VOLTAGE RANGE 50 to 1000 Volts CURRENT 6.0 Amperes
FEATURES
Low leakage
Low forward voltage
Silver-plated copper leads
Surge overload rating: 150 amperes peak
Mounting position: Any
RBU
MECHANICAL DATA
.880 (22.3)
.860 (21.8)
* Epoxy: Device has UL flammability classification 94V-O
.140 (3.56)
.130 (3.30)
.512 (13.0)
.740 (18.8)
.720 (18.3)
.160 (4.1)
.140 (3.5)
.080 (2.03)
.060 (1.52)
*
*
*
*
*
.710 (18.0)
.690 (17.5)
.085 (2.16)
.075 (1.90)
MAXIMUM RATINGS AND ELECTRICAL CHARACTERISTICS
Ratings at 25 o C ambient temperature unless otherwise specified.
Single phase, half wave, 60 Hz, resistive or inductive load.
.210 (5.33)
.190 (4.83)
For capacitive load, derate current by 20%.
.080 (2.03)
.065 (1.65)
.050 (1.27)
.040 (1.02)
.100 (2.54)
.085 (2.16)
.022 (0.56)
.018 (0.46)
Dimensions in inches and (millimeters)
MAXIMUM RATINGS (@ TA=25 OC unless otherwise noted)
RATINGS
SYMBOL
RBU601M RBU602M RBU603M RBU604M RBU605M RBU606M RBU607M
UNITS
Maximum Recurrent Peak Reverse Voltage
VRRM
50
100
200
400
600
800
1000
Maximum RMS Voltage
VRMS
35
70
140
280
420
560
700
Volts
VDC
50
100
200
400
600
800
1000
Volts
Maximum DC Blocking Voltage
Maximum Average Forward Rectified Current
o
at T C = *100 C (Note 4)
Peak Forward Surge Current 8.3 ms single half sine-wave
superimposed on rated load (JEDEC method)
Typical Thermal Resistance (Note 1)
Operating and Storage Temperature Range
Volts
IO
6.0
Amps
I FSM
150
Amps
R θ JC
3.5
R θ JA
26
T J, T STG
-55 to + 150
0
C/ W
0
C
ELECTRICAL CHARACTERISTICS (@TA=25 OC unless otherwise noted)
CHARACTERISTICS
Maximum Instantaneous Forward Voltage at 6.0A DC
Maximum DC Reverse Current
at Rated DC Blocking Voltage
@T A = 25o C
@T A = 125o C
SYMBOL
RBU601M RBU602M RBU603M RBU604M RBU605M RBU606M RBU607M
UNITS
VF
1.1
Volts
IR
NOTES : 1. Thermal Resistance : Heat-sink case mounted or if PCB mounted.
2. "Fully ROHS compliant", "100% Sn plating (Pb-free)".
3. Equivalent to Vishay's GBU6 Series.
4. "*" Heat Sink Temperature.
5.0
300
uAmps
2013-04
REV: A
8.0
6.0
4.0
2.0
0
0
50
100
150
INSTANTANEOUS FORWARD CURRENT, (A)
AVERAGE FORWARD OUTPUT CURRENT, (A)
RATING AND CHARACTERISTICS CURVES ( RBU601M THRU RBU607M )
40
10
4.0
1.0
0.4
0.1
0
O
FIG.1 TYPICAL FORWARD CURRENT
DERATING CURVE
1000
TA = 125 OC
100
10
1.0
0.1
TA = 25 OC
0
20
40
60
80
100
0.5
1.0
1.5
2.0
2.5
3.0
3.5
INSTANTANEOUS FORWARD VOLTAGE, (V)
PEAK FORWARD SURGE CURRENT, (A)
INSTANTANEOUS REVERSE CURRENT, (uA)
HEAT SINK TEMPERATURE, ( C)
TA = 25 OC
Pulse Width = 300mS
1% Duty Cycle
120
140
PERCENT RATED PEAK REVERSE VOLTAGE, (%)
FIG.3 TYPICAL REVERSE CHARACTERISTICS
240
FIG.2 TYPICAL INSTANTANEOUS
FORWARD CHARACTERISTICS
8.3mS Single Half Sine-Wave
JEDEC Method
200
160
120
80
40
0
1
2
5
10
20
50
100
NUMBER OF CYCLES AT 60Hz
FIG.4 MAXIMUM NON-REPETITIVE FORWARD
SURGE CURRENT
Marking Description
Rectron Logo
UL Logo
RBU60XM
VYWW
Year – code
(Y:Last digit of year
&A:2010,B:2011……)
Week – code:
(WW:01~52)
Part No.
Voltage-code
1-------50V
2-------100V
3-------200V
4-------400V
5-------600V
6-------800V
7-------1000V
PACKAGING OF DIODE AND BRIDGE RECTIFIERS
TUBE PACK
PACKAGE
PACKING CODE
EA PER BOX
INNER BOX SIZE
CARTON SIZE
(mm)
(mm)
RBU
-C
1,000
490*135*110
510*293*131
EA PER CARTON
WEIGHT(Kg)
2,000
13.62
DISCLAIMER NOTICE
Rectron Inc reserves the right to make changes without notice to any product
specification herein, to make corrections, modifications, enhancements or other
changes. Rectron Inc or anyone on its behalf assumes no responsibility or liability for any errors or inaccuracies. Data sheet specifications and its information
contained are intended to provide a product description only. "Typical" parameters which may be included on RECTRON data sheets and/ or specifications can and do vary in different applications and actual performance may vary over time. Rectron Inc does not assume any liability arising out of the application or
use of any product or circuit.
Rectron products are not designed, intended or authorized for use in medical,
life-saving implant or other applications intended for life-sustaining or other related applications where a failure or malfunction of component or circuitry may directly or indirectly cause injury or threaten a life without expressed written approval of Rectron Inc. Customers using or selling Rectron components for use in
such applications do so at their own risk and shall agree to fully indemnify Rectron Inc and its subsidiaries harmless against all claims, damages and expenditures.