ADF-07 SERIES - MINMAX Technology

ADF-07 SERIES
AC/DC Power Module 7W
FEATURES
►Fully Encapsulated Plastic Case for PCB Mounting
►Universal Input 85~264VAC, 47~440Hz
►Protection Class II as per IEC/EN 60536
►I/O Isolation 3000VAC with Reinforced Insulation
►Operating Ambient Temp. Range -25℃ to +70℃
►Overload/Voltage/Temp. and Short Circuit Protection
►Designed-in EMI Emission meets EN55011/22 Class B & FCC Level B
►Designed-in EMC Immunity meets EN61000-4-2,3,4,5,6,8,11
►Eco Design, Compliant to Energy Star Specification and
ErP Directive 2009/125/EC
►UL/cUL/IEC/EN 60950-1 Safety Approval & CE Marking
PRODUCT OVERVIEW
The MINMAX ADF-07 series is a new range of fully encapsulated AC/DC power supply modules. They are designed for direct PCB mounting with solder
pins. The product features EMI-filter to EN55022, class B and EMS compliance to the EN 61000-4 standard. Universal input voltage 85-264VAC and
International safety approvals qualifies these power modules for applications in products with worldwide markets.
The ADF-07 series provide a cost effective solution for many space critical applications in commercial and industrial electronic equipment.
Model Selection Guide
Model
Output
Number
Voltage
VDC
3.3
5
12
15
24
ADF-07S03
ADF-07S05
ADF-07S12
ADF-07S15
ADF-07S24
Output Current
Input Current
Max. capacitive
Efficiency
Load
Max.
mA
1400
1400
583
466
291
115VAC, 60Hz
@Max. Load
mA(typ.)
96
139
130
130
130
(typ.)
@Max. Load
%
70
73
78
78
78
uF
2200
2200
1000
1000
680
Input Specifications
Parameter
Input Voltage Range
Input Frequency Range
Input Voltage Range
No-Load Power Consumption
Model
All Models
115VAC
230VAC
Inrush Current
External Fuse (Recommended)
Cold Start at 25℃
Min.
85
47
120
-------
All Models
Typ.
Max.
--264
--440
--370
--0.3
--10
--20
1.5A Slow – Blow Type
Unit
VAC
Hz
VDC
W
A
A
Output Specifications
Parameter
Output Voltage Setting Accuracy
Line Regulation
Load Regulation
Conditions
Vin=Min. to Max. @Full Load
Io=Min. to Max.
Ripple & Noise
0-20 MHz Bandwidth
Minimum Load
Over Voltage Protection
Temperature Coefficient
Overshoot
Zener diode clamp
Typ.
±1.0
±0.5
Max.
±2.0
±1.0
---------------
±0.5
1.5
0.8
10
120
±0.01
---
±1.0
1.8
1.0
----±0.02
5
Unit
%Vnom.
%
%
%VPP of Vo
%VPP of Vo
%Inom.
% of Vo
%/℃
% Vout
---
---
%Inom.
Foldback, auto-recovery
105
(long term overload condition may cause damage)
Hiccup mode, Automatic Recovery
Current Limitation
Short Circuit Protection
E-mail:[email protected]
2015/07/31 REV:16
3.3 & 5.0VDC Output Models
Other Output Models
Min.
-----
Tel:886-6-2923150
Page 1 of 3
ADF-07 SERIES
AC/DC POWER MODULE 7W
General Specifications
Parameter
I/O Isolation Voltage
I/O Isolation Resistance
Switching Frequency
Hold-up Time
MTBF (calculated)
Protection Class II
Safety Approvals
Conditions
Input to Output, 60 Seconds
500 VDC
Min.
3000
100
-----
Typ.
----100
20
MIL-HDBK-217F@25℃, Ground Benign
330,000
According IEC/EN 60536
cUL/UL 60950-1,IEC/EN 60950-1
Max.
---------
Unit
VACrms
MΩ
KHz
ms
Hours
Environmental Specifications
Parameter
Operating Ambient Temperature Range
(See Power Derating Curve)
Storage Temperature Range
Power Derating
Over Temperature Protection
Humidity (non condensing)
Cooling
Conditions
Min.
Max.
Unit
Natural Convection
-25
+70
℃
-40
+50℃ to +70℃
+85
0.263
at 90℃ (automatic recovery at 67℃)
--95
℃
W/℃
% rel. H
Natural Convection
EMC Specifications
Parameter
Standards & Level
EMI
Conduction and Radiation
EMS
EN55014-2 ,EN55024
ESD
Radiated immunity
Fast transient
Surge
Conducted immunity
PFMF
Dips
Interruptions
Performance
EN55014-1, EN55022, FCC part 15
Class B
EN61000-4-2 Air ± 8kV , Contact ± 4kV
EN61000-4-3 10V/m
EN61000-4-4 ±2kV
EN61000-4-5 ±1kV
EN61000-4-6 10Vrms
EN61000-4-8 30A/m
EN61000-4-11 30% 10ms
EN61000-4-11 >95% 5000ms
B
A
B
B
B
A
B
C
Notes
1
Specifications typical at Ta=+25℃, resistive load, 115VAC, 60Hz input voltage and after warm-up time rated output current unless otherwise noted.
2
These power modules require a minimum output loading to maintain specified regulation, operation under no-load conditions will not damage the power
3
We recommend to protect the converter by a slow blow fuse in the input supply line.
supplies however they may not meet all listed specifications.
4
Other input and output voltage may be available, please contact factory.
5
Specifications are subject to change without notice
E-mail:[email protected]
2015/07/31 REV:16
Tel:886-6-2923150
Page 2 of 3
ADF-07 SERIES
AC/DC POWER MODULE 7W
Package Specifications
Mechanical Dimensions
Pin Connections
6.0 [0.24]
10.16
[0.40]
0.7 [0.03]
1
Function
1
AC(N) – AC Neutral
2
AC(L) – AC Line
3
+Vout
4
-Vout
5.0 [0.20]
Bottom View
Pin
50.8 [2.00]
1.00
[ 0.04]
3
45.72 [1.80]
4
2
19.5 [0.77]
►All
dimensions in mm (inches)
►Tolerance: ±0.5
20.32 [0.80]
►Pin
25.4 [1.00]
(±0.02)
diameter  1.0 ±0.1 (0.04±0.004)
Physical Characteristics
Case Size
:
50.8x25.4x19.5mm (2.00x1.00x0.77 Inches)
Case Material
:
Plastic resin (flammability to UL 94V-0 rated)
Weight
:
44g
18, Sin Sin Road, An-Ping Industrial District, Tainan 702, Taiwan
Tel: 886-6-2923150 Fax: 886-6-2923149 E-mail: [email protected]
7
Minmax Technology Co., Ltd.
2015/07/31
REV:16
Page 3 of 3