MB60S 60W Single Output Medical Series Features Ultra Small size of 2” x 3” x 1” For 1U Applications 60W convection cooled Universal Input 90-264Vac Approved to IEC60601-1, 3rd Edition with 2 MOPP Level V Efficiency Compliant Models Less than 0.5W no-load Power Consumption 3 Year Warranty Optional LED indicator for power-on RoHS Compliant Description The MB60S Series models provide a reliable power source in high power density in 2” x 3” x 1” package. Fully compliant to the applicable safety and EMC standards, these models will allow easy integration into many Medical applications. All 6 models are CE marked to low voltage directive and approved to Medical standards of IEC60601-1 3rd edition with 2 MOPP. Model Selection Model Number Volts Output Current Convection Cooled Output Power Convection Cooled Ripple & Noise* Total Regulation OVP Threshold MB60S12K 12V 4.58A 55W 120mV pk-pk ±2% 14.4-18Vdc MB60S15K 15V 4.00A 60W 150mV pk-pk ±2% 18-22.5Vdc MB60S18K 18V 3.33A 60W 180mV pk-pk 2% 21-25.5Vdc MB60S24K 24V 2.50A 60W 240mV pk-pk ±2% 28.8-36Vdc MB60S36K** 36V 1.67A 60W 360mV pk-pk ±2% 42-47Vdc MB60S48K 48V 1.25A 60W 480mV pk-pk ±2% 57.6-72Vdc Notes: * At -20C, the noise and ripple is 2% of the output. ** For product availability, please contact the factory Input Specifications PARAMETER SPECIFICATION AC Input Voltage: 90-264Vac, single phase AC Input Frequency: AC Input Current: Turn-on Input Voltage: Turn-off Input Voltage: Inrush Current: 47-63Hz 120Vac: 1.4A, 240Vac: 0.75A 75V 65V 40A maximum @ 0C www.slpower.com MB60S 6-July-15 NOTES Ramping Up Ramping Down 1 MB60S 60W Single Output Medical Series Leakage Current (Input–Earth): <275µA@264Vac, 60 Hz input, NC Leakage Current (Output–Earth): N/A Leakage Current (Input-Output): <90µA@264Vac, 60 Hz input, NC Input Fuses: F1, F2: 4A, 250VAC Fuses provided on all models Typical Measured at 120Vac and full load Efficiency MB60S12K 83% MB60S15K 85% MB60S18K 85% MB60S24K MB60S36K MB60S48K 88% 88% 88% No Load Input Power: Turn-on Time: <0.5W <2 Seconds at 120Vac. 16mS minimum from loss of ac input at 120 Vac, full load. Hold-up Time: rd IEC 60601-1 3 Ed – 8.7.3.c 24V, 36V, and 48V Models meet Level V requirement Meet Level V, standby Power Consumption 55 Watts for 12V output DC Output Specifications PARAMETER SPECIFICATION Output Power: 60W continuous for operation from -10ºC to 50ºC 55 Watts for 12V output. Cooling: Convection Total Regulation: ±2% for all models Overload Protection: 120% - 180% of rated output current value, Hiccup Mode Short Circuit Protection: Overtemperature Protection: Short across the output terminals will not cause damage to the unit. Hiccup Mode OVP firing reduces output voltage to <50% of nominal in <50mS. See chart for trip range Automatic Power Shutdown at Tc = 155ºC, Minimum Load: No minimum load is required Overvoltage Protection: Ripple and Noise: Transient Response: Overshoot: www.slpower.com 0.5% RMS, 1% pk-pk for all models. NOTES Total regulation is the maximum deviation from nominal voltage for all loading conditions 20 MHz Bandwidth, differential mode. Measured with noise probe directly across output terminals, and load terminated with 0.1µF ceramic and 10µF low ESR capacitors 500µs typ. response time for return to within 0.5% of final value for a 50% load change, ∆i/∆t< 0.2A/µs. Max. voltage deviation is 3.5%. 5% overshoot at turn-on, 5% overshoot at turn-off, under all conditions. MB60S 6-July-15 2 MB60S 60W Single Output Medical Series Safety Standard Compliance Agency CONDITIONS rd UL ANSI/AAMI ES60101:2005, 3 Edition CSA CAN/CSA-C22.2 No. 60601-1 (2008) Demko EN 60601-1:2006 rd CB Report IEC 60601-1 (3 Edition) Isolation Type: B rated Isolation Specifications PARAMETER Insulation Safety Rating: Electric Strength Test Voltage: CONDITIONS Rating Input to Ground 1 MOPP Input to Output 2 MOPP Output to Ground Functional Input to Ground 1800Vac Input to Output 4000Vac Output to Ground 500Vac NOTES . Environmental Specifications PARAMETER Operating Temperature: Temperature Derating: Cooling: Storage Temperature: Altitude: Relative Humidity: Shock: Vibration: SPECIFICATION NOTES -10°C to +80°C -40°C Startup guaranteed For Output Voltage ≥24V, derate output power to 50W @ 60C, 40 Watt @ 70C, and 20 Watts for 80C Convection -40°C to +85°C Operating: -500 to 3,000 meter Non-operating: -500 to 40,000 ft. 5% to 95%, non-condensing Non-Operating: Half-sine, 40 gpk, 10mS, 3 axes, 6 shocks total Random vibration per MIL-STD-810E, Method 514.4, Cat. 1, Figure 514.4-1, 1 hr in each of three axes <24V will derate to 40W at 60C, 30W at 70C, and 20W at 80C Reliability Specifications PARAMETER SPECIFICATION NOTES MTBF: 700,000 hours, 25°C ambient, full load Calculation is done based on Telcordia. Reports for each model is available Warranty: 3 Years Limited HALT Data: Per SL Power Halt procedure Report is available www.slpower.com MB60S 6-July-15 3 MB60S 60W Single Output Medical Series EMI/EMC Compliance PARAMETER SPECIFICATION Conducted Emissions: EN55011/22 Class B; FCC Part 15 Radiated Emissions: EN55011/22 Class A; FCC Part 15 Harmonic Current Emissions EN61000-3-2, Class A Voltage Fluctuations & Flicker EN61000-3-3 Static Discharge Immunity: EN61000-4-2 6kV contact, 8kV air, Criteria A RF Field Susceptability EN61000-4-3 (3V/m), Criteria A Fast Transients/Bursts Surge Susceptability Conducted RF Susceptability Power Frequency Magnetic Field Test Voltage Sags & Surges NOTES EN61000-4-4 (PS: 2kV-40A, other lines 1kV20A), Criteria B EN61000-4-5, Installation Class 3 (1kV diff. mode, 2kV common mode), Criteria A EN61000-4-6 (3Vrms), Criteria A Performance criteria are defined as following: A – Normal performance during and after the test B – Temporary degradation, self-recoverable C – Temporary degradation, operator intervention required to recover the operation EN61000-4-8 (3A/m), Criteria A EN61000-4-11, 95% dip/0.5 cycle (Criteria A), 60%/5cycles (Criteria B ), 30%/25 cycles (Criteria A). Notes: 1. Specifications subject to change without notice. 2. Specifications are for convection rating at factory settings with 115Vac input and 25°C ambient unless otherwise stated. www.slpower.com MB60S 6-July-15 4 MB60S 60W Single Output Medical Series Mechanical Drawing Connector Information Input Connector J100 PIN 1) AC LINE PIN 2) EMPTY PIN 3) AC NEUTRAL Mating Connector: Tyco/AMP 640250-3 Pins = 770461-1 DC Output Connector J2 PIN 1) +Vout PIN 3) -Vout PIN 2) +Vout PIN 4) -Vout Mating Connector: AMP 640250-4 Pins = 770461-1 Ground (FG) 19-30258-0187 (Keystone 1285) (Zierick 895)(.187*0.020) Mating Connector Molex 19002-0005 1. Mounting holes should be connected together for EMI purpose 2. FG is safety ground connection 3. This power supply requires mounting on metal standoffs 0.20” (5mm) in height www.slpower.com MB60S 6-July-15 5 MB60S 60W Single Output Medical Series Characteristic Curves Output vs. Temperature -40C start up. At -20C, the supply meet its full spec except ripple & noise might be increased from 1% to 2% of the output voltage 55W convection cooled, derating output power to 30W at 70°C for outputs 12V and 15V 60W convection cooled, derating output power to 50W at 60°C and 40W at 70°C for Output Voltages ≥ 24V 20W convection cooled at 80C Output Power(W) Output Power vs . Temperature Convection for 12V Model Convection for 24V and above 70 50 30 10 -10 0 10 20 30 40 50 60 70 80 Temperature (° °C) Fig.1 Efficiency vs. Loading Efficiency vs. Output Power 90.0% 80.0% 70.0% 60 45 30 15 6 Efficiency (%) 100.0% Output Power (W) 120Vac 240Vac Fig.2 www.slpower.com MB60S 6-July-15 6 MB60S 60W Single Output Medical Series Ripple & Noise To verify that the output ripple and noise does not exceed the level specified in the product specification, measured using a scope probe socket with 0.1uF ceramic and a 10uF electrolytic capacitor connected in parallel across it, 20MHz BW. 24V OUT, NO LOAD, 90VAC, 60HZ 24V OUT, FULL LOAD, 90VAC, 60HZ 24V OUT, NO LOAD, 264VAC, 50HZ www.slpower.com 24V OUT, FULL LOAD, 264VAC, 50HZ MB60S 6-July-15 7 MB60S 60W Single Output Medical Series Output Transient Response 50% load step within the regulation limits of minimum and maximum load, dI/dt< 0.2A/µSec. Recovery time not specified as there is no laps in regulation with a 50% Load Step. Maximum voltage deviation is 3.5% 24V OUT, 120VAC, 25% TO 75% LOAD STEP 24V OUT, 240VAC, 25% TO 75% LOAD STEP Output Overload Characteristic 24V OUT, 90VAC 24V OUT, 264VAC Short Circuit Protection Supply shall protect itself against Short Circuit conditions. No damage will occur if the output is shorted. 24V OUT, 90VAC 24V OUT, 264VAC www.slpower.com MB60S 6-July-15 8 MB60S 60W Single Output Medical Series Overvoltage Protection OVP firing reduces output voltage to <50% of nominal in <50ms. See models chart for trip ranges. 24V OUT, FULL LOAD, 90VAC, 60HZ 24V OUT, FULL LOAD, 264VAC, 50HZ Turn On Time 24V OUT, FULL LOAD, 90VAC, 60HZ 24V OUT, FULL LOAD, 264VAC, 50HZ Hold Up Time 24V OUT, FULL LOAD, 120VAC, 60HZ Data Sheet © 2012 SL Power Electronics Corp. The information and specifications contained herein are believed to be correct at the time of publication. for consequences arising from reproduction errors or inaccuracies. Specifications are subject to change without notice. www.slpower.com MB60S 6-July-15 However, SL Power accepts no responsibility 9