SR8200S THRU SR820S

SR820S
THRU
SR8200S
SCHOTTKY BARRIER RECTIFIER
VOLTAGE RANGE 20 to 200 Volts CURRENT 8.0 Amperes
FEATURES
*
*
*
*
*
High reliability
Low switching loss
Low forward voltage drop
High current capability
High switching capability
D2-PAK
MECHANICAL DATA
.189 (4.80)
.173 (4.40)
.053 (1.35)
.049 (1.25)
Ratings at 25 o C ambient temperature unless otherwise specified.
Single phase, half wave, 60 Hz, resistive or inductive load.
For capacitive load, derate current by 20%.
.083 (2.10)
.098 (2.50)
.055 (1.40)
.047 (1.20)
.036 (0.91)
.028 (0.71)
.053 (1.35)
.069 (1.75)
.576 (14.64)
.323 (8.2)
.624 (15.84)
.346 (8.8)
.110 (2.80)
MAXIMUM RATINGS AND ELECTRICAL CHARACTERISTICS
.126 (3.20)
.049 (1.25 REF.)
* Epoxy: Device has UL flammability classification 94V-O
* Case: Molded plastic
* Lead: MIL-STD-202E method 208C guaranteed
* Mounting: position: Any
* Weight: 1.35 grams
.202 (5.13)
.020 (0.50)
.198 (5.03)
.412 (10.46)
.012 (0.30)
.388 (9.86)
Dimensions in inches and (millimeters)
MAXIMUM RATINGS (@ TA=25 OC unless otherwise noted)
SYMBOL
RATINGS
SR820S SR830S SR835S SR840S SR845S SR850S SR860S SR880S SR8100S
SR8150S SR8200S
UNITS
Maximum Recurrent Peak Reverse Voltage
VRRM
20
30
35
40
45
50
60
80
100
150
200
Maximum RMS Voltage
VRMS
14
21
25
28
32
35
42
56
70
105
140
Volts
VDC
20
30
35
40
45
50
60
80
100
150
200
Volts
Maximum DC Blocking Voltage
Maximum Average Forward Rectified Current
at Derating Case Temperature
Peak Forward Surge Current 8.3 ms single half sine-wave
superimposed on rated load (JEDEC method)
Typical Thermal Resistance (Note 1)
Volts
IO
8.0
Amps
I FSM
150
Amps
RqJA
60
RqJC
3
0
C/W
Typical Junction Capacitance (Note 2)
CJ
Operating Temperature Range
TJ
150
0
C
T STG
-55 to + 150
0
C
Storage Temperature Range
700
450
pF
ELECTRICAL CHARACTERISTICS (@TA=25 OC unless otherwise noted)
CHARACTERISTICS
Maximum Instantaneous Forward Voltage at 8.0A DC
Maximum Average Reverse Current
@T A = 25 o C
at Rated DC Blocking Voltage
@T A = 100 o C
SYMBOL
SR820S SR830S SR835S SR840S SR845S SR850S SR860S SR880S SR8100S
VF
IR
NOTES : 1. Thermal Resistance : Heat-sink case mounted or if PCB mounted.
2. Measured at 1 MHz and applied reverse voltage of 4.0 volts.
3. "Fully ROHS compliant", "100% Sn plating (Pb-free)".
4. Suffix "R" for Reverse Polarity.
5. Suffix "K" for D-PAK Pkg.
.65
.75
0.2
2
SR8150S SR8200S
.85
UNITS
Volts
mA
mA
2007-3
8
SR8
50S
6
~S R
0S
820
82
4
R8
0S
~S
45
0
S
2
Single Phase Half Wave
60Hz Inductive or
Resistive Load
0
50
100
150
INSTANTANEOUS FORWARD CURRENT, (mA)
10
SR
AVERAGE FORWARD CURRENT, (A)
RATING AND CHARACTERISTICS CURVES ( SR820S THRU SR8200S )
100
10
TA = 100 OC
1.0
TA = 25 OC
0.1
0.01
SR820S ~SR840S
SR850S~SR8200S
0
20
O
CJ, JUNCTION CAPACITANCE, (pF)
50
SR820S ~SR845S
10
SR850S ~SR860S
SR880S ~SR8200S
1.0
TJ = 25 C
Pulse width=300mS
1% Duty Cycle
O
0.1
0.1
0.2
0.3
0.4
0.5
0.6
0.7
40
60
0.8
100
120
140
0.9
1.0
FIG.2 TYPICAL REVERSE
CHARACTERISTICS
4000
2000
SR820S ~SR845S
1000
800
600
400
SR850S ~SR8200S
200
100
0.1
0.4
INSTANTANEOUS FORWARD VOLTAGE, (V)
1.0
4
10
40
REVERSE VOLTAGE, (V)
FIG.3 TYPICAL INSTANTANEOUS FORWARD
CHARACTERISTICS
155
FIG.4 TYPICAL JUNCTION CAPACITANCE
8.3mS Single Half Sine-Wave
JEDEC Method
150
145
140
135
130
125
1
80
PERCENT OF RATED PEAK REVERSE VOLTAGE, (%)
FIG.1 TYPICAL FORWARD CURRENT
DERATING CURVE
PEAK FORWARD SURGE CURRENT, (A)
INSTANTANEOUS REVERSE CURRENT, (A)
CASE TEMPERATURE, ( C)
2
5
10
20
50
100
NUMBER OF CYCLES AT 60Hz
FIG.5 MAXIMUM NON-REPETITIVE FORWARD
SURGE CURRENT
80100
DISCLAIMER NOTICE
Rectron Inc reserves the right to make changes without notice to any product
specification herein, to make corrections, modifications, enhancements or other
changes. Rectron Inc or anyone on its behalf assumes no responsibility or liability for any errors or inaccuracies. Data sheet specifications and its information
contained are intended to provide a product description only. "Typical" parameters which may be included on RECTRON data sheets and/ or specifications can and do vary in different applications and actual performance may vary over time. Rectron Inc does not assume any liability arising out of the application or
use of any product or circuit.
Rectron products are not designed, intended or authorized for use in medical,
life-saving implant or other applications intended for life-sustaining or other related applications where a failure or malfunction of component or circuitry may directly or indirectly cause injury or threaten a life without expressed written approval of Rectron Inc. Customers using or selling Rectron components for use in
such applications do so at their own risk and shall agree to fully indemnify Rectron Inc and its subsidiaries harmless against all claims, damages and expenditures.