LE150S-VN 150W Single Output LED Driver Series Features High Efficiency (up to 93%) Wide Range Universal Input 90-305 VAC Active Power Factor Correction (0.99 typical) Constant Voltage Output Lightning Protection Waterproof (IP67) Overcurrent, Overvoltage, Overtemperature Protection Meets UL8750, UL935 & EN61347 Safety SELV Minimum of 3 Year Warranty, Consult factory for 5 Years Description The LE150S-VN Series operate from a 90 ~ 305Vac input range. These units will provide up to a 150W of output power. They are designed to be highly efficient and highly reliable. The standard features include lightning protection, overvoltage protection, short circuit protection, and over temperature protection. Model Selection Model Number Output Current Output Voltage LE150S24VN 0 – 6.25A 24Vdc 89%-90% 92%-93% 2% of Vo pk-pk ±1% ±2% 110% - 130% of Vo LE150S48VN 0 – 3.13A 48Vdc 89%-90% 92%-93% 2% of Vo pk-pk ±1% ±2% 110% - 130% of Vo Notes: Efficiency* 110Vac 220Vac Ripple & Noise** Regulation Line Load Overvoltage Trip Level 1. Efficiency measured at full load, at input voltage noted. 2. Measured at 20MHz bandwidth, with noise probe directly across output terminals, and load terminated with 0.1µF ceramic and 10µF low ESR electrolytic capacitors. General Specifications AC Input Input Current Inrush Current Input Fuses www.slpower.com 90-305Vac, 47-63Hz, 1∅ Turn On Time 1.5 seconds, max. 100Vac: 1.75A, 220Vac: 0.8A Hold-up Time 20 mSec 230Vac, cold start: will not exceed 65A XA, 250VAC fuses provided on all models Dimming Function Overload Protection LE150S-VN 15-APRIL-2013 N/A 110%-180% of Io rated, Hiccup Mode 1 LE150S-VN 150W Single Output LED Driver Series General Specifications (continued) Earth Leakage Current Efficiency Output Power <1.0mA@277Vac, 50Hz See Models chart. 150W continuous Short Circuit Protection Provided - no damage to unit, self-recovery. Overvoltage Protection Latch mode. AC input will need to be reset to return to normal operation after an OVP condition. See chart for trip range. Overtemperature Protection Latch mode. AC input will need to be reset to return to normal operation after an OTP condition. Trip Temperature = 110°C typical. Ripple and Noise See chart Operating Temperature Output Voltage See chart Relative Humidity 10% to 100% operating 5% to 100%, non-operating +/- 3%. See chart Safety Standards UL8750, UL935, UL1012, CSA-C22.2 No. 0, No. 107.1, & No. 250.0, EN61347-1, EN61347-2-13 Total Regulation Dimensions Weight MTBF W: 3.13” x L: 9.37” x H: 1.81” Lifetime 1500g Operating: -35°C to +70°C Non-operating: -40°C to +85°C 261,000 hours (110Vac input, 80% load, 25°C ambient, per MIL-HDBK-217F). 78,000 hours (220Vac input, 80% load, 60°C case temperature). EMI/EMC Compliance Emissions EN55015, Radiated & Conducted EMI for Lighting Equipment EN61547 Static Discharge Immunity EN61000-4-2, 4kV Contact Discharge, 8kV air discharge Radiated RF Immunity EN61000-4-3 EFT/Burst Immunity EN61000-4-4 Line Surge Immunity EN61000-4-5, 4kV line-line, 6kV line-earth Conducted RF Immunity EN61000-4-6 Power Frequency Magnetic Field Immunity EN61000-4-8 Voltage Dip Immunity EN61000-4-11 Line Harmonic Emissions EN61000-3-2 Flicker Test EN61000-3-3 www.slpower.com LE150S-VN 15-APRIL-2013 2 LE150S-VN 150W Single Output LED Driver Series Derating Curves Mechanical Drawing Data Sheet © 2012 SL Power Electronics Corp. The information and specifications contained herein are believed to be correct at the time of publication. However, SL Power accepts no responsibility for consequences arising from reproduction errors or inaccuracies. Specifications are subject to change without notice. www.slpower.com LE150S-VN 15-APRIL-2013 3