LB130S 130W Single Output LED Supply Features 3” x 5” x 1.3” Package 130 Watts Class B Conducted EMI 70°C Ambient Operation with No derating (Conduction Cooled) Universal Input 90-264Vac Meets IEC61000-3-2 Class C for 0% to 100% LED Dimming Applications(5 Watts to 130 Watts) EN60950 2nd Edition 3 Year Warranty RoHS Compliant Description The LB130 model is the highest density conduction cooled power supply in a compact 3X5 package. Providing 130 Watts of power at 70°C ambient, the LB130 is designed to meet global lighting requirements and has a built-in EMI filter to meet EN55015 class B. With over 50,000 hours of life expectancy at 70°C, the LB130 supports the requirements of the Design Lighting Consortium (DLC) standard. Model Chart Maximum Output Current Model Number Volts LB130S56K 56V 2.32 Minimum Load Ripple & Noise* Total Regulation OVP Threshold 0A 560mV pk-pk ±3% 66V± ± 4V * Ripple is 800mV pk-pk @ -10°C General Specifications AC Input 100-240Vac, ±10%, 47-63Hz, 1∅ Turn On Time Less than 3 sec. @115Vac, Full Load Input Current Max. 115Vac: 1.8A, 230Vac: 0.9A Hold-up Time 20mSec at 130W, 120Vac/60Hz Inrush Current Input Fuses Earth Leakage Current Efficiency www.slpower.com < 55A peak, 264Vac, cold start, turn on at AC zero crossing F1, F2: 4A, 250Vac fuses provided on all models Overtemperature Protection Overload Protection Sensing transformer temperature, 165°C latching type, requires input power recycling to reset. Hiccup Mode <500µA@264Vac, 60Hz, NC Short Circuit Protection Hiccup Mode, auto recovery. Minimum of 90% Overvoltage Protection OVP latch LB130S56K REV 1.9 15-APRIL-14 LB130S 130W Single Output LED Supply Output Power Transient Response Ripple and Noise Maximum of 130 Watts conduction at 70°C 200 Watts of peak for minimum of 60 Sec @ 50°C 500µS typical, return to 0.5% of nominal, ∆i/∆t: <0.2A/µS. Max Voltage Deviation = 3% Test Conditions: a)5% to 50% load change b)50% to 100% load change c)100% to 50% d)50% to 5% 0.5%rms, 1% pk-pk, see chart. Switching Frequency Isolation Operating Temperature 56V Heat-Sink Temperature Voltage Adjustability Fixed Output Storage Temperature Minimum Load Not required Altitude Output Voltage Total Regulation Vibration Dimensions Weight +/- 3% combined line, load and initial setting. Relative Humidity Operating: 0.003g²/Hz, 1.5grms overall, 3 axes, 10 min/axis Non-Operating: 0.026g²/Hz, 5.0grms overall, 3 axes, 1 hr/axis W: 3.0” x L: 5.0” x H: 1.3” Shock Safety Standards Life 380g The specification above is based on 25°C ambient. www.slpower.com LB130S56K REV 1.9 15-APRIL-14 PFC: Fixed, 65kHz Main Converter: Variable 35-200kHz, 6570kHz at full load Input-Output: 3,000Vac Input-Ground: 1,800Vac Output-Ground: 1,500Vac Conduction Cooled: -10°C to +70°C Full Load Convection Cooled: -10°C to +50°C Full Load, 110 Watts @ 60°C, 90 Watts @70C Start Up at -40°C To maintain Safety approval & life expectancy, heat-sink temperature should not exceed 85°C -40°C to +85°C Operating: -457 to 3000 m Non-operating: -457 to 12,192m. 5% to 95%, non-condensing Operating: Half-sine, 20gpk, 10ms, 3 axes, 6 shocks total Non-Operating: Half-sine, 40 gpk, 10 ms, 3axes, 6 shocks total EN/CSA/UL/IEC 60950-1, 2nd Edition 50,000 Hrs at 70°C, 130 Watts of output, 115Vac or 230Vac input Voltage LB130S 130W Single Output LED Supply EMI/EMC Compliance Conducted Emissions EN55015 Class B, FCC Part 15, Subpart B, Class B Radiated Emissions EN55022 Class A, FCC Part 15, Subpart B, Class A w/6db margin Static Discharge Immunity EN61000-4-2, 6kV Contact Discharge, 8kV air discharge Radiated RF Immunity EN61000-4-3, 3V/m. EFT/Burst Immunity EN61000-4-4, 2kV/5kHz Line Surge Immunity EN61000-4-5, 1kV differential, 2kV common-mode Conducted RF Immunity EN61000-4-6, 3Vrms Power Frequency Magnetic Field Immunity EN61000-4-8, 3A/m Voltage Dip Immunity EN61000-4-11, 100%, 10ms; 30%, 275ms; 60%, 100ms; Performance Criteria A, A, & A at 70% load. Line Harmonic Emissions EN61000-3-2, Class C from no load to 100% load Flicker Test EN61000-3-3, Complies (dmax<6%) Mechanical Drawing Notes: 1. All dimensions in inches (mm), tolerances are mentioned for each measurement 2. Mounting holes should be grounded for EMI purposes. 3. FG is safety ground connection. 4. The power supply requires mounting on metal standoffs 0.20” (5mm) in height, min. Connector Information Input Connector J100 Ground (FG) DC Output Connector J300 PIN 1) AC LINE PIN 2) EMPTY PIN 3) AC NEUTRAL 0.25” FASTON TAB Term. 1,2,3: RTN Term. 4,5,6: +Vout Mating Connector: AMP Molex 640250-3 Pins: 640252-2 Mating Connector: Molex 190020001 Mating Connector: AMP 640250-6 Pins: 640252-2 Data Sheet © 2014 SL Power Electronics Corp. The information and specifications contained herein are believed to be correct at the time of publication. However, SL Power accepts no responsibility for consequences arising from reproduction errors or inaccuracies. Specifications are subject to change without notice. www.slpower.com LB130S56K REV 1.9 15-APRIL-14