GPHP SERIES SINGLE OUTPUT POWER SUPPLY SUMMARY High Power Supplies 600/700 Watt AC/DC Universal Input Power Supply • 90 -264 Vac nominal input range • Overvoltage and short circuit protection • Approved to UL, CSA and EN Standards • Power Good LED • Low Leakage g The GPHP Series are universal input AC/DC power supplies with power factor correction (PFC) with up to 700 Watts ouput power. The GPHP product in corporates ‘hot-swap’ capabilities and a handle. The series is approved to EN60950 to reduce design-in time and end system compliance costs GPHP 600 shown in CRA rack SPECIFICATIONS All specifications are typical at nominal input, full load at 25 OC unless otherwise stated OUPUT SPECIFICATIONS Output Power Integral forced air Total Regulation INPUT SPECIFICATIONS 700 Watts max. See table Input Voltage range Universal input 100-240 nom (85 - 264 max) Vac Rise time At turn-on 2.0 s max. Input frequency 47 Hz to 63 Hz Transient response Main output 25% 0.1 A/ms 3.5% max. dev. 350 ms recovery to 1% Input surge current 25 A max. Ground Leakage current 264 Vac 60 Hz 160 mA Temperature Coefficient +/-0.03%/oC Input current 120 Vac 8.5 A Overvoltage protection 125% +/-10% 230 Vac 4.5 A F1,F2 10.0 A Short Circuit protection block wall Yes EMC INFORMATION ENVIRONMENTAL SPECIFICATIONS Conducted emissions FCC Pt 15, EN55022 Level B Radiated emissions FCC Pt 15, EN55022 Level A Line freq. harmonics EN61000-3-2 Class A Voltage fluctuations EN61000-3-3 Complies (clause 5b) ESD Air EN61000-4-2 8 kV contact ESD Contact EN61000-4-2 6 kV air Radiated immunity EN61000-4-3 operating ambient (see ratings chart) -20 oC -50 oC non-operating -40 to +85 oC 0 - 50 oC Convection cooled 600 Watts Maximum Altitude operating / non-operating 10,000 ft. / 40,000 ft. max. 3 V/m Relative Humidity non-condensing 5% - 95% RH Vibration (operating) 0.003 g /Hz 1.5 grms 3 axes 10 min/axis Vibration (non-operating) 0.026 g2/Hz 5.0 grms 3 axes, 1 hr/axis Shock half-sine 20 gpk 10 ms, 3 axes, 6 shocks total Shock half-sine 40 gpk 10 ms, 3 axes, 6 shocks total Fast Transients (EFT) EN61000-4-4 2 kV 5 kHz Line surge immunity EN61000-4-5 1 kV diff /2 kV cm Conducted immunity EN61000-4-6 3 Vrms Power freq. mag. field EN61000-4-8 3 A/m Voltage dip immunity EN61000-4-11 Unit will ride through without loss of output at 75% of rated load with AC power fail warning. Page 1 of 3 Input fuse Thermal Performance 2 GENERAL SPECIFICATIONS Hold-up time Efficiency isolation voltage 120 Vac, 60 Hz 120 Vac 600 W output input to ouput input to ground fixed Switching frequency Safety Approvals Maximum weight MODEL NUMBER GPHP600-24 GPHP600-28 GPHP600-36 GPHP700-48 Output 24 V 25 A 28 V 21.5 A 36 V 17 A 48 V 14 A Peak Output 24 V 27 A 28 V 23.5 A 36 V 19 A 48 V 15.6 A 30 ms at 600 Watts output >84 % 4000 Vac 1500 Vac 70 KHz, +/- 10 KHz UL/EN/IEC 60950-1 1st Edition CSA22.2 No.60950-1-03 2 kg (4.4 lbs) Features Hot Swap Hot Swap Hot Swap Hot Swap Ripple 240 mV 240 mV 240 mV 240 mV Regulation 3% (see note 4) 3% (see note 4) 3% (see note 4) 3% (see note 4) NOTES 1. Integral forced air cooling 2. Peak rating is for 1 minute maximum 10% duty cycle 3. Noise measurent 20 MHz Bandwidth, differential mode. Measured with scope probe directly across output terminals of the power supply. 4. Regulation includes provision for ‘droop’ sharing MECHANICAL NOTES The GPHP series is factory configured for rack mounting installation with Condor CRA series racks. Other mounting configurations and connector options are available, Please contact factory. POWER CONNECTOR DIN # 41612 Type H INPUT PINS Z-32 AC Line D-30 AC Neutral Z-28, D26 GROUND OUTPUT PINS Z12, D14, Z16,D18 OUTPUT Z4, D6, Z8, D10 RETURN (COMMON) STATUS & CONTROL PINS Z20 DC POWER GOOD Z24 INHIBIT D22 AC POWER FAIL Page 2 of 3 OUTLINE AND MOUNTING DRAWING Other drawings and SolidWorks™ 3D Models are available on request. Condor DC Power Supplies Inc. 2311 Statham Parkway, Oxnard CA, 93033, USA. Phone:(805) 486 4565 Fax:(805) 487 8911 Email: [email protected] GPHP600/700 RevB 11/15/05. Data Sheet © 2005 Condor DC Power Supplies Inc. The information and specifications contained in this data sheet are believed to be correct at time of publication. However, Condor accepts no responsibility for consequences arising from reproduction errors or inaccuracies. Specifications are subject to change without notice. SolidWorks is a trademark of SolidWorks Corp. Page 3 of 3