CINT1200 200W Single Output Industrial Series Features 3” x 5” x 1.3” Package 200W with 100LFM Air 180W Convection Cooled Class B Conducted EMI Fits 1U Applications Universal Input 90-264 Vac Approved to CSA/EN/IEC/UL60950-1, 2nd Edition Efficiency 90% typical 3 Year Warranty RoHS Compliant Description A power-packed, highly efficient AC to DC power supply designed for industrial and ITE applications. These models provide 180 Watts convection cooled, 200 Watts with moving air. The small heat footprint allows simple thermal design of systems which use this product. All models are CE marked to low voltage directive and approved to ITE standards of EN60950-1, 2nd edition. Model Selection Model Number Volts Minimum Load Ripple & Noise** Total Regulation OVP Threshold*** CINT1200A1275K01 12V 16.7A 15.0A 0A 120mV pk-pk ±3% 14.0 ± 1.1V CINT1200A1575K01 15V 13.3A 12.0A 0A 150mV pk-pk ±3% 18.5 ± 1.2V CINT1200A1875K01 18V 11.1A 10.0A 0A 180mV pk-pk ±3% 21.5 ± 2.0V CINT1200A2475K01 24V 8.33A 7.50A 0A 240mV pk-pk ±3% 29.0 ± 2.5V CINT1200A2875K01 28V 7.14A 6.40A 0A 280mV pk-pk ±3% 33.5 ± 2.5V CINT1200A3275K01 32V 6.25A 5.62A 0A 320mV pk-pk ±3% 36.0 ± 3.0V CINT1200A3675K01 36V 5.55A 5.00A 0A 360mV pk-pk ±3% 41.0 ± 3.0V CINT1200A4875K01 48V 4.17A 3.75A 0A 480mV pk-pk ±3% 56.0 ± 3.0V Notes: Output Current w/100LFM air Convection* * Total convection power is 180 Watts. ** Measured with noise probe directly across output terminals, and load terminated with 0.1µF ceramic and 10µF low ESR capacitors. General Specifications AC Input Input Current www.slpower.com 100-240Vac, ±10%, 47-63Hz, 1∅ 120–370Vdc Turn On Time Less than 3 sec. @115Vac, Full Load 115Vac: 1.8A, 230Vac: 0.9A Hold-up Time 16mS at 200W, 120Vac/60Hz CINT1200 REV 1.4 12-JUNE-13 1 CINT1200 200W Single Output Industrial Series Specifications (continued) Inrush Current Input Fuses Earth Leakage Current Efficiency Output Power Transient Response Ripple and Noise Output Voltage 264Vac, cold start: will not exceed 55A F1, F2: 3.15A, 250Vac fuses provided on all models <500µA@264Vac, 60Hz, NC; <1mA SFC Overtemperature Protection Overload Protection Short Circuit Protection Overvoltage Protection 88% typical 200W continuous, with 100 lfm airflow, 180W convection cooled – See chart for specific voltage model ratings. Switching Frequency 500µS typical, return to 0.5% of nominal, 50% load step. ∆i/∆t: <0.2A/µS. Max Voltage Deviation = 3% Isolation Hiccup Mode, auto recovery. OVP latch, see models chart for trip range. PFC: Fixed, 65kHz Main Converter: Variable 35-200kHz, 6570kHz at full load. Input-Output: 4000Vac Input-Ground: 1800Vac Output-Ground: 1500Vac Operating Temperature -10°C to +70°C Start Up at -40°C, full load See chart Temperature Derating Derate output power linearly above 50°C to 50% at 70°C Fixed Output Storage Temperature Minimum Load Not required Altitude Total Regulation +/- 3% combined line, load and initial setting. Vibration Operating: 0.003g²/Hz, 1.5grms overall, 3 axes, 10 min/axis Non-Operating: 0.026g²/Hz, 5.0grms overall, 3 axes, 1 hr/axis Weight 120 to 150% of rating, Hiccup Mode 0.5%rms, 1% pk-pk, see chart. Voltage Adjustability Dimensions Sensing transformer temperature, 165°C at full load, latching type, requires input power recycling to reset. W: 3.0” x L: 5.0” x H: 1.3” Relative Humidity Shock Safety Standards MTBF 325g -40°C to +85°C Operating: -500 to 10,000 ft. Non-operating: -500 to 40,000 ft. 5% to 95%, non-condensing Operating: Half-sine, 20gpk, 10ms, 3 axes, 6 shocks total Non-Operating: Half-sine, 40 gpk, 10 ms, 3 axes, 6 shocks total EN/CSA/UL/IEC 60950-1, 2nd Edition 401,000 hours, 25°C, 110Vac Output vs. Temperature Derating Curve 180W convection cooled and 200W continuous with 100 LFM airflow, derate output power to 50% at 70°C. www.slpower.com CINT1200 REV 1.4 12-JUNE-13 2 CINT1200 200W Single Output Industrial Series EMI/EMC Compliance Conducted Emissions EN55011/22 Class B, FCC Part 15, Subpart B, Class B Radiated Emissions EN55011/22 Class A, FCC Part 15, Subpart B, Class A w/6db margin Static Discharge Immunity EN61000-4-2, 6kV Contact Discharge, 8kV air discharge Radiated RF Immunity EN61000-4-3, 3V/m. EFT/Burst Immunity EN61000-4-4, 2kV/5kHz Line Surge Immunity EN61000-4-5, 1kV differential, 2kV common-mode Conducted RF Immunity EN61000-4-6, 3Vrms Power Frequency Magnetic Field Immunity EN61000-4-8, 3A/m Voltage Dip Immunity EN61000-4-11, 100%, 10ms; 30%, 275ms; 60%, 100ms; Performance Criteria A, A, & A at 70% load. Line Harmonic Emissions EN61000-3-2, Class A, B, C, & D Flicker Test EN61000-3-3, Complies (dmax<6%) Mechanical Drawing Notes: [4] x 0.156 4 PLCS MTG HOLES 1. All dimensions in inches (mm), tolerance is +/-0.000”. 2. Mounting holes should be grounded for EMI purposes. 3. FG is safety ground connection. 4. The power supply requires mounting on metal standoffs 0.20” (5mm) in height, min. Connector Information Input Connector J100 Ground (FG) DC Output Connector J300 PIN 1) AC LINE PIN 2) EMPTY PIN 3) AC NEUTRAL 0.25” FASTON TAB Term. 1,2,3: RTN Term. 4,5,6: +Vout Mating Connector: AMP Molex 640250-3 Pins: 640252-2 Mating Connector: Molex 190020001 Mating Connector: AMP 640250-6 Pins: 640252-2 Data Sheet © 2012 SL Power Electronics Corp. The information and specifications contained herein are believed to be correct at the time of publication. However, SL Power accepts no responsibility for consequences arising from reproduction errors or inaccuracies. Specifications are subject to change without notice. www.slpower.com CINT1200 REV 1.4 12-JUNE-13 3