SL POWER ELECTRONICS CORP. 6050 King Drive, Bldg. A Ventura, CA 93003 + 805-486-4565 Internet: www.slpower.com INTERNATIONAL + LINEAR SERIES INSTALLATION INSTRUCTIONS RATINGS: Input: 100/120/215/230-240 V ac, 50/60 Hz Derate output current 10 % for operation at 50 Hz. Refer to chassis marking for input current ratings. Output: See table on Page 2. Notes: 1. 2. 3. Maximum ambient temperature for continuous output specified in the table is 50 °C. Maximum Relative Humidity 96 %, no condensation. Storage: -40 to +85 °C. Units should be allowed to warm-up under non-condensing conditions before application of power. SAFETY DECLARATION: SL Power Electronics Corp. declares under our sole responsibility that all models listed above are in conformity with the applicable requirements of EN 60950-1 following the provisions of the Low Voltage Directive 73/23/EEC. All models are Certified to be in compliance with the applicable requirements of IEC/EN/UL/CSA 60950-1 for Pollution Degree 2 environment and Class I TN-S power systems. The output of some models do not meet the requirements for SELV. To identify these models, refer to the notes for the table. GROUNDING: application. Protection Class I requires that the chassis be bonded to Protective Earth in the end SPACINGS: Creepage and clearance distances from primary circuits to ground and secondary circuits, as defined in the applicable safety standards, must be maintained after installation to preserve the intended safety. TEMPERATURES: The maximum operating temperatures of certain safety components, as defined in the applicable safety standards, must not be exceeded after installation to preserve the intended safety. The output power, ambient air temperature and the availability, amount, direction and/or restriction of airflow influence the temperatures of these components. WARNING! RISK OF FIRE! All models require external fusing to maintain the intended safety. Refer to marking on chassis for maximum fuse ratings. AC INPUT HOOKUP INSTRUCTIONS 1 1 2 100 VAC 3 5 4 1 2 120 VAC 3 5 4 2 215 VAC 3 5 4 1 230-240 VAC 2 3 5 4 SL Power Electronics Corp. will not be liable for the safety, reliability or performance of these power supplies if a) any changes, modifications or repairs are carried out by other than authorized agents of SL Power Electronics Corp., or b) the installation of the supply is not in accordance with these installation instructions and the applicable UL, CSA, and IEC/EN safety standards. 41-32350-0001 Rev. K 09/06/06 Page 1 INTERNATIONAL + LINEAR SERIES MODEL HA15-0.9-A+ HA2-1.5-A+ HA24-0.5-A+ HA5-1.5/OVP-A+ HB12-1.7-A+ HB15-1.5-A+ HB2-3-A+ HB24-1.2-A+ HB28-1-A+ HB48-0.5-A+ (1) HB5-3/OVP-A+ HC12-3.4-A+ HC15-3-A+ HC2-6-A+ HC24-2.4-A+ HC28-2-A+ MODEL Maximum Output Ratings CSA Level 50 °C Ambient MODEL SINGLE OUTPUT MODELS 12 V or 15V 0.9 A 2 V 1.5 A 24 V or 28 V 0.5 A 5 V 1.5 A 12 V 1.7 A 15 V 1.5 A 2V3A 24 V 1.2 A 28 V 1 A 48 V 0.5 A 5V3A 12 V 3.4 A 15 V 3 A 2V6A 24 V 2.4 A 28 V 2 A L3M1 L3M1 L3M1 L3M1 L3M1 L3M1 L3M1 L3M1 L3M1 L1 L3M1 L3M1 L3M1 L3M1 L3M1 L3M1 HC48-1-A+ (1) HC5-6/OVP-A+ HD12-6.8-A+ HD15-6-A+ HD2-12-A+ HD24-4.8-A+ HD28-4-A+ HD48-3-A+ (1) HD5-12/OVP-A+ HN12-5.1-A+ HN15-4.5-A+ HN2-9-A+ HN24-3.6-A+ HN28-3-A+ HN5-9/OVP-A+ Maximum Output Ratings 50 °C Ambient CSA Level 48 V 1 A 5V6A 12 V 6.8 A 15 V 6 A 2 V 12 A 24 V 4.8 A 28 V 4 A 48 V 2.5 A (3 A with 14 cfm airflow) 5 V 12 A 12 V 5.1 A 15 V 4.5 A 2V9A 24 V 3.6 A 28 V 3 A 5V9A L1 L3M1 L3M1 L3M1 L3M1 DUAL OUTPUT MODELS Maximum Output Ratings 50 °C Ambient L3M1 L3M1 L1 L3M1 L3M1 L3M1 L3M1 L3M1 L3M1 L3M1 CSA Level CP323-A+ HAA15-0.8-A+ HAA24-0.6-A+ HAA5-1.5/OVP-A+ HAA512-A+ HAA524-A+ HAD12-0.4-A+ HAD15-0.4-A+ HBB15-1.5-A+ HBB5-3/OVP-A+ HBB512-A+ HBB524-A+ HCC15-3-A+ HCC5-6/OVP-A+ HCC512-A+ HCC524-A+ 12 V 4 A; 5 V 2 A +12 V 1 A or +15 V 0.8 A; -12 V 1 A or -15V 0.8 A or –5 V 0.4 A ±24 V 0.6 A ±5 V 1.5 A 5 V 2 A; 9-15 V 0.5 A 5 V 2 A; 18-24 V 0.3 A ±12 V 0.4 A ±15 V 0.4 A +12 V 1.7 A or +15 V 1.5 A; -12 V 1.7 A or –15 V 1.5 A or –5 V 0.7 A ±5 V 3 A 5 V 3 A; 9-15 V 1.25 A 5 V 3 A; 18-24 V 0.8 A +12 V 3.4 A or +15 V 3 A; -12 V 3.4 A or –15 V 3 A or –5 V 1.4 A ±5 V 4 A (6 A with 14 cfm airflow) 5 V 4 A (6 A with 14 cfm airflow); 9-15 V 2.5 A 5 V 4 A (6 A with 14 cfm airflow); 18-24 V 2 A CP131-A+ CP206-A+ HBAA40W-A+ HCAA60W-A+ HCBB105W-A+ 5 V 9 A; +12 V 1.7 A or +15 V 1.5 A; -12 V 1.7 A or –15 V 1.5 A or –5 V 0.7 A 24 V 3 A; +5 V 2.5 A, -5 V 1.0 A 5 V 3 A; +12 V 1 A or +15 V 0.8 A; -12 V 1 A or –15 V 0.8 A or –5 V 0.4 A 5 V 6 A; +12 V 1 A or +15 V 0.8 A; -12 V 1 A or –15 V 0.8 A or –5 V 0.4 A 5 V 3 A; +12 V 2.5 A or +15 V 2 A; -12 V 2.5 A or –15 V 2 A or –5 V 1 A (+12 V 3.4 A or +15 V 3 A; -12 V 3.4 A or –15 V 3 A or –5 V 1.5 A with 14 cfm airflow) 5 V 6 A; +12 V 1.7 A or +15 V 1.5 A; -12 V 1.7 A or –15 V 1.5 A or –5 V 0.7 A 5 V 2 A; +9-15 V 0.4 A; -9 to –15 V 0.4 A or –5 V 0.4 A L3M1 L3M1 L1 L3M1 L3M1 L3M1 L3M1 L3M1 L3M1 L3M1 L3M1 L3M1 L3M1 L3M1 L3M1 L3M1 TRIPLE OUTPUT MODELS HCBB75W-A+ HTAA-16W-A+ Notes: 1. Models may be followed by suffix G to indicate compliance to RoHS. 2. 48 V models are not approved for SELV. The output voltage may exceed 60 V under certain conditions. 41-32350-0001 Rev. K 09/06/06 Page 2 L3M1 L3M1 L3M1 L3M1 L3M1 L3M1 L3M1