Installation Instructions

SL POWER ELECTRONICS CORP.
6050 King Drive, Bldg. A
Ventura, CA 93003 + 805-486-4565
Internet: www.slpower.com
INTERNATIONAL + LINEAR SERIES
INSTALLATION INSTRUCTIONS
RATINGS:
Input: 100/120/215/230-240 V ac, 50/60 Hz
Derate output current 10 % for operation at 50 Hz.
Refer to chassis marking for input current ratings.
Output: See table on Page 2.
Notes:
1.
2.
3.
Maximum ambient temperature for continuous output specified in the table is 50 °C.
Maximum Relative Humidity 96 %, no condensation.
Storage: -40 to +85 °C. Units should be allowed to warm-up under non-condensing conditions before application of
power.
SAFETY DECLARATION:
SL Power Electronics Corp. declares under our sole
responsibility that all models listed above are in conformity with the applicable requirements of
EN 60950-1 following the provisions of the Low Voltage Directive 73/23/EEC. All models are
Certified to be in compliance with the applicable requirements of IEC/EN/UL/CSA 60950-1 for
Pollution Degree 2 environment and Class I TN-S power systems. The output of some models do not meet the
requirements for SELV. To identify these models, refer to the notes for the table.
GROUNDING:
application.
Protection Class I requires that the chassis be bonded to Protective Earth in the end
SPACINGS: Creepage and clearance distances from primary circuits to ground and secondary circuits, as
defined in the applicable safety standards, must be maintained after installation to preserve the intended safety.
TEMPERATURES: The maximum operating temperatures of certain safety components, as defined in the
applicable safety standards, must not be exceeded after installation to preserve the intended safety. The output
power, ambient air temperature and the availability, amount, direction and/or restriction of airflow influence the
temperatures of these components.
WARNING! RISK OF FIRE! All models require external fusing to maintain the intended safety. Refer to
marking on chassis for maximum fuse ratings.
AC INPUT HOOKUP INSTRUCTIONS
1
1
2
100 VAC
3
5
4
1
2
120 VAC
3
5
4
2
215 VAC
3
5
4
1
230-240
VAC
2
3
5
4
SL Power Electronics Corp. will not be liable for the safety, reliability or performance of these power supplies if a) any changes, modifications or repairs are carried out by other than authorized
agents of SL Power Electronics Corp., or b) the installation of the supply is not in accordance with these installation instructions and the applicable UL, CSA, and IEC/EN safety standards.
41-32350-0001 Rev. K 09/06/06
Page 1
INTERNATIONAL + LINEAR SERIES
MODEL
HA15-0.9-A+
HA2-1.5-A+
HA24-0.5-A+
HA5-1.5/OVP-A+
HB12-1.7-A+
HB15-1.5-A+
HB2-3-A+
HB24-1.2-A+
HB28-1-A+
HB48-0.5-A+
(1)
HB5-3/OVP-A+
HC12-3.4-A+
HC15-3-A+
HC2-6-A+
HC24-2.4-A+
HC28-2-A+
MODEL
Maximum Output Ratings CSA
Level
50 °C Ambient
MODEL
SINGLE OUTPUT MODELS
12 V or 15V 0.9 A
2 V 1.5 A
24 V or 28 V 0.5 A
5 V 1.5 A
12 V 1.7 A
15 V 1.5 A
2V3A
24 V 1.2 A
28 V 1 A
48 V 0.5 A
5V3A
12 V 3.4 A
15 V 3 A
2V6A
24 V 2.4 A
28 V 2 A
L3M1
L3M1
L3M1
L3M1
L3M1
L3M1
L3M1
L3M1
L3M1
L1
L3M1
L3M1
L3M1
L3M1
L3M1
L3M1
HC48-1-A+
(1)
HC5-6/OVP-A+
HD12-6.8-A+
HD15-6-A+
HD2-12-A+
HD24-4.8-A+
HD28-4-A+
HD48-3-A+
(1)
HD5-12/OVP-A+
HN12-5.1-A+
HN15-4.5-A+
HN2-9-A+
HN24-3.6-A+
HN28-3-A+
HN5-9/OVP-A+
Maximum Output Ratings
50 °C Ambient
CSA
Level
48 V 1 A
5V6A
12 V 6.8 A
15 V 6 A
2 V 12 A
24 V 4.8 A
28 V 4 A
48 V 2.5 A (3 A with 14 cfm airflow)
5 V 12 A
12 V 5.1 A
15 V 4.5 A
2V9A
24 V 3.6 A
28 V 3 A
5V9A
L1
L3M1
L3M1
L3M1
L3M1
DUAL OUTPUT MODELS
Maximum Output Ratings 50 °C Ambient
L3M1
L3M1
L1
L3M1
L3M1
L3M1
L3M1
L3M1
L3M1
L3M1
CSA
Level
CP323-A+
HAA15-0.8-A+
HAA24-0.6-A+
HAA5-1.5/OVP-A+
HAA512-A+
HAA524-A+
HAD12-0.4-A+
HAD15-0.4-A+
HBB15-1.5-A+
HBB5-3/OVP-A+
HBB512-A+
HBB524-A+
HCC15-3-A+
HCC5-6/OVP-A+
HCC512-A+
HCC524-A+
12 V 4 A; 5 V 2 A
+12 V 1 A or +15 V 0.8 A; -12 V 1 A or -15V 0.8 A or –5 V 0.4 A
±24 V 0.6 A
±5 V 1.5 A
5 V 2 A; 9-15 V 0.5 A
5 V 2 A; 18-24 V 0.3 A
±12 V 0.4 A
±15 V 0.4 A
+12 V 1.7 A or +15 V 1.5 A; -12 V 1.7 A or –15 V 1.5 A or –5 V 0.7 A
±5 V 3 A
5 V 3 A; 9-15 V 1.25 A
5 V 3 A; 18-24 V 0.8 A
+12 V 3.4 A or +15 V 3 A; -12 V 3.4 A or –15 V 3 A or –5 V 1.4 A
±5 V 4 A (6 A with 14 cfm airflow)
5 V 4 A (6 A with 14 cfm airflow); 9-15 V 2.5 A
5 V 4 A (6 A with 14 cfm airflow); 18-24 V 2 A
CP131-A+
CP206-A+
HBAA40W-A+
HCAA60W-A+
HCBB105W-A+
5 V 9 A; +12 V 1.7 A or +15 V 1.5 A; -12 V 1.7 A or –15 V 1.5 A or –5 V 0.7 A
24 V 3 A; +5 V 2.5 A, -5 V 1.0 A
5 V 3 A; +12 V 1 A or +15 V 0.8 A; -12 V 1 A or –15 V 0.8 A or –5 V 0.4 A
5 V 6 A; +12 V 1 A or +15 V 0.8 A; -12 V 1 A or –15 V 0.8 A or –5 V 0.4 A
5 V 3 A; +12 V 2.5 A or +15 V 2 A; -12 V 2.5 A or –15 V 2 A or –5 V 1 A
(+12 V 3.4 A or +15 V 3 A; -12 V 3.4 A or –15 V 3 A or –5 V 1.5 A with 14 cfm airflow)
5 V 6 A; +12 V 1.7 A or +15 V 1.5 A; -12 V 1.7 A or –15 V 1.5 A or –5 V 0.7 A
5 V 2 A; +9-15 V 0.4 A; -9 to –15 V 0.4 A or –5 V 0.4 A
L3M1
L3M1
L1
L3M1
L3M1
L3M1
L3M1
L3M1
L3M1
L3M1
L3M1
L3M1
L3M1
L3M1
L3M1
L3M1
TRIPLE OUTPUT MODELS
HCBB75W-A+
HTAA-16W-A+
Notes:
1.
Models may be followed by suffix G to indicate compliance to RoHS.
2.
48 V models are not approved for SELV. The output voltage may exceed 60 V under certain conditions.
41-32350-0001 Rev. K 09/06/06
Page 2
L3M1
L3M1
L3M1
L3M1
L3M1
L3M1
L3M1