LB240S24K

LB240S
240W Single Output LED Supply
Features
3” x 5” x 1.3” Package
240 Watts
EN55015 Class B Conducted EMI
50°C Ambient Operation with 300 LFM
130 Watts @ 70C (Conduction Cooled)
190 Watts @ 60C (200 LFM)
160 Watts @ 70C (200 LFM)
Universal Input 90-264Vac
Meets IEC61000-3-2 Class C for 0% to 100% LED
Dimming Applications(1 Watt input power to full
load)
EN60950 2nd Edition
Description
The LB240 model is the highest density conduction cooled power supply in a compact 3X5 package. Providing
240 Watts of power at 50°C ambient with 300 LFM airflow, the LB240 is designed to meet global lighting
requirements and has a built-in EMI filter to meet EN55015 class B.
Model Chart
Model*
Number
Volts
Maximum
Output
Current
(A)
LB240S56K
56V
4.29
0A
560mV pk-pk
±3%
66V±
± 4V
LB240S48K
48V
5
0A
480mV pk-pk
±3%
56V±
± 3V
LB240S24K
24V
10
0A
240mV pk-pk
±3%
29V±
±2.5V
Minimum
Load
Ripple &
Noise**
Total
Regulation
OVP
Threshold
* For Cold Plate cooling, add option H. Consult the factory for model number availability.
**Ripple is 800mV pk-pk @ -10°C
General Specifications
AC Input
100-240Vac, ±10%, 47-63Hz, 1∅
Turn On Time
Less than 3 sec. @115Vac, Full Load
Input Current
Max. 115Vac:2.6A, 230Vac: 1.3A
Hold-up Time
12 mSec min, 115Vac/60Hz
Inrush Current
Input Fuse
Earth Leakage
Current
www.slpower.com
< 55A peak, 264Vac, cold start, turn on
at AC zero crossing
5A, 250Vac fuse provided on all models
<500µA@264Vac, 60Hz, NC
LB240S56K REV 10.0
Overtemperature
Protection
Overload
Protection
Short Circuit
Protection
10-MAY-2015
Sensing transformer temperature, 165°C
latching type, requires input power
recycling to reset.
Hiccup Mode
Hiccup Mode, auto recovery. A direct hard
short may latch off the converter; remove
AC input to reset.
LB240S
240W Single Output LED Supply
Efficiency
Output Power
VIN
(Vac)
115
230
24V
------88%
90%
48V
------90%
92%
56V
------90%
92%
240 Watts max. with 300 LFM
Overvoltage
Protection
Switching
Frequency
OVP latch, remove AC input to reset.
PFC: Fixed, 65kHz
Main Converter: Variable 35-200kHz, 6570kHz at full load
For 5% to 50% or 50% to 5% load
change: <20 mSec, return to 1% of
nominal, di/dt <0.2A/uS. Max voltage
deviation=3%
Transient
Response
For 50% to 100% or 100% to 50% load
change: <1 mSec, return to 1% of
nominal, di/dt <0.2A/uS. Max voltage
deviation=3%
Isolation
Input-Output: 3,000Vac
Input-Ground: 1,800Vac
Output-Ground: 1,500Vac
For 5% to 100% or 100% to 5% load
change: 25 mSec, return to 1% of
nominal, di/dt <0.2A/uS. Max voltage
deviation=4%
Ripple and
Noise
0.5%rms, 1% pk-pk, see chart.
Operating
Temperature
-10°C to +70°C( See Below Chart)
Start Up at -40°C
See Model Chart
Heat-Sink
Temperature
To maintain Safety approval & life
expectancy, heat-sink temperature should
not exceed 85°C
Voltage
Adjustability
Fixed Output
Storage
Temperature
-40°C to +85°C
Minimum Load
Not required
Altitude
Output Voltage
Total Regulation
Vibration
Dimensions
Weight
+/- 3% combined line, load and initial
setting.
Operating: 0.003g²/Hz, 1.5grms overall,
3 axes, 1 hr/axis
Non-Operating: 0.026g²/Hz, 5.0grms
overall, 3 axes, 10 min/axis
W: 3.0” x L: 5.0” x H: 1.3”
“H” option: 3.0”x 6.0” x1.5”
Relative Humidity
Shock
Safety Standards
370g
“H” option: TBD
Life
Operating: -457 to 3000 m
Non-operating: -457 to 12,192m.
5% to 95%, non-condensing
Operating: Half-sine, 20gpk, 10ms, 3 axes,
6 shocks total
Non-Operating: Half-sine, 40 gpk, 10 ms,
3axes, 6 shocks total
EN/CSA/UL/IEC 60950-1, 2nd Edition
100,000 hours, 50C for 240W
40,000 hours, 70C for 130W
438,540 hours.
Conditions:
20 dB A max per ISO7779
Standard: Telcordia SR-332 issue 3
with 0% - 100% static load
Audible Noise
MTBF Ambient temp: 25c
25 dB A max per ISO7779
Voltage: 110v
with 0% - 100% - 0% transient load
Level: 0/1
Environment: Ground, fixed, controlled
The specification above is based on 25°C ambient and where applicable at nominal input voltage of 100 to 240VAC.
Ambient
Cooling Method
Wattage (watts)
50˚C
Forced Air, 300 LFM
240
60˚C
Forced Air, 200 LFM
190
70˚C
Forced Air, 200 LFM
160
70˚C with Max. Temperature of primary heat-sink to be held under 85˚C
Conduction
130
50˚C
Convection
160
40°C with “H” option, Max. Temp of cold plate to be held under 60˚C
Conduction
200
www.slpower.com
LB240S56K REV 10.0
10-MAY-2015
LB240S
240W Single Output LED Supply
EMI/EMC Compliance
Conducted Emissions
EN55015 Class B, FCC Part 15, Subpart B, Class B
Radiated Emissions
EN55022 Class A, FCC Part 15, Subpart B, Class A
Static Discharge Immunity
EN61000-4-2, 6kV Contact Discharge, 8kV air discharge
Radiated RF Immunity
EN61000-4-3, 3V/m.
EFT/Burst Immunity
EN61000-4-4, 2kV/5kHz
Line Surge Immunity
EN61000-4-5, 1kV differential, 2kV common-mode
Conducted RF Immunity
EN61000-4-6, 3Vrms
Power Frequency Magnetic Field Immunity
EN61000-4-8, 3A/m
EN61000-4-11, 100%, 10ms; 30%, 500ms; 60%, 100ms;
Performance
Criteria A, A, & A at 58% load.
EN61000-3-2, Class A, D
For Class C from 1W input power to full load
Voltage Dip Immunity
Line Harmonic Emissions
Flicker Test
EN61000-3-3, Complies (dmax<6%)
Mechanical Drawing
Notes
1. All dimensions in inches (mm), tolerances
are mentioned for each measurement
2. Mounting holes should be grounded for
EMI purposes.
3. FG is safety ground connection.
4. The power supply requires mounting on
Metal standoffs min. of 0.20” (5mm) in height
LB240SXXKH
www.slpower.com
LB240S56K REV 10.0
10-MAY-2015
LB240S
240W Single Output LED Supply
Connector Information
Input Connector
J100
Ground
(FG)
DC Output Connector
J300
PIN 1) AC LINE
PIN 2) EMPTY
PIN 3) AC NEUTRAL
0.25” FASTON TAB
Term. 1,2,3: RTN
Term. 4,5,6: +Vout
Mating Connector:
AMP 640250-3
Pins: 640252-2
Mating Connector:
Molex 190020001
Mating Connector:
AMP 640250-6
Pins: 640252-2
Data Sheet © 2015 SL Power Electronics Corp. The information and specifications contained herein are believed to be correct at the time of publication. However, SL Power accepts no responsibility for
consequences arising from reproduction errors or inaccuracies. Specifications are subject to change without notice.
www.slpower.com
LB240S56K REV 10.0
10-MAY-2015