─
A
Modify B/L Connector number
─
Peter
6
9
Appendix
Jared
Appendix
Timter
08/18/2008
01
001
1.Modify Average Brightness.
2.Modify Power Dissipation of B/L
3. Modify Backlight Tolerances.
02/03/2009
01
002
Modify LCD V.A. dim
01
Modify 1.5 Optical Characteristics
Modify 3.2. Inspection Specification
003
Modify 4. RELIABILITY TEST
Modify 5. PRECAUTION RELATING PRODUCT
HANDLING
12/16/2010
6
19
26
27
Timter
Total︰27 Page
PH320240T-009-I-Q
Page2
SAMPLE Ver.01
SPEC Edi.003
Contents
1. SPECIFICATIONS
1.1
1.2
1.3
1.4
1.5
1.6
Features
Mechanical Specifications
Absolute Maximum Ratings
DC Electrical Characteristics
Optical Characteristics
Backlight Characteristics
2. MODULE STRUCTURE
2.1
2.2
2.3
2.4
Counter Drawing
Interface Pin Description
Timing Characteristics
JUMPER(Setting different use)
3. QUALITY ASSURANCE SYSTEM
3.1
3.2
Quality Assurance Flow Chart
Inspection Specification
4. RELIABILITY TEST
4.1
Reliability Test Condition
5. PRECAUTION RELATING PRODUCT HANDLING
5.1 Safety
5.2 Handling
5.3 Storage
5.4 Terms of Warranty
Appendix:LCM Drawing
Packaging
Note : For detailed information please refer to IC data sheet :
Primacy(TFT LCD): Himax: HX8218-A + HX8615A(Or compatible IC )
PH320240T-009-I-Q
Page3
SAMPLE Ver.01
SPEC Edi.003
1. SPECIFICATIONS
1.1
Features
Main LCD panel
Item
Standard Value
Display Type
320(R、G、B) * 240 Dots
LCD Type
Normally white, Transmissive type
Screen size (inch)
5.7 inch
Viewing Direction
6 O’clock
Color configuration
RGB-Strip
Backlight
LED
Interface
Digital 24-bits RGB
Other (controller/driver IC)
320(R、G、B) * 240 Dots
ROHS
THIS PRODUCT CONFORMS THE ROHS OF PTC
Detail information please refer web side︰
http://www.powertip.com.tw/news.php?area_id_view=1085560481/
1.2
Mechanical Specifications
Item
Standard Value
Unit
Outline Dimension
159.4 (W) * 111.0 (L) * 9.0 (H)
mm
Item
Standard Value
Unit
Viewing Area
116.2 (W) * 87.4 (L)
mm
Active Area
115.2 (W) * 86.4 (L)
mm
LCD panel
Note︰For detailed information please refer to LCM drawing
PH320240T-009-I-Q
Page4
SAMPLE Ver.01
SPEC Edi.003
1.3
Absolute Maximum Ratings
Module
1.4
Item
Symbol
Condition
Min.
Max.
Unit
System Power Supply Voltage
VDD
AVSS=0
-0.3
7.0
V
Input Voltage
Vi
—
-0.3
VDD+0.3
V
Operating Temperature
TOP
—
-20
70
°C
Storage Temperature
TST
—
-30
80
°C
DC Electrical Characteristics
GND = 0V, Ta = 25°C
Module
Item
Power Supply Voltage1
Supply Current
Symbol
Condition
Min.
Typ.
VDD
—
3.0
3.3
3.6
V
VDD = 3.3 V
Pattern=full display
—
90
—
mA
VDD = 3.3 V
Pattern= black *1
—
95
140
mA
IDD
Max. Unit
Note1︰Maximum current display
PH320240T-009-I-Q
Page5
SAMPLE Ver.01
SPEC Edi.003
1.5
Optical Characteristics
VDD= 3.3V, Ta=25°C
TFT LCD Module
Item
Symbol
Condition
Min.
Typ.
Max.
Tr
Tf
θY+
θYθXθX+
Ta = 25°C
θX, θY = 0°
—
—
—
—
—
—
15
35
50
60
60
60
30
50
—
—
—
—
Ta = 25°C
θX , θY = 0°
—
150
250
—
Note 3
X
Y
X
Y
X
Y
X
Y
Ta = 25°C
θX , θY = 0°
0.277
0.289
0.579
0.311
0.299
0.524
0.093
0.040
0.327
0.339
0.629
0.361
0.349
0.574
0.143
0.090
0.377
0.389
0.679
0.411
0.399
0.624
0.193
0.140
—
Note1
Average Brightness
Pattern=white display
(With B/L)
IV
IF=200mA
250
300
—
Uniformity
(With B/L)
△B
IF=200mA
70
—
—
Response time
Viewing angle
Rise
Fall
Top
Bottom
Left
Right
Contrast ratio
CR
White
Color of CIE
Coordinate
(With B/L)
Red
Green
Blue
PH320240T-009-I-Q
CR ≥ 10
Page6
Unit
—
ms
Note 2
Deg. Note 4
cd/m2 Note1
%
Note1
SAMPLE Ver.01
SPEC Edi.003
Note 1:
*1:△B=B(min) / B(max) * 100%
*2:Measurement Condition for Optical Characteristics:
a:Environment: 25℃±5℃ / 60±20%R.H,no wind,dark room below 10 Lux at typical lamp
current and typical operating frequency.
b:Measurement Distance: 500 ± 50 ㎜ ,(θ= 0°)
c:Equipment: TOPCON BM-7 fast,(field 1°),after 10 minutes operation.
d:The uncertainty of the C.I.E coordinate measurement ±0.01,Average Brightness ± 4%
1
2
3
VIEW AREA
6
5
4
7
8
θθ
9
500 ㎜
LCM
Colorimeter=BM-7 fast
To be measured at the center area of panel with a viewing cone of 1° by Topcon
luminance meter BM-7, after 10 minutes operation (module)
Note2: Definition of response time:
The output signals of photo detector are measured when the input signals are changed
from “black” to “white”(falling time) and from “white” to “black”(rising time), respectively.
The response time is defined as the time interval between the 10% and 90% of
Amplitudes.
Refer to figure as below:
Normally White
"White"
"Black"
"White"
Signal (Relative value)
100%
90%
10%
0%
Tr
PH320240T-009-I-Q
Tf
Page7
SAMPLE Ver.01
SPEC Edi.003
Normally Black
"Black"
"White"
"Black"
Signal (Relative value)
100%
90%
10%
0%
Tr
Tf
Note3: Definition of contrast ratio:
Contrast ratio is calculated with the following formula
Photo detector output when LCD is at “White” state
Contrast ratio (CR) =
Photo detector output when LCD is at “Black” state
Note4: Definition of viewing angle:
Refer to figure as below:
θX = θY = 0 °
12H
Φ = 180 °
Φ = 270 °
θY -
θY +
θY + = 9 0 °
θX - = 9 0 °
Y+
X-
θX θX +
Φ= 90 °
Φ
X+
Y6 H
Φ= 0 °
θY - = 9 0 °
PH320240T-009-I-Q
θX + = 9 0 °
Page8
SAMPLE Ver.01
SPEC Edi.003
1.6
Backlight Characteristics
Maximum Ratings
Item
Symbol
Conditions
Min.
Max.
Unit
Forward Current
IF
Ta =25℃
—
200
mA
Reverse Voltage
VR
Ta =25℃
—
10
V
LED Power Dissipation
PDLED
—
0.12
W
Power Dissipation
PD
—
2.4
W
Ta =25℃
/ 20mA
Ta =25℃
Electrical / Optical Characteristics
Item
Symbol
Forward Voltage
VF
Average Brightness
(Without LCD)
IF= 200 mA
IV
Color
PH320240T-009-I-Q
Conditions
Min.
Typ.
Max.
Unit
6.0
6.8
8.5
V
3800
4500
—
cd/m2
White
Page9
SAMPLE Ver.01
SPEC Edi.003
2. MODULE STRUCTURE
2.1
Counter Drawing
2.1.1
LCM Mechanical Diagram
* See Appendix
2.1.2
Block Diagram
PH320240T-009-I-Q
Page10
SAMPLE Ver.01
SPEC Edi.003
2.2
Interface Pin Description
Pin No.
Symbol
1
VDD
2
VDD
3
VDD
4
VDD
5
VSYNC
Vertical sync input
6
ENB
Data enable control
7
VSS
Ground
8
DCLK
9
VSS
10
HSYNC
11
B7
data bit B7
12
B6
data bit B6
13
B5
data bit B5
14
B4
data bit B4
15
B3
data bit B3
16
B2
data bit B2
17
B1
data bit B1
18
B0
data bit B0
19
G7
data bit G7
20
G6
data bit G6
21
G5
data bit G5
22
G4
data bit G4
23
G3
data bit G3
24
G2
data bit G2
25
G1
data bit G1
26
G0
data bit G0
PH320240T-009-I-Q
Function
Analog power.
Dot data clock
Ground
Horizontal sync input
Page11
SAMPLE Ver.01
SPEC Edi.003
Interface Pin Description(CONT.)
27
R7
data bit R7
28
R6
data bit R6
29
R5
data bit R5
30
R4
data bit R4
31
R3
data bit R3
32
R2
data bit R2
33
R1
data bit R1
34
R0
data bit R0
35
VSS
Ground
36
VSS
Ground
37
NC
No use.
38
NC
No use.
39
NC
No use.
40
NC
No use.
Backlight Pin Description
1
A
2
NC
3
K
PH320240T-009-I-Q
Power supply for LED Backlight anode input.
No use.
Power supply for LED Backlight cathode input.
Page12
SAMPLE Ver.01
SPEC Edi.003
2.3 Timing Characteristics
Signal
Dclk
Data
Hsync
Item
Symbol
Frequency
Dclk
6.4
MHz
High Time
Tch
78
ns
Low Time
Tcl
78
ns
Setup Time
Tds
12
ns
Hold Time
Tdh
12
ns
Period
TH
408
DCLK
Pulse Width
Thp
DCLK
Back-Porch
Thb
30
38
Display Period
Thd
320
DCLK
Front-Porch
Thf
20
DCLK
Period
NTSC
PAL
Back-Porch
Display Period
Front-Porch
1
3
NTSC
5
TH
TH
240
TH
4.5
Tvf
PAL
TH
23
Tvd
Unit
DCLK
15
Tvb
PAL
Max.
312.5
Tvp
NTSC
Typ.
262.5
Tv
Pulse Width
Vsync
Min.
TH
46.5
TCLK
TCH
TCL
2.64V
DCLK
0.66V
TDS
TDH
2.64V
DATA
PH320240T-009-I-Q
0.66V
Page13
SAMPLE Ver.01
SPEC Edi.003
DCLK
DATA(R)
Blacking Data
R0
R1
R2
R3
R4
R5
DATA(G)
Blacking Data
G0
G1
G2
G3
G4
G5
Blacking Data
B0
B1
B2
B3
B4
B5
DATA(B)
ENB
TV
VSYNC
TVP
TVB
TVD
TVF
HSYNC
TH
HSYNC
TCLK
THP
DCLK
THB
DATA
PH320240T-009-I-Q
THD
THF
Valid Data
Page14
SAMPLE Ver.01
SPEC Edi.003
Color Data Assignment
PH320240T-009-I-Q
Page15
SAMPLE Ver.01
SPEC Edi.003
2.4
JUMPER(Setting different use)
(J1-1J2-2,J3-2,J4-1,J5-1,J6-2)
PH320240T-009-I-Q
Page16
SAMPLE Ver.01
SPEC Edi.003
3. QUALITY ASSURANCE SYSTEM
3.1
Quality Assurance Flow Chart
Item
Customer
Sales
Info
Marketing
&
Design
R&D
Manufactu Product
Inventory
Purchase
ring
control
control
Q.A
Survey
Request
Project
Inquiry
evaluation
Project Validation
NG
OK
Quote
Contract
Design check
Sample test
Sample
Approval
NG
Verification
NG
OK
Sample approval
OK
Pilot
Pilot
Run
&
Mass
Product
NG
Verification
OK
Specification preparation
Mass production
OK
Ship
Out
PH320240T-009-I-Q
run & Reliability test
Inspection
NG
Shipment
Ship out
Page17
SAMPLE Ver.01
SPEC Edi.003
Item
Customer
Sales
Info
Claim
R&D
Q.A
Manufact Product
Inventory
Purchase
uring
control
control
Failure analysis
Sales
Service
Analysis report
Corrective action
Tracking
1. ISO 9001 Maintenance Activities
Q.A
3. Equipment calibration
Activity 5. Standardization Management
PH320240T-009-I-Q
Page18
2. Process improvement proposal
4. Education And Training Activities
SAMPLE Ver.01
SPEC Edi.003
3.2. Inspection Specification
PH320240T-009-I-Q
Page19
SAMPLE Ver.01
SPEC Edi.003
PH320240T-009-I-Q
Page20
SAMPLE Ver.01
SPEC Edi.003
PH320240T-009-I-Q
Page21
SAMPLE Ver.01
SPEC Edi.003
PH320240T-009-I-Q
Page22
SAMPLE Ver.01
SPEC Edi.003
PH320240T-009-I-Q
Page23
SAMPLE Ver.01
SPEC Edi.003
PH320240T-009-I-Q
Page24
SAMPLE Ver.01
SPEC Edi.003
PH320240T-009-I-Q
Page25
SAMPLE Ver.01
SPEC Edi.003
4. RELIABILITY TEST
4.1
Reliability Test Condition
(Ver.B01)
NO.
TEST ITEM
TEST CONDITION
1
High Temperature
Storage Test
2
Low Temperature
Storage Test
Keep in +80 ±2℃ 96 hrs
Surrounding temperature, then storage at normal condition 4hrs.
Keep in –30 ±2℃ 96 hrs
Surrounding temperature, then storage at normal condition 4hrs.
3
High Temperature /
High Humidity
Storage Test
Keep in +60 ℃ / 90% R.H duration for 96 hrs
Surrounding temperature, then storage at normal condition 4hrs.
(Excluding the polarizer)
-30℃
4
→
(30mins)
Temperature Cycling
Storage Test
+25℃
→
+80℃
→
(5mins)
(30mins)
10 Cycle
+25℃
(5mins)
Surrounding temperature, then storage at normal condition 4hrs.
5
ESD Test
Air Discharge:
Contact Discharge:
Apply 2 KV with 5 times
Apply 250 V with 5 times
Discharge for each polarity +/discharge for each polarity +/1. Temperature ambiance : 15℃∼35℃
2. Humidity relative : 30%∼60%
3. Energy Storage Capacitance(Cs+Cd) : 150pF±10%
4. Discharge Resistance(Rd) : 330Ω±10%
5. Discharge, mode of operation :
Single Discharge (time between successive discharges at least 1 sec)
(Tolerance if the output voltage indication : ±5%)
6
Vibration Test
(Packaged)
1. Sine wave 10∼55 Hz frequency (1 min/sweep)
2. The amplitude of vibration :1.5 mm
Each direction (X、Y、Z) duration for 2 Hrs
7
3.
Packing Weight (Kg)
0 ~ 45.4
Drop Height (cm)
122
45.4 ~ 90.8
76
90.8 ~ 454
61
Over 454
46
Drop Test
(Packaged)
Drop Direction :※1 corner / 3 edges / 6 sides each 1time
PH320240T-009-I-Q
Page26
SAMPLE Ver.01
SPEC Edi.003
5. PRECAUTION RELATING PRODUCT HANDLING
5.1 SAFETY
5.1.1
5.1.2
If the LCD panel breaks , be careful not to get the liquid crystal to touch your skin.
If the liquid crystal touches your skin or clothes , please wash it off immediately by
using soap and water.
5.2 HANDLING
5.2.1
5.2.2
5.2.8
Avoid any strong mechanical shock which can break the glass.
Avoid static electricity which can damage the CMOS LSI—When working with the
module , be sure to ground your body and any electrical equipment you may be using.
Do not remove the panel or frame from the module.
The polarizing plate of the display is very fragile. So , please handle it very
carefully ,do not touch , push or rub the exposed polarizing with anything harder
than an HB pencil lead (glass , tweezers , etc.)
Do not wipe the polarizing plate with a dry cloth , as it may easily scratch the
surface of plate.
Do not touch the display area with bare hands , this will stain the display area.
Do not use ketonics solvent & aromatic solvent. Use with a soft cloth soaked with
a cleaning naphtha solvent.
To control temperature and time of soldering is 320±10℃and 3-5 sec.
5.2.9
To avoid liquid (include organic solvent) stained on LCM .
5.2.3
5.2.4
5.2.5
5.2.6
5.2.7
5.3 STORAGE
5.3.1
Store the panel or module in a dark place where the temperature is 25℃ ±5℃
5.3.2
5.3.3
and the humidity is below 65% RH.
Do not place the module near organics solvents or corrosive gases.
Do not crush , shake , or jolt the module.
5.4 TERMS OF WARRANTY
5.4.1
5.4.2
Applicable warrant period
The period is within thirteen months since the date of shipping out under normal
using and storage conditions.
Unaccepted responsibility
This product has been manufactured to your company’s specification as a part for
use in your company’s general electronic products. It is guaranteed to perform
according to delivery specifications. For any other use apart from general
electronic equipment , we cannot take responsibility if the product is used in
nuclear power control equipment , aerospace equipment , fire and security
systems or any other applications in which there is a direct risk to human life
and where extremely high levels of reliability are required.
PH320240T-009-I-Q
Page27
SAMPLE Ver.01
SPEC Edi.003