APM-40 SERIES AC/DC Power Module 40W, Industrial & Medical Safety FEATURES ►Fully encapsulated Plastic Case ►3 Mounting Versions: - PCB Mounting with Solder Pins - Chassis Mounting with Screw Terminals - DIN-Rail Mounting ► Package Dimension 88.9x63.5x30.0 mm (PCB Version) ►Universal Input 85-264VAC, 47-440 Hz ►Protection Class ll ►Extended Operating Temp.Range -40°C to +60°C at full Load ►LED Output Indicator (Chassis Version Models) ►Industrial Safety to UL/cUL/IEC/EN 60950-1 and UL508 ►Medical Safety Approval to ANSI/AAMI ES60601-1 2XMOPP IEC/EN 60601-1 3rd Edition CB Report ►Over Load and Over Temperature Protection ►3 Year Product Warranty PRODUCT OVERVIEW The new MINMAX APM-40 series is a range of fully encapsulated AC/DC power modules. These high performance products feature an extended operating temperature range of -40°C to +80°C. Universal input voltage 85-264VAC and UL/IEC/EN safety approvals including medical safety and UL508 listing qualify these power supplies modules for applications in products with worldwide markets.EMI-filter meets EN55022, class B and FCC,part15, class B. The APM-40 series power modules provide an economical solution for many space critical applications in commercial, medical and industrial electronic equipment. Model Selection Guide Model Number PCB Mounting Output (For model with Chassis Voltage Output Current Input Current Max. capacitive Load Max. 115VAC, 60Hz 230VAC, 50Hz @Max. Load Mounting, add suffix C) VDC 5 12 15 24 ±12 ±15 APM-40S05 APM-40S12 APM-40S15 APM-40S24 APM-40D12 APM-40D15 mA 8000 3330 2660 1660 ±1660 ±1330 mA(typ.) 716 689 680 687 687 680 (typ.) @Max. Load, 115VAC μF 8000 3900 3900 680 1500# 1000# # For each output 429 414 408 413 413 408 Efficiency % 81 84 85 84 84 85 Input Specifications Parameter Model AC Voltage Input Range Input Frequency Range All Models DC Voltage Input Range No-Load Power Consumption Inrush Current (Cold Start at 25℃) E-mail:[email protected] 2014/08/07 REV:1 Typ. Max. Unit 85 --- 264 VAC 47 --- 440 Hz 120 --- 370 VDC --- --- 0.3 W 115VAC --- --- 30 A 230VAC --- --- 60 A Tel:886-6-2923150 Page 1 of 5 Min. APM-40 SERIES AC/DC Power Module 40W, Industrial & Medical Safety Output Specifications Parameter Conditions Min. Typ. Max. Unit ----- ±2.0 ±0.5 ----- --±1.0 --±2.0 No minimum Load Requirement 5VDC Output Models 1.5 --0-20 MHz Bandwidth Other Output Models 1.0 --Zener diode clamp 120 ----±0.02 ----85VAC, Hiccup Mode, auto-recovery 105 --(long term overload condition may cause damage) Hiccup mode, indefinite (automatic recovery) ----- % % % % 1.8 1.3 ----5 %VPP of Vo %VPP of Vo % of Vo %/℃ % --- % Inom. Max. Unit Output Voltage Accuracy Line Regulation Single Output Model Dual Output Models Load Regulation Min.Load Ripple & Noise Over Voltage Protection Temperature Coefficient Overshoot Current Limitation Short Circuit Protection General Specifications Parameter Conditions I/O Isolation Voltage (reinforced) Leakage Current I/O Isolation Resistance Switching Frequency Min. Typ. 4000 ----VACrms --80 --μA 500 VDC 1000 ----MΩ --130 --KHz 115VAC, 60Hz --25 --ms 230VAC, 50Hz --80 --ms MIL-HDBK-217F@25℃, Ground Benign 200,000 ----Hours According IEC/EN 60536 IEC/EN 60950-1 CB Report, cUL/UL 60950-1, CSA-C22.2 No.60950-1, UL508 listed certificate IEC/EN 60601-1 3rd Edition CB Report, ANSI/AAMI ES60601-1 2XMOPP, CAN/CSA-C22.2 No.60601-1 certificate Hold-up Time MTBF (calculated) Protection Class II Safety Approvals EMC Specifications Parameter Standards & Level Performance EN55011, EN55022, EN61000-6-4, EN61000-6-3, FCC part 15 EN60601-1-2, EN55024, EN61000-6-2, EN61000-6-1 ESD EN61000-4-2 air ± 8kV , Contact ± 4kV Radiated immunity EN61000-4-3 10V/m Fast transient EN61000-4-4 ±2kV Surge EN61000-4-5 ±1kV EN61000-4-6 10Vrms Conducted immunity EN61000-4-8 30A/M PFMF EN61000-4-11 30% 10ms Dips EN61000-4-11 >95% 5000ms Interruptions EMI EMS Class B A A A A A A A B Environmental Specifications Parameter Temperature Range (operational) Power Derating Storage Temperature Range Over Temperature Protection Humidity (non condensing) Cooling E-mail:[email protected] 2014/08/07 REV:1 Conditions Min. Max. Ambient Above +60℃ -40℃ +80℃ 1.5W / ℃ +95℃ -40℃ Shutdown at 90℃ (automatic recovery at approx. 67℃) --Free-Air convection Tel:886-6-2923150 Page 2 of 5 95% rel. H APM-40 SERIES AC/DC Power Module 40W, Industrial & Medical Safety Notes 1 This product is not designed for use in critical life support systems, equipment used in hazardous environment, nuclear control systems or other 2 Specifications typical at Ta=+25℃, resistive load, 115VAC, 60Hz input voltage, after warm-up time rated output current unless otherwise noted. 3 Ripple & Noise measured with a 0.1μF/50V MLCC and a 1μF/50V Aluminum electrolytic. such applications which necessitate specific safety and regulatory standards other the ones listed in this datasheet. 4 Safety approvals cover frequency 47-63 Hz. 5 We recommend to protect the converter by a slow blow fuse in the input supply line. 6 Other input and output voltage may be available, please contact factory. 7 To order the module with chassis mount package, please add a suffix C (e.g. APM-40S05C). 8 Part number for DIN-Rail mounting bracket: AC-DIN-02 9 That “natural convection” is about 20LFM but is not equal to still air (0 LFM). 10 Specifications are subject to change without notice. Package Specifications PCB Mounting Mechanical Dimensions Pin Connections 5 4 0.7 [0.03] 3 Pin Single Output Dual Output 1 AC (N) AC (N) 2 AC (L) AC (L) 3 +Vout +Vout 4 No Pin No Pin 5 -Vout Common 6 No Pin No Pin 7 NC -Vout [ 7 6 6.0 [0.24] 15.24 [0.60] 12.7 [0.50] 12.7 [0.50] 1.0 0.04] 15.24 [0.60] 30.0 [1.18] 15.9 [0.63] 88.9 [3.50] 81.3 [3.20] 31.6 [1.24] NC: No Connection 53.3 [2.10] Mounting M4.0 Thread Bottom View 2 1 5.0 [0.20] ►All 55.88 [2.20] 63.5 [2.50] Physical Characteristics Case Size : 88.9x63.5x30.0mm (3.50x2.50x1.18 inches) Case Material : Plastic resin (flammability to UL 94V-0 rated) Pin Material : Copper Alloy with Gold Plate Over Nickel Subplate Weight : 310g E-mail:[email protected] 2014/08/07 REV:1 Tel:886-6-2923150 Page 3 of 5 dimensions in mm (inches) ►Tolerance: ±0.5 ►Pin (±0.02) diameter 1.0 ±0.1 (0.04±0.004) APM-40 SERIES AC/DC Power Module 40W, Industrial & Medical Safety Package Specifications Chassis Mounting (order code suffix C) Mechanical Dimensions Connections Indication LED 50.0 [1.97] 7 6 5 4 3 2 Top view 63.8 [2.51] 4 x 3.5 1 DCON POWER "GOOD" INDICATOR Pin Single Output Dual Output 1 AC (N) AC (N) 2 AC (L) AC (L) 3 +Vout +Vout 4 NC NC 5 -Vout Common 6 NC NC 7 NC -Vout 100.0 [3.94] 112.0 [4.41] NC: No Connection 92.0 [3.62] 16.8 [0.66] 5.0 [0.20] 34.1 [1.34] 10.0 [0.39] Physical Characteristics Case Size : 112.0x63.8x34.1mm (4.41x2.51x1.34 inches) Case Material : Plastic resin (flammability to UL 94V-0 rated) Weight : 320g Package Specifications with DIN Rail Mounting Bracket Mechanical Dimensions 7 6 5 4 3 Indication LED Top view 2 1 63.8 [2.51] 3.5 50.0 [1.97] 4x DCON POWER "GOOD" INDICATOR 100.0 [3.94] 112.0 [4.41] 34.1 [1.34] 11.0 [0.43] 3.0 [0.12] 5.0 [0.20] 10.0 [0.39] 16.8 [0.66] 92.0 [3.62] Physical Characteristics Case Size : 112.0x63.8x34.1mm (4.41x2.51x1.34 inches) Case Material : Plastic resin (flammability to UL 94V-0 rated) Weight : 374g E-mail:[email protected] 2014/08/07 REV:1 Tel:886-6-2923150 Page 4 of 5 ►All dimensions in mm (inches) ►Tolerance: ±0.5 (±0.02) APM-40 SERIES AC/DC Power Module 40W, Industrial & Medical Safety DIN-Rail Mounting Bracket (Order code for Kit : AC-DIN-02) 18, Sin Sin Road, An-Ping Industrial District, Tainan 702, Taiwan Tel: 886-6-2923150 Fax: 886-6-2923149 E-mail: [email protected] Minmax Technology Co., Ltd. 2014/08/07 REV:1 Page 5 of 5