Optically Coupled Isolator

Optically Coupled Isolator
OPI120, OPI123
Features:
•
•
•
•
•
15 kV electrical isolation
Choice of phototransistor or photodarington output
Hermetically sealed LED and photosensor
Base contact for conventional transistor biasing (OP120 only)
UL recognized File No. E58730*
Product Photo Here
Description:
Each Optoisolator in this data sheet contains an infrared Light Emitting Diode (LED) and a NPN silicon
Photosensor. The OPI120 has an 890 nm Light Emitting Diode (LED) and NPN phototransistor sensor, whereas
the OP123 has a 890 nm LED and a photodarlington sensor. The devices are sealed in a precast opaque housing
with a optically transmissive path between the LED and the photosensor.
The Optoisolators in this data sheet are UL approved under E 58730.
This series is designed for transmission of information between one power supply voltage another where the
potentials during surge conditions are not greater than the guaranteed isolation voltage.
Custom electrical, wire and cabling and connectors are available. Contact your local representative or OPTEK for
more information.
TX and TXV processing is available. For more information, contact your local representative or OPTEK.
Applications:
•
•
•
•
•
High voltage isolation between input
and output
Electrical isolation in dirty environments
Ordering Information
Part
Number
LED Peak
Wavelength
Sensor
Industrial equipment
OPI120
Medical equipment
OPI123
890 nm
or
935 nm
Darlington
Isolation
Voltage
(,000)
Transistor
CTR
Min
IF (mA)
Typ / Max
VCE
(Volts)
Max
Lead
Length /
Spacing
25
0.40" /
0.75"
20
15
50
10 / 50
20
Office equipment
RoHS
OPTEK reserves the right to make changes at any time in order to improve design and to supply the best product possible.
OPTEK Technology Inc. — 1645 Wallace Drive, Carrollton, Texas 75006
Phone: (972) 323-2200 or (800) 341-4747
FAX: (972) 323-2396 [email protected] www.optekinc.com
Issue A
05/07
Page 1 of 3
Optically Coupled Isolator
OPI120, OPI123
Absolute Maximum Ratings (TA = 25o C unless otherwise noted)
Storage Temperature
-55° C to +125° C
Operating Temperature
-55° C to +100° C
(1)(2)
Input-to-Output Isolation Voltage
± 15 kVDC
(3)
Lead Soldering Temperature (1/16” (1.6 mm) from case for 5 seconds with soldering iron)
260° C
Input Diode
Forward DC Current(4)
150 mA
Reverse DC Voltage
Power Dissipation
3V
(5)
200 mW
Output Photosensor
Collector-Emitter Voltage
OPI120
OPI123
25 V
20 V
Emitter-Collector Voltage
5V
Collector-Base Voltage
OPI120
25 V
Power Dissipation(6)
250 mW
Notes:
(1) Measured with input and output leads shorted in air with a maximum relative humidity of 50%. If suitably encapsulated or oilimmersed, the isolation voltage is increased to 25 kV minimum.
(2) UL recognition is for 3750 VAC to 100° C.
(3) RMA flux is recommended. The duration can be extended to 10 seconds maximum when flow soldering.
(4) Derate linearly 2.0 mA/°C above 25°C.
(5) Derate linearly 2.67 mA/°C above 25°C.
(6) Derate linearly 3.33 mA/°C above 25°C.
OPI120
1
5
4 - Base
2
3
OPI123
1
5
2
3
DIMENSIONS ARE IN:
Pin #
LED
1
2
Anode
Cathode
Pin # Transistor Pin #
3
4
5
Emitter
Base
Collector
3
4
5
[MILLIMETERS]
INCHES
Darlington
Emitter
Open
Collector
OPTEK reserves the right to make changes at any time in order to improve design and to supply the best product possible.
Issue A
05/07
Page 2 of 3
OPTEK Technology Inc. — 1645 Wallace Drive, Carrollton, Texas 75006
Phone: (972) 323-2200 or (800) 341-4747
FAX: (972) 323-2396 [email protected] www.optekinc.com
Optically Coupled Isolator
OPI120, OPI123
Electrical Characteristics (-40o C to +85° C unless otherwise noted)
SYMBOL
PARAMETER
MIN
TYP
MAX
UNITS
TEST CONDITIONS
Input Diode
VF
Forward Voltage
OPI120
OPI123
-
-
1.5
1.5
V
IF = 30 mA
IF = 10 mA
IR
Reverse Current
-
-
100
µA
VR = 3 V
Output Photosensor (See OP236 for additional information - for reference only)
V(BR)CEO
Collector-Emitter Breakdown Voltage
OPI120
OPI123
25
20
-
-
V
IC = 1 mA
IC = 1 mA
V(BR)ECO
Emitter-Collector Breakdown Voltage
5
-
-
V
IE = 100 µA
V(BR)CBO
Collector-Base Breakdown Voltage
OPI120
25
-
-
-
-
100
ICEO
Collector-Emitter Dark Current
V
nA
IC = 1 mA
VCE = 10 V
Coupled (See OP804 and OP805 for additional information - for reference only)
IC/IF
VCE(SAT)
DC Current Transfer Ratio
OPI120
OPI123
Collector Saturation Voltage
OPI120
OPI123
VISO
Isolation Voltage(1)
tr, tf
Output Rise Time, Output Fall Time
OPI120
OPI123
20
50
70
-
-
%
IF = 10 mA, VCE = 5 V
IF = 10 mA, VCE = 2 V
-
-
0.5
1.2
V
IF = 30 mA, IC = 1 mA
IF = 5 mA, IC = 1 mA
15
-
-
kV
See note 1
-
2
40
-
µs
See Test Circuit
Notes:
(1) Measured with input and output leads shorted in air with a maximum relative humidity of 50%.
If suitably encapsulated or oil-immersed, the isolation voltage is increased to 25 kV minimum.
Vcc
Vcc
Vcc
IF = 10 mA
Vcc
IF = 10 mA
Vout
R = 200 Ohms
Vout
R = 50 Ohms
R = 200 Ohms
R = 50 Ohms
Test Circuit
OPTEK reserves the right to make changes at any time in order to improve design and to supply the best product possible.
OPTEK Technology Inc. — 1645 Wallace Drive, Carrollton, Texas 75006
Phone: (972) 323-2200 or (800) 341-4747
FAX: (972) 323-2396 [email protected] www.optekinc.com
Issue A
05/07
Page 3 of 3