MP2505 THRU MP2510

MP2505
THRU
MP2510
SINGLE-PHASE GLASS PASSIVATED
SILICON BRIDGE RECTIFIER
VOLTAGE RANGE 50 to 1000 Volts CURRENT 25 Amperes
FEATURES
*
*
*
*
Superior thermal desing
300 amperes surge rating
//
1/4 universal faston terminal
Hole thru for # 10 screw
MP-25
MECHANICAL DATA
* UL listed the recognized component directory, file #E94233
* Epoxy: Device has UL flammability classification 94V-O
Max. .311 (7.9)
.480 (12.2)
.425 (10.8)
1.142 (29)
1.102 (28)
.673 (17.1)
.634 (16.1)
MAXIMUM RATINGS AND ELECTRICAL CHARACTERISTICS
Hole for # 10 screw
Min f.200 (5.08)
.693 (17.6)
.732 (18.6)
1.142 (29)
1.102 (28)
.673 (17.1)
.634 (16.1)
Ratings at 25 o C ambient temperature unless otherwise specified.
Single phase, half wave, 60 Hz, resistive or inductive load.
.32 x .252 (0.81 x 6.35)
.583 (14.8)
For capacitive load, derate current by 20%.
.543 (13.8)
Dimensions in inches and (millimeters)
MAXIMUM RATINGS (At T A = 25oC unless otherwise noted)
SYMBOL
MP2505
MP251
Maximum Recurrent Peak Reverse Voltage
VRRM
50
Maximum RMS Bridge Input Voltage
VRMS
35
VDC
50
RATINGS
Maximum DC Blocking Voltage
o
Maximum Average Forward Rectified Output Current at Tc = 55 C
Peak Forward Surge Current 8.3 ms single half sine-wave
superimposed on rated load (JEDEC method)
RMS isolation voltage from case to lead
MP252
MP254
MP256
100
200
400
600
800
1000
Volts
70
140
280
420
560
700
Volts
MP2510 UNITS
100
200
400
600
800
1000
Volts
IO
25.0
Amps
I FSM
300
Amps
VISO
2500
Volts
Typical Thermal Resistance (from junction to case)
R θJC
1.9
Typical Thermal Resistance (from junction to ambient)
RθJA
19
T J, T STG
-55 to + 150
Operating and Storage Temperature Range
MP258
0
C/W
0
C
o
ELECTRICAL CHARACTERISTICS (At TA = 25 C unless otherwise noted)
SYMBOL
CHARACTERISTICS
VF
Maximum Forward Voltage Drop per element at 12.5A DC
o
Maximum Reverse Current at Rated
@T A = 25 C
DC Blocking Voltage per element
@T C = 100 o C
NOTE: 1. Suffix ”W” for wire type
2. ”Fully ROHS compliant”,”100% Sn plating(Pb-free).
IR
MP2505
MP251
MP252
MP254
MP256
MP258
MP2510 UNITS
1.1
Volts
5.0
uAmps
0.2
mAmps
2015-03
REV: B
RATING AND CHARACTERISTIC CURVES ( MP2505 THRU MP2510 )
FIG. 2 - TYPICAL FORWARD CURRENT
DERATING CURVE
500
400
300
200
100
0
100
1
2
4 6 8 10
20
40 60 80100
NUMBER OF CYCLES AT 60Hz
FIG. 3- TYPICAL INSTANTANEOUS FORWARD
CHARACTERISTICS
10
TJ = 25
Pulse Width = 300us
1% Duty Cycle
1.0
.1
.01
.6
AVERAGE FORWARD CURRENT, (A)
25
8.3ms Single Half Sine-Wave
(JEDEC Method)
1.2 1.3
.7
.8
.9
1.0
1.1
INSTANTANEOUS FORWARD VOLTAGE, (V)
INSTANTANEOUS REVERSE CURRENT, (uA)
INSTANTANEOUS FORWARD CURRENT, (A)
PEAK FORWARD SURGE CURRENT, (A)
FIG. 1 - MAXIMUM NON-REPETITIVE FORWARD
SURGE CURRENT
20
15
10
60 Hz RESISTIVE OR
INDUCTIVE LOAD
5
0
0
50
100
CASE TEMPERATURE, (
150
)
175
FIG. 4 - TYPICAL REVERSE CHARACTERISTICS
100
10
TJ = 25
1
0.1
0
20
40
60
80
100 120
140
PERCENT OF RATED PEAK REVERSE VOLTAGE, ( %)
RECTRON
Attachment information about MP25X
1.
Internal Circuit
2. Marking on the body
+
AC
Part No.
MP25X
Rectron Logo
VXXX
Plant - code
Year - code
Voltage-code
05-------50V
1-------100V
2-------200V
4-------400V
6-------600V
8-------800V
10-----1000V
UL Logo
Week - code
3. Items marked on the inner box and carton
3.1 On the box (for –B)
CUSTOMER
TYPE
LOT NO.
QUANTITY
Q.A.
DATE
3.2 On the carton
CUSTOMER
TYPE
QUANTITY
LOT NO.
REMARK
PACKAGING OF DIODE AND BRIDGE RECTIFIERS
BULK PACK
PACKAGE
PACKING CODE
MP-15/-25/-35
-B
EA PER BOX
50
INNER BOX SIZE
(mm)
206*208*45.5
CARTON SIZE
(mm)
450*220*255
EA PER CARTON
500
GROSS
WEIGHT(Kg)
9.6
DISCLAIMER NOTICE
Rectron Inc reserves the right to make changes without notice to any product
specification herein, to make corrections, modifications, enhancements or other
changes. Rectron Inc or anyone on its behalf assumes no responsibility or liability for any errors or inaccuracies. Data sheet specifications and its information
contained are intended to provide a product description only. "Typical" parameters which may be included on RECTRON data sheets and/ or specifications can and do vary in different applications and actual performance may vary over time. Rectron Inc does not assume any liability arising out of the application or
use of any product or circuit.
Rectron products are not designed, intended or authorized for use in medical,
life-saving implant or other applications intended for life-sustaining or other related applications where a failure or malfunction of component or circuitry may directly or indirectly cause injury or threaten a life without expressed written approval of Rectron Inc. Customers using or selling Rectron components for use in
such applications do so at their own risk and shall agree to fully indemnify Rectron Inc and its subsidiaries harmless against all claims, damages and expenditures.