GPC55 Instructions - SL Power Electronics

SL POWER ELECTRONICS CORP.
6050 King Drive, Bdlg A
Ventura, CA 93003 + 805-486-4565
Internet: www.slpower.com
GPC55 SERIES
INSTALLATION INSTRUCTIONS
MODEL NUMBERS: GPC55A, GPC55B, GPC55C, GPC55D, GPC55E, GPC55F and GPC55-X, where X represents the output
voltage which may be any number from 5,12,15,24,28 or 48. Models amy or may not followed by suffix –XXX and/or G, where
XXX may be any number from 001 thru 999. The –XXX suffix are used for value added configurations that have no impact on
safety and/or suffix G to indicate compliance to RoHS.
RATINGS:
Input: 100-240 V ac, 1.7 A, 50/60 Hz
Outputs: 55 W Maximum Continuous Power - Total of all Outputs.
Model
Watts
Output #1
Isc
Output #2
Isc
Output #3
Isc
Output #4
Isc
GPC55A
GPC55B
GPC55C
GPC55D
GPC55E
GPC55F
GPC55- 5
GPC55- 12
GPC55- 15
GPC55- 24
GPC55- 28
GPC55- 48
55
55
55
55
55
55
55
55
55
55
56
72
+ 5 V dc 6 A
+ 5 V dc 6 A
+ 5 V dc 6 A
+ 5 V dc 6 A
+ 5 V dc 6 A
+ 5 V dc 6 A
5 V dc 11 A
12 V dc 4.7
15 V dc 3.7
24 V dc 2.3
28 V dc 2.0
48 V dc 1.5
A
A
A
A
A
4
4
4
4
4
4
5
2
2
1
1
1
A
A
A
A
A
A
A
A
A
A
A
A
+ 12
+ 12
+ 15
+ 24
+ 24
+ 12
V
V
V
V
V
V
dc
dc
dc
dc
dc
dc
3 A
3 A
3 A
1.5 A
1.5 A
3 A
4
4
4
2
2
2
A
A
A
A
A
A
+ 12 V dc
- 5 V dc 1
- 5 V dc 1
+ 12 V dc
+ 15 V dc
+ 15 V dc
1 A
A
A
1 A
1 A
1 A
3
3
3
3
3
3
A
A
A
A
A
A
- 12
- 12
- 15
- 12
- 15
- 15
V
V
V
V
V
V
dc
dc
dc
dc
dc
dc
1
1
1
1
1
1
A
A
A
A
A
A
3
3
3
3
3
3
A
A
A
A
A
A
Notes:
1. Isc = Maximum output short circuit current.
2. Maximum ambient temperature for continuous output power of 55 W is 50 °C.
3. Maximum Relative Humidity 96 %, no condensation.
4.
Storage: -40 to +85 °C. Units should be allowed to warm-up under non-condensing
conditions before application of power.
SAFETY DECLARATION: SL Power Electronics Corp.declares under our sole responsibility that all models
listed above are in conformity with the applicable requirements of EN 60950-1 following the provisions of the Low
Voltage Directive 2006/95/EC. All models are Certified to be in compliance with the applicable requirements of
UL 1950, CSA 22.2 No. 234-M90 (Level 3), and EN 60950-1 for Pollution Degree 2 environment and Class I TNS power systems. The output(s) of these supplies meet the requirements for SELV and are not an energy hazard.
GROUNDING: The Functional Earth (Ground) terminal J1-1 and all of the pads around the mounting holes must be bonded to
Protective Earth in the host equipment. Metallic spacers should be used to mount supply to metal surfaces. When mounting to
non-metallic surfaces, connect all mounting pads together and bond to earth. Using J1-1 on the supply for the end product
protective earthing terminal is not recommended. A separate dedicated protective earthing point should be used.
SPACINGS: Creepage and clearance distances from primary circuits to ground and secondary circuits, as defined in the
applicable safety standards, must be maintained after installation to preserve the intended safety.
TEMPERATURES: The maximum operating temperatures of certain safety components, as defined in the applicable safety
standards, must not be exceeded after installation to preserve the intended safety. The output power, ambient air temperature and
the availability, amount, direction and/or restriction of airflow influence the temperatures of these components.
WARNING! RISK OF FIRE! A blown internal fuse is an indication of catastrophic failure of circuit component(s). Repair must
be performed by SL Power Electronics Corp authorized personnel. Refer to fuse marking on the supply for type and rating.
WARNING! SHOCK HAZARD! Dangerous voltages are present on some components, printed wiring traces and heatsinks.
CONNECTIONS
EXPLANATION OF SYMBOLS
J1 AC Input
J2 Multi-Output Models
J2 Single Output Models
Alternating Current
1) Ground
1) Output 2 (+) 6) Common
1) Output 1 (+) 6) Common
3) Neutral
2) Output 2 (+) 7) Common
2) Output 1 (+) 7) Common
Direct Current
5) Line
3) Output 1 (+) 8) Output 4 (-)
3) Output 1 (+) 8) N/C
Attention, Consult
Accompanying Documents
4) Output 1 (+) 9) Output 3 (+/-) 4) Output 1 (+) 9) N/C
Attention, Dangerous Voltages
5) Common
5) Common
MATING CONNECTORS
J1 Amp P/N 640250-5, Contact
J2 Amp P/N 640250-9, Contact Amp P/N 770476-1
Functional Earth (Ground)
SL Power Electronics Corp. will not be liable for the safety, reliability or performance of these power supplies if a) any changes, modifications or repairs are carried out by other than authorized
agents of SL Power Electronics Corp., or b) the installation of the supply is not in accordance with these installation instructions and the applicable UL, CSA, EN/IEC safety standards.
41-32495-0001 Rev. M